Loading...
HomeMy WebLinkAboutM004.0Truss Connector Total ListManufProduct QtyMiTekHUS2619USP RT7A*80Ceiling2' Mech. M03 C01M01M06(4) M04(3) C02(5) M02(8) M05(11) HUS26B03E01B01 (8) HUS26D03D01A01A03A04A05A06A08V01V02V03V04V05V01V02V03 V04V05V06V07 (2) E02(3) B02(2) D02(2) A02 (7) A0735-10-0010-04-00 17-08-00 7-10-001-00-001-00-001-00-001-00-0059-08-005-00-0028-00-00 6-04-0021-08-00 20-08-00 13-06-00 7-02-00 6-00-00 1-00-001-00-001-00-001-00-001-00-0035-10-005-05-00 10-07-00 12-00-00 7-10-001-00-00 1-00-001-00-001-00-001-00-00 59-08-005-00-00 8-02-00 35-02-00 11-04-006-04-00 5-00-001-00-00 1-00-00 1-00-001-00-001-00-00 IMPORTANTTHISDRAWINGISFOR FIELD PLACEMENT OF INDIVIDUALCOMPONENTSONLY,AND DOESNOT CONSTITUTE ANENGINEERED DOCUMENT.NOTEPROPER BEARINGAND BEARINGDESIGN INCLUDINGANCHORAGE,ISTHE RESPONSIBILITY OF THE BUILDINGDESIGNER,ARCHITECT AND /OR BUILDINGENGINEER. REFERTO INDIVIDUAL TRUSSDESIGNSFOR REACTIONS,MINIMUMREQUIRED BEARINGSIZE,UPLIFT,AND ADDITIONAL LOADS.84COMPONENTSDOESNOT ASSUME RESPONSIBILITY INTHESE AREASOF CONCERN.BRACINGERECTION,TEMPORARY,AND PERMANENT BRACINGISTHERESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDINGDESIGNER. REFER TO INDIVIDUAL TRUSSDESIGNSFORADDITIONAL BRACINGREQUIREMENTS. REFER TO BCSI-B1SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTSASSOCIATION COMMENTARY,AND RECOMMENDATIONSFORHANDLING,INSTALLING&BRACINGMETAL PLATE CONNECTEDWOOD TRUSSES. www.sbcindustry.comINSTALLATIONDO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONSCALL 84COMPONENTS. PROPER INSTALLATION,ANDHANDLINGOF COMPONENTSISTHE RESPONSIBILITY OF THEERECTINGCONTRACTOR. 84COMPONENTSMUST BENOTIFIED OF ANY PROBLEMS,AND AFFORDED THEOPPORTUNITY TO REVIEW,AND MAKE NECESSARYCORRECTIONS,OR NO BACK CHARGESWILL BE ACCEPTEDOR APPROVED.WARNINGWARNINGS,AND INSTRUCTIONSFOR ERECTIONOF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE.KEEP THISINFORMATION ON THE JOB SITE. THESEDOCUMENTSWILL ALSO BE NEEDED FOR JOB SITEINSPECTION. MISUSE AND IMPROPER INSTALLATION OFCOMPONENTSMAY RESULT IN FAILURE,BODILY INJURY,LOSSOF PROPERTY,AND /OR LIFE.RoofArea: Overhang Length: Eave Length: HipLength:ValleyLength: Ridge Length: SHEETNUMBER:R1.1RoofTrussPlacementPlanSCALE: NTSJob#: 25533APO#:Date: 8/17/2021Drawn By: MMDesigned By: MMChecked By:ROOF LOADS:TCLL: 20.0 lb/ft²TCDL: 10.0 lb/ft²BCLL: 0.0 lb/ft²BCDL:10.0 lb/ft²Building Code: IRC 2012Wind Speed: 115 mphOn-Center Spacing: 24"U.N.O.2289.92 SF113.58 LF210.65 LF0 LF79.43 LF87.83 LFROOFDATATHIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.TG96Marin6996 Pickett PlCarmel,Indiana 46033ROOFTRUSSPLACEMENTPLAN25533A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-091608/30/21