Loading...
HomeMy WebLinkAboutA010.0DOOR HARDWARE AFB AUTOMATIC FLUSH BOLT CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) CL CLOSER DB DEADBOLT DL DUMMY LEVER ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KS KICK STOP KF KEY FOB KP KICK PLATE KS KICK STOP ML MAGNETIC LOCK OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES GENERAL NOTES 1. DOORS:REUSE DOORS FROM DEMOLITION WHERE POSSIBLE. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. FRAMES: REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 3. HARDWARE:REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. PROVIDE NEW HARDWARE ON NEW DOORS AS NOTED ON SCHEDULE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING STANDARD A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 4. CONTRACTOR TO VERIFY THAT NO HOLES/OPENINGS ARE IN EXISTING DOOR DUE TO HARDWARE CHANGES. IF HOLES ARE PRESENT THAT WILL NOT BE FILLED BY NEW HARDWARE, CONTRACTORS TO CONTACT PARALLEL DESIGN GROUP TO CONFIRM ON HOW TO MOVE FORWARD. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. DOOR TYPESFRAME TYPES 1/4" TEMPERED GLASS F1 F2 D1D22"SEE SCHEDULE 2"SEE SCHED.2" 2' - 0" 2" 2"SEE SCHEDULE 2" SEE SCHED. 2" SEE SCHEDULESEE SCHED.SEE SCHEDULESEE SCHED. REMARK 1. PROVIDE ALL REQUIRED HARDWARE AND TRACKS FOR WALL RECESSED POCKET DOOR. PROVIDE RECESSED FINGER PULL. CONFIRM EXACT STYLE WITH TENANT, FINISH TO MATCH SUITE STANDARD. D3 8' - 0"4' - 0" 2"SEE SCHEDULE 2" SEE SCHED. 2" F3 RUSTICA FRENCH QUARTER SINGLE POCKET DOOR CLEAR GLASS RUSTICA POCKET DOOR FRAME COLOR: GREY STEEL MILL/CASEWORK NOTES 1. CAULK SELECTIONS ARE TO BE PROVIDED TO PARALLEL DESIGN GROUP FOR SELECTION AND/OR APPROVAL BEFORE INSTALLATION OF MILLWORK. 2. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO PARALLEL DESIGN GROUP FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 3. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 4. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 5. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND PARALLEL DESIGN GROUP PRIOR TO FABRICATION. PROVIDE SEAMING DIAGRAM TO PARALLEL DESIGN GROUP. 6. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO PARALLEL DESIGN GROUP THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. UNLESS NOTED OTHERWISE ON ELEVATIONS, FILLER PANELS SHALL NOT EXCEED 3" ON EACH SIDE OF CABINETS. 7. UNLESS OTHERWISE SHOWN, PROVIDE 25" DEEP, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 8. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS FOR THE PARTICULAR APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT CHOICES TO PARALLEL DESIGN GROUPS FOR FINAL DECISIONS. 9. PROVED CABINETRY HARDWARE: MFG: SCHAUB AND COMPANY PRODUCT: 79-6-BBZ SIZE: 6" CENTER TO CENTER FINISH: BRUSHED BRONZE MILL/CASEWORK LEGEND EQUIPMENT -BY OTHERS UNDER CABINET LIGHT. REFER TO REFLECTED CEILING PLAN, APPLY 2" LAMINATED APRON LOCKABLE CABINETS AND DRAWERS. CONFIRM REQUIREMENTS WITH TENANT 24"D PLASTIC LAMINATE ROLL OUT TRASH CABINET, DOUBLE-BIN, GENERAL CONTRACTOR TO PROVIDE TRASH BINS EQ UL L T 1' - 3" 1' - 3" 2' - 6" 2' - 6"3' - 0"1' - 9" 3' - 0" T 24"D PLASTIC LAMINATE (PLX) BASE CABINETS PLASTIC LAMINATE (PLX) FILLER PANEL AT WALL VINYL BASE (VB1) 25"D PLASTIC LAMINATE (PLX) COUNTERTOP, 4"H SIDE AND BACKSPLASH 7' - 7" 2' - 6" 2' - 6" 2' - 6" 24"D PLASTIC LAMINATE (PLX) UPPER CABINETS UNDER COUNTER FRIDGE PROVIDED BY TENANT 24"D PLASTIC LAMINATE (PLX) BASE CABINETS PLASTIC LAMINATE (PLX) FILLER PANEL AT WALL VINYL BASE (VB1) 25"D PLASTIC LAMINATE (PLX) COUNTERTOP, 4"H SIDE AND BACKSPLASH 2' - 10"2' - 0" 3' - 3" 3' - 3" NEW TOP MOUNT SINK AND FAUCET; SEE FLOOR PLAN FOR EXACT SPEC 6' - 7 1/8"8' - 7"8' - 7" 1' - 0" 11 1/2" EXISTING WOOD PLATFORM 3/8" TEMPERED GLASS 2" BLACK METAL FRAME BLACK METAL FRAME MULLIONS (4 COLUMNS, 4 ROWS, EQUAL SPACING) ALIGN BOTTOM OF FRAMES 6' - 0" 6' - 0"6' - 0"3' - 6" 3" 6' - 0" 3"3' - 0" 1' - 8" 2' - 6" 4"GLASS FRONT REF. BY TENANT T COFFEE BY TENANT 1' - 7 1/4" 2' - 6" 2' - 6" 2' - 6" EQ EQ 24"D PLASTIC LAMINATE (PLX) BASE CABINETS VINYL BASE (VB1) FULL HEIGHT SOLID SURFACE (SS1) BACK AND SIDESPLASH PLASTIC LAMINATE (PL1) PANEL FLUSH WITH FRONT FACE OF CABINETS 12"D PLASTIC LAMINATE (PLX) UPPER CABINETS 12" DEEP x 1" THICK PLASTIC LAMINATE (PLX) SHELVES 25"D SOLID SURFACE (SS1) COUNTERTOP1' - 8" 10" 10" 10" 1" 1' - 6 1/4" 2' - 6" 2' - 6" 2' - 6" 1' - 8" 10" 10" 10" EQ 1' - 6" 3' - 1" 24"D PLASTIC LAMINATE (PLX) UPPER CABINET 24"D PLASTIC LAMINATE (PLX) PANEL PLASTIC LAMINATE (PLX) SURROUND AT FRIDGE FOR BUILT-IN APPEARANCE; PANELS TO BE FLUSH WITH 24" DEEP CABINET ABOVE; CONFIRM EXACT FRIDGE DIMENSIOSN WITH TENANT [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A110 DOOR SCHEDULE & INTERIOR ELEVATIONS DOOR SCHEDULE DOOR NUMBER ROOM PAIR POWER REQUIRED DOOR FRAME REMARKSWIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE SET 104A CONFERENCE 3' - 0" x 8' - 0" x1 3/4" D2 WOOD MATCH EXISTING F1 MATCH EXISTING MATCH EXISTING PS 104B CONFERENCE 4' - 0" x 8' - 0" x1 3/4" D3 STEEL STEEL F3 STEEL GREY STEEL SEE REMARK 1 111 WELLNESS 3' - 0" x 8' - 0" x1 3/4" D1 WOOD MATCH EXISTING F1 MATCH EXISTING MATCH EXISTING CH, PL 112 PHOTO/VIDEO 3' - 0" x 8' - 0" x1 3/4" D1 WOOD MATCH EXISTING F2 MATCH EXISTING MATCH EXISTING PS 1/2" = 1'-0" COPY 11011/2" = 1'-0" WELLNESS 111 2 1/2" = 1'-0" CONFERENCE 10331/2" = 1'-0" COFFEE 1064 REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21