HomeMy WebLinkAboutE100.0DED
+44GFI+42TV1
+60+60+60+60+60+60J
J
J +44 +44GFI
+42
GFI
+42
J
J JJTV1
J
J
1. ALL OUTLETS, DEVICES, AND FACEPLATES TO MATCH EXISTING.
2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE
TEMINAL AT FACE PLATE.
3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI.
4. TENANT TO SUPPLY, INSTALL AND PAY FOR SECURITY SYSTEMS (I.E.
MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN
SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL
ROOM.
5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE.
6. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC
STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT
SPECIFIED BY PARALLEL DESIGN GROUP.
GENERAL NOTESLEGEND
POWER OUTLET, DUPLEX
POWER OUTLET, QUADRUPLEX
WALL MOUNTED JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
P POWER AND DATA POLE
FLOOR BOX WITH JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER AND DATA,
FLUSH MOUNTED
NEW
DEDICATED CIRCUIT
GROUND FAULT CIRCUIT INTERRUPT OUTLET
HEIGHT OF ELECTRICAL OR DATA DEVICE
N
DED
GFI
+44"
B
O
J
DATA
TV1 DUPLEX AND DATA AT +60" AFF
KEYED NOTES
J
AREA NOT IN CONTRACT
AREA OF WORK
TV2 DUPLEX, DATA AND HDMI
AT +60" AFF
TV3 DUPLEX, DATA AND CABLE
AT +60" AFF
LOBBY
100
STORAGE
101
IT
102
CONFERENCE
103
CONFERENCE
104
OPEN OFFICE
105
COFFEE
106
PHONE
107
PHONE
108
PHONE
109
OFFICE
113 CONFERENCE
114
HUDDLE
115
1 1
1
1
1
8
1
2
3
5
5
5 4
4
PHOTO/VIDEO
112
WELLNESS
111
6
7
7
6
4
4
9
9
10
N
N
N
N
N NN NN
N
N N N
[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502021.16204.15.21SFKBELEMENT THREEMIDTOWN EAST -1ST FLOOR571 MONON BLVD, CARMEL, INDIANA 46032A301
POWER AND DATA
PLAN
1/8" = 1'-0"
POWER & DATA PLAN1
1 NO WORK IN THIS AREA; EXISTING ELECTRICAL TO REMAIN.
2 CONFIRM ALL ELECTRICAL REQUIREMENTS AND LOCATIONS WITH
TENANT.
3 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
4 IF POSSIBLE, REUSE EXISTING RECESSED FLOOR CORE FOR
TENANT'S FURNITURE SYSTEM. IF FLOOR CORE IS NOT IN
ACCEPTABLE LOCATION, REMOVE AND PROVIDE NEW.
COORDINATE EXACT LOCATION AND REQUIREMENTS WITH
TENANT'S FURNITURE VENDOR.
5 IF REQUIRED, PROVIDE RECESSED FLOOR CORE WITH JUNCTION
BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE
EXACT LOCATION AND REQUIREMENTS WITH TENANT'S FURNITURE
VENDOR. INTENT IS TO REUSE EXISTING FLOOR CORES BEFORE
PROVIDING NEW IF POSSIBLE.
6 PROVIDE POWER AND DATA FOR TENANT PROVIDED WALL
MOUNTED TV. CONFIRM EXACT LOCATION AND REQUIREMENTS
WITH TENANT.
7 PROVIDE POWER FOR TENANT PROVIDED UNDER COUNTER FRIDGE.
CONFIRM EXACT REQUIREMENTS WITH TENANT.
8 CONFIRM THAT EXISTING ELECTRICAL IS SUFFICIENT FOR TENANT
PROVIDED APPLIANCES. PROVIDE ADDITIONAL POWER AS
REQUIRED. CONFIRM EXACT REQUIREMENTS WITH TENANT.
9 PROVIDE RECESSED FLOOR CORE FOR POWER AND DATA FOR
TENANT PROVIDED FURNITURE. CONFIRM EXACT REQUIREMENTS
AND LOCATION WITH TENANT AND FURNITURE VENDOR.
10 IS POSSIBLE, REUSE EXISTING JUNCTION BOX FOR TENANT
PROVIDED DESK IN THIS ROOM. CONFIRM EXACT REQUIREMENTS
AND LOCATION WITH TENANT.REVISION SCHEDULEMARK DATE DESCRIPTION07/26/21