Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19 Estates at Towne Meadow - Seals
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). August 4,2021 Liu, Xuegang Pages or sheets covered by this seal: I47311480 thru I47311537 My license renewal date for the state of Indiana is July 31, 2022. 19_Estates_at_Towne_Meadow 19 Estates at Towne Meadow IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE01 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311480 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:10 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-jDyInZOfKyNu5ddnCj_4Qi8dNZcQA4DYzTBDaGyrCKR Scale = 1:82.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 60 59 58 57 56 55 54 53 52 51 50 4948 47 46 45 4443 42 41 40 39 38 37 36 35 34 33 32 3x4 3x4 5x6 5x6 5x6 3x4 3x4 3x6 3x6 35-11-035-11-0 -0-11-0 0-11-0 17-11-8 17-11-8 35-11-0 17-11-8 36-10-0 0-11-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [6:0-2-12,0-3-4], [26:0-2-12,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.08 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 31 31 32 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 762 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 16-46,15-47,14-49,17-45,18-43: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 16-46, 15-47, 14-49, 13-50, 12-51, 11-52, 17-45, 18-43, 19-42, 20-41, 21-40 REACTIONS.All bearings 35-11-0. (lb) - Max Horz 60=-248(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 32, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34 except 60=-115(LC 6), 59=-130(LC 10), 33=-114(LC 11) Max Grav All reactions 250 lb or less at joint(s) 60, 32, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 45, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-14=-157/264, 14-15=-180/300, 15-16=-182/303, 16-17=-182/303, 17-18=-180/300, 18-19=-157/264 WEBS 16-46=-267/135 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 1-11-8, Exterior(2N) 1-11-8 to 14-11-8, Corner(3R) 14-11-8 to 20-11-8, Exterior(2N) 20-11-8 to 33-10-0, Corner(3E) 33-10-0 to 36-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 32, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34 except (jt=lb) 60=115, 59=130, 33=114. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE02 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311481 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-7oeQPaQYdtlSy4MMtrYn2Km86nd1NRw_gRQuBbyrCKO Scale = 1:78.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 58 57 56 55 54 53 52 51 50 49 48 474645 44 434241 40 39 38 37 36 35 34 33 32 31 30 3x4 3x4 5x6 5x6 5x6 3x4 3x4 3x6 3x6 35-11-035-11-0 17-11-8 17-11-8 35-11-0 17-11-8 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [5:0-2-12,0-3-4], [25:0-2-12,0-3-4], [30:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.16 0.09 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 30 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 759 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 15-44,14-45,13-47,16-43,17-41: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-44, 14-45, 13-47, 12-48, 11-49, 10-50, 16-43, 17-41, 18-40, 19-39, 20-38 REACTIONS.All bearings 35-11-0. (lb) - Max Horz 58=235(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 30, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32 except 58=-115(LC 6), 57=-120(LC 10), 31=-109(LC 11) Max Grav All reactions 250 lb or less at joint(s) 58, 30, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 43, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 12-13=-171/266, 13-14=-195/302, 14-15=-195/305, 15-16=-195/305, 16-17=-195/302, 17-18=-171/266 WEBS 15-44=-269/148 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-4 to 3-3-8, Exterior(2N) 3-3-8 to 14-11-8, Corner(3R) 14-11-8 to 20-11-8, Exterior(2N) 20-11-8 to 32-7-8, Corner(3E) 32-7-8 to 35-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32 except (jt=lb) 58=115, 57=120, 31=109. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE03 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311482 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-3BmBqGSo9V?ABOVk?GaF7lsTzaKDrLwH7lv_GUyrCKM Scale = 1:36.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-11-010-11-0 -1-0-0 1-0-0 5-5-8 5-5-8 10-11-0 5-5-8 11-11-0 1-0-0 1-3-05-9-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.04 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-11-0. (lb) - Max Horz 20=-123(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 2-5-8, Corner(3R) 2-5-8 to 8-5-8, Exterior(2N) 8-5-8 to 8-11-0, Corner(3E) 8-11-0 to 11-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE04 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311483 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:16 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-XNKZ1cTQwo71pY4xZz5UfzOem_gIamPQMPeYowyrCKL Scale = 1:42.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 26 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-11-013-11-0 -1-0-0 1-0-0 6-11-8 6-11-8 13-11-0 6-11-8 14-11-0 1-0-0 1-3-07-0-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.05 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 186 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-11-0. (lb) - Max Horz 24=-146(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-108/252, 7-8=-108/252 WEBS 7-19=-257/72 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-11-8, Corner(3R) 3-11-8 to 9-11-8, Exterior(2N) 9-11-8 to 11-11-0, Corner(3E) 11-11-0 to 14-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE05 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311484 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:18 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-UmRJSIUgRQNl2rEJgO7ylOUu8oFp2fRjpi7fsoyrCKJ Scale = 1:76.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 89 21 20 19 17 16 15 14 13 12 11 10 58 59 18 3x6 5x6 3x4 3x6 3x4 3x6 3x6 3x6 3x8 5x8 3x6 3x6 5x6 8-5-138-5-13 14-11-06-5-3 16-9-31-10-3 25-3-08-5-13 -1-0-0 1-0-0 6-5-0 6-5-0 12-7-8 6-2-8 18-10-0 6-2-8 25-3-0 6-5-0 26-3-0 1-0-0 1-3-011-9-41-3-010.00 12 Plate Offsets (X,Y)-- [5:0-1-4,0-1-8], [19:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.52 0.43 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.22 0.01 (loc) 20-21 20-21 10 l/defl >999 >803 n/a L/d 240 180 n/a PLATES MT20 Weight: 539 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-16,5-20: 2x4 SPF No.2, 2-21,8-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 5-22: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 5-16, 4-21, 6-10 REACTIONS.All bearings 10-7-8 except (jt=length) 21=0-3-8, 18=0-3-8. (lb) - Max Horz 21=230(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 16, 21, 10 except 17=-157(LC 3) Max Grav All reactions 250 lb or less at joint(s) 15, 14, 13, 12, 11 except 16=828(LC 1), 21=735(LC 1), 10=368(LC 1), 18=302(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-383/129, 4-5=-577/164, 6-8=-252/172, 2-21=-413/123, 8-10=-327/150 BOT CHORD 20-21=-69/520 WEBS 5-16=-522/0, 6-16=-354/214, 5-20=-108/488, 4-20=-323/211, 4-21=-346/8 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-7-8, Exterior(2R) 9-7-8 to 15-7-8, Interior(1) 15-7-8 to 23-3-0, Exterior(2E) 23-3-0 to 26-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 21, 10 except (jt=lb) 17=157. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE06 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311485 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:20 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Q8Z4tzWxz1eTI9OiopAQqpZKpb19Wav0H0clxhyrCKH Scale = 1:49.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-11-014-11-0 -1-0-0 1-0-0 7-5-8 7-5-8 14-11-0 7-5-8 15-11-0 1-0-0 1-3-07-5-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.06 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 209 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-11-0. (lb) - Max Horz 28=153(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-141(LC 6), 16=-117(LC 7), 27=-142(LC 7), 17=-125(LC 6) Max Grav All reactions 250 lb or less at joint(s) 28, 16, 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 8-22=-253/71 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-1-8, Exterior(2N) 2-1-8 to 4-5-8, Corner(3R) 4-5-8 to 10-5-8, Exterior(2N) 10-5-8 to 12-9-8, Corner(3E) 12-9-8 to 15-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=141, 16=117, 27=142, 17=125. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE07 Truss Type Monopitch Supported Gable Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311486 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:21 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-uL7S4JXZkLmKvJzuLXhfM06Vp?NTF5?9VgMJT7yrCKG Scale = 1:15.1 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x4 3x4 3x4 3x4 -0-11-0 0-11-0 2-0-0 2-0-0 1-1-02-5-08.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=2-0-0, 4=2-0-0 Max Horz 5=63(LC 7) Max Uplift 5=-6(LC 10), 4=-27(LC 7) Max Grav 5=153(LC 1), 4=67(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE07A Truss Type Monopitch Supported Gable Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311487 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-MXhqIfXBVeuBXTY4vECuvEegZPji_YFJkK5s?ayrCKF Scale = 1:15.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x4 3x4 3x4 3x4 -0-11-0 0-11-0 2-0-0 2-0-0 1-1-02-5-08.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=2-0-0, 4=2-0-0 Max Horz 5=63(LC 7) Max Uplift 5=-6(LC 10), 4=-27(LC 7) Max Grav 5=153(LC 1), 4=67(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE08 Truss Type Monopitch Supported Gable Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311488 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:23 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-qjFCV?YpGy029c6HTxj7SRBqnp38j?VSz_rPY0yrCKE Scale = 1:14.9 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x4 3x4 3x4 3x4 -1-0-0 1-0-0 1-4-0 1-4-0 1-3-02-4-510.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.21 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=1-4-0, 4=1-4-0 Max Horz 5=76(LC 9) Max Uplift 5=-9(LC 6), 4=-47(LC 7) Max Grav 5=151(LC 18), 4=43(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE09 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311489 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-IwpajLZR1G8vmmhT1fEM_fj0jCODSPubBeaz4SyrCKD Scale = 1:41.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 26 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-3-013-3-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-3-0 6-7-8 14-3-0 1-0-0 1-3-06-9-41-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.05 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-3-0. (lb) - Max Horz 24=-141(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-7-8, Corner(3R) 3-7-8 to 9-7-8, Exterior(2N) 9-7-8 to 11-3-0, Corner(3E) 11-3-0 to 14-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss GE10 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311490 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-m6Mzwha3oZGlOwGfaMlbXsGAKcjIBvAlQIKWcuyrCKC Scale: 3/8"=1' Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 8 7 6 17 18 3x4 3x4 4x6 3x8 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4-2-44-2-4 8-4-84-2-4 -1-0-0 1-0-0 4-2-4 4-2-4 8-4-8 4-2-4 9-4-8 1-0-0 1-3-04-8-141-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.21 0.12 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-105(LC 8) Max Uplift 8=-6(LC 10), 6=-6(LC 11) Max Grav 8=392(LC 1), 6=392(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-276/74, 3-4=-276/74, 2-8=-361/119, 4-6=-361/119 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 6-4-8, Exterior(2E) 6-4-8 to 9-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss J01 Truss Type Jack-Open Qty 8 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311491 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-FIwL81aiZtOc04rs84Hq34pMH04XwMEufy348LyrCKB Scale = 1:15.1 1 2 5 3 4 3x4 3x4 2-0-02-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 1-1-02-5-01-11-132-5-08.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.13 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-5-8, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 10) Max Uplift 3=-30(LC 10) Max Grav 5=153(LC 1), 3=47(LC 17), 4=36(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss J02 Truss Type JACK-OPEN Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311492 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-jUUjLNbKKBWTdEQ2ino3cHLXAQPgfpU2ucpdhnyrCKA Scale = 1:15.0 1 2 5 3 4 3x4 3x4 2-5-152-5-8 -1-4-9 1-4-9 2-5-15 2-5-15 1-2-02-4-155.98 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.18 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-4-7, 3=Mechanical, 4=Mechanical Max Horz 5=43(LC 7) Max Uplift 5=-5(LC 10), 3=-27(LC 10) Max Grav 5=211(LC 1), 3=45(LC 1), 4=44(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss J03 Truss Type JACK-OPEN STRUCTURAL Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311493 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-jUUjLNbKKBWTdEQ2ino3cHLX6QQlfpU2ucpdhnyrCKA Scale = 1:16.5 1 2 4 6 3 5 3x4 3x4 2-7-102-7-10 -1-4-9 1-4-9 2-7-10 2-7-10 1-4-92-8-55.98 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.19 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 5-6 5-6 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-8-4, 5=Mechanical, 3=Mechanical Max Horz 6=44(LC 7) Max Uplift 3=-32(LC 10) Max Grav 6=213(LC 1), 5=47(LC 3), 3=50(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss M01 Truss Type MONOPITCH Qty 4 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311494 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:28 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Bh25Yicy5UeKFO?EGVJI8VufTqjkOB2B6GYADDyrCK9 Scale = 1:17.5 1 2 3 6 5 4 7 8 9 10 4x10 3x6 5x6 2x4 6-4-06-4-0 -0-11-0 0-11-0 6-4-0 6-4-0 0-8-82-5-32-6-110-10-82-6-113.50 12 Plate Offsets (X,Y)-- [3:Edge,0-1-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.34 0.21 0.36 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.07 -0.06 0.01 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)6=0-3-8, 8=0-1-8 Max Horz 6=51(LC 7) Max Uplift 6=-72(LC 6), 8=-53(LC 6) Max Grav 6=314(LC 1), 8=226(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-270/195 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss M02 Truss Type Monopitch Qty 7 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311495 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:29 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-ftcTm2dasomBtXaRpCqXhiRukD6f7j_LLwIklgyrCK8 Scale = 1:15.1 1 2 3 5 4 3x4 3x4 3x4 3x4 2-0-02-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 1-1-02-5-02-1-80-3-82-5-08.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.12 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=62(LC 7) Max Uplift 5=-6(LC 10), 4=-27(LC 7) Max Grav 5=152(LC 1), 4=65(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss M03 Truss Type Monopitch Qty 6 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311496 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-73ArzOdCd6u2Uh9dNwLmEwz1IdSXsAhUaa1HI6yrCK7 Scale = 1:14.9 1 2 3 6 5 4 7 8 9 4x6 3x4 3x4 2x4 2x4 1-4-01-4-0 -1-0-0 1-0-0 1-4-0 1-4-0 1-3-02-4-50-10-72-4-510.00 12 Plate Offsets (X,Y)-- [3:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.19 0.06 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 8=0-1-8 Max Horz 6=38(LC 10) Max Uplift 8=-24(LC 10) Max Grav 6=147(LC 1), 8=25(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss M04 Truss Type MONOPITCH Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311497 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-73ArzOdCd6u2Uh9dNwLmEwz?ddP8s4DUaa1HI6yrCK7 Scale = 1:17.5 1 2 5 4 3 6 7 8 9 4x10 3x6 3x8 MT18HS 2x4 6-4-06-4-0 6-4-0 6-4-0 0-8-82-5-32-6-110-10-82-6-113.50 12 Plate Offsets (X,Y)-- [2:Edge,0-1-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.36 0.21 0.39 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.08 -0.06 0.01 (loc) 4-5 4-5 7 l/defl >974 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 18 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-5: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)5=0-3-8, 7=0-1-8 Max Horz 5=47(LC 7) Max Uplift 5=-43(LC 6), 7=-54(LC 6) Max Grav 5=245(LC 1), 7=231(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311498 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:31 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-bGkEBkeqOP0v6rkpxds?m7WAS1e1bdTdoEnrqYyrCK6 Scale = 1:16.6 1 2 378 3x4 3x4 3x4 6-4-06-4-0 6-4-0 6-4-0 0-8-82-6-113.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MP 0.29 0.62 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.13 0.02 (loc) 3-6 3-6 1 l/defl >999 >567 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=Mechanical Max Horz 1=60(LC 24) Max Grav 1=1018(LC 1), 3=1775(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) 3-ply truss to be connected together as follows: Top chords connected with 10d (0.131"x3") nails as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected with 10d (0.131"x3") nails as follows: 2x6 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 763 lb down at 2-0-12, and 763 lb down at 4-0-12, and 772 lb down at 6-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 3=-772(F) 7=-763(F) 8=-763(F) August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T01 Truss Type COMMON Qty 8 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311499 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:33 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Xer_cQg5v1GdL9tC22vTrYbN5rIH3RAwGYGxuRyrCK4 Scale = 1:80.7 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 3x6 6x8 3x6 3x6 3x8 3x6 2x4 3x6 2x4 3x4 8x14 MT18HS 3x4 3x6 8x14 MT18HS 3x4 3x4 9-1-09-1-0 17-11-88-10-8 26-10-08-10-8 35-11-09-1-0 -0-11-0 0-11-0 2-0-0 2-0-0 9-1-0 7-1-0 17-11-8 8-10-8 26-10-0 8-10-8 33-11-0 7-1-0 35-11-0 2-0-0 36-10-0 0-11-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [6:0-5-4,0-2-8], [12:Edge,0-3-8], [18:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.86 0.76 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.44 0.08 (loc) 15-17 15-17 12 l/defl >999 >978 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 148 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-13,4-17,3-18,9-12: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 8-15, 4-15 REACTIONS. (size)12=0-3-8, 18=0-3-8 Max Horz 18=-248(LC 8) Max Uplift 12=-3(LC 11), 18=-3(LC 10) Max Grav 12=1489(LC 1), 18=1489(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-323/0, 3-4=-1866/29, 4-6=-1382/116, 6-8=-1382/116, 8-9=-1866/29, 9-10=-323/0 BOT CHORD 17-18=-42/1439, 15-17=-42/1439, 13-15=0/1439, 12-13=0/1439 WEBS 6-15=0/827, 8-15=-559/175, 8-13=0/337, 4-15=-559/175, 4-17=0/337, 3-18=-1801/52, 9-12=-1801/53 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 1-11-0, Interior(1) 1-11-0 to 14-11-8, Exterior(2R) 14-11-8 to 20-11-8, Interior(1) 20-11-8 to 33-10-0, Exterior(2E) 33-10-0 to 36-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 18. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T02 Truss Type COMMON Qty 7 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311500 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-0rPMpmhjgKOUzJSOclQiOm8bwEfLouk4VC?VRtyrCK3 Scale = 1:88.0 12 3 4 5 6 7 8 15 14 13 12 11 10 9 16 17 3x16 MT18HS 9x22 MT18HS 3x16 MT18HS 4x6 3x6 3x8 3x6 3x6 3x6 3x6 5x12 4x6 5x12 3x6 9-1-09-1-0 17-11-88-10-8 26-10-08-10-8 35-11-09-1-0 -0-11-0 0-11-0 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [2:0-5-8,0-1-8], [4:0-6-4,0-1-8], [6:0-6-4,0-1-8], [8:0-5-8,0-1-8], [10:0-2-8,0-1-8], [14:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.66 0.64 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.26 0.06 (loc) 14-15 10-12 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 158 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-12,7-12,3-12: 2x4 SPF No.2, 2-15,8-9: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 7-12, 3-12 REACTIONS. (size)15=0-3-8, 9=Mechanical Max Horz 15=244(LC 9) Max Uplift 15=-3(LC 10) Max Grav 15=1488(LC 1), 9=1417(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1896/28, 3-5=-1379/115, 5-7=-1381/116, 7-8=-1896/28, 2-15=-1401/54, 8-9=-1329/40 BOT CHORD 14-15=-220/662, 12-14=-43/1457, 10-12=0/1463, 9-10=-65/445 WEBS 5-12=0/860, 7-12=-598/164, 7-10=0/285, 3-12=-590/163, 3-14=0/289, 2-14=0/953, 8-10=0/1023 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 14-11-8, Exterior(2R) 14-11-8 to 20-11-8, Interior(1) 20-11-8 to 32-8-4, Exterior(2E) 32-8-4 to 35-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T02A Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311501 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-yDX7ERizCyfCCccnkASATBDuj2KrGnvMyWUbVmyrCK1 Scale = 1:80.5 1 2 3 4 5 6 7 8 910 17 16 15 14 13 12 11 18 19 3x6 5x8 3x6 3x6 3x6 2x4 3x8 3x6 8x14 MT18HS 3x4 3x4 2x4 3x4 8x14 MT18HS 3x4 3x6 9-7-59-7-5 17-11-88-4-3 26-3-118-4-3 35-11-09-7-5 2-0-0 2-0-0 9-7-5 7-7-5 17-11-8 8-4-3 26-3-11 8-4-3 33-11-0 7-7-5 35-11-0 2-0-0 36-10-0 0-11-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [5:0-5-4,0-2-4], [11:Edge,0-3-8], [17:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.84 0.77 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.08 (loc) 11-12 12-14 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 147 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-12,3-16,2-17,8-11: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 7-14, 3-14 REACTIONS. (size)17=Mechanical, 11=0-5-8 Max Horz 17=-243(LC 6) Max Uplift 11=-2(LC 11) Max Grav 17=1424(LC 1), 11=1490(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-365/0, 2-3=-1857/33, 3-5=-1372/120, 5-7=-1372/120, 7-8=-1855/33, 8-9=-351/0 BOT CHORD 16-17=-35/1428, 14-16=-35/1428, 12-14=0/1424, 11-12=0/1424 WEBS 7-14=-566/174, 5-14=-16/862, 7-12=0/345, 3-14=-571/174, 3-16=0/346, 2-17=-1775/96, 8-11=-1805/80 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-11-8, Exterior(2R) 14-11-8 to 20-11-8, Interior(1) 20-11-8 to 33-10-0, Exterior(2E) 33-10-0 to 36-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T05 Truss Type Common Qty 11 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311502 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-QQ5VRnjbzFn2qmBzHuzP0Om4xSf8?EGWBAE91CyrCK0 Scale = 1:79.9 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x6 5x8 3x6 3x6 3x8 3x6 2x4 3x6 2x4 3x4 8x14 MT18HS 3x4 3x6 8x14 MT18HS 3x4 3x4 9-7-59-7-5 17-11-88-4-3 26-3-118-4-3 35-11-09-7-5 2-0-0 2-0-0 9-7-5 7-7-5 17-11-8 8-4-3 26-3-11 8-4-3 33-11-0 7-7-5 35-11-0 2-0-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [5:0-5-4,0-2-4], [10:Edge,0-3-8], [16:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.81 0.76 0.43 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.08 (loc) 15-16 11-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 146 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-11,3-15,2-16,8-10: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 7-13, 3-13 REACTIONS. (size)10=Mechanical, 16=Mechanical Max Horz 16=-235(LC 6) Max Grav 10=1425(LC 1), 16=1425(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-365/0, 2-3=-1859/33, 3-5=-1374/120, 5-7=-1374/120, 7-8=-1859/33, 8-9=-365/0 BOT CHORD 15-16=-44/1429, 13-15=-44/1429, 11-13=0/1429, 10-11=0/1429 WEBS 5-13=-16/865, 7-13=-571/174, 7-11=0/346, 3-13=-571/174, 3-15=0/346, 2-16=-1777/95, 8-10=-1777/96 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-11-8, Exterior(2R) 14-11-8 to 20-11-8, Interior(1) 20-11-8 to 32-9-4, Exterior(2E) 32-9-4 to 35-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T06 Truss Type COMMON Qty 4 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311503 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:38 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-ucftf7kDkZvvSwm9rbUeYbJHvs0NkjGfPqziaeyrCK? Scale = 1:58.7 1 2 3 4 5 6 7 8 9 13 12 11 10 14 15 4x6 3x4 3x8 2x4 2x4 3x4 6x8 3x4 6x8 3x4 3x4 9-11-89-11-8 19-11-09-11-8 -1-0-0 1-0-0 3-0-0 3-0-0 5-1-0 2-1-0 9-11-8 4-10-8 14-10-0 4-10-8 16-11-0 2-1-0 19-11-0 3-0-0 20-11-0 1-0-0 1-3-09-6-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.66 0.70 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.33 0.02 (loc) 11-13 11-13 10 l/defl >999 >708 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-13,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)10=0-3-8, 13=0-3-8 Max Horz 13=-191(LC 8) Max Grav 10=854(LC 1), 13=854(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-296/27, 3-4=-759/59, 4-5=-667/89, 5-6=-667/89, 6-7=-759/59, 7-8=-296/27, 2-13=-281/63, 8-10=-281/63 BOT CHORD 11-13=-34/591, 10-11=0/548 WEBS 5-11=-25/479, 3-13=-650/40, 7-10=-650/40 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-8, Exterior(2R) 6-11-8 to 12-11-8, Interior(1) 12-11-8 to 17-11-0, Exterior(2E) 17-11-0 to 20-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T07 Truss Type COMMON Qty 4 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311504 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:40 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-q?md4plUGA9dhEwYz0X6e0OdPfiqCdkyt8SpdXyrCJz Scale = 1:58.7 1 2 3 4 5 6 7 8 12 11 10 9 13 14 4x6 3x4 3x4 3x8 2x4 2x4 3x4 6x8 6x8 3x4 3x4 9-11-89-11-8 19-11-09-11-8 -1-0-0 1-0-0 3-0-0 3-0-0 5-1-0 2-1-0 9-11-8 4-10-8 14-10-0 4-10-8 16-11-0 2-1-0 19-11-0 3-0-0 1-3-09-6-91-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.66 0.70 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.33 0.02 (loc) 9-10 9-10 9 l/defl >999 >708 n/a L/d 240 180 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-12,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)9=0-3-8, 12=0-3-8 Max Horz 12=185(LC 7) Max Grav 9=783(LC 1), 12=856(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-296/28, 3-4=-761/59, 4-5=-670/89, 5-6=-671/89, 6-7=-763/59, 7-8=-298/5, 2-12=-280/63 BOT CHORD 10-12=-45/584, 9-10=0/555 WEBS 5-10=-25/481, 3-12=-653/40, 7-9=-637/52 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-8, Exterior(2R) 6-11-8 to 12-11-8, Interior(1) 12-11-8 to 16-9-4, Exterior(2E) 16-9-4 to 19-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T08 Truss Type COMMON Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311505 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-IBK0H9m61UHUJNVkWj2LAExnD33dx5766nCM9zyrCJy Scale = 1:58.7 1 2 3 4 5 6 10 9 8 7 11 12 13 14 4x6 6x6 3x6 2x4 3x4 3x6 3x8 6x8 3x4 9-11-89-11-8 17-0-07-0-8 17-3-90-3-9 -1-0-0 1-0-0 3-0-0 3-0-0 5-1-0 2-1-0 9-11-8 4-10-8 17-0-0 7-0-8 1-3-09-6-90-3-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.72 0.60 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.40 0.01 (loc) 8-10 8-10 7 l/defl >999 >503 n/a L/d 240 180 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)7=0-3-8, 10=0-3-8 Max Horz 10=208(LC 7) Max Grav 7=666(LC 1), 10=739(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-335/20, 3-4=-599/67, 4-5=-506/97, 5-6=-552/81, 2-10=-303/60, 6-7=-612/32 BOT CHORD 8-10=-66/483 WEBS 5-8=-9/304, 6-8=0/337, 3-10=-463/35 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-8, Exterior(2R) 6-11-8 to 12-11-8, Interior(1) 12-11-8 to 13-10-4, Exterior(2E) 13-10-4 to 16-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T09 Truss Type Common Qty 2 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311506 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-nNuOVVnkooPLwX3w4RZajRT0nTTugUYFKRxwiPyrCJx Scale = 1:71.7 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 18 19 3x4 4x6 3x4 3x4 3x8 3x6 3x6 3x4 4x8 3x4 4x8 3x4 3x4 2x4 2x4 6-5-06-5-0 12-7-86-2-8 18-10-06-2-8 25-3-06-5-0 -1-0-0 1-0-0 3-0-0 3-0-0 6-5-0 3-5-0 12-7-8 6-2-8 18-10-0 6-2-8 22-3-0 3-5-0 25-3-0 3-0-0 26-3-0 1-0-0 1-3-011-9-41-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.48 0.34 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.13 0.03 (loc) 14-16 13-14 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-14: 2x4 SPF No.2, 2-17,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 7-14, 5-14 REACTIONS. (size)12=0-3-8, 17=0-3-8 Max Horz 17=230(LC 9) Max Grav 12=1067(LC 1), 17=1067(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-1070/38, 5-6=-842/122, 6-7=-842/122, 7-9=-1070/38 BOT CHORD 16-17=-30/808, 14-16=-30/808, 13-14=0/760, 12-13=0/760 WEBS 6-14=-55/548, 7-14=-324/156, 5-14=-324/156, 3-17=-1006/0, 9-12=-1006/0 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-7-8, Exterior(2R) 9-7-8 to 15-7-8, Interior(1) 15-7-8 to 23-3-0, Exterior(2E) 23-3-0 to 26-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T10 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311507 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:43 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-FZSmiroMZ5XCYhe7e84pFf05ttohP1TOZ5hTEsyrCJw Scale = 1:46.3 1 2 3 4 5 8 7 6 9 10 3x4 3x4 3x8 4x6 8x8 8x8 7-5-87-5-8 14-11-07-5-8 -1-0-0 1-0-0 7-5-8 7-5-8 14-11-0 7-5-8 15-11-0 1-0-0 1-3-07-5-91-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.84 0.37 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.01 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=153(LC 9) Max Uplift 8=-1(LC 10), 6=-1(LC 11) Max Grav 8=654(LC 1), 6=654(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-581/74, 3-4=-581/74, 2-8=-585/89, 4-6=-585/89 BOT CHORD 7-8=-162/387, 6-7=-101/282 WEBS 3-7=0/297 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-5-8, Exterior(2R) 4-5-8 to 10-5-8, Interior(1) 10-5-8 to 12-11-0, Exterior(2E) 12-11-0 to 15-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 2 = 8%, joint 4 = 8% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T11 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311508 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-jm08vBo_KPf3ArDJBsb2osZOsGAh8VjYolQ1mIyrCJv Scale = 1:36.9 1 2 3 4 7 6 5 8 9 3x4 3x4 3x8 4x6 5x8 5x8 5-5-85-5-8 10-11-05-5-8 5-5-8 5-5-8 10-11-0 5-5-8 11-11-0 1-0-0 1-3-05-9-91-3-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-10], [3:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.38 0.19 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7,3-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=-118(LC 6) Max Uplift 5=-3(LC 11) Max Grav 7=421(LC 1), 5=497(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-402/85, 2-3=-407/87, 1-7=-371/76, 3-5=-447/113 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 8-5-8, Interior(1) 8-5-8 to 8-11-0, Exterior(2E) 8-11-0 to 11-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T12 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311509 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-ByaW7Wpc5jnwn?oVlZ6HL45RVgOzts6h0PAaIkyrCJu Scale = 1:84.6 1 2 3 4 5 6 78 15 14 13 12 11 10 9 16 17 9x22 MT18HS 3x6 3x8 5x12 2x4 5x12 2x4 3x4 8x14 MT18HS 3x4 3x6 8x14 MT18HS 3x6 3x6 9-7-59-7-5 17-11-88-4-3 26-3-118-4-3 35-11-09-7-5 2-0-0 2-0-0 9-7-5 7-7-5 17-11-8 8-4-3 26-3-11 8-4-3 33-11-0 7-7-5 35-11-0 2-0-0 36-10-0 0-11-0 1-1-013-0-81-1-08.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-3-0], [5:0-6-0,0-3-0], [9:Edge,0-3-8], [15:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.83 0.77 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.37 0.08 (loc) 9-10 10-12 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 147 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 5-10,3-14,2-15,6-9: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. WEBS 1 Row at midpt 5-12, 3-12 REACTIONS. (size)9=0-5-8, 15=0-3-8 Max Horz 15=-243(LC 8) Max Uplift 9=-2(LC 11) Max Grav 9=1490(LC 1), 15=1424(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-364/0, 2-3=-1855/33, 3-4=-1370/121, 4-5=-1369/121, 5-6=-1853/32, 6-7=-351/0 BOT CHORD 14-15=-33/1425, 12-14=-35/1422, 10-12=0/1418, 9-10=0/1421 WEBS 4-12=-20/873, 5-12=-566/176, 5-10=0/346, 3-12=-570/176, 3-14=0/346, 2-15=-1781/100, 6-9=-1810/85 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-11-8, Exterior(2R) 14-11-8 to 20-11-8, Interior(1) 20-11-8 to 33-10-0, Exterior(2E) 33-10-0 to 36-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T13 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311510 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-f88vKsqFr0vnP9NiJHdWtHem14uDcPNrF3v7rByrCJt Scale = 1:31.7 1 2 3 4 5 8 7 6 9 10 3x4 3x4 4x6 3x8 3x6 3x6 4-2-44-2-4 8-4-84-2-4 -1-0-0 1-0-0 4-2-4 4-2-4 8-4-8 4-2-4 9-4-8 1-0-0 1-3-04-8-141-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.21 0.12 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-105(LC 8) Max Uplift 8=-6(LC 10), 6=-6(LC 11) Max Grav 8=392(LC 1), 6=392(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-276/74, 3-4=-276/74, 2-8=-361/119, 4-6=-361/119 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 6-4-8, Exterior(2E) 6-4-8 to 9-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T14 Truss Type Common Qty 2 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311511 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-7LiHYCrtcK1e1Jyut_9lQVAwnUEcLsf_UjfhNdyrCJs Scale: 3/8"=1' 1 2 3 4 7 6 5 8 9 3x4 3x4 4x6 3x6 3x8 3x6 3-9-123-9-12 8-0-04-2-4 3-9-12 3-9-12 8-0-0 4-2-4 9-0-0 1-0-0 1-6-124-8-141-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.21 0.11 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7,3-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=-102(LC 6) Max Uplift 5=-5(LC 11) Max Grav 7=303(LC 1), 5=382(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-264/68, 1-7=-276/74, 3-5=-350/117 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 6-0-0, Exterior(2E) 6-0-0 to 9-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T15 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311512 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:48 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-bXFflYrVNe9VfSX4Qhg_yij5eua84J_8jNOEv3yrCJr Scale: 3/8"=1' 1 2 3 6 5 4 7 8 3x4 3x4 4x6 3x6 3x8 3x6 3-9-123-9-12 7-4-03-6-4 3-9-12 3-9-12 7-4-0 3-6-4 1-6-124-8-141-9-1110.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.20 0.09 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)6=0-3-8, 4=Mechanical Max Horz 6=92(LC 7) Max Grav 6=282(LC 1), 4=282(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-253/69, 3-4=-256/69 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 4-2-4, Exterior(2E) 4-2-4 to 7-2-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T16 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311513 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-3jp1zus78xHMGc6H_PBDVwGHtHwVpmIHx18oRVyrCJq Scale = 1:30.8 1 2 3 6 5 4 7 8 4x6 3x4 3x6 3x8 3x4 3x6 -0-3-80-3-8 3-6-43-6-4 7-0-83-6-4 7-4-00-3-8 3-6-4 3-6-4 7-0-8 3-6-4 0-3-84-8-140-3-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.17 0.09 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)6=0-3-8, 4=0-3-8 Max Horz 6=92(LC 7) Max Grav 6=270(LC 1), 4=270(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 3-10-12, Exterior(2E) 3-10-12 to 6-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 5) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T17 Truss Type ROOF SPECIAL Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311514 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-3jp1zus78xHMGc6H_PBDVwGHLHxGpmxHx18oRVyrCJq Scale = 1:15.1 1 2 3 5 4 3x4 3x4 3x4 3x4 -0-11-15 0-11-15 2-2-0 2-2-0 1-1-02-5-02-1-80-3-82-5-07.39 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.14 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-10, 4=0-1-8 Max Horz 5=62(LC 7) Max Uplift 5=-9(LC 10), 4=-24(LC 7) Max Grav 5=164(LC 1), 4=70(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T18 Truss Type ROOF SPECIAL Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311515 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-YwNPAEtlvFPCumhTY6iS27oS5hGVYDAQAhtL_yyrCJp Scale = 1:15.1 1 2 3 5 4 3x4 3x4 3x4 3x4 -0-11-15 0-11-15 2-2-0 2-2-0 1-1-02-5-02-1-80-3-82-5-07.39 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.14 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-10, 4=0-1-8 Max Horz 5=62(LC 7) Max Uplift 5=-9(LC 10), 4=-24(LC 7) Max Grav 5=164(LC 1), 4=70(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss T19 Truss Type Common Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311516 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-06xoNauNgZY3WwFf6qDhaLLTQ5YrHf3aPLduWOyrCJo Scale = 1:43.8 1 2 3 4 7 6 5 8 9 4x6 4x6 2x4 4x6 5x8 5x8 6-11-86-11-8 13-11-06-11-8 6-11-8 6-11-8 13-11-0 6-11-8 14-11-0 1-0-0 1-3-07-0-91-3-010.00 12 Plate Offsets (X,Y)-- [3:0-4-9,0-0-0], [5:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.80 0.29 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.01 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)7=0-5-8, 5=0-3-8 Max Horz 7=-140(LC 6) Max Uplift 5=-1(LC 11) Max Grav 7=542(LC 1), 5=617(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-531/82, 2-3=-537/82, 1-7=-465/78, 3-5=-542/111 BOT CHORD 6-7=0/321, 5-6=0/321 WEBS 2-6=0/277 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 3-11-8, Exterior(2R) 3-11-8 to 9-11-8, Interior(1) 9-11-8 to 11-11-0, Exterior(2E) 11-11-0 to 14-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 1 = 12%, joint 3 = 12% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG01 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311517 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-yV3YoGveCAonlEP2DFG9fmQo1vD7lWStsf6?bHyrCJm Scale = 1:62.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 13 12 11 10424344 4x6 4x6 3x8 2x4 2x4 3x4 5x8 3x4 5x8 3x4 3x12 2x4 2x4 2x4 3x4 3x12 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-11-89-11-8 19-11-09-11-8 -1-0-0 1-0-0 2-0-0 2-0-0 5-1-8 3-1-8 9-11-8 4-10-0 14-9-8 4-10-0 17-11-0 3-1-8 19-11-0 2-0-0 20-11-0 1-0-0 1-3-09-6-91-3-010.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-3-13], [7:0-6-0,0-3-13], [10:Edge,0-1-12], [13:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.86 0.36 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.10 0.01 (loc) 11-13 11-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 360 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-11: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 13=0-3-8 Max Horz 13=-188(LC 6) Max Uplift 10=-2(LC 9), 13=-9(LC 8) Max Grav 10=853(LC 1), 13=852(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-361/0, 3-4=-795/55, 4-5=-663/88, 5-6=-663/83, 6-7=-795/49, 7-8=-361/0, 2-13=-287/1, 8-10=-276/9 BOT CHORD 11-13=-33/604, 10-11=0/558 WEBS 5-11=-25/479, 3-13=-586/117, 7-10=-584/82 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 13. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 29 lb down and 50 lb up at 1-8-0, and 49 lb down and 49 lb up at 1-11-4 on top chord, and 7 lb down and 1 lb up at 1-8-0, 12 lb down and 0 lb up at 1-11-4, 12 lb down and 0 lb up at 3-11-4, and 12 lb down and 0 lb up at 5-11-4, and 12 lb down and 0 lb up at 7-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG01 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311517 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:53 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-yV3YoGveCAonlEP2DFG9fmQo1vD7lWStsf6?bHyrCJm LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-5=-60, 5-8=-60, 8-9=-60, 10-13=-20 Concentrated Loads (lb) Vert: 12=0(B) 42=1(B) 43=0(B) 44=0(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311518 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-utAIDxxukn2V_XZQLgIdlBWC2isFDHV9Kzb6f9yrCJk Scale = 1:71.7 1 2 3 4 5 11 10 9 8 7 61213141516171819202122 4x8 5x10 MT18HS 5x10 MT18HS 8x8 5x8 8x8 5x8 8x8 4x10 5x10 MT18HS 4x10 6-5-86-5-8 12-7-86-2-0 18-9-86-2-0 25-3-06-5-8 3-0-0 3-0-0 6-5-8 3-5-8 12-7-8 6-2-0 18-9-8 6-2-0 22-3-0 3-5-8 25-3-0 3-0-0 1-3-011-9-41-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-3-0], [4:0-3-0,0-3-0], [6:Edge,0-2-8], [7:0-3-8,0-4-8], [8:0-4-0,0-4-8], [10:0-3-8,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.64 0.51 0.83 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.22 0.03 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 471 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-8,4-8,2-8: 2x4 SPF No.2, 1-11,5-6: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 6=0-3-8 Max Horz 11=212(LC 5) Max Grav 11=9580(LC 1), 6=9251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-9875/0, 2-3=-7220/0, 3-4=-7220/0, 4-5=-9842/0, 1-11=-7227/0, 5-6=-7217/0 BOT CHORD 10-11=0/3067, 8-10=0/7478, 7-8=0/7452, 6-7=0/2982 WEBS 3-8=0/8685, 4-8=-2844/0, 4-7=0/3379, 2-8=-2881/0, 2-10=0/3425, 1-10=0/4479, 5-7=0/4539 NOTES-(9-10) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1404 lb down at 1-4-12, 1405 lb down at 3-4-12, 1405 lb down at 5-4-12, 1405 lb down at 7-4-12, 1405 lb down at 9-4-12, 1405 lb down at 11-4-12, 1405 lb down at 13-4-12, 1405 lb down at 15-4-12, 1405 lb down at 17-4-12, 1405 lb down at 19-4-12, and 1405 lb down at 21-4-12, and 1405 lb down at 23-4-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type COMMON GIRDER Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311518 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:56 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-M4khRHyWV5AMch8duNpsHO2No6BUyklJYdLfBbyrCJj LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-11=-20 Concentrated Loads (lb) Vert: 9=-1405(B) 12=-1404(B) 13=-1405(B) 14=-1405(B) 15=-1405(B) 16=-1405(B) 17=-1405(B) 18=-1405(B) 19=-1405(B) 20=-1405(B) 21=-1405(B) 22=-1405(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG03 Truss Type COMMON GIRDER Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311519 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:57 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-qGI3edy8GPIDErjpS4K5qcbXmWSnhDnSnH4Dk2yrCJi Scale: 3/16"=1' 1 2 3 4 5 12 11 9 8 7 61314151016171819 3x12 4x6 3x12 8x14 MT18HS 5x10 MT18HS4x8 4x8 8x8 4x8 8x8 8x14 MT18HS 5-7-105-7-10 8-2-72-6-13 10-11-122-9-5 16-3-145-4-2 21-11-85-7-10 5-7-10 5-7-10 10-11-12 5-4-2 16-3-14 5-4-2 21-11-8 5-7-10 1-3-010-4-131-3-010.00 12 Plate Offsets (X,Y)-- [7:0-3-8,0-4-12], [11:0-3-8,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.89 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.17 0.02 (loc) 7-9 7-9 6 l/defl >999 >952 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 362 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-9: 2x4 SPF No.2, 1-12,5-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)12=0-5-8, 6=0-3-8, 10=0-3-8 Max Horz 12=-187(LC 6) Max Grav 12=5553(LC 1), 6=6638(LC 1), 10=3579(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5262/0, 2-3=-4157/0, 3-4=-4155/0, 4-5=-6844/0, 1-12=-3786/0, 5-6=-5105/0 BOT CHORD 11-12=0/2325, 10-11=0/3950, 9-10=0/3950, 7-9=0/5161, 6-7=0/1945 WEBS 3-9=0/4838, 4-9=-2944/0, 4-7=0/3561, 2-9=-1231/0, 2-11=0/1330, 1-11=0/1654, 5-7=0/3273 NOTES-(9-10) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1405 lb down at 2-1-4, 1405 lb down at 4-1-4, 1405 lb down at 6-1-4, 1405 lb down at 8-1-4, 1405 lb down at 10-1-4, 1405 lb down at 12-1-4, 1405 lb down at 14-1-4, 1405 lb down at 16-1-4, and 1405 lb down at 18-1-4, and 1405 lb down at 20-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG03 Truss Type COMMON GIRDER Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311519 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:22:58 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-JSsRrzzm1iQ4r?I?0orKMp8iWwo0Qg1c0xqmGUyrCJh LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-12=-20 Concentrated Loads (lb) Vert: 8=-1405(F) 7=-1405(F) 10=-1405(F) 13=-1405(F) 14=-1405(F) 15=-1405(F) 16=-1405(F) 17=-1405(F) 18=-1405(F) 19=-1405(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG04 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311520 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:00 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Fr_BGf?1YKgo5IRO7DuoRED7zjd6ugevTFJtKNyrCJf Scale = 1:73.4 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 12 11 10 9 48 49 50 51 52 53 7x16 MT18HS 3x12 4x6 3x8 3x6 3x6 2x4 3x6 4x6 3x12 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-4-38-4-3 16-3-147-11-11 21-11-85-7-10 -1-0-0 1-0-0 5-7-10 5-7-10 10-11-12 5-4-2 16-3-14 5-4-2 21-11-8 5-7-10 22-11-8 1-0-0 1-3-010-4-131-3-010.00 12 Plate Offsets (X,Y)-- [4:0-6-0,0-7-12], [10:0-1-1,0-1-8], [11:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.37 0.28 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 0.01 (loc) 10-12 10-12 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 437 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-10,5-10: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 SLIDER Right 2x8 SP 2400F 2.0E 2-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 5-10 REACTIONS. (size)10=0-3-8, 12=0-5-8, 7=0-3-8 Max Horz 12=-197(LC 6) Max Uplift 12=-69(LC 9), 7=-32(LC 9) Max Grav 10=872(LC 1), 12=395(LC 21), 7=606(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-293/127, 5-7=-454/67, 2-12=-342/134 BOT CHORD 9-10=0/355, 7-9=0/355 WEBS 3-10=-292/175, 4-10=-275/0, 5-10=-370/121, 5-9=0/261 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are MT20 plates unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 31 lb down and 57 lb up at 1-8-0, and 49 lb down and 49 lb up at 1-11-12 on top chord, and 8 lb down and 1 lb up at 1-8-0, 12 lb down and 0 lb up at 1-11-12, 12 lb down and 0 lb up at 3-11-12, and 12 lb down and 0 lb up at 5-11-12, and 12 lb down and 0 lb up at 7-11-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG04 Truss Type GABLE Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311520 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:00 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Fr_BGf?1YKgo5IRO7DuoRED7zjd6ugevTFJtKNyrCJf LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-8=-60, 12-44=-20 Concentrated Loads (lb) Vert: 11=0(B) 50=1(B) 51=0(B) 52=0(B) 53=0(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG05 Truss Type Common Girder Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311521 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-j1YaU??fJdofiS0ahwP1_SmBc7xyd0A2iv2QtpyrCJe Scale = 1:41.6 1 2 3 4 5 10 9 8 7 61112131415 12x18 MT18HS 4x6 12x18 MT18HS 8x8 3x6 4x6 3x6 4x6 3-5-83-5-8 6-7-83-2-0 9-9-83-2-0 13-3-03-5-8 3-5-8 3-5-8 6-7-8 3-2-0 9-9-8 3-2-0 13-3-0 3-5-8 1-3-06-9-41-3-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-10-6], [5:Edge,0-10-6], [8:0-4-0,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MR 0.82 0.43 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 217 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 6=0-5-8 Max Horz 10=-122(LC 4) Max Grav 10=5236(LC 1), 6=4187(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4612/0, 2-3=-3483/0, 3-4=-3484/0, 4-5=-4411/0, 1-10=-3831/0, 5-6=-3706/0 BOT CHORD 9-10=0/759, 8-9=0/3457, 7-8=0/3305, 6-7=0/583 WEBS 3-8=0/4126, 4-8=-996/0, 4-7=0/1246, 2-8=-1229/0, 2-9=0/1558, 1-9=0/2807, 5-7=0/2833 NOTES-(9-10) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1400 lb down at 0-10-4, 1397 lb down at 2-10-4, 1397 lb down at 4-10-4, 1397 lb down at 6-10-4, and 1397 lb down at 8-10-4, and 1397 lb down at 10-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss TG05 Truss Type Common Girder Qty 1 Ply 3 19 Estates at Towne Meadow Job Reference (optional) I47311521 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:01 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-j1YaU??fJdofiS0ahwP1_SmBc7xyd0A2iv2QtpyrCJe LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 8=-1397(B) 11=-1400(B) 12=-1397(B) 13=-1397(B) 14=-1397(B) 15=-1397(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V01 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311522 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-BD6yhK0H4xwVKcbmFewGXfIWeXMUMbpBxZo_PFyrCJd Scale = 1:61.6 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-6-422-6-4 22-6-90-0-5 11-3-4 11-3-4 22-6-9 11-3-4 0-0-49-4-120-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.09 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 22-5-15. (lb) - Max Horz 1=-162(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 13, 8 except 12=-105(LC 10), 9=-105(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 10 except 12=354(LC 17), 13=311(LC 17), 9=354(LC 18), 8=311(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-274/154, 5-9=-273/154 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-3-4, Interior(1) 3-3-4 to 8-3-4, Exterior(2R) 8-3-4 to 14-3-4, Interior(1) 14-3-4 to 19-1-11, Exterior(2E) 19-1-11 to 22-1-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 13, 8 except (jt=lb) 12=105, 9=105. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V02 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311523 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:03 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-fQfKvg1vrF2MymAzpLRV3tre0xde528L9DXXxhyrCJc Scale = 1:52.1 1 2 3 4 5 9 8 7 6 10 11 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-50-0-5 19-4-219-3-13 9-8-1 9-8-1 19-4-2 9-8-1 0-0-48-0-120-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.32 0.35 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-3-9. (lb) - Max Horz 1=139(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 9=-138(LC 10), 6=-137(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=479(LC 17), 6=479(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-362/196, 4-6=-362/196 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 6-8-1, Exterior(2R) 6-8-1 to 12-8-1, Interior(1) 12-8-1 to 15-11-14, Exterior(2E) 15-11-14 to 18-11-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb uplift at joint 9 and 137 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V03 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311524 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:04 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-7cDi602XcYADZwl9M3ykc4OruK0RqWMUOtH4T8yrCJb Scale = 1:42.5 1 2 3 4 5 9 8 7 6 10 11 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-50-0-5 16-1-1216-1-7 8-0-14 8-0-14 16-1-12 8-0-14 0-0-46-8-120-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.18 0.19 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-1-2. (lb) - Max Horz 1=115(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-112(LC 10), 6=-111(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=377(LC 17), 6=377(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-289/159, 4-6=-288/159 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 5-0-14, Exterior(2R) 5-0-14 to 11-0-14, Interior(1) 11-0-14 to 12-9-8, Exterior(2E) 12-9-8 to 15-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=112, 6=111. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V04 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311525 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:05 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-bon4JM39NsI4B4KLwmTz8Iw_gkN3Z_HedW0e0ayrCJa Scale = 1:34.5 1 2 3 4 5 8 7 6 9 10 3x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 12-11-112-11-1 12-11-50-0-5 6-5-11 6-5-11 12-11-5 6-5-11 0-0-45-4-120-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.10 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-10-12. (lb) - Max Horz 1=-92(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=308(LC 17), 6=308(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 9-6-12, Exterior(2E) 9-6-12 to 12-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V05 Truss Type VALLEY Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311526 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:06 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-4?LSXi3n8ARxpDvYUT_ChVT538feIRsnsAmBY0yrCJZ Scale = 1:26.2 1 2 3 4 5 6 3x4 5x6 3x4 2x4 9-8-109-8-10 9-8-150-0-5 4-10-8 4-10-8 9-8-15 4-10-7 0-0-44-0-120-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.33 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-8-5, 3=9-8-5, 4=9-8-5 Max Horz 1=-68(LC 6) Max Uplift 1=-8(LC 11), 3=-17(LC 11) Max Grav 1=192(LC 1), 3=192(LC 1), 4=349(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-7 to 3-3-7, Exterior(2R) 3-3-7 to 6-5-8, Exterior(2E) 6-5-8 to 9-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V06 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311527 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:07 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-YBvrk24QvTZoQNUk2BWREj?KQYu11vOx4qVk4TyrCJY Scale = 1:19.2 1 2 3 3x4 3x4 3x4 0-0-50-0-5 6-6-96-6-4 3-3-4 3-3-4 6-6-9 3-3-4 0-0-42-8-120-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [2:0-2-0,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.29 0.77 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-5-15, 3=6-5-15 Max Horz 1=-45(LC 6) Max Grav 1=239(LC 1), 3=239(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V07 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311528 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:08 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-0NTDyO52gnhf2X3wbu1gmwYU9xNomJK4JUFIcvyrCJX Scale = 1:53.6 1 2 3 4 5 9 8 7 6 10 11 3x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 0-0-50-0-5 20-5-720-5-2 10-2-12 10-2-12 20-5-7 10-2-12 0-0-48-6-40-0-410.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.22 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 66 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.All bearings 20-4-13. (lb) - Max Horz 1=-147(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 9=-147(LC 10), 6=-147(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=517(LC 17), 6=517(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-378/207, 4-6=-378/207 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 7-2-12, Exterior(2R) 7-2-12 to 13-2-12, Interior(1) 13-2-12 to 17-0-10, Exterior(2E) 17-0-10 to 20-0-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 147 lb uplift at joint 9 and 147 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V08 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311529 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Ua1b9k6gR5pWghe79cYvJ85hxLizVnIDY8_r9LyrCJW Scale = 1:45.3 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 17-2-1217-2-12 17-3-10-0-5 8-7-8 8-7-8 17-3-1 8-7-8 0-0-47-2-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.23 0.23 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-2-7. (lb) - Max Horz 1=-123(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 9=-120(LC 10), 6=-120(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=410(LC 17), 6=409(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-312/171, 4-6=-312/171 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Interior(1) 3-4-4 to 5-7-8, Exterior(2R) 5-7-8 to 11-7-8, Interior(1) 11-7-8 to 13-10-13, Exterior(2E) 13-10-13 to 16-10-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 120 lb uplift at joint 9 and 120 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V09 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311530 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:10 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-ymazN46ICOxNHrCJjJ38rLdrOl4IEEENmokPhoyrCJV Scale = 1:37.2 1 2 3 4 5 8 7 6 9 10 3x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-50-0-5 14-0-1014-0-5 7-0-5 7-0-5 14-0-10 7-0-5 0-0-45-10-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.09 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-0-1. (lb) - Max Horz 1=-100(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-101(LC 10), 6=-101(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=326(LC 17), 6=326(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Interior(1) 3-4-9 to 4-0-5, Exterior(2R) 4-0-5 to 10-0-5, Interior(1) 10-0-5 to 10-8-1, Exterior(2E) 10-8-1 to 13-8-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=101, 6=101. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V10 Truss Type VALLEY Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311531 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Qy8LaP7wzi3Ev?nVH1aNOZAxd9ObzhoW?STyDEyrCJU Scale = 1:29.0 1 2 3 4 5 6 3x6 6x6 3x6 2x4 0-0-50-0-5 10-10-410-9-15 5-5-2 5-5-2 10-10-4 5-5-2 0-0-44-6-40-0-410.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.60 0.22 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-9-10, 3=10-9-10, 4=10-9-10 Max Horz 1=-76(LC 6) Max Uplift 1=-7(LC 10), 3=-15(LC 11) Max Grav 1=211(LC 1), 3=211(LC 1), 4=385(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 7-5-11, Exterior(2E) 7-5-11 to 10-5-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 5) Non Standard bearing condition. Review required. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V11 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311532 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-Qy8LaP7wzi3Ev?nVH1aNOZA_j9K3ziNW?STyDEyrCJU Scale = 1:21.6 1 2 3 4 5 3x4 3x4 3x4 0-0-50-0-5 7-7-137-7-9 3-9-15 3-9-15 7-7-13 3-9-15 0-0-43-2-40-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.40 0.51 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-7-4, 3=7-7-4 Max Horz 1=52(LC 7) Max Grav 1=276(LC 1), 3=276(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 4-3-4, Exterior(2E) 4-3-4 to 7-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V12 Truss Type VALLEY Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311533 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:12 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-u9ikol8Yk0B5X8Mhqk5cxmj7NZkAi8GgE6DVmgyrCJT Scale = 1:27.8 1 2 3 4 5 6 3x4 6x6 3x4 2x4 10-3-1310-3-13 10-4-20-0-5 5-2-1 5-2-1 10-4-2 5-2-1 0-0-44-3-120-0-410.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.20 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-3-9, 3=10-3-9, 4=10-3-9 Max Horz 1=-72(LC 6) Max Uplift 1=-7(LC 10), 3=-14(LC 11) Max Grav 1=201(LC 1), 3=201(LC 1), 4=365(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 6-11-9, Exterior(2E) 6-11-9 to 9-11-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V13 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311534 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-MLG6?59AVJJy8IxuOScrT_FLuy5oRcKpTmy3I6yrCJS Scale = 1:20.6 1 2 3 43x4 3x4 3x4 2x4 0-0-50-0-5 7-1-127-1-7 3-6-14 3-6-14 7-1-12 3-6-14 0-0-42-11-120-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.36 0.17 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-1-2, 3=7-1-2, 4=7-1-2 Max Horz 1=-49(LC 6) Max Uplift 1=-12(LC 11), 3=-18(LC 11) Max Grav 1=149(LC 1), 3=149(LC 1), 4=227(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V14 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311535 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:14 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:BFUQedjObqdrtP0hatD81oyrF2D-rXqUCRApFdRomSW4y9840BoauMT?A3wyhQicqZyrCJR Scale = 1:11.0 1 2 3 4 3x4 3x4 3x4 2x4 0-0-50-0-5 3-11-53-11-1 1-11-11 1-11-11 3-11-5 1-11-11 0-0-41-7-120-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-5 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-10-12, 3=3-10-12, 4=3-10-12 Max Horz 1=25(LC 9) Max Uplift 1=-6(LC 11), 3=-9(LC 11) Max Grav 1=77(LC 1), 3=77(LC 1), 4=116(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V15 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311536 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-JjOsQnAR0wZfOc5GWsfJYPLlAmo?vW76w4RAM?yrCJQ Scale: 1"=1' 1 2 3 4 3x4 3x4 3x4 2x4 4-5-24-5-2 4-5-70-0-5 2-2-11 2-2-11 4-5-7 2-2-11 0-0-41-10-40-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-7 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-4-13, 3=4-4-13, 4=4-4-13 Max Horz 1=29(LC 7) Max Uplift 1=-7(LC 11), 3=-10(LC 11) Max Grav 1=88(LC 1), 3=88(LC 1), 4=134(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 19_ESTATES_AT_TOWNE_~W Truss V16 Truss Type Valley Qty 1 Ply 1 19 Estates at Towne Meadow Job Reference (optional) I47311537 8.430 s Jun 2 2021 MiTek Industries, Inc. Wed Aug 4 14:23:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:TBXJu2RzLtL9ST9kkQslq?zOpxo-JjOsQnAR0wZfOc5GWsfJYPLm5mmdvWN6w4RAM?yrCJQ Scale = 1:9.7 1 2 3 3x4 3x4 3x4 3-3-133-3-13 3-4-20-0-5 1-8-1 1-8-1 3-4-2 1-8-1 0-0-41-4-120-0-410.00 12 Plate Offsets (X,Y)-- [1:0-3-6,Edge], [2:0-2-0,Edge], [3:0-0-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-2 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-3-9, 3=3-3-9 Max Horz 1=-21(LC 6) Max Grav 1=111(LC 1), 3=111(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). August 4,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths