HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG96Rev. By Date CommentsDrawn By:DWChecked By: Date:08/05/2021Marin
25532
Sheet
1 of 1
Ceiling System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 2- 10dx1.5 - - No No No
H202 11 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes
H203 7 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No
H204 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No
H205 1 Simpson IUS2.37/11.88 Designed 10- 10d - 2- Strong-Grip - - No No No
H206 4 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No
Products
PlotID Length Product Plies Net Qty
FJ201 28' 0" 11 7/8" TJI 110 joist 1 5
FJ202 24' 0" 11 7/8" TJI 110 joist 1 4
FJ203 16' 0" 11 7/8" TJI 110 joist 1 2
FJ204 14' 0" 11 7/8" TJI 110 joist 1 3
FJ205 12' 0" 11 7/8" TJI 110 joist 1 12
FJ206 6' 0" 11 7/8" TJI 110 joist 1 4
FJ207 2' 0" 11 7/8" TJI 110 joist 1 1
FJ208 28' 0" 11 7/8" TJI 360 joist 1 1
FJ209 18' 0" 11 7/8" TJI 360 joist 1 11
BM201 22' 0" 1 3/4" x 24" 2.0E Microllam LVL 2 2
BM202 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 3 3
BM203 18' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2
BM204 14' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2
BM205 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6
Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 9
Blocking
PlotID Length Product Plies Net Qty
Bk201 2' 0" 11 7/8" TJI 110 joist 1 8
LEVEL NOTES
Current Date: 8/5/2021
File Name: TG96_25532.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2012
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 48
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ203(i1921)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 58, joist = FJ203(i1922)
FLOOR
Floor Container: FC2
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 48
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
CS
CS
CS
B4
B1
B4
B1
A3
A3
A3
A3
A3
A3
A3
H2
H2
H2
H2BBO8BBO7BM205
BM202BM204BM205BM205
PBO1 BBO12 BBO11
VO1
VO2
VO3
VO4
BM203
BM2011' 0" 2' 0" 1' 0" 2' 0" 1' 0" H202
H202
H202
H202
H202
H202
H202
H202
H202
H202
H202
H203
H203H203H203
H203
H203
H2031' 0" 2' 0" H204
H206
H1
H204
H205
H206
H204
H204
H1
H204
H206H204
H2069 1/2"1' 0 1/2"1' 5 7/16"11 9/16" 5' 1 1/8"9' 9 3/4"
Beam given 7 1/2" bearing for joist
connection.Flush beam depth greater than floor joist depth. Verifyall loading and framing conditions prior to construction.24" beam.6" bearing req.
There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
08/30/21