HomeMy WebLinkAboutS105.03D 3D3D3DLEGEND EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH LIGHT SWITCH, 3-WAY OCCUPANCY SENSOR LIGHT CIRCUIT 3 O/C EL 1. UNLESS NOTED OTHERWISE, EXISTING CEILINGS TO REMAIN THROUGHOUT. REPLACE ALL DAMAGED OR DIRTY CEILING TILES WITH NEW TO MATCH EXISTING. PROVIDE LIKE TILES IN INDIVIDUAL ROOMS TO CREATE UNIFORM LOOK. 2. ALL SWITCHES AND FACEPLATES TO MATCH EXISTING. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. CONFIRM ALL PENDANT LIGHT LOCATIONS AND HEIGHTS WITH DESIGNER AND PROVIDE NEW ELECTRICAL AS REQUIRED. DO NOT CUT CORD OF PENDANT UNTIL EXACT HEIGHT IS FINALIZED. 5. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 6. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY- OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 7. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 8. DECORATIVE FIXTURE(S) SPECIFIED ARE TO BE PURCHASED THRU LOCAL COMMERCIAL VENDOR TO INSURE COMMERCIAL WARRANTIES. PURCHASING FROM OTHER VENDORS OR AVENUES IS AT THE SUPPLIER'S / EC'S RISK NOT, THE PARALLEL DESIGN GROUP'S, OWNER'S, OR TENANT'S. GENERAL NOTES MECHANICAL NOTES KEYED NOTES 1. SCOPE INTENT IS FOR EXISTING MECHANICAL SYSTEMS TO REMAIN. EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED. 2. DIFFUSER LOCATIONS ARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. 3. FIRE STOP ANY EXISTING DECK PENETRATIONS AS REQUIRED. 4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 5. WHERE EXPOSED DECK IS SHOWN, VERIFY WITH DESIGNER AND TENANT IF DUCT WORK SHOULD BE SPIRAL DUCT. 2'x2' LED MATCH EXISTING EXISTING LINEAR FIXTURE TO REMAINEXL CEILING TYPE CEILING HEIGHT ACT -2' x 2' ACOUSTICAL CEILING TO MATCH EXISTING IN SUITE NOTE: ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED WITH 6" (OR MATCH EXISTING SIZE) WHITE AXIOM TRIM UNLESS NOTED OTHERWISE. DECK-EXPOSED DECK PAINT AS NOTED ON PLAN WITH DRY FALL PAINT. PAINT 10' BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE. NEW CEILING GRID, SUSPENDED, 2'x2' NEW GYPSUM BOARD CEILING EXISTING CEILING GRID, SUSPENDED, 2'x2' EXISTING GYPSUM BOARD X X' -X" EXPOSED DECK DIFFUSER, LAY-IN, 2'x2' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 4"x4' AREA NOT IN CONTRACT AREA OF WORK NEW SUSPENDED LINEAR LED MATCH EXISTING STYLE AND INSTALL HEIGHT LENGTH VARIES; SEE DIMENSIONS ON PLAN NL PENDANT, LED MFG: REJUVENATION STYLE: 24" CONICAL DRUM PENADANT FINISH: AGED BRASS WITH WHITE SHADE ITEM #A4379 MOUNTING HEIGHT: BOTTOM OF FIXTURE AT 8'-0" A.F.F. P1 WALL SCONCE MFG: LIGHTOLOGY STYLE: IC WALL MFR ID: FU317835 ITEM #: FLO967642 SIZE: 11.8" FINISH: RED BURGUNDY MOUNTING HEIGHT: MIDDLE OF FIXTURE AT 5'-6" A.F.F.EXLEXL EXL EXL EXL EXL EXL EXL EXLEXLEXLEXLEXLEXLEXLEXL EXL 1 1 1 1 1 1 1 2 2 1 3 1 1 1 1 ELEL ELEL EL 4 1 EXIST DECK 6 NL NL NL 5 NEW DECK 47 7 7 8 10 EQ. EQ.EQ. EQ. EQ. EQ. NL NL P1 P1 P1 P1 10' - 0" 10' - 0"18' - 6"20' - 0"± 18' - 6"6 EXL 9 12 ' - 0"± 9 5' - 6" EQ. EQ. EQ. 5' - 6" 11 11 MECHANICAL DIFFUSER RELOCATION NOT TO SCALE *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELOCATE DIFFUSERS AND FLEX DUCT IF REQUIRED VAV/ HEAT PUMPEXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A201 REFLECTED CEILING PLAN 1 NO WORK IN THIS AREA. EXISTING CEILING, LIGHTING, SWITCHES AND HVAC DIFFUSERS TO REMAIN. 2 EXISTING CEILING AND LIGHTING TO REMAIN. PROVIDE NEW SWITCH TO CONTROL EXISTING FIXTURES IN THIS ROOM. RELOCATE EXISTING DIFFUSERS AS REQUIRED, PER NEW WALL LAYOUT. 3 PROVIDE NEW LIGHT FIXTURE TO MATCH EXISTING. TIE INTO EXISTING SWITCHES/CONTROLS. 4 WHERE EXISTING CEILING GRID/TILE WAS REMOVED, CEILING IS TO BE EXPOSED TO EXISTING DECK. CLEAN UP EXPOSED CEILING OF ANY LOOSE WIRES, ABANDONED CABLE OR UNUSED ITEMS. CEILING TO BE PAINTED TO MATCH ADJACENT EXISTING EXPOSED CEILING. 5 EXISTING ACCENT COLORED EXPOSED DECK TO BE PAINTED WITH DRYFALL PAINT TO MATCH EXISTING GRAY CEILING COLOR IN THE MAJORITY OF THE SUITE. 6 CONTROL LIGHTING IN THIS ROOM WITH 3-WAY DIMMER SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. 7 NEW LIGHT FIXTURE TO BE CONTROLLED BY EXISTING SWITCHES FOR OPEN OFFICE AREA. 8 WHERE EDGE OF EXISTING DRYWALL CEILING IS NEWLY EXPOSED, PROVIDE 6" (OR MATCH EXISTING SIZE) WHITE AXIOM TRIM ALONG ENTIRE VERTICAL EDGE. AREA ABOVE DRYWALL CEILING TO BE SPRINKLERED AS REQUIRED BY CODE. 9 INTENT IS FOR PORTION OF EXISTING RECESSED LINEAR LIGHT TO REMAIN IN EXISTING BULKHEAD AND BE CONTROLLED BY EXISTING SWITCHES FOR OPEN OFFICE AREA. COORDINATE WITH DESIGNER IF THIS IS NOT POSSIBLE. 10 ENTIRE EXPOSED DECK IN THIS ROOM TO BE PAINTED WITH DRYFALL PAINT TO MATCH EXISTING GRAY CEILING COLOR IN THE MAJORITY OF THE SUITE. REMOVE ALL UNUSED WIRES AND EQUIPMENT WHERE EXISTING DRYWALL CEILING AND PORTION OF LIGHT FIXTURE WERE REMOVED. 11 NEW LIGHT FIXTURE TO BE HUNG AT 9'-9" AFF. 1/8" = 1'-0" REFLECTED CEILING PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21