Loading...
HomeMy WebLinkAboutM003.016023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. August 18,2021 Liu, Xuegang Pages or sheets covered by this seal: I47495617 thru I47495647 My license renewal date for the state of Indiana is July 31, 2022. 25533-25533A TG96 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495617 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:13:51 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-l6hH24NTioR_ewLUhDikAuXF49sqPcYIg5U7yJymwEE Scale = 1:62.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 58 57 56 55 54 53 52 51 50 4948 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 59 60 5x6 5x6 5x6 3x6 3x6 3x6 3x6 35-2-035-2-0 -1-0-0 1-0-0 17-7-0 17-7-0 35-2-0 17-7-0 36-2-0 1-0-0 0-6-09-3-80-6-06.00 12 Plate Offsets (X,Y)-- [12:0-3-0,Edge], [20:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.04 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 31 31 30 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 218 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 16-45, 15-46, 17-44 REACTIONS.All bearings 35-2-0. (lb) - Max Horz 2=121(LC 14) Max Uplift All uplift 100 lb or less at joint(s) 2, 46, 47, 48, 49, 51, 52, 53, 54, 55, 56, 57, 58, 44, 43, 42, 41, 39, 38, 37, 36, 35, 34, 33, 32, 30 Max Grav All reactions 250 lb or less at joint(s) 2, 45, 46, 47, 48, 49, 51, 52, 53, 54, 55, 56, 57, 58, 44, 43, 42, 41, 39, 38, 37, 36, 35, 34, 33, 32, 30 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-6-3, Exterior(2N) 2-6-3 to 14-0-13, Corner(3R) 14-0-13 to 21-1-3 , Exterior(2N) 21-1-3 to 32-7-13, Corner(3E) 32-7-13 to 36-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 46, 47, 48, 49, 51, 52, 53, 54, 55, 56, 57, 58, 44, 43, 42, 41, 39, 38, 37, 36, 35, 34, 33, 32, 30. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A02 Truss Type Common Qty 2 Ply 1 TG96 Job Reference (optional) I47495618 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:13:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-54UA5nRbWL3HkhESUmIvtyExDARk4pT2qMCudXymwE9 Scale = 1:62.1 1 2 3 4 5 6 7 8 9 14 13 12 11 10 21 22 23 24 3x8 MT18HS 5x6 3x8 MT18HS 4x6 3x6 4x8 3x4 1.5x4 3x4 1.5x4 3x6 4x6 8-9-88-9-8 17-7-08-9-8 26-4-88-9-8 35-2-08-9-8 -1-0-0 1-0-0 8-9-8 8-9-8 17-7-0 8-9-8 26-4-8 8-9-8 35-2-0 8-9-8 36-2-0 1-0-0 0-6-09-3-80-6-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [8:Edge,0-0-13] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.82 0.57 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.30 0.10 0.08 (loc) 12-14 12-14 8 14-17 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 146 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x4 SP DSS BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-12, 3-12 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=121(LC 14) Max Uplift 2=-118(LC 14), 8=-118(LC 15) Max Grav 2=1467(LC 1), 8=1467(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2493/205, 3-5=-1707/216, 5-7=-1707/216, 7-8=-2493/205 BOT CHORD 2-14=-188/2133, 12-14=-188/2133, 10-12=-89/2133, 8-10=-89/2133 WEBS 5-12=-2/932, 7-12=-894/208, 7-10=0/352, 3-12=-894/207, 3-14=0/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-6-3, Interior(1) 2-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 32-7-13, Exterior(2E) 32-7-13 to 36-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=118, 8=118. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A03 Truss Type Common Qty 1 Ply 1 TG96 Job Reference (optional) I47495619 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:13:58 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-1ScwWTSs2yJ?z_OrbBKNyNJHi_7DYjvKHgh?hPymwE7 Scale = 1:61.6 1 2 3 4 5 6 7 8 13 12 11 10 9 20 21 22 23 3x8 MT18HS 5x6 3x8 MT18HS 4x6 3x6 4x8 3x4 1.5x4 3x4 1.5x4 4x6 3x6 8-9-88-9-8 17-7-08-9-8 26-4-88-9-8 35-2-08-9-8 -1-0-0 1-0-0 8-9-8 8-9-8 17-7-0 8-9-8 26-4-8 8-9-8 35-2-0 8-9-8 0-6-09-3-80-6-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [8:Edge,0-0-13] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.82 0.57 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.30 0.10 0.08 (loc) 9-11 11-13 8 9-19 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 144 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x4 SP DSS BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-11, 3-11 REACTIONS. (size)2=0-3-8, 8=Mechanical Max Horz 2=128(LC 14) Max Uplift 2=-118(LC 14), 8=-101(LC 15) Max Grav 2=1468(LC 1), 8=1406(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2495/208, 3-5=-1709/218, 5-7=-1709/218, 7-8=-2499/213 BOT CHORD 2-13=-195/2135, 11-13=-195/2135, 9-11=-119/2140, 8-9=-119/2140 WEBS 5-11=-5/934, 7-11=-899/209, 7-9=0/353, 3-11=-894/207, 3-13=0/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-6-3, Interior(1) 2-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 31-7-13, Exterior(2E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=118, 8=101. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A04 Truss Type Roof Special Qty 1 Ply 1 TG96 Job Reference (optional) I47495620 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-_rjgx9U6aZZjDIXDjcMr1oOgInpv0aVdl_A6mIymwE5 Scale = 1:62.0 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 24 25 26 27 3x6 5x6 3x8 MT18HS 5x6 3x4 3x4 3x4 3x4 3x6 3x4 5x6 5x9 5x6 5x9 3x4 4x6 8-9-88-9-8 15-6-06-8-8 19-0-03-6-0 26-4-87-4-8 35-2-08-9-8 -1-0-0 1-0-0 8-9-8 8-9-8 15-6-0 6-8-8 17-7-0 2-1-0 19-0-0 1-5-0 26-4-8 7-4-8 35-2-0 8-9-8 0-6-09-3-80-6-02-0-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-5], [10:0-0-0,0-0-9], [14:0-3-4,0-2-0], [15:0-3-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.62 0.55 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.31 0.14 0.10 (loc) 14-15 14-15 10 17-20 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 163 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-16,7-13: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-7-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=Mechanical Max Horz 2=128(LC 14) Max Uplift 2=-118(LC 14), 10=-101(LC 15) Max Grav 2=1468(LC 1), 10=1406(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2476/202, 3-5=-2433/247, 5-6=-2370/308, 6-7=-2279/311, 7-9=-2341/245, 9-10=-2486/208 BOT CHORD 2-17=-185/2113, 5-15=-398/130, 14-15=-17/1765, 7-14=-472/155, 10-11=-112/2123 WEBS 3-17=-461/144, 15-17=-200/2171, 11-14=-126/2162, 9-14=-262/169, 9-11=-397/128, 6-15=-181/1188, 6-14=-177/1222 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-6-3, Interior(1) 2-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 31-7-13, Exterior(2E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=118, 10=101. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A05 Truss Type ROOF SPECIAL Qty 1 Ply 1 TG96 Job Reference (optional) I47495621 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:03 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-OQPpZAW_tUxH4mGoOkwYfQ0BL?qcDxC3RyOmNdymwE2 Scale = 1:62.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 23 24 25 26 3x6 5x6 3x8 MT18HS 4x6 3x4 3x4 3x4 3x4 3x6 3x4 5x6 5x9 5x6 5x9 3x4 4x6 8-9-88-9-8 15-6-06-8-8 19-0-03-6-0 26-4-87-4-8 35-2-08-9-8 8-9-8 8-9-8 15-6-0 6-8-8 17-7-0 2-1-0 19-0-0 1-5-0 26-4-8 7-4-8 35-2-0 8-9-8 0-6-09-3-80-6-02-0-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-9], [9:0-0-0,0-0-9], [13:0-3-4,0-2-0], [14:0-3-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.63 0.55 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.31 0.14 0.10 (loc) 13-14 13-14 9 16-19 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 162 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 4-15,6-12: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 9=Mechanical Max Horz 1=115(LC 14) Max Uplift 1=-101(LC 14), 9=-101(LC 15) Max Grav 1=1407(LC 1), 9=1407(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2483/211, 2-4=-2436/251, 4-5=-2373/311, 5-6=-2281/315, 6-8=-2344/249, 8-9=-2487/211 BOT CHORD 1-16=-188/2120, 4-14=-397/129, 13-14=-18/1767, 6-13=-472/155, 9-10=-114/2125 WEBS 2-16=-461/144, 14-16=-202/2179, 10-13=-128/2163, 8-13=-262/169, 8-10=-397/129, 5-14=-182/1190, 5-13=-177/1222 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-6-3, Interior(1) 3-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 31-7-13, Exterior(2E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=101, 9=101. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A06 Truss Type Roof Special Qty 1 Ply 1 TG96 Job Reference (optional) I47495622 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:04 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-sczBmWXceo38hwr_ySRnCeZL5PAryOSDfc8Jv3ymwE1 Scale = 1:62.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 23 24 25 26 3x6 5x6 3x8 MT18HS 4x6 3x4 3x4 3x4 3x4 3x6 3x4 5x6 5x9 5x6 5x9 3x4 4x6 8-9-88-9-8 15-6-06-8-8 19-0-03-6-0 26-4-87-4-8 35-2-08-9-8 8-9-8 8-9-8 15-6-0 6-8-8 17-7-0 2-1-0 19-0-0 1-5-0 26-4-8 7-4-8 35-2-0 8-9-8 0-6-09-3-80-6-02-0-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-9], [9:0-0-0,0-0-9], [13:0-3-4,0-2-0], [14:0-3-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.63 0.55 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.31 0.14 0.10 (loc) 13-14 13-14 9 16-19 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 162 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 4-15,6-12: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 3-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 9=Mechanical Max Horz 1=115(LC 18) Max Uplift 1=-101(LC 14), 9=-101(LC 15) Max Grav 1=1407(LC 1), 9=1407(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2483/211, 2-4=-2436/251, 4-5=-2373/311, 5-6=-2281/315, 6-8=-2344/249, 8-9=-2487/211 BOT CHORD 1-16=-188/2120, 4-14=-397/129, 13-14=-18/1767, 6-13=-472/155, 9-10=-114/2125 WEBS 2-16=-461/144, 14-16=-202/2179, 10-13=-128/2163, 8-13=-262/169, 8-10=-397/129, 5-14=-182/1190, 5-13=-177/1222 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-6-3, Interior(1) 3-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 31-7-13, Exterior(2E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=101, 9=101. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A07 Truss Type Common Qty 7 Ply 1 TG96 Job Reference (optional) I47495623 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-o?5xBCZt9PKsxD?N3tTFH3eenCs5QKuW7wdQ_xymwE? Scale = 1:61.5 1 2 3 4 5 6 7 12 11 10 9 8 19 20 21 22 3x8 MT18HS 5x6 3x8 MT18HS 4x6 3x6 4x8 3x4 1.5x4 3x4 1.5x4 4x6 3x6 8-9-88-9-8 17-7-08-9-8 26-4-88-9-8 35-2-08-9-8 8-9-8 8-9-8 17-7-0 8-9-8 26-4-8 8-9-8 35-2-0 8-9-8 0-6-09-3-80-6-06.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-1], [7:0-0-0,0-1-1] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.81 0.57 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.29 0.10 0.08 (loc) 10-12 10-12 7 12-15 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 142 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x4 SP DSS BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-10, 2-10 REACTIONS. (size)1=Mechanical, 7=Mechanical Max Horz 1=115(LC 14) Max Uplift 1=-101(LC 14), 7=-101(LC 15) Max Grav 1=1407(LC 1), 7=1407(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2501/216, 2-4=-1711/221, 4-6=-1711/221, 6-7=-2501/216 BOT CHORD 1-12=-197/2142, 10-12=-197/2142, 8-10=-122/2142, 7-8=-122/2142 WEBS 4-10=-8/936, 6-10=-900/210, 6-8=0/353, 2-10=-900/209, 2-12=0/353 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-6-3, Interior(1) 3-6-3 to 14-0-13, Exterior(2R) 14-0-13 to 21-1-3, Interior(1) 21-1-3 to 31-7-13, Exterior(2E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=101, 7=101. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss A08 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495624 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:10 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-hmKS1acNDeqIQrI8IiYBRvpWspLZMCF52Ybe6jymwDx Scale = 1:61.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 57 58 5x6 5x6 5x6 3x6 3x6 3x6 3x6 35-2-035-2-0 17-7-0 17-7-0 35-2-0 17-7-0 0-6-09-3-80-6-06.00 12 Plate Offsets (X,Y)-- [11:0-3-0,Edge], [19:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.04 0.02 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 29 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 216 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-43, 14-44, 16-42 REACTIONS.All bearings 35-2-0. (lb) - Max Horz 1=117(LC 14) Max Uplift All uplift 100 lb or less at joint(s) 1, 44, 45, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 42, 41, 40, 39, 37, 36, 35, 34, 33, 32, 31, 30 Max Grav All reactions 250 lb or less at joint(s) 1, 43, 44, 45, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 42, 41, 40, 39, 37, 36, 35, 34, 33, 32, 31, 30, 29 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-0-0 to 3-6-3, Exterior(2N) 3-6-3 to 14-0-13, Corner(3R) 14-0-13 to 21-1-3, Exterior(2N) 21-1-3 to 31-7-13, Corner(3E) 31-7-13 to 35-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 44, 45, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 42, 41, 40, 39, 37, 36, 35, 34, 33, 32, 31, 30. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss B01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495625 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:15 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-2k7L4HgW2ASaWcB65G8M8yWKKq0e1RorBqIPnwymwDs Scale = 1:52.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 29 27 26 25 24 23 22 21 20 30 31 32 33 42 43 28 4x6 3x6 4x4 3x6 4x4 5x9 4x4 5-3-85-3-8 7-7-82-4-0 10-3-82-8-0 14-11-84-8-0 22-7-07-7-8 -1-0-0 1-0-0 5-3-8 5-3-8 5-9-8 0-6-0 11-3-8 5-6-0 16-9-8 5-6-0 22-7-0 5-9-8 23-7-0 1-0-0 0-8-08-2-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3], [18:0-3-1,0-0-3], [27:0-4-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.25 0.16 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.03 0.01 0.02 (loc) 29-36 29-36 18 29-36 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 132 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 2-29,28-29,27-28. JOINTS 1 Brace at Jt(s): 31 REACTIONS.All bearings 12-3-8 except (jt=length) 2=0-3-8, 28=0-3-8. (lb) - Max Horz 2=159(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 18, 26, 25, 24, 23, 22, 21, 20 except 27=-124(LC 12) Max Grav All reactions 250 lb or less at joint(s) 18, 26, 25, 24, 23, 22, 21, 20, 28, 18 except 2=491(LC 1), 27=493(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-343/79 BOT CHORD 2-29=-85/406, 28-29=-85/406, 27-28=-85/406 WEBS 9-27=-281/22, 4-33=-479/164, 32-33=-407/124, 31-32=-438/141, 30-31=-459/155, 27-30=-450/150 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-3-8, Exterior(2R) 8-3-8 to 14-3-8, Interior(1) 14-3-8 to 20-7-0, Exterior(2E) 20-7-0 to 23-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 26, 25, 24, 23, 22, 21, 20, 18 except (jt=lb) 27=124. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss B02 Truss Type Common Qty 3 Ply 1 TG96 Job Reference (optional) I47495626 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:17 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-_6F6VzhmaoiIlvLUDgAqDNbfBeZLVLU7f7nVrpymwDq Scale = 1:48.6 1 2 3 4 5 6 7 8 9 10 19 20 5x6 4x4 6x10 4x4 1.5x4 1.5x4 5x6 4x4 11-3-811-3-8 22-7-011-3-8 -1-0-0 1-0-0 5-7-12 5-7-12 11-3-8 5-7-12 16-11-4 5-7-12 22-7-0 5-7-12 23-7-0 1-0-0 0-8-08-2-50-8-08.00 12 Plate Offsets (X,Y)-- [10:0-5-0,0-3-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.29 0.72 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.21 -0.42 0.02 0.03 (loc) 10-17 10-13 8 10-13 l/defl >999 >641 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-159(LC 10) Max Uplift 2=-74(LC 12), 8=-74(LC 13) Max Grav 2=963(LC 1), 8=963(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1057/130, 4-5=-924/112, 5-6=-924/112, 6-8=-1057/130 BOT CHORD 2-10=-116/946, 8-10=-22/944 WEBS 5-10=-0/639, 6-10=-341/178, 4-10=-341/177 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-3-8, Exterior(2R) 8-3-8 to 14-3-8, Interior(1) 14-3-8 to 20-7-0, Exterior(2E) 20-7-0 to 23-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss B03 Truss Type COMMON GIRDER Qty 1 Ply 3 TG96 Job Reference (optional) I47495627 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:21 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-suVcLKkHd0DkEXeGSWFmODmJSF_XR2Ijallj_aymwDm Scale = 1:50.9 1 2 3 4 5 8 7 6 15 16 17 18 19 20 21 22 23 24 25 26 8x8 8x8 8x12 4x6 4x6 3x6 4x6 3x6 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 5-7-125-7-12 11-3-85-7-12 16-11-45-7-12 22-7-05-7-12 5-7-12 5-7-12 11-3-8 5-7-12 16-11-4 5-7-12 22-7-0 5-7-12 0-8-08-2-50-8-08.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-3-13], [5:0-0-0,0-3-13], [6:0-4-8,0-1-8], [7:0-6-0,0-4-8], [8:0-4-8,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.34 0.51 0.69 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.11 -0.22 0.05 0.07 (loc) 7-8 7-8 5 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 352 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8 (req. 0-4-11), 5=0-3-8 (req. 0-4-4) Max Horz 1=-146(LC 8) Max Uplift 1=-708(LC 12), 5=-642(LC 13) Max Grav 1=8950(LC 1), 5=8112(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-11528/935, 2-3=-7982/706, 3-4=-7981/706, 4-5=-11478/931 BOT CHORD 1-8=-799/9501, 7-8=-799/9501, 6-7=-719/9457, 5-6=-719/9457 WEBS 3-7=-667/8390, 4-7=-3565/401, 4-6=-242/3717, 2-7=-3619/405, 2-8=-245/3771 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-3-8, Exterior(2R) 8-3-8 to 14-3-8, Interior(1) 14-3-8 to 19-7-0, Exterior(2E) 19-7-0 to 22-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) WARNING: Required bearing size at joint(s) 1, 5 greater than input bearing size. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=708, 5=642. 10) Use MiTek HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 0-7-12 from the left end to 20-7-12 to connect truss(es) to back face of bottom chord. 11) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) StandardContinued on page 2 SUPPLEMENTARY BEARING PLATES, SPECIAL ANCHORAGE, OR OTHER MEANS TO ALLOW FOR THE MINIMUM REQUIRED SUPPORT WIDTH (SUCH AS COLUMN CAPS, BEARING BLOCKS, ETC.) ARE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER OR THE BUILDING DESIGNER. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss B03 Truss Type COMMON GIRDER Qty 1 Ply 3 TG96 Job Reference (optional) I47495627 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:21 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-suVcLKkHd0DkEXeGSWFmODmJSF_XR2Ijallj_aymwDm LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 9-12=-20 Concentrated Loads (lb) Vert: 6=-1387(B) 17=-1389(B) 18=-1386(B) 19=-1387(B) 20=-1387(B) 21=-1387(B) 22=-1387(B) 23=-1387(B) 24=-1387(B) 25=-1387(B) 26=-1387(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss C01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495628 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-L42?YglvOKLbshDS?Em?wQJYGfR7AfSsoPVGX0ymwDl Scale = 1:38.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 31 32 4x4 3x4 5x6 3x4 20-8-020-8-0 -1-0-0 1-0-0 10-4-0 10-4-0 20-8-0 10-4-0 21-8-0 1-0-0 0-6-05-8-00-6-06.00 12 Plate Offsets (X,Y)-- [24:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.08 0.04 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 16 16 16 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-8-0. (lb) - Max Horz 2=74(LC 14) Max Uplift All uplift 100 lb or less at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18, 16 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 7-4-0, Corner(3R) 7-4-0 to 13-4-0, Exterior(2N) 13-4-0 to 18-8-0, Corner(3E) 18-8-0 to 21-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 22, 21, 20, 19, 18, 16. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss C02 Truss Type Common Qty 3 Ply 1 TG96 Job Reference (optional) I47495629 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-HTAlzMn9wxbJ5_Nq7foT?rOq9Tz2eV39Gj_NbvymwDj Scale = 1:37.9 1 2 3 4 5 6 7 8 15 16 17 18 4x6 5x9 4x6 1.5x4 1.5x4 4x6 10-4-010-4-0 20-8-010-4-0 -1-0-0 1-0-0 5-2-0 5-2-0 10-4-0 5-2-0 15-6-0 5-2-0 20-8-0 5-2-0 21-8-0 1-0-0 0-6-05-8-00-6-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [6:0-0-0,0-1-1], [8:0-4-8,0-3-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.37 0.65 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.16 -0.34 0.03 0.03 (loc) 8-14 8-14 6 8 l/defl >999 >739 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 73 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 5-10-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-5-8 Max Horz 2=74(LC 14) Max Uplift 2=-77(LC 14), 6=-77(LC 15) Max Grav 2=927(LC 21), 6=927(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1469/223, 3-4=-1048/155, 4-5=-1048/155, 5-6=-1469/223 BOT CHORD 2-8=-130/1268, 6-8=-123/1268 WEBS 4-8=0/590, 5-8=-491/164, 3-8=-491/164 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-4-0, Exterior(2R) 7-4-0 to 13-4-0, Interior(1) 13-4-0 to 18-8-0, Exterior(2E) 18-8-0 to 21-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss D01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495630 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-DrIVO2oQSZr1KIXDE3qx5GTEpGpG6SySj1TUgnymwDh Scale = 1:41.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x6 4x4 3x6 5x6 17-8-017-8-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 18-8-0 1-0-0 0-8-06-6-110-8-08.00 12 Plate Offsets (X,Y)-- [25:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 94 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 17-8-0. (lb) - Max Horz 32=-139(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 32, 18, 26, 27, 28, 29, 30, 31, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 32, 18, 25, 26, 27, 28, 29, 30, 31, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-2-0, Exterior(2N) 2-2-0 to 5-10-0, Corner(3R) 5-10-0 to 11-10-0, Exterior(2N) 11-10-0 to 15-6-0, Corner(3E) 15-6-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 32, 18, 26, 27, 28, 29, 30, 31, 24, 23, 22, 21, 20, 19. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss D02 Truss Type Common Qty 2 Ply 1 TG96 Job Reference (optional) I47495631 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:27 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-h1subOp2DsztyS6PonLAdU0Ofg2IruQcyhC1CEymwDg Scale = 1:39.2 1 2 3 4 5 6 7 8 9 10 19 20 21 22 4x6 4x4 5x9 4x4 1.5x4 1.5x4 4x6 4x4 8-10-08-10-0 17-8-08-10-0 -1-0-0 1-0-0 4-5-0 4-5-0 8-10-0 4-5-0 13-3-0 4-5-0 17-8-0 4-5-0 18-8-0 1-0-0 0-8-06-6-110-8-08.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-0-3], [8:0-2-13,0-0-3], [10:0-4-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.16 0.42 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.16 0.02 0.01 (loc) 10-13 10-13 8 10-13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=127(LC 11) Max Uplift 2=-62(LC 12), 8=-62(LC 13) Max Grav 2=767(LC 1), 8=767(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-870/105, 4-5=-710/92, 5-6=-710/92, 6-8=-870/105 BOT CHORD 2-10=-87/721, 8-10=-14/716 WEBS 5-10=-1/485, 6-10=-253/136, 4-10=-253/136 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-10-0, Exterior(2R) 5-10-0 to 11-10-0, Interior(1) 11-10-0 to 15-8-0, Exterior(2E) 15-8-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss D03 Truss Type COMMON GIRDER Qty 1 Ply 3 TG96 Job Reference (optional) I47495632 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-6cX0DPrwWnLSpvq_TvvtF6euGt5b2B42efRhpYymwDd Scale = 1:40.4 1 2 3 4 5 6 9 8 7 16 17 18 19 20 21 22 23 24 25 8x8 5x6 5x6 8x8 1.5x4 8x8 1.5x4 8x8 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 5-11-85-11-8 11-8-85-8-15 17-8-05-11-8 4-6-4 4-6-4 8-10-0 4-3-12 13-1-12 4-3-12 17-8-0 4-6-4 18-8-0 1-0-0 0-8-06-6-110-8-08.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-3-13], [5:Edge,0-3-13], [7:0-4-0,0-4-8], [9:0-4-0,0-4-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.20 0.38 0.39 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.15 0.02 0.05 (loc) 7-9 7-9 5 7-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 272 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-123(LC 36) Max Uplift 1=-499(LC 12), 5=-509(LC 13) Max Grav 1=6301(LC 1), 5=6266(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-8312/689, 2-3=-8182/726, 3-4=-8180/723, 4-5=-8310/687 BOT CHORD 1-9=-574/6844, 7-9=-333/4734, 5-7=-502/6840 WEBS 3-7=-429/4820, 3-9=-431/4823 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 5-10-0, Exterior(2R) 5-10-0 to 11-10-0, Interior(1) 11-10-0 to 15-8-0, Exterior(2E) 15-8-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=499, 5=509. 10) Use MiTek HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-8-12 from the left end to 15-8-12 to connect truss(es) to front face of bottom chord. 11) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Continued on page 2 August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss D03 Truss Type COMMON GIRDER Qty 1 Ply 3 TG96 Job Reference (optional) I47495632 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:30 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-6cX0DPrwWnLSpvq_TvvtF6euGt5b2B42efRhpYymwDd LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-6=-60, 10-13=-20 Concentrated Loads (lb) Vert: 7=-1387(F) 9=-1387(F) 20=-1387(F) 21=-1387(F) 22=-1387(F) 23=-1387(F) 24=-1387(F) 25=-1387(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss E01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495633 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:31 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-ap5ORlsYH5TJR3PB1dQ6oKB44HWRnk6BtJAFL?ymwDc Scale = 1:26.8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x6 4x4 3x6 10-7-010-7-0 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-04-2-50-8-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.02 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-7-0. (lb) - Max Horz 20=-94(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Corner(3R) 2-0-0 to 8-7-0, Corner(3E) 8-7-0 to 11-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 1-4-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss E02 Truss Type Common Qty 2 Ply 1 TG96 Job Reference (optional) I47495634 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-2?fne5tA2PbA2D_NbKxLKXjD9ho0WBvL5zwotRymwDb Scale = 1:27.0 1 2 3 4 5 6 7 8 17 18 3x6 4x4 3x6 4x4 1.5x4 4x4 5-3-85-3-8 10-7-05-3-8 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-04-2-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-0-3], [6:0-3-5,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.31 0.26 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.04 0.01 0.03 (loc) 8-15 8-15 2 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0, Right 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=81(LC 11) Max Uplift 2=-44(LC 12), 6=-44(LC 13) Max Grav 2=483(LC 1), 6=483(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-413/94, 4-6=-413/94 BOT CHORD 2-8=0/308, 6-8=0/308 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 8-7-0, Exterior(2E) 8-7-0 to 11-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M01 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495635 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-WBD9sRupoij1gNZZ91SatlGQc5BwFeUUKdfMQtymwDa Scale = 1:23.5 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 20 3x4 -1-0-0 1-0-0 11-3-8 11-3-8 0-4-84-7-54.50 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.13 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-3-8. (lb) - Max Horz 2=146(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 11, 2, 12, 13, 14, 15, 16, 17, 18 Max Grav All reactions 250 lb or less at joint(s) 11, 2, 12, 13, 14, 15, 16, 17, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 1-11-8, Exterior(2N) 1-11-8 to 8-1-12, Corner(3E) 8-1-12 to 11-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2, 12, 13, 14, 15, 16, 17, 18. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M02 Truss Type Monopitch Qty 5 Ply 1 TG96 Job Reference (optional) I47495636 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-_OnX3nuRZ0ruIX8lilzpPypWaVSW__QeZHPvyKymwDZ Scale = 1:25.7 1 2 3 4 6 5 10 11 12 3x4 3x4 4x4 1.5x4 4x6 5-7-125-7-12 11-3-85-7-12 -1-0-0 1-0-0 5-7-12 5-7-12 11-3-8 5-7-12 0-4-84-7-54-3-130-3-84-7-54.50 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.50 0.32 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.06 0.01 0.02 (loc) 5-6 5-6 5 6-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-5: 2x6 SP DSS BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 5=0-1-8 Max Horz 2=145(LC 13) Max Uplift 2=-66(LC 10), 5=-66(LC 14) Max Grav 2=551(LC 21), 5=565(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-889/140 BOT CHORD 2-6=-122/808, 5-6=-122/808 WEBS 3-6=0/259, 3-5=-872/197 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-0-12, Exterior(2E) 8-0-12 to 11-0-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 5. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M03 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495637 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-SaLvH7v3KKzlvgjyGSV2yALm4ut0jY9nox8SUmymwDY Scale = 1:25.4 1 2 3 4 5 6 11 10 9 8 7 3x6 -1-0-0 1-0-0 5-4-8 5-4-8 0-8-04-3-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.05 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-4-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 5-4-8. (lb) - Max Horz 11=122(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 11, 7, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 11, 7, 8, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7, 8, 9, 10. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M04 Truss Type Monopitch Qty 4 Ply 1 TG96 Job Reference (optional) I47495638 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-wmvHUTwh5d6cXqI8qA0HVNutQI9sS?jw0bu00CymwDX Scale = 1:26.4 1 2 3 4 5 1.5x4 3x6 3x4 1.5x4 -1-0-0 1-0-0 5-4-8 5-4-8 0-8-04-3-03-11-80-3-84-3-08.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.35 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.08 0.02 0.04 (loc) 5-8 5-8 2 5-8 l/defl >999 >807 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 1-6-0 BRACING- TOP CHORD Sheathed or 5-4-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 5=0-1-8 Max Horz 2=119(LC 11) Max Uplift 2=-23(LC 12), 5=-45(LC 12) Max Grav 2=275(LC 1), 5=218(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M05 Truss Type Monopitch Qty 8 Ply 1 TG96 Job Reference (optional) I47495639 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-wmvHUTwh5d6cXqI8qA0HVNusZI9RS?jw0bu00CymwDX Scale = 1:13.9 1 2 3 4 1.5x4 3x4 1.5x4 4-11-84-11-8 -1-0-0 1-0-0 4-11-8 4-11-8 0-4-82-2-131-11-50-3-82-2-134.50 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.41 0.29 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.04 -0.07 0.00 0.02 (loc) 4-7 4-7 2 4-7 l/defl >999 >827 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=68(LC 13) Max Uplift 2=-48(LC 10), 4=-27(LC 14) Max Grav 2=360(LC 21), 4=253(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss M06 Truss Type GABLE Qty 1 Ply 1 TG96 Job Reference (optional) I47495640 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:37 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-OzSgioxJsxET9_sKOtXW1bQ65iZjBRa4FFdZZeymwDW Scale = 1:13.9 1 2 3 4 5 8 7 6 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 4-11-8 4-11-8 0-4-82-2-134.50 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 4-11-8. (lb) - Max Horz 2=67(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 7, 8. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V01 Truss Type Valley Qty 2 Ply 1 TG96 Job Reference (optional) I47495641 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-t902v8xxdEMKn8RXxb2laozI96vqwuDDUvN755ymwDV Scale = 1:7.7 1 2 3 3x4 3x4 3x4 0-0-60-0-6 3-0-02-11-10 1-6-0 1-6-0 3-0-0 1-6-0 0-0-41-0-00-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-11-4, 3=2-11-4 Max Horz 1=13(LC 11) Max Uplift 1=-5(LC 12), 3=-5(LC 13) Max Grav 1=81(LC 1), 3=81(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V02 Truss Type Valley Qty 2 Ply 1 TG96 Job Reference (optional) I47495642 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-t902v8xxdEMKn8RXxb2laozHs6vcwuzDUvN755ymwDV Scale = 1:14.7 1 2 3 4 3x4 4x4 3x4 1.5x4 0-0-60-0-6 6-0-05-11-10 3-0-0 3-0-0 6-0-0 3-0-0 0-0-42-0-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.05 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-11-4, 3=5-11-4, 4=5-11-4 Max Horz 1=-32(LC 8) Max Uplift 1=-18(LC 12), 3=-22(LC 13) Max Grav 1=108(LC 1), 3=108(LC 1), 4=187(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V03 Truss Type Valley Qty 2 Ply 1 TG96 Job Reference (optional) I47495643 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-LLaQ6UyZOYUAOI0jVIZ_60WPuWDYfLzNiZ6gdXymwDU Scale = 1:20.4 1 2 3 43x4 4x4 3x4 1.5x4 0-0-60-0-6 9-0-08-11-10 4-6-0 4-6-0 9-0-0 4-6-0 0-0-43-0-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.14 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-11-4, 3=8-11-4, 4=8-11-4 Max Horz 1=-52(LC 8) Max Uplift 1=-28(LC 12), 3=-35(LC 13) Max Grav 1=172(LC 1), 3=172(LC 1), 4=299(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 5-6-4, Exterior(2E) 5-6-4 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V04 Truss Type Valley Qty 2 Ply 1 TG96 Job Reference (optional) I47495644 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-pY8oKqzC9sc10Sbv304DfD2WOvWvOnfWxCsD9zymwDT Scale = 1:25.7 1 2 3 4 5 6 3x4 4x4 3x4 1.5x4 0-0-60-0-6 12-0-011-11-10 6-0-0 6-0-0 12-0-0 6-0-0 0-0-44-0-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.55 0.26 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=11-11-4, 3=11-11-4, 4=11-11-4 Max Horz 1=71(LC 11) Max Uplift 1=-39(LC 12), 3=-48(LC 13) Max Grav 1=236(LC 1), 3=236(LC 1), 4=410(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-272/87 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 8-6-4, Exterior(2E) 8-6-4 to 11-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V05 Truss Type Valley Qty 2 Ply 1 TG96 Job Reference (optional) I47495645 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-HkiAXA_qw9kuebA6djcSCRbnCJv_7EtfAsbniQymwDS Scale = 1:31.6 1 2 3 4 5 8 7 6 9 10 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-60-0-6 15-0-014-11-10 7-6-0 7-6-0 15-0-0 7-6-0 0-0-45-0-00-0-48.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.16 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-11-4. (lb) - Max Horz 1=-91(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-103(LC 12), 6=-102(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=259(LC 1), 8=337(LC 19), 6=337(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-254/143, 4-6=-254/143 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-6-0, Interior(1) 3-6-0 to 4-6-0, Exterior(2R) 4-6-0 to 10-6-0, Interior(1) 10-6-0 to 11-6-0, Exterior(2E) 11-6-0 to 14-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=103, 6=102. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V06 Truss Type Valley Qty 1 Ply 1 TG96 Job Reference (optional) I47495646 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-HkiAXA_qw9kuebA6djcSCRbm?Jug7EWfAsbniQymwDS Scale = 1:38.1 1 2 3 4 5 8 7 6 9 10 11 12 13 143x4 4x4 3x4 5x6 1.5x4 1.5x4 1.5x4 1.5x4 0-0-60-0-6 18-0-017-11-10 9-0-0 9-0-0 18-0-0 9-0-0 0-0-46-0-00-0-48.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.23 0.16 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-11-4. (lb) - Max Horz 1=-110(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-124(LC 12), 6=-124(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=330(LC 22), 8=508(LC 19), 6=506(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-308/167, 4-6=-308/167 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 14-6-4, Exterior(2E) 14-6-4 to 17-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=124, 6=124. August 18,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25533-25533A Truss V07 Truss Type Valley Qty 1 Ply 1 TG96 Job Reference (optional) I47495647 8.510 s Jun 18 2021 MiTek Industries, Inc. Tue Aug 17 14:14:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:sLjZlgVPs_uewrI0PKiUcgyn_cE-lwGZlW?ShTslFllIAQ7hke8yCjE8sg5pPWLKEsymwDR Scale = 1:44.4 1 2 3 4 5 6 7 12 11 10 9 8 13 14 3x4 4x4 3x4 5x6 0-0-60-0-6 21-0-020-11-10 10-6-0 10-6-0 21-0-0 10-6-0 0-0-47-0-00-0-48.00 12 Plate Offsets (X,Y)-- [10:0-3-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.14 0.14 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-11-4. (lb) - Max Horz 1=-129(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 12, 8 except 11=-106(LC 12), 9=-107(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=373(LC 22), 11=448(LC 19), 12=320(LC 19), 9=445(LC 20), 8=321(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-273/156, 5-9=-273/156 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 7-6-0, Exterior(2R) 7-6-0 to 13-6-0, Interior(1) 13-6-0 to 17-6-4, Exterior(2E) 17-6-4 to 20-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 12, 8 except (jt=lb) 11=106, 9=107. August 18,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths