Loading...
HomeMy WebLinkAboutA8 Cross Section1'-4 3/4" GRANULAR FILL11'-0" REINFORCED POURED CONCRETE WALL9'-5 1/2" 8'-2 1/4"GRANULAR FILL12'-1 1/8" 12'-1 1/8" WALL HT.FUTURE BEDROOM HVAC / STORAGE 4" REINFORCED CONCRETE SLAB 4" GRANULAR FILL INTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT VAPOR BARRIER 22" WIDE BY 10" DEEP POURED CONCRETE FOOTING WITH 3-#4 REBAR CONTINUOUS 2" X 6" CONTINUOUS TREATED WOOD PLATE 2" X 6" WOOD STUDS AT 16" O.C. EXPANSION STRIP 6" BATT INSULATION R-19 FUTURE 1/2" GYPSUM BOARD FUTURE 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" X 10" ANCHOR BOLTS AT 6'-0" O.C. MAX. AND 12" IN FROM ALL CORNERS FINISHED GRADE VARIES 45 MIL. EPDM RUBBER FLASHING MEMBRANE 5 1/2" X 8" LEDGE SOUND INSULATION EXTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT GRANULAR FILL WATERPROOFING #4 DOWEL AT 24" O.C. 10" POURED CONCRETE BASEMENT WALL WITH MIN. #4 REBAR GRID AT 24" O.C. EACH WAY WALL PANELS WITH RAINSCREEN SYSTEM - SEE ELEVATIONS FOR EXACT LOCATIONS 3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED 2" X 6" CONTINUOUS WOOD PLATE WOOD BASE TBD. VAPOR BARRIER 2" X 6" STUDS AT 16" 0.C. TYP. ALUMINUM SILL ENGINEERED FLOOR JOISTS AT 16" O.C. VERIFY SIZE WITH G.C. 6" BATT INSULATION R-19 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES SOUND INSULATION 3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED 2" X 6" CONTINUOUS WOOD PLATE WOOD BASE TBD. VAPOR BARRIER 2" X 6" STUDS AT 16" 0.C. TYP.1'-4 3/4"ENGINEERED FLOOR JOISTS AT 16" O.C. VERIFY SIZE WITH G.C. FUTURE WIC. FUTURE STUD WALLS COLUMN FOOTING PAD BEYOND - SEE FOUNDATION PLAN 6" BATT INSULATION R-19 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" EXTERIOR SHEATHING 3/4" X 5 1/2" T&G WOOD PLANKING SOFFIT 2" X FRAMING FIBER CEMENT 1" X 16" FASCIA 2" X SUB-FASCIA CONTINUOUS ALUMINUM GUTTER CONTINUOUS SOFFIT VENT CONTINUOUS ALUMINUM ROOF EDGE 7/16" OSB ROOF SHEATHING ROOF PROTECTION MEMBRANE AS RECOMMENDED FOR METAL ROOFING STANDING SEAM METAL ROOF 12SEE ROOF PLAN FIBER CEMENT 1" X 2" TRIM FIBER CEMENT FLUTED PANELS BREAK ALUMINUM FLASHING CAP 3/4" T&G PLYWOOD SUB-FLOOR GLUED AND SCREWED 2" X 6" CONTINUOUS WOOD PLATE WOOD BASE TBD. VAPOR BARRIER 2" X 6" STUDS AT 16" 0.C. TYP. ENGINEERED FLOOR JOISTS AT 16" O.C. VERIFY SIZE WITH G.C. 6" BATT INSULATION R-19 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" EXTERIOR SHEATHING 3/4" X 5 1/2" T&G WOOD PLANKING SOFFIT 2" X FRAMING FIBER CEMENT 1" X 16" FASCIA 2" X SUB-FASCIA CONTINUOUS ALUMINUM GUTTER CONTINUOUS SOFFIT VENT CONTINUOUS ALUMINUM ROOF EDGE 7/16" OSB ROOF SHEATHING ROOF PROTECTION MEMBRANE AS RECOMMENDED FOR METAL ROOFING STANDING SEAM METAL ROOF 12 SEE ROOF PLAN 11'-0"WINE / BAR AREA MASTER BEDROOM GREAT ROOM MASTER BATHROOM STEEL BEAM G.C. VERIFY SIZE GRANULAR FILL4" REINFORCED CONCRETE SLAB 4" GRANULAR FILLINTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT VAPOR BARRIER 22" WIDE BY 10" DEEP POURED CONCRETE FOOTING WITH 3-#4 REBAR CONTINUOUS 2" X 6" CONTINUOUS TREATED WOOD PLATE 2" X 6" WOOD STUDS AT 16" O.C. EXPANSION STRIP 6" BATT INSULATION R-19 FUTURE 1/2" GYPSUM BOARD FUTURE 1/2" GYPSUM BOARD 2- 2" X 6" TOP PLATES 1/2" X 10" ANCHOR BOLTS AT 6'-0" O.C. MAX. AND 12" IN FROM ALL CORNERS FINISHED GRADE VARIES 45 MIL. EPDM RUBBER FLASHING MEMBRANE 5 1/2" X 8" LEDGE SOUND INSULATION EXTERIOR PERIMETER DRAIN TILE SIZE BY G.C. RUN TO SUMP PIT GRANULAR FILL WATERPROOFING #4 DOWEL AT 24" O.C. 10" POURED CONCRETE BASEMENT WALL WITH MIN. #4 REBAR GRID AT 24" O.C. EACH WAY ALUMINUM SILL STEAM SHOWER MODELNUMBERTRADENAMEPRODUCT 10'-1 1/8"8'-1 1/8" 2'-0"WALL PANELS WITH RAINSCREEN SYSTEM - SEE ELEVATIONS FOR EXACT LOCATIONS WALL PANELS WITH RAINSCREEN SYSTEM - SEE ELEVATIONS FOR EXACT LOCATIONS AIR AND MOISTURE BARRIER AIR AND MOISTURE BARRIER METAL FIREPLACE WITH GAS SIZE TO BE SELECTED FLOATING BLUE STEEL HEARTH TBD 1'-6"1'-8 1/2"floor finish tbs.2 1/4"22'-6 1/2" 1'-4 3/4" 1'-2 1/4"STEEL BEAM G.C. VERIFY SIZE10'-7 7/8" G.C. VERIFY STEEL BEAM SIZEDROPPED CEILING CLOUD - VERIFY W/ INTERIOR DESIGNER LED INDIRECT LIGHTING - VERIFY W/ INTERIOR DESIGNER ATTIC METAL CAP 1/2" EXTERIOR SHEATHING 1/2" EXTERIOR SHEATHING 2019-0805 04-12-2021 "ISSUED FOR CONSTRUCTION" Project No: Sheet Title REVISIONS Date: Sheet No.GARY NANCE DESIGNArchitectural Concepts By4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignA R C H I T E C T S+A S S O C I A T E S2520 Durbin DriveCarmel , Indiana 46032317-733-8525hsark@sarkassociates.com12621 Chyverton CircleCarmel, IN 46032MB1A New Residence for:CROSS SECTION - TWO STORY SCALE: 1/2" = 1'-0" WALL SECTIONS A-81 A-8 U:\02-RESIDENTIAL L-Z\Nance, G\2018-0912_MB1\01-Current CDs\2021-0303_MB1_Wall Sections.dwg, 6/7/2021 7:35:24 AM,_DWG To PDF.pc308/27/21