HomeMy WebLinkAbout2021.05.18 - Element Three - Permit SetTENANT/CLIENT REPRESENTATIVE SIGNATURE DATETENANT/CLIENT REPRESENTATIVE NAME PRINTED THE TENANT/CLIENT AGREES THAT THESE DRAWINGS AND SPECIFICATIONS REPRESENT THE ENTIRE SCOPE OF WORK FOR THE IMPROVEMENTS TO BE PROVIDED. THE TENANT/CLIENT'S SIGNATURE BELOW REPRESENTS ACCEPTANCE OF THE FINAL DESIGN. ANY CHANGES TO THIS SCOPE OF WORK INITIATED BY THE TENANT/CLIENT WILL CAUSE CHANGES IN THE TOTAL COST TO THE TENANT/CLIENT AND IN THE COMPLETION DATE FOR THE PROJECT. APPROVAL FOR CONSTRUCTION DRAWING INDEX PROJECT TEAM INTERIOR DESIGNER PARALLEL DESIGN GROUP 8940 RIVER CROSSING BLVD. SUITE 150 INDIANAPOLIS, IN 46240 KAITLYN BARRETT 317.721.4399 kaitlyn@paralleldg.com PROJECT INFORMATION ARCHITECT DESIGNPOINT INC. GEORGE SMALL 4676 ST. JOHN CIR. ZIONSVILLE, IN 46077 PH 317.289.8007 gsmall@designpointarchitects.com 1. EACH CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THIS FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OF THE DRAWINGS. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS ASSEMBLIES, OR SERVICES INDICATED IN THE CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE. 3. FIELD VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO PARALLEL DESIGN GROUP BEFORE BEGINNING ANY CONSTRUCTION. 4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORKSITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 5. GENERAL CONTRACTOR TO REVIEW DOCUMENTS IN DETAIL AND COMMUNICATE ANY ITEMS THAT MAY REQUIRE LEAD TIMES. CONTRACTOR TO COORDINATE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO TEAM ANY DECISIONS THAT NEED TO BE MADE TO KEEP PROJECT SCHEDULE ON TRACK. CONTRACTOR IS RESPONSIBLE FOR DELAYS WHEN LEAD TIMES ARE NOT PROPERLY COMMUNICATED TO OWNER AND PARALLEL DESIGN GROUP. 6. NO SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS/MATERIALS WILL BE ALLOWED WITHOUT PRIOR APPROVAL FROM PARALLEL DESIGN GROUP. PRODUCT CHANGE SUBMITTALS SHOULD BE COMMUNICATED TO PARALLEL DESIGN GROUP ALLOWING ADEQUATE TIME TO RESPOND. 7. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 8. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO PARALLEL DESIGN GROUP FOR APPROVAL ON ALL MATERIALS/PRODUCTS IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 9. PROVIDE SUBMITTAL SHOP DRAWINGS IN A TIMELY FASHION TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 10. ALL MATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY SPECIFIED OR NOT, AND WITH THE LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 11. EACH CONTRACTOR SHALL FULLY REVIEW DRAWING SHEETS TO FULLY UNDERSTAND NEW WORK AND EXISTING CONDITIONS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE IN ADDITION TO COORDINATING FULL EXTENT OF RESPONSIBILITIES WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 12. THE GENERAL CONTRACTOR IS REQUIRED TO PATCH AND REPAIR ANY DAMAGED EXISTING SURFACE TO MATCH NEW. 13. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 14. ALL EQUIPMENT, MATERIALS AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 15. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 16. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 17. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL TO FINISHED FACE OF WALL. 18. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 19. NOTE REGARDING PROJECTS WITHIN MARION COUNTY: LOCAL ORDINANCE REQUIRES ONE SET OF CONSTRUCTION DRAWINGS FOR CLASS 1 STRUCTURES, THAT ARE DESIGNED WITH A FIRE PROTECTION AND LIFE SAFETY SYSTEMS (I.E. FIRE ALARMS), BE SUBMITTED TO THE INDIANAPOLIS FIRE DEPARTMENT (IFD) FOR THE PURPOSE OF CONDUCTING A FIRE DEPARTMENT PLAN REVIEW AND ON-SITE INSPECTIONS. DRAWING SET SHOULD INCLUDE ARCH, STRUCT, MECH, ELEC, SPRINKLER, FIRE ALARM, AND SITE/CIVIL (WHERE APPLICABLE). DRAWINGS MAY BE DELIVERED OR MAILED TO THE IFD PLAN REVIEW DIVISION (1200 MADISON AVENUE, INDIANAPOLIS, IN 46225, ATTENTION: T.J. BURNS). INCLUDE THE DMD STRUCTURAL PERMIT NUMBER (STR-XXXXXX) WITH THE DRAWING SET. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SUBMISSION OF THESE DRAWINGS AND THE REQUIRED FEE TO THE IFD PLAN REVIEW DIVISION. CONTACT THE IFD WITH QUESTIONS REGARDING THIS REQUIREMENT (317-327-5529). GENERAL PROJECT NOTES DEMOLITION NOTES 1. ALL EXISTING EQUIPMENT, FIXTURES, ETC. SHALL REMAIN PROPERTY OF THE OWNER. ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION SHALL BE RETAINED FOR THE OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE OWNER SHALL BE DISPOSED. 2. CONTRACTOR TO VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS. DEMOLITION DRAWINGS ARE A REFERENCE TO AID CONTRACTOR IN EVALUATION OF THE EXTENT OF THE DEMOLITION, BUT SHALL NOT BE CONSIDERED ALL INCLUSIVE. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC. REFERENCE NEW CONSTRUCTION DRAWINGS TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. 3. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT PARALLEL DESIGN GROUP IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 4. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED OR NOTED FOR THE INSTALLATION OF THE NEW WORK. 5. EACH TRADE CONTRACTOR IS RESPONSIBLE TO REFER TO NEW CONSTRUCTION DRAWINGS FOR ADDITIONAL PATCHING AND PREPARATION WORK RELATED TO THE DEMOLITION ITEMS. 6. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 7. CHECK EXISTING FLOOR LEVEL BEFORE INSTALLATION OF NEW FLOORING. PREPARE FLOOR WITH CEMENTITIOUS LEVELING COMPOUND PRIOR TO INSTALLATION OF NEW FLOOR FINISH AS REQUIRED TO MAINTAIN LEVEL. 8. REMOVE ALL ITEMS ASSOCIATED WITH DEMOLISHED WALL IF NOT NOTED OR SHOWN OTHERWISE. SALVAGE ANY ITEMS IS GOOD CONDITION FOR REUSE IN NEW CONSTRUCTION, e.g., OUTLETS. 9. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURFACES, MATERIALS, COMPONENTS, ETC. TO REMAIN OR BE RELOCATED. ANY DAMAGE TO THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND PARALLEL DESIGN GROUP AT NO ADDITIONAL EXPENSE TO THE OWNER. 10. COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE. 11. THE CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED BY THE OWNER TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING OUT OF THE PROJECT AREA. THE OWNER SHALL CONFIRM ALL DUST PREVENTION MEASURE/LOCATIONS, AND SHALL DETERMINE ANY CHANGES TO THESE MEASURES. 12. REMOVE DUST AND DEBRIS FROM NEWLY EXPOSED SURFACES. 13. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 14. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. 1. POWER AND COMMUNICATION PLAN IS TO SHOW ELECTRICAL, VOICE/DATA RECEPTACLES AND TV LOCATIONS. ELECTRICAL CONTRACTOR TO FIELD VERIFY LOAD CAPACITIES AND AVAILABILITY. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL ENGINEERING. 2. REFLECTED CEILING PLAN IS TO SHOW LIGHT FIXTURE, DIFFUSER, AND SWITCH LOCATIONS ONLY. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL ENGINEERING. 3. ELECTRICAL CONTRACTOR RESPONSIBLE FOR RELOCATION AND/OR ADDITION OF HORN STROBES, FIRE ALARM STATIONS AND EXIST SIGNS AS REQUIRED BY CODE. 4. VERIFY IF ANY SPECIAL EQUIPMENT WILL REQUIRE ADDITIONAL AIR FLOW. PROVIDE ADDITIONAL HVAC REQUIREMENTS AFTER APPROVAL FROM TENANT. REVISE ZONING AS NEEDED. 5. PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS PER AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL INFORMATION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY ENGINEERING FOR THESE SYSTEMS. 6. COORDINATE CIRCUITRY REQUIREMENTS FOR FURNITURE SYSTEMS WITH TENANT, BEFORE RUNNING WIRING TO JUNCTION BOXES. 7. CENTER IN CEILING TILES RECESSED DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS, UNLESS OTHERWISE NOTED. 8. REVIEW FIRE DETECTION DEVICE LOCATIONS WITH TENANT PRIOR TO INSTALLATION. 9. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. MECHANICAL & ELECTRICAL NOTES FIRE PROTECTION NOTES 1. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 2. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 1. ALL MATERIALS TO BE DELIVERED IN THEIR ORIGINAL PACKAGING WITH MANUFACTURER'S LABELS. CONTRACTOR WILL BE RESPONSIBLE FOR RECEIVING, STORING AND PROTECTING MATERIALS FROM ANY DAMAGE BY MOISTURE, WIND, SUN ABUSE, OR ANY HARMFUL EFFECTS. DAMAGED MATERIALS WILL BE REJECTED AND MUST BE REPLACED BY THE CONTRACTOR. 2. REMOVE ALL PLATES AND SWITCHES BEFORE PAINTING AND REATTACH AFTERWARDS. 3. ALL REMAINING PAINT (1 GALLON MINIMUM) TO BE LEFT WITH THE OWNER. 4. WALLCOVERING SHALL BE FROM THE SAME PRODUCTION RUN. 5. DO NOT LOCATE WALLCOVERING SEAMS ON CORNERS. WRAP 6" BEYOND INSIDE OR OUTSIDE CORNERS AS INDICATED ON THE FINISH PLAN WHERE CHANGE OF WALLCOVERING LOCATION OCCURS. 6. CONTRACTOR TO REMOVE EXCESS ADHESIVE IMMEDIATELY FROM SURFACE OR WALLCOVERING AS EACH JOINT OR SEAM IS MADE AND BEFORE PROCEEDING TO THE NEXT JOINT OR SEAM. 7. ALL WALLCOVERING SEAMS ARE TO BE CUT STRAIGHT. ASSURE INSTALLATION IS SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, BUBBLES, GAPS, AND/OR OVERLAPS. 8. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) 9. TRANSITION OF DIFFERENT FLOORING MATERIALS SHALL OCCUR AT THE CENTERLINE OF THE DOOR. 10. CONTRACTOR TO PROVIDE AND INSTALL TRANSITION STRIP BETWEEN DISSIMILAR FLOORING MATERIALS. TRANSITION STRIP IS TO BE SCHLUTER OR EQUAL WITH BRUSHED ALUMINUM FINISH OR IS TO BE VINYL AND MATCH VINYL BASE COLOR (e.g. WHERE VCT MEETS CARPET). CONTRACTOR TO DETERMINE TYPE OF SCHLUTER STRIP BASED ON DISSIMILAR FLOORING MATERIALS. CONTRACTOR TO VERIFY TYPE OF TRANSITION WITH PARALLEL DESIGN, IF NOT NOTED, PRIOR TO PLACING ORDER. 11. SUBFLOOR MUST BE LEVEL, SOUND, RIGID, CLEAN/FREE OF ANY DEBRIS, AND PERMANENTLY DRY PRIOR TO INSTALLATION. THE INSTALLATION OF FINISH FLOORING MATERIALS SHALL SERVE AS ACCEPTANCE OF SLAB CONDITION. 12. FLOORING MATERIALS SHALL BE FROM THE SAME PRODUCTION RUN. 13. CONTRACTOR SHALL REPAIR, REFINISH OR TOUCH-UP SURFACES DAMAGED BY SUBSEQUENT WORK. (EXAMPLE: WHERE NEW OUTLETS/FIXTURES HAVE BEEN INSTALLED) 14. LOW VOC CONTENT PAINT AND ADHESIVES TO BE USED THROUGHOUT PROJECT. 15. REVIEW AND ABIDE BY ALL MANUFACTURER INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION OF FINISH MATERIALS. MANUFACTURER RECOMMENDED ADHESIVES/SEALANTS TO BE USED. 16. UPON COMPLETION OF ALL FINISH APPLICATIONS, ALL MATERIALS AND EQUIPMENT SHALL BE REMOVED. CONTRACTOR SHALL INSURE THAT ALL AREAS ARE LEFT CLEAN AND DAMAGE FREE. 17. ANY VARIATION IN PATTERN, TEXTURE, COLOR OR ANY OTHER DEFECT SHOULD BE BROUGHT TO THE ATTENTION OF PARALLEL DESIGN GROUP FOR DIRECTION AND APPROVAL. FINISH NOTES 10. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 11. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS. AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. MECHANICAL & ELECTRICAL NOTES CONTINUED [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A000 COVER SHEET A000 COVER SHEET A001 LIFE SAFETY PLAN A003 ACCESSIBILITY D101 DEMOLITION PLAN A100 WALL TYPES A101 FLOOR PLAN A101D DIMENSION PLAN A110 DOOR SCHEDULE & INTERIOR ELEVATIONS A201 REFLECTED CEILING PLAN A301 POWER AND DATA PLAN A401 FINISH PLAN VICINITY MAP KEY PLAN TOTAL BUILDING AREA: 76,084 SF PROJECT TYPE: REMODEL CONSTRUCTION TYPE: II-B TOTAL AREA ON FLOOR: 19,021 SF ELEMENT THREE OCCUPANCY: (B)USINESS USABLE AREA: 5,657 SF REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2012 INDIANA BUILDING (2012 IBC, ASCE-7-2010) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES APPLICABLE WHERE REQUIRED BY CODE: 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO WALL TYPES SHEET FOR WALL TYPE AND CONSTRUCTION DETAILS. 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. APPLICABLE BUILDING CODES OCCUPANCY LOADS EXISTING ELECTRICAL PANEL LOCATION BUILDING EXIT LOCATION EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING; REFERENCE REFLECTED CEILING PLAN LEGEND EX EL NL EP ASSEMBLY OCCUPANCY REGION(S) STORAGE AREA REGION(S) FE EXIT SIGN RECESSED FIRE EXTINGUISHER OR SURFACE MOUNTED FIRE EXTINGUISHER AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE LOBBY 100 STORAGE 101 IT 102 CONFERENCE 103 CONFERENCE 104 OPEN OFFICE 105 COFFEE 106 PHONE 107 PHONE 108 PHONE 109 OFFICE 113 CONFERENCE 114 HUDDLE 115 ELEL COMMON PATH OF EGRESS DISTANCE = 24'EXIT ACCESS TRAVEL DISTANCE = 128'EXIT ACCESS TRAVEL DISTANCE = 165'EX EX EX WELLNESS 111 PHOTO/VIDEO 112 COPY 110 FEEL EL EL EP FE [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A001 LIFE SAFETY PLAN CHANGE OF OCCUPANCY CLASS: No SPRINKLER SYSTEM (YES/NO): Yes TOTAL BUILDING SQ FT: 76,084 SF SCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL OF PREVIOUSLY BUILT-OUT OFFICE FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS: No 3/32" = 1'-0" LIFE SAFETY PLAN1 OCCUPANCY: (B)USINESS EXIT TRAVEL DISTANCE (FEET): 300 NUMBER OF REQUIRED EXITS: 2 COMMON TRAVEL PATH OF EGRESS (FEET): 100 USABLE AREA: 5,657 SF TOTAL AREA ON FLOOR: 19,021 SF OCC KEY SPACE TYPE OCC CLASSIFICATION AREA SF PER OCCUPANT OCCUPANT LOAD (B)USINESS IBC Accessory storage areas, mechanical equipment room 183 SF 300 0.6 (B)USINESS CONFERENCE IBC Assembly without fixed seats - Unconcentrated (tables and chairs)1,079 SF 15 71.9 (B)USINESS IBC Business areas 4,395 SF 100 43.9 Total Project Area / Total Project Occupant Load 5,657 SF 116.5 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 18"1 1/2" DIAMETER GRAB BAR, 1 1/2" MIN. GAP FROM WALL (TYPICAL) FOLD DOWN SHOWER SEAT 1 1/2" DIAMETER GRAB BAR, 1 1/2" MIN. GAP FROM WALL (TYPICAL) SOAP SHELF, WHERE INDICATED CONTROL AREA HAND HELD ADJUSTABLE SHOWER HEAD (ADA) TRANSFER ADA SHOWER 1' - 6" 1' - 6"3' - 4" 33" - 36"3' - 10"4' - 0 1/4"3' - 1 3/4" MAX32" MIN - 34" MAX19" MIN MAINTAIN MIN. ACCESSIBLE CLEARANCES AS DIMENSIONED 9" MIN 27" MIN ACCESSIBILITY ROLL-UNDER CLEARANCES T-SHAPED TURNING SPACE ARMARMBASE MIN. 1' - 0" MIN. 3' - 0" MIN. 1' - 0"MIN.3' - 0"MIN.2' - 0"MIN. 5' - 0"MIN.5' - 0"X > 24"36" MIN. MANEUVERING CLEARANCE IN AN ALCOVE: FORWARD APPROACH X > 15"60" MIN. MANEUVERING CLEARANCE IN AN ALCOVE: PARALLEL APPROACH ELEVATION PLAN9"MAX. 6" 30" MIN.17"-25" TOE CLEARANCE 8" MIN.2' - 4" MIN.9" MIN.MIN. 11" MAX. 1' - 5"2' - 6" MIN.ELEVATION PLAN KNEE CLEARANCE 4" MAX.X > 27"X 80"³LIMITS OF PROTRUDING OBJECTS 27" MAX.X > 80"VERTICAL CLEARANCE 15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH 20" MAX.48" MAX.44" MAX.UNOBSTRUCTED HIGH FORWARD REACH A. B.32" MIN.36" MIN.32" MIN.36" MIN.24" MAX. 48" MIN. 24" MAX. CLEAR WIDTH OF AN ACCESSIBLE ROUTE (A) 180 DEGREE TURN (B) 180 DEGREE TURN (EXCEPTION)48" MIN.42" MIN. 42" MIN.X < 48"36" MIN. 36" MIN.X < 48"60" MIN.CLEAR WIDTH AT TURN (C) FOLDING DOOR (A) HINGED DOOR (B) SLIDING DOOR 32" MIN. 32" MIN. 32" MIN.90°CLEAR WIDTH OF DOORWAYS (A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) FRONT APPROACH, PUSH SIDE DOOR PROVIDED WITH BOTH CLOSER AND LATCH (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PULL SIDE (F) HINGE APPROACH, PUSH SIDE (G) HINGE APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (H) LATCH APPROACH, PULL SIDE (I) LATCH APPROACH, PULL SIDE, DOOR PROVIDED WITH CLOSER (J) LATCH APPROACH, PUSH SIDE (K) LATCH APPROACH, PUSH SIDE, DOOR PROVIDED WITH CLOSER 18" MIN.48" MIN.12" MIN. 48" MIN.36" MIN. 60" MIN.42" MIN.54" MIN.42" MIN.22" MIN. 48" MIN.22" MIN.48" MIN.24" MIN. 54" MIN.24" MIN 24" MIN. 42" MIN.24" MIN.48" MIN.60" MIN.(A) PULL SIDE (B) PUSH SIDE (C) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH60" MIN.18" MIN.X > 8"48" MIN.X > 8"X > 8"12" MIN.48" MIN.MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES (A) (B) (C) 48" MIN. 48" MIN.48" MIN. DOOR IN SERIES AND GATES IN SERIES (A) STAIRS (B) RAMPS (C) WALKING SURFACES34" - 38"34" - 38" 34" - 38"HANDRAIL HEIGHT 1 1/2" MIN.1 1/2" MIN.HANDRAIL CLEARANCE HANDRAIL PROJECTIONS BELOW GRIPPING SURFACE NOTE: X = TREAD DEPTH 12" MIN. 12" MIN. 12" MIN. X X TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS 5" MAX. 15" MIN. DRINKING FOUNTAIN SPOUT LOCATION [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A003 ACCESSIBILITYREVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 1. WHERE INDICATED, REMOVE WALL CONSTRUCTION IN ITS ENTIRETY. PRIOR TO DEMOLITION, CAREFULLY INVESTIGATE CONCEALED CONDITIONS TO VERIFY THERE IS NO ACTIVE INFRASTRUCTURE. 2. UNLESS NOTED OTHERWISE, EXISTING CEILING GRID, TILE HVAC DIFFUSERS AND RETURNS TO REMAIN. 3. ALL ELECTRICAL SHOWN ON THIS SHEET IS TO BE REMOVED; PATCH WALLS AND FLOOR AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. SEE ELECTRICAL PLAN FOR EXISTING POWER AN DATA TO REMAIN. 4. UNLESS NOTED OTHERWISE, EXISTING FINISHES TO REMAIN. SEE FINISH PLAN FOR FINAL FINISH SELECTIONS AND LOCATIONS. 5. REFERENCE THE COVER SHEET FOR ADDITIONAL DEMOLITION NOTES. 6. PATCH AND PREP WALLS WHERE DEMOLITION OCCURS ADJACENT AN EXISTING WALL. TERMINATE PLUMBING AT THE NEAREST LOCATION. GENERAL NOTESLEGEND SOLID LINES INDICATE EXISTING ITEMS TO REMAIN KEYED NOTES DASHED LINES AND SYMBOLS INDICATE EXISTING ITEMS TO BE REMOVED OR SALVAGED AREA NOT IN CONTRACT AREA OF WORK 1 8 2 3 4 5 5 6 7 7 7 1 9 10 [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032D101 DEMOLITION PLAN 1 EXISTING CASEWORK (INCLUDING FINISHES) TO REMAIN; CLEAN AND REPAIR AS REQUIRED. 2 REMOVE EXISTING WALL MOUNTED SIGNAGE AT THIS LOCATION. PATCH AND REPAIR WALL AS REQUIRED. 3 EXISTING WOOD PLATFORM (INCLUDING RAILING ON LEFT SIDE) TO REMAIN. CLEAN AND REPAIR AS REQUIRED. 4 REMOVE EXISTING BLACK METAL RAILING AT THIS LOCATION. PATCH WALL/FLOOR AS REQUIRED AND PREP TO RECEIVE NEW FINISHES. 5 REMOVE LINEAR LIGHT FIXTURE IN THIS AREA. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 6 REMOVE EXISTING CEILING GRID, TILE, LIGHT FIXTURES AND HVAC DIFFUSERS IN THIS ROOM. AREA IS TO BE EXPOSED TO DECK; REMOVE ALL UNUSED WIRES AND EQUIPMENT. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 7 REMOVE EXISTING FLOORING IN THIS ROOM OR AREA. SEE FINISH PLAN FOR MORE INFORMATION. 8 REMOVE EXISTING CASEWORK. 9 REMOVE ENTIRE EXISTING BACKSPLASH AND PREP WALL TO RECEIVE NEW IN THE SAME LOCATION. SEE FINISH PLAN FOR MORE INFORMATION. 10 REMOVE EXISTING DRYWALL BULKHEAD AND PORTION OF RECESSED LINEAR LIGHT IN THIS AREA. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. 1/8" = 1'-0" DEMOLITION PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 A2 A3 WALL PARTITION TYPEPLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED A METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL ELIMINATOR TRACK LINE OF STRUCTURE UNDERSIDE OF STRUCTURE CEILING GRID STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA 3 -3/4" 4 -7/8"3 -5/8" 2 -1/2" STC: NO SOUND WITH SOUND A2S A3SB2 B3 B6 B1 B1S WALL PARTITION TYPE SEE DETAILS FOR FINISHED HEIGHTPLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED B METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND B2S B3S B6S B8 NON- RATED NA9 -1/4"8" B8S UNDERSIDE OF STRUCTURE C2 C3 C6 C1 C1S WALL PARTITION TYPE 4"PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED C METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND C2S C3S C6S C8 NON- RATED NA8 -5/8"8" C8S LATERAL BRACING AT 4'-0" O.C. MAX. E2 E3 E6 E1 E1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED E METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND E2S E3S E6S E8 NON- RATED NA8 -5/8"8" E8S D2 D3 D6 D1 D1S WALL PARTITION TYPE4"PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED D METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND D2S D3S D6S D8 NON- RATED NA9 -1/4"8" D8S LATERAL BRACING AT 4'-0" O.C. MAX. F2 F3 F6 F1 F1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED F METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND F2S F3S F6S F8 9 -1/4" 8" F8S NON- RATED NA NON- RATED NA NON- RATED NA NON- RATED NA WALL TYPES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A100 WALL TYPESREVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE A3S (OR MATCH EXISTING STUD SIZE). EXISTING FINISHES TO REMAIN; NEW WALLS TO BE BUILT ON TOP OF EXISTING FLOORING. 2. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 4. WHERE PLAN INDICATES EXPOSED DECK AT EXTERIOR WALLS, CONTRACTOR TO PROVIDE, INSTALL, AND FINISH THE DRYWALL ABOVE THE WINDOW HEADER TO DECK AT AS REQUIRED. 5. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS. GENERAL NOTES KEYED NOTES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WALL TYPES LOBBY 100 STORAGE 101 IT 102 CONFERENCE 103 CONFERENCE 104 OPEN OFFICE 105 COFFEE 106 PHONE 107 PHONE 108 PHONE 109 OFFICE 113 CONFERENCE 114 HUDDLE 115 104A 104B COPY 110 WELLNESS 111 PHOTO/VIDEO 112 FE 111112 2/A1101/A1101 4 5 F3S F3S 7 8 9 3/A11010 3 FE 1 6 6 4/A1102 11 F3S LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK PLUMBING RISER DIAGRAM TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE MAI N B LDG . W A S T E 2" W A S T E T O C.O.2" V.SINK MAIN BLDG. VENT 2" VENT TO [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A101 FLOOR PLAN 1 TENANT PROVIDED WALL MOUNTED TELEVISION, INSTALLED BY CONTRACTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH TENANT. 2 PROVIDE BLOCKING AS REQUIRED FOR TENANT PROVIDED GLASS MARKER BOARD. CONFIRM EXACT LOCATION WITH TENANT. 3 REMOVE EXISTING KEGERATORS AND TAP HANDLES IN THIS AREA. PROVIDE NEW GROMMET IN COUNTER WHERE TAP HANDLES WERE REMOVED (CONFIRM EXACT COLOR WITH TENANT). WHERE KEGERATORS WERE REMOVED, PROVIDE (2) NEW 2'-0"W (VIF) PLASTIC LAMINATE PULL OUT DRAWER (DOUBLE TRASH BIN IN EACH DRAWER, BINS PROVIDED BY CONTACTOR). PLASTIC LAMINATE AND HARDWARE FINISH TO MATCH EXISTING CASEWORK AT THIS LOCATION. 4 PROVIDE SINGLE BOWLTOP MOUNT SINK (ELKAY, CROSSTOWN #ECTSR15159TBG, STAINLESS STEEL FINISH) AND FAUCET (DELTA, MATEO SINGLE-HANDLE PULL DOWN #9183-AR-DST, ARCTIC STAINLESS FINISH). 5 UNDERCOUNTER REFRIGERATOR SUPPLIED BY TENANT. 6 EXISTING DOOR AND FRAME TO REMAIN. REMOVE EXISTING HARDWARE AND PROVIDE NEW LEVER STYLE PASSAGE SET. STYLE AND FINISH TO MATCH STUITE STANDARD. 7 PROVIDE NEW FIRE EXTINGUISHER IN SEMI-RECESSED CABINET TO MATCH EXISTING IN THE SUITE. PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH NFPA 10. 8 EXISTING FIRE EXTINGUISHER IN RECESSED CABINET TO REMAIN. CONFIRM THAT EXTINGUISHER IS IN PROPER WORKING ORDER. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH NFPA 10. 9 PROVIDE WATERLINES FOR TENANT PROVIDED COFFEE MACHINE AND WATER/ICE COMBO. COORDINATE EXACT REQUIREMENTS AND LOCATIONS WITH TENANT. 10 IF REQUIRED BY TENANT, PROVIDE WALL MOUNTED PLYWOOD PHONE BOARD. CONFIRM EXACT SIZE AND LOCATION WITH TENANT. ENTIRE PHONE BOARD TO BE PAINTED (PT1) WITH FIRE RETARDANT PAINT. 11 PROVIDE BLOCKING IN WALL AS REQUIRED FOR TENANT PROVIDED WALL MOUNTED GLASS MARKER BOARD. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT. 1/8" = 1'-0" FLOOR PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 GENERAL NOTES 1. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS. 2. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR" OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. KEYED NOTES LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK 15' - 6 7/8" 1 1 1 1' - 5" 14' - 11 1/2"4' - 2 7/8"MIN.13' - 0 3/8" 8' - 2 1/2"6' - 6 3/4"±8' - 10 3/4"1 11 1/2" 1' - 0"26' - 7 1/8"±[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A101D DIMENSION PLAN 1/8" = 1'-0" DIMENSION PLAN1 1 ALIGN FINISHED WALL SURFACES.REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 DOOR HARDWARE AFB AUTOMATIC FLUSH BOLT CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) CL CLOSER DB DEADBOLT DL DUMMY LEVER ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KS KICK STOP KF KEY FOB KP KICK PLATE KS KICK STOP ML MAGNETIC LOCK OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES GENERAL NOTES 1. DOORS: REUSE DOORS FROM DEMOLITION WHERE POSSIBLE. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. FRAMES: REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 3. HARDWARE: REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. PROVIDE NEW HARDWARE ON NEW DOORS AS NOTED ON SCHEDULE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING STANDARD A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 4. CONTRACTOR TO VERIFY THAT NO HOLES/OPENINGS ARE IN EXISTING DOOR DUE TO HARDWARE CHANGES. IF HOLES ARE PRESENT THAT WILL NOT BE FILLED BY NEW HARDWARE, CONTRACTORS TO CONTACT PARALLEL DESIGN GROUP TO CONFIRM ON HOW TO MOVE FORWARD. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. DOOR TYPESFRAME TYPES 1/4" TEMPERED GLASS F1 F2 D1D22"SEE SCHEDULE 2"SEE SCHED.2" 2' - 0" 2" 2"SEE SCHEDULE 2" SEE SCHED. 2" SEE SCHEDULESEE SCHED.SEE SCHEDULESEE SCHED. REMARK 1. PROVIDE ALL REQUIRED HARDWARE AND TRACKS FOR WALL RECESSED POCKET DOOR. PROVIDE RECESSED FINGER PULL. CONFIRM EXACT STYLE WITH TENANT, FINISH TO MATCH SUITE STANDARD. D3 8' - 0"4' - 0" 2"SEE SCHEDULE 2" SEE SCHED. 2" F3 RUSTICA FRENCH QUARTER SINGLE POCKET DOOR CLEAR GLASS RUSTICA POCKET DOOR FRAME COLOR: GREY STEEL MILL/CASEWORK NOTES 1. CAULK SELECTIONS ARE TO BE PROVIDED TO PARALLEL DESIGN GROUP FOR SELECTION AND/OR APPROVAL BEFORE INSTALLATION OF MILLWORK. 2. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO PARALLEL DESIGN GROUP FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 3. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 4. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 5. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND PARALLEL DESIGN GROUP PRIOR TO FABRICATION. PROVIDE SEAMING DIAGRAM TO PARALLEL DESIGN GROUP. 6. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO PARALLEL DESIGN GROUP THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. UNLESS NOTED OTHERWISE ON ELEVATIONS, FILLER PANELS SHALL NOT EXCEED 3" ON EACH SIDE OF CABINETS. 7. UNLESS OTHERWISE SHOWN, PROVIDE 25" DEEP, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 8. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS FOR THE PARTICULAR APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT CHOICES TO PARALLEL DESIGN GROUPS FOR FINAL DECISIONS. 9. PROVED CABINETRY HARDWARE: MFG: SCHAUB AND COMPANY PRODUCT: 79-6-BBZ SIZE: 6" CENTER TO CENTER FINISH: BRUSHED BRONZE MILL/CASEWORK LEGEND EQUIPMENT -BY OTHERS UNDER CABINET LIGHT. REFER TO REFLECTED CEILING PLAN, APPLY 2" LAMINATED APRON LOCKABLE CABINETS AND DRAWERS. CONFIRM REQUIREMENTS WITH TENANT 24"D PLASTIC LAMINATE ROLL OUT TRASH CABINET, DOUBLE-BIN, GENERAL CONTRACTOR TO PROVIDE TRASH BINS EQ UL L T 1' - 3" 1' - 3" 2' - 6" 2' - 6"3' - 0"1' - 9" 3' - 0" T 24"D PLASTIC LAMINATE (PLX) BASE CABINETS PLASTIC LAMINATE (PLX) FILLER PANEL AT WALL VINYL BASE (VB1) 25"D PLASTIC LAMINATE (PLX) COUNTERTOP, 4"H SIDE AND BACKSPLASH 7' - 7" 2' - 6" 2' - 6" 2' - 6" 24"D PLASTIC LAMINATE (PLX) UPPER CABINETS UNDER COUNTER FRIDGE PROVIDED BY TENANT 24"D PLASTIC LAMINATE (PLX) BASE CABINETS PLASTIC LAMINATE (PLX) FILLER PANEL AT WALL VINYL BASE (VB1) 25"D PLASTIC LAMINATE (PLX) COUNTERTOP, 4"H SIDE AND BACKSPLASH 2' - 10"2' - 0" 3' - 3" 3' - 3" NEW TOP MOUNT SINK AND FAUCET; SEE FLOOR PLAN FOR EXACT SPEC 6' - 7 1/8"8' - 7"8' - 7" 1' - 0" 11 1/2" EXISTING WOOD PLATFORM 3/8" TEMPERED GLASS 2" BLACK METAL FRAME BLACK METAL FRAME MULLIONS (4 COLUMNS, 4 ROWS, EQUAL SPACING) ALIGN BOTTOM OF FRAMES 6' - 0" 6' - 0"6' - 0"3' - 6" 3" 6' - 0" 3"3' - 0" 1' - 8" 2' - 6" 4"GLASS FRONT REF. BY TENANT T COFFEE BY TENANT 1' - 7 1/4" 2' - 6" 2' - 6" 2' - 6" EQ EQ 24"D PLASTIC LAMINATE (PLX) BASE CABINETS VINYL BASE (VB1) FULL HEIGHT SOLID SURFACE (SS1) BACK AND SIDESPLASH PLASTIC LAMINATE (PL1) PANEL FLUSH WITH FRONT FACE OF CABINETS 12"D PLASTIC LAMINATE (PLX) UPPER CABINETS 12" DEEP x 1" THICK PLASTIC LAMINATE (PLX) SHELVES 25"D SOLID SURFACE (SS1) COUNTERTOP1' - 8" 10" 10" 10" 1" 1' - 6 1/4" 2' - 6" 2' - 6" 2' - 6" 1' - 8" 10" 10" 10" EQ 1' - 6" 3' - 1" 24"D PLASTIC LAMINATE (PLX) UPPER CABINET 24"D PLASTIC LAMINATE (PLX) PANEL PLASTIC LAMINATE (PLX) SURROUND AT FRIDGE FOR BUILT-IN APPEARANCE; PANELS TO BE FLUSH WITH 24" DEEP CABINET ABOVE; CONFIRM EXACT FRIDGE DIMENSIOSN WITH TENANT [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A110 DOOR SCHEDULE & INTERIOR ELEVATIONS DOOR SCHEDULE DOOR NUMBER ROOM PAIR POWER REQUIRED DOOR FRAME REMARKSWIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE SET 104A CONFERENCE 3' - 0" x 8' - 0" x1 3/4" D2 WOOD MATCH EXISTING F1 MATCH EXISTING MATCH EXISTING PS 104B CONFERENCE 4' - 0" x 8' - 0" x1 3/4" D3 STEEL STEEL F3 STEEL GREY STEEL SEE REMARK 1 111 WELLNESS 3' - 0" x 8' - 0" x1 3/4" D1 WOOD MATCH EXISTING F1 MATCH EXISTING MATCH EXISTING CH, PL 112 PHOTO/VIDEO 3' - 0" x 8' - 0" x1 3/4" D1 WOOD MATCH EXISTING F2 MATCH EXISTING MATCH EXISTING PS 1/2" = 1'-0" COPY 11011/2" = 1'-0" WELLNESS 111 2 1/2" = 1'-0" CONFERENCE 10331/2" = 1'-0" COFFEE 1064 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 3D 3D3D3DLEGEND EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH LIGHT SWITCH, 3-WAY OCCUPANCY SENSOR LIGHT CIRCUIT 3 O/C EL 1. UNLESS NOTED OTHERWISE, EXISTING CEILINGS TO REMAIN THROUGHOUT. REPLACE ALL DAMAGED OR DIRTY CEILING TILES WITH NEW TO MATCH EXISTING. PROVIDE LIKE TILES IN INDIVIDUAL ROOMS TO CREATE UNIFORM LOOK. 2. ALL SWITCHES AND FACEPLATES TO MATCH EXISTING. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. CONFIRM ALL PENDANT LIGHT LOCATIONS AND HEIGHTS WITH DESIGNER AND PROVIDE NEW ELECTRICAL AS REQUIRED. DO NOT CUT CORD OF PENDANT UNTIL EXACT HEIGHT IS FINALIZED. 5. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 6. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY- OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 7. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 8. DECORATIVE FIXTURE(S) SPECIFIED ARE TO BE PURCHASED THRU LOCAL COMMERCIAL VENDOR TO INSURE COMMERCIAL WARRANTIES. PURCHASING FROM OTHER VENDORS OR AVENUES IS AT THE SUPPLIER'S / EC'S RISK NOT, THE PARALLEL DESIGN GROUP'S, OWNER'S, OR TENANT'S. GENERAL NOTES MECHANICAL NOTES KEYED NOTES 1. SCOPE INTENT IS FOR EXISTING MECHANICAL SYSTEMS TO REMAIN. EXISTING FLEX DUCT AND DIFFUSERS BEING RELOCATED AS NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED. 2. DIFFUSER LOCATIONS ARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. 3. FIRE STOP ANY EXISTING DECK PENETRATIONS AS REQUIRED. 4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 5. WHERE EXPOSED DECK IS SHOWN, VERIFY WITH DESIGNER AND TENANT IF DUCT WORK SHOULD BE SPIRAL DUCT. 2'x2' LED MATCH EXISTING EXISTING LINEAR FIXTURE TO REMAINEXL CEILING TYPE CEILING HEIGHT ACT -2' x 2' ACOUSTICAL CEILING TO MATCH EXISTING IN SUITE NOTE: ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED WITH 6" (OR MATCH EXISTING SIZE) WHITE AXIOM TRIM UNLESS NOTED OTHERWISE. DECK-EXPOSED DECK PAINT AS NOTED ON PLAN WITH DRY FALL PAINT. PAINT 10' BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE. NEW CEILING GRID, SUSPENDED, 2'x2' NEW GYPSUM BOARD CEILING EXISTING CEILING GRID, SUSPENDED, 2'x2' EXISTING GYPSUM BOARD X X' -X" EXPOSED DECK DIFFUSER, LAY-IN, 2'x2' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 4"x4' AREA NOT IN CONTRACT AREA OF WORK NEW SUSPENDED LINEAR LED MATCH EXISTING STYLE AND INSTALL HEIGHT LENGTH VARIES; SEE DIMENSIONS ON PLAN NL PENDANT, LED MFG: REJUVENATION STYLE: 24" CONICAL DRUM PENADANT FINISH: AGED BRASS WITH WHITE SHADE ITEM #A4379 MOUNTING HEIGHT: BOTTOM OF FIXTURE AT 8'-0" A.F.F. P1 WALL SCONCE MFG: LIGHTOLOGY STYLE: IC WALL MFR ID: FU317835 ITEM #: FLO967642 SIZE: 11.8" FINISH: RED BURGUNDY MOUNTING HEIGHT: MIDDLE OF FIXTURE AT 5'-6" A.F.F.EXLEXL EXL EXL EXL EXL EXL EXL EXLEXLEXLEXLEXLEXLEXLEXL EXL 1 1 1 1 1 1 1 2 2 1 3 1 1 1 1 ELEL ELEL EL 4 1 EXIST DECK 6 NL NL NL 5 NEW DECK 47 7 7 8 10 EQ. EQ.EQ. EQ. EQ. EQ. NL NL P1 P1 P1 P1 10' - 0" 10' - 0"18' - 6"20' - 0"± 18' - 6"6 EXL 9 12 ' - 0"± 9 5' - 6" EQ. EQ. EQ. 5' - 6" 11 11 MECHANICAL DIFFUSER RELOCATION NOT TO SCALE *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELOCATE DIFFUSERS AND FLEX DUCT IF REQUIRED VAV/ HEAT PUMPEXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A201 REFLECTED CEILING PLAN 1 NO WORK IN THIS AREA. EXISTING CEILING, LIGHTING, SWITCHES AND HVAC DIFFUSERS TO REMAIN. 2 EXISTING CEILING AND LIGHTING TO REMAIN. PROVIDE NEW SWITCH TO CONTROL EXISTING FIXTURES IN THIS ROOM. RELOCATE EXISTING DIFFUSERS AS REQUIRED, PER NEW WALL LAYOUT. 3 PROVIDE NEW LIGHT FIXTURE TO MATCH EXISTING. TIE INTO EXISTING SWITCHES/CONTROLS. 4 WHERE EXISTING CEILING GRID/TILE WAS REMOVED, CEILING IS TO BE EXPOSED TO EXISTING DECK. CLEAN UP EXPOSED CEILING OF ANY LOOSE WIRES, ABANDONED CABLE OR UNUSED ITEMS. CEILING TO BE PAINTED TO MATCH ADJACENT EXISTING EXPOSED CEILING. 5 EXISTING ACCENT COLORED EXPOSED DECK TO BE PAINTED WITH DRYFALL PAINT TO MATCH EXISTING GRAY CEILING COLOR IN THE MAJORITY OF THE SUITE. 6 CONTROL LIGHTING IN THIS ROOM WITH 3-WAY DIMMER SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. 7 NEW LIGHT FIXTURE TO BE CONTROLLED BY EXISTING SWITCHES FOR OPEN OFFICE AREA. 8 WHERE EDGE OF EXISTING DRYWALL CEILING IS NEWLY EXPOSED, PROVIDE 6" (OR MATCH EXISTING SIZE) WHITE AXIOM TRIM ALONG ENTIRE VERTICAL EDGE. AREA ABOVE DRYWALL CEILING TO BE SPRINKLERED AS REQUIRED BY CODE. 9 INTENT IS FOR PORTION OF EXISTING RECESSED LINEAR LIGHT TO REMAIN IN EXISTING BULKHEAD AND BE CONTROLLED BY EXISTING SWITCHES FOR OPEN OFFICE AREA. COORDINATE WITH DESIGNER IF THIS IS NOT POSSIBLE. 10 ENTIRE EXPOSED DECK IN THIS ROOM TO BE PAINTED WITH DRYFALL PAINT TO MATCH EXISTING GRAY CEILING COLOR IN THE MAJORITY OF THE SUITE. REMOVE ALL UNUSED WIRES AND EQUIPMENT WHERE EXISTING DRYWALL CEILING AND PORTION OF LIGHT FIXTURE WERE REMOVED. 11 NEW LIGHT FIXTURE TO BE HUNG AT 9'-9" AFF. 1/8" = 1'-0" REFLECTED CEILING PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 DED +44GFI+42TV1 +60+60+60+60+60+60J J J +44 +44GFI +42 GFI +42 J J JJTV1 J J 1. ALL OUTLETS, DEVICES, AND FACEPLATES TO MATCH EXISTING. 2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TEMINAL AT FACE PLATE. 3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI. 4. TENANT TO SUPPLY, INSTALL AND PAY FOR SECURITY SYSTEMS (I.E. MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL ROOM. 5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. 6. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. GENERAL NOTESLEGEND POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX WALL MOUNTED JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN P POWER AND DATA POLE FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED NEW DEDICATED CIRCUIT GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE N DED GFI +44" B O J DATA TV1 DUPLEX AND DATA AT +60" AFF KEYED NOTES J AREA NOT IN CONTRACT AREA OF WORK TV2 DUPLEX, DATA AND HDMI AT +60" AFF TV3 DUPLEX, DATA AND CABLE AT +60" AFF LOBBY 100 STORAGE 101 IT 102 CONFERENCE 103 CONFERENCE 104 OPEN OFFICE 105 COFFEE 106 PHONE 107 PHONE 108 PHONE 109 OFFICE 113 CONFERENCE 114 HUDDLE 115 1 1 1 1 1 8 1 2 3 5 5 5 4 4 PHOTO/VIDEO 112 WELLNESS 111 6 7 7 6 4 4 9 9 10 NNN N N NN NN N N N N [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A301 POWER AND DATA PLAN 1/8" = 1'-0" POWER & DATA PLAN1 1 NO WORK IN THIS AREA; EXISTING ELECTRICAL TO REMAIN. 2 CONFIRM ALL ELECTRICAL REQUIREMENTS AND LOCATIONS WITH TENANT. 3 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. 4 IF POSSIBLE, REUSE EXISTING RECESSED FLOOR CORE FOR TENANT'S FURNITURE SYSTEM. IF FLOOR CORE IS NOT IN ACCEPTABLE LOCATION, REMOVE AND PROVIDE NEW. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH TENANT'S FURNITURE VENDOR. 5 IF REQUIRED, PROVIDE RECESSED FLOOR CORE WITH JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH TENANT'S FURNITURE VENDOR. INTENT IS TO REUSE EXISTING FLOOR CORES BEFORE PROVIDING NEW IF POSSIBLE. 6 PROVIDE POWER AND DATA FOR TENANT PROVIDED WALL MOUNTED TV. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT. 7 PROVIDE POWER FOR TENANT PROVIDED UNDER COUNTER FRIDGE. CONFIRM EXACT REQUIREMENTS WITH TENANT. 8 CONFIRM THAT EXISTING ELECTRICAL IS SUFFICIENT FOR TENANT PROVIDED APPLIANCES. PROVIDE ADDITIONAL POWER AS REQUIRED. CONFIRM EXACT REQUIREMENTS WITH TENANT. 9 PROVIDE RECESSED FLOOR CORE FOR POWER AND DATA FOR TENANT PROVIDED FURNITURE. CONFIRM EXACT REQUIREMENTS AND LOCATION WITH TENANT AND FURNITURE VENDOR. 10 IS POSSIBLE, REUSE EXISTING JUNCTION BOX FOR TENANT PROVIDED DESK IN THIS ROOM. CONFIRM EXACT REQUIREMENTS AND LOCATION WITH TENANT.REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21 LOBBY 100 LVT1 EX EX STORAGE 101 EX EX EX IT 102 EX EX EX CONFERENCE 103 CPT1 PT1 VB2 CONFERENCE 104 EX EX EX OPEN OFFICE 105 EX EX EX COFFEE 106 EX EX EX PHONE 107 EX EX EX PHONE 108 EX EX EX PHONE 109 EX EX EX OFFICE 113 EX EX EX CONFERENCE 114 EX EX EX HUDDLE 115 CPT1 EX EXEXISTING CARPET TO REMAINNEW CARPET (CPT1)PT1+VB1PT1 + VB1 PT1 + VB1WELLNESS 111 EX PT1 VB2 PHOTO/VIDEO 112 EX PT1 VB2 EXISTING CARPET TO REMAINNEW LVT (LVTX)1 1 1 1 1PT2 +VBX2 PTX PTXPT1 + VB1 PT1 + VB1 PT1 + VB1WT1 4 2 1 VB13 3 3 3 5 PT2 +VBXPT2 +VBXFINISH SPECIFICATIONS CARPET MFG: TARKETT TYPE: 4" ROLL STOCK VINYL WALL BASE COLOR: MATCH EXISTING IN SUITE WALL BASE MFG: SHERWIN WILLIAMS COLOR: PURE WHITE SW7005 PAINT MFG: SHERWIN WILLIAMS COLOR: DEEP SEA DIVE SW7618 ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS & COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE CPT1 VB1 PT1 PT2 MFG: XXX COLOR: XXX MILL/CASEWORK FINISHES PL1 MFG: XXX COLOR: XXX SS1 EX EXISTING FINISH TO REMAIN; TOUCH UP AS REQUIRED MFG: WOW SIZE: 3" X 12" PATTERN: STRIPES COLOR: MATTE GRAPHITE INSTALLATION: VERTICAL STACKED BOND GROUT: TEC COLOR RAVEN 941 LOCATION: ENTIRE WALL, FLOOR TO CEILING CONTACT: TRACEY KESSINS 317.366.2835 WALL TILE WT1 MFG: XXX PATTERN: XXX COLOR: XXX CONTACT: XXX WALLCOVERING WC1 MATCH EXISTING IN SUITE MFG: SHERWIN WILLIAMS COLOR: IRON ORE SW7069 PT3 MFG: TARKETT TYPE: 4" ROLL STOCK VINYL WALL BASE COLOR: XXX VB3 MFG: TARKETT TYPE: 4" ROLL STOCK VINYL WALL BASE COLOR: XXX VB2 CPT2 MFG: MILLIKEN STYLE: COLOR THESIS PATTERN: ARTWORK COLOR: TAUPE SHADOW (RUG: ATR235-10-145) SIZE: 1M X 1M INSTALLATION: RUG PATTERN LAYOUT BELOW CONTACT: MCKENZIE SWIHART 317.460.8068 MFG: XXX COLOR: XXX PL2 LUXURY VINYL TILE LVT1 MFG: PATTERN: COLOR: SIZE: INSTALLATION: CONTACT: 1. UNLESS NOTED OTHERWISE, ALL EXISTING FINISHES TO REMAIN. CLEAN AND REPAIR AS REQUIRED. 2. ALL AREAS RECEIVING PAINT ARE TO RECEIVE A THREE-COAT SYSTEM, PRIMER COAT AND TWO (2) FINISH COATS. 3. THE FINISHES AT TIME OF THE ISSUE DATE HAVE BEEN CHECKED AND ARE AVAILABLE UNLESS OTHERWISE NOTED. WALLCOVERING, CARPET, CERAMIC TILE AND SPECIALTY ITEMS CAN BE UP TO 6-8WEEK LEAD TIME. PARALLEL DESIGN GROUP STRONGLY RECOMMENDS ORDERING FINISHES IMMEDIATELY TO ENSURE TIMELY DELIVERY FOR AN ON- TIME INSTALLATION. 4. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 5. ALL FINISHES AND SPECIFICATIONS ARE TO BE SUBMITTED TO PARALLEL DESIGN GROUP FOR FINAL APPROVAL PRIOR TO ORDERING FINISH MATERIALS. 6. PT1 AND VB1 TO BE USED THROUGHOUT UNLESS OTHERWISE NOTED. 7. REPRESENTS DIRECTION OF FLOORING 8. IF UNDERCABINET LAMINATE BASE CONTAINS A GAP(S) GREATER THAN OR EQUAL TO 1/8" BETWEEN FINISH FLOOR, CONTRACTOR TO ALSO INSTALL SHOE MOLDING. 9. PROVIDE LEVEL 5 DRYWALL FINISH ON ALL WALLS RECEIVING DARK PAINT OR WHITEBOARD PAINT. SEE PAINT MANUFACTURER'S INSTRUCTIONS FOR RECOMMENDED DRYWALL FINISH LEVEL. 10. PAINTED SHEEN LEVEL TO BE AS LISTED BELOW, U.N.O.: WALLS: EGG-SHELL PAINTED DOORS AND FRAMES: SEMI-GLOSS WET AREA WALLS: EPOXY DRYWALL CEILINGS: FLAT EXPOSED DECK CEILINGS: DRYFALL GENERAL NOTES FINISH PLAN TAG ROOM NAME ROOM NUMBER FLOOR BASE WALL KEYED NOTES 1/8" = 1'-0" FINISH PLAN1 [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A401 FINISH PLAN 1 ENTIRE COLUMN TO BE PAINTED (PTX). 2 ACCENT COLOR EXPOSED CEILING IN THIS ROOM TO BE PAINTED WITH DRYFALL PAINT TO MATCH EXISTING GRAY COLOR ON THE MAJORITY OF THE EXPOSED DECK CEILING. 3 ALL FACES AND EDGES OF WALLS AND BULKHEADS TO BE PAINTED (PT3). PROVIDE NEW VINYL BASE (VB2). 4 WHERE POLISHED CONCRETE CURRENTLY EXISTS, REMOVE EXISTING TRANSITION STRIP AND PROVIDE NEW CARPET (CPT1) TO MATCH EXISTING ADJACENT CARPET. INTENT IS FOR NEW CARPET TO ALIGN AND BE INSTALLED IN SAME ORIENTATION AS EXISTING CARPET SO THAT NEW AND EXISTING CARPET APPEARS CONTINUOUS. 5 REMOVE EXISTING WHITE VINYL BASE ON ENTIRE TOE-KICK OF CABINETS AND REPLACE WITH NEW BROWN VINYL BASE TO MATCH LAMINATE ON EXISTING BASE CABNINETS. CONFIRM EXACT COLOR WITH TENANT.REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21