HomeMy WebLinkAboutMechanical Plans4' -
wel
PLAN VIEW / MODEL 4524 - ND
ITEM #50 (MAIN LINE)
PLAN VIEW / MODFL 4524- ND
ITEM #50A (ROTISSERIE LINE)
HOOD INFORMATION SCHEDULE
AIR REQUIREMENTS
FILTERS
LIGHTS
FIRE SYSTEM
ELECTRICAL PREWIRE
EXHAUST
SUPPLY
HOOD
H000
HOOD
COOKING
DUCT
DUCT
'
LENGTH
CONST.
WEIGHT
TEMP.
SIZE
SIZE
�
LOCATION
OF
W
PREWIRE
SWITCH
QTY,
CFM
S.P.
QTY.
CFM S.P
Q'TY
LENGTH
TYPE
Q'TY
TYPE
TYPE
OCATION
WITCHES
L
W
L
PACKAGE
PLATE
1 OF 4
TYPE 304
4
16 INCH
U.L.
7'0"
1
10
9
1050
0.4`
N/A
N/A
N/A
N/A
N/A
S/STEEL
ALUM.
2
VAPOR-
NONE
N/A
N/A
N/A
N/A
300
450
4524-NO
EACH
EACH
I
WHERE
1
20 INCH
BAFFLE
PROOF
I
LBS.
DEG.
EXPOSED
I
I
I
INCAND.
2 OF 4
TYPE 304
4
16 INCH
U.L.
7 0"
1
10
9
i050
0.4"
N/A
NA
/
N A
/
N/A
NA
/
S/STEEL
ALUM.
2
VAPOR-
NONE
N/A
N/A
N/A
N/A
300
450
4524-NO
EACH
EACH
ERE
WERE
1
20 INCH
BAFFLE
1
PROOF
(
LBS.
I DEG.
EXPOSED
I INCAND.
3 OF 4
TYPE 304
4
16 INCH
U.L.
10'3"
1
10
13
1538
0. 4"
N/A
N/A
N/A
N/A
I
N/A
S/STEEL
ALUM.
3
VAPOR-
ANSUL
UTILITY
CABINET
N/A
N/A
N/A
425
450
4524-ND
EACH
EACH
I
WHERE
3
20 INCH
BAFFLE
PROOF
LBS.
DEG.
EXPOSED
INCAND.
HOOD #4
4 OF 4
TYPE 304
3
16 INCH
U.L.
UTILITY
UTILITY
UTILITY
1 LIGHT
10'6"
1
10
13
1575
0.4"
N/A
N/A
N/A
N/A
N/A
S/STEEL
I ALUM.
3
VAPOR-
ANSUL
CABINET
CABINET
CABINET
1 FAN
575
4.50
4524-ND
EACH
EACH
WHERE
4
20 INCH
BAFFLE
PROOF
RIGHT
RIGHT
RIGHT
0 S/W
LBS.
DEC.
EXPOSED
I
I
I INCAND.
I
0 OTHER
1/2" DIA. ALL THREAD ROD
CONNECTED TO ROOF JOIST
THROUGH ANOTHER
HANGING ANGLE
STEEL HANGING ANGLE
1/2" DIA. HEAVY DUTY NUT
ONE ABOVE AND ONE BELOW
HANCINC ANGLE
ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR
HANGING ANGLE IS PRE -PUNCHED AT FACTORY
1" FLANGE FOR DUCT
CONNECTION
LOCKING QUADRANT
TO ADJUST AIR FLOW
9" MAX.
12` MA- X.
VOLUME DAMPER BLADE
1" FLANGE FOR
CONNECTION TO HOOD
EXTENDS 3" BELOW
TOP OF HOOD
U.L. FIRE DAMPER (INSIDE)
WITH 212 DEG. FUSIBLE LINK
1/2" FLATTENED HEM
1/2" FLATTENED HEM
S/ S MATING CUP
WITH 7/6" FLANGES (END -TO -END)
OR 7/8" FLANGES (BACK-TO-BACK)
(POP -RIVETED IN PLACE IN THE FIELD)
FRONT VIEW OF 2 P.C. HOOD CONNECTION
4NIZED
411
FOR
4TEGRAL 3" AIR SPACE
IANGER ANGLES (TYPICAL). FACTORY
OCATED & INSTALLED. PROVIDE GALVANIZED
HREADED RODS, NUTS, WASHERS, BEAM
:LAMPS, ANCHORS, ETC. AS R.EOUIRED FOR
JSTALLATION
kNSUL R-102 WET CHEMICAL
IRE SUPPRESSION SYSTEM
ACTORY PREWIRED 100 WATT
CANDESCENT LIGHT FIXTURE
ACTORY PREWIRED CONDUIT FROM
IRE SYSTEM MICRO -SWITCH TO
UPPLY FAN SHUT -DOWN RELAY
DREWIRED ELECTRICAL PANEL WITH
FAN STARTERS/OVERLOADS AND
SUPPLY FAN SHUT -DOWN RELAY.
(SEE DRAWING # HV-2 FOR
WIRING SCHEMATIC)
LIGHT & FAN SWITCH PREWIRED
TO CAS ELECTRICAL PANEL
WRAPPERS, 2-SIDES, 18"H
HOOD ACCESSORIES SCHEDULE
BACK RETURN
STANDOFF
WRAPPER
BACKSPLASH
-
HOOD
-
-
----
_
WIDTH
LENGTH
LOCATION
WIDTH
INSULATED
HEIGHT
INSTALLED
LOCATION
HEIGHT
LENGTH
INSULATED
FRONT
1
N/A
N/A
BACK
3"
NO
18"
FIELD
RIGHT
N/A
I N/A
N/A
2
N/A
I N/A
BACK
3"
NO
18"
FIELD
L FT
N/A
N/A
N/A
FRONT"
3
N/A
N/A
BACK
3
I NO
( 18"
FIELD
N/A
N/A
N/A
LEFT
I
_
FRONT
I
4
N/A
N/A
BACK
3"
NO
18
FIELD
RIGHT
N/A
N/A
N/A
1 /Y FLANGF THAT SLIPS
BETWEEN HOOD S
3/8" X 3/8' ANGLE
S/S CORNER STRIPPINC
1/2" MADE TRIM STRIP
TOP OF HOOD
r..� STEEL ANGLE WELDED TO
END OF EACH HOOD TO BE
\BOLTED TOGETHER TO DRAW
HOODS FLUSH TOGETHER.
BOLTS (OR THREADED ROD) AND
NUTS SUPPLIED BY CONTRACTOR
. �Z�I�Z�Z�P►1`if�1T�I►77�11
4"
3" UNINSULATED STANDOFF
HANGING ANGLE (TYPICAL)
EXHAUST RISER
16" U.L. CLASSIFIED
BAFFLE -TYPE
GREASE FILTERS
>LOPED GREASE DRAIN
WITH REMOVABLE CUP
— 48"
EQUIPMENT
RY OTHERS
100W VAPORPROOF
INCANDESCENT LIGHT WRAPPERS 18" H
ON RIGHT, LEFT, FROI`
24"
11.5- MIN
48" MAX
80 TYP.
I
SECTION VIEW / MODEL 4 524 - ND �
r-----------------------,,
** NOTE **
IT IS THE RESPONSIBILITY
I OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE '
FROM LIMITED -COMBUSTIBLE
AND NON-COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH THE
I LATEST EDITION OF NFPA 96. '
i (SEE TABLE)
MATERIAL CLEARANCE REDUCTION SYSTEM
NON-COMBUSTIBLE NONE REQUIRED
iI IMITED-COMBUSTIBI-E 3" UNINSULATED STANDOFF i
1� COMBUSTIBLE 3" INSULATED STANDOFF
HOOD }2
HOODS BUTT TOGETHER
MATH NO GAP BETWEEN
\ MATING CUP CONNECTION
HOOD 01 (SEF DETAIL)
10'-0"
CEILING
co
I
0
0
Q
V
�J
0
x
Lu
z
nF
i a
M
aa�a�
c
0
Ly a a
aiI
ul
N
AD
C 1)
O
�
c` a, OD
FI
�' O
� p c
ID N
it to
Q x 9
Q
F"�
O
N
M
W
U
L I
`i �.11/1:if iti
t �p
" S No d02 A=- 4
I HEREBY CERTIFY THAT THESE PLANS
HAVE BEEN PREPARED UNDER MY
SUPERVISION AND THAT TO THE BEST
OF MY KNOWLEDGE, THE SAME COMPLY
MATH ALL RULES, REGULATIONS AND
ORDINANCES OF CARMEL, IN.
RELATING TO STRUCTURES AND
B A&
VLZ
ARCHITECT
Drawn By
Checked By
Scale
Date
3/4"=1'-0"
3-29-94
Job No.
505-93
Sheet No.
Hi V - I
2
NOTE: IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM
MICROSWITCH TERMINALS SHOWING FACTORY WIRING
MUST BE FIELD WIRED
INPUT POWER I HOOD MAX
3 WIRE, 3 PHASE I LIGHTS 1400 WATTS
VOLTS = 208 TOTAL
BREAKER
AMPS=----- L I F-1
L 7_
000 S1
1 2 3 E31
BI
1000000
EXHAUST EXHAUST
M.P. 1.S M.P. 1.5
OVERLOAD OVERLOAD
AMP. AMP.
III III
IU IU
EXHAUST EXHAUST
FAN 1 FAN 2
'O
in
INPUT POWER 120 'vAC
CIRCUIT
LIGHT CIRCUIT
BREAKER BREAKER
15 AMP 15 AMP
n n
yNCy'I
NO
iC
R1
WHT
S2
SPARE
DRY
CONTACTS
ACTIVATED
BY
MICRYOSWIITCHS
I
?0
ESE USEDCFORHUNT
TRIP DEVICE
CONTROL
NOTE:
DRY
CONTACT RELAY
C -
RED
NO
- DK. BLU
NC
- LT RLU
WIRING FOR 12' X 18" X 6" HINGED
COVERED ELECTRICAL BOX
CAPTIVE—AIRE PREWIRED ELECTRICAL PACKAGE SCHE')ULE
MiCROSWiTCH STATUS WITH
FIRE SYSTEM ARMED
1
ANSUL or YROCNEM ANSUL or YROCHEM
TERMINALS MICROSWITCH MICROSWITCH
C-NO-NC-#2 FOR SHUTDOWN
FOR FEILD --
WIRING TO
BULDING FIRE
PANEL
DRY CONTACTS
FOR SIGNAL BRAS
ONLY
NC 1 BLK UR
NO1 RED @LT I I —
BLK
RED
FACTORY WIRING
— — — — FIELD WIRING
(208V) 2 EXHAUST
1 LIGHT, 1 FAN SWITCH
FANS
PREWIRE
WIRING
DIAGRAM
HOODS
FIRE
PREWIRE
STARTER
SWITCH
# OF
SPECIAL
—
STARTERS
STIR.
TAG
NUMBER
SYSTEM
FAN
FAN
SUPPLIED
CTRL.
VOLT/PH
H.P.
HEATER
CTCRIZ'D
LOCATION
LOCATION
LOCATION
SWITCHES
INSTRUCTIONS
TYPE
TAG
BY
VOLT.
DAMPER
HOOD 4
1 LIGHT
EP #
8201100
1,2,3,4
1
EXHAUST
EF-1
FACTORY
120V
208/3
1.5
N/A
N/A
UTILITY
PREWIRE
I UTILITY
1 FAN
NONE
1
FIRE
CABINET
PACKAGE
CABINET
0 S/W
SYSTEM
RIGHT
0 OTHER
EXHAUST
EF-2
FACTORY
120V
1 208/3
1.5
N/A
N/A
I
i iLr,L n\L 'j i J ILIV1/ t.,vi'I IvL r rniL Lr\ I VV I WNIKUL F'ANLL T2 I MIN AUtN1 TANK tNkLUJtU
ROTISSERIE HOOD V
ATI ON
L
EXHAUST FAN
_
E �r GREASE DRAIN ON FAN
A X A CURB
I
� I �
INSULATION I
� I
EXHAUST DUCT -/
UPBLAST EXHAUST FAN
EXHAUST FAN DIMENSIONAL DATA
MODEL !
H
E
A
B
i_A 188 36
i
1 29
1 25.25
1 24
24
2— REQUIRED
FAN INFORMATION SCHEDULE
Hood
Tag
Fon
Model
Mfg.
CFM
S.P.
RPM
H.P.
PhaseVela
1 & 2
EF-1
EXHAUST
CA18B
CAPTIVE—
AIRE
2100
1.125"
1000
1.5
3
208
3 & 4
EF-2
EXHAUST
CA18B
CAPTIVE—
AIRE
3113
1.125"
1050
1.5
3
208
t�
a
0
pp��
Lu
c/
a
o
0
00
0
co
X
x
W
O
f-
� Q
S
T
fi
aCaad
0
a
all
0
�i
A
C4
a,
�
top
AGOCL
4--
X
=�`L
z
o
Z
to
to
a
Q w
Aah
�
o
N
�y
W
ir}N['rrr'r}���t
6 E R
Nn
T402,
r �t�
I HEREBY CERTIFY THAT THESE PLANS
HAVE BEEN PREPARED UNDER MY
SUPERVISION AND THAT TO THE BEST
OF MY KNOWIDGE, THE SAME COMPL
WITH ALL RULES, REGULATIONS AND
ORDINANCES OF C IN.
RE G TO STRUCTURES AND
ARCH17ECT
Drawn By
Checked By
Scale
Date
1/8"=V-0"
3-29-94
Job No.
5o5®93
Sheet No.
HMI®�
x
0
Z
0
JOB NUMBER 23786
JOB NAME BOSTON CHICKEN
STREET 250 SOUTH STATE ROAD 135
CITY, STATE ZIP ,GREENWOOD. IN.
DRAWN BY SGW
SYSTEM SIZE R-102 18 Flow Point Ansul Wet Chemical System
Hood #1 Size: 126L x 48W x 24H
Duct #1 Size: 13 x 10
Hood #2 Size: 126L x 48W x 24H
Duct #1 Size: 13 x 10
PIPING NOTES
— FIELD PIPE DROPS AS SHOWN
SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS
- MAXIMUM 9 ELBOWS IN SUPPLY LINE.
— MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE.
FACTORY PIPING
FIELD PIPING
18" 18"
14"
18" 18"
14"
O
54.00 -l- 9.00-L 32.00 I- 31.00
O
-0-e
22.00 -�+ 38.00 22.00 31.00 -) 10.00
HOOD # 1
HOOD # 2
0
10 10 10
22.00 -L 38.00 -L 22.00 1 31.00 --� 10.00 '
RQTISSERIE
39 Lx 30"D
RQTISSERIE RQTISSERIE
39 Lx 30 D 39 Lx 30 D
m �0
10 054.00 - I 9.001 32.00 1 31.00
RQTISSERIE RQTISSERIE
39 Lx 30"D 39' Lx 30 D
r uNL ,�rarv_m mi�,r11v—Jrriik,n 1v
SUPPLY FAN SHUT -DOWN RELAY
)N
ANS UL EQUIPMENT LIST - FIRE CABINET MOUNTED
1) 3 GALLON TANK
1 A) 1.5 GALLON TANK
2) A UTOMAN BRACKET
4) R-102 ANSULEX LIQUID AGENT (3- GALLON)
4A) R-102 ANSULEX LIQUID AGENT 0.5 GALLON)
6) DOUBLE TANK CARTRIDGE (DOUBLE -SHORT)
7) TEST LINK
8) MICROS WITCH.• SINGLE- D UAL -;
9) NOZZLE - DUCT TIP #78079-2WH
10) NOZZLE - APPLIANCE TIP #56922-1 W
11) NOZZLE - PLENUM TIP #56926-IN
14) SERIES DETECTORS
16) 360 DEGREE F FUSIBLE LINKS
18) MECHANICAL GAS VALVE
19) REMOTE PULL STATION WITH LABLES AND OCTAGON BOX
,20) LOW TEMP PULLEY ELBOWS FOR DETECTION OUTSIDE HOOD
21) HIGH TEMP COMPRESSION PULLEY ELBOWS FOR DETECTION
0
JOB
BOSTON CHICKEN
LOCA TION
GREENWOOD, IN.
DA TE 2121194
D WG. # BCFIRE01
D WN. BY SG W
CHKD. B Y WEM
REV.
SCALE 314 = 1'0"
AO%
ka~i
_ram
,- -__I Wo _-
w
G=�
co
@
Z
o
ro
@
co)
00 �
0.
a.
MM
0)
W
9t
ns
0
N
Q < < < Q
G ,L 1
v)
r
N
'd
o
c .
•
So
1a.
�. C
�
G*
2ago
U
L •i
a
1n
"o
N
M
W
U
t No. 4022 -
_ C,F -
I HEREBY CERTIFY THAT THESE PLANS
HAVE BEEN PREPARED UNDER MY
SUPERVISION AND THAT TO 1HE BEST
OF MY KNOWLEDGE. THE SAME COMPLY
VATH ALL RULES, REGULATIONS AND
ORDINANCES OF C IN.
RELATING TO STRUCTURES A[�
"On" LAI
ARCHTTWf
Drawn By
Checked . y
Scale
Date
1 /8"=1'-o"
3-29-94
Job No.
505-90
Sheet No.
"MV_3
00
I
j MEDIA BOARD
'i BY OWNER - TYP
�I
i
C F. ROO
110
I
a� 1
TOILE A-13�
11 g /
FILE
AX
FFI
OFFICE
r- - - - - - - - - - - - - -
I I
I I
1
4 A-13 2
3
LOBB
109
- - - F- - - I- I- - - -, - -1 - -
PIN BOARD SUPPLIED
BY OWNER, INSTALLED
BY CONTRACTOR- TYP
13
OFFICE
737r
0 6
5 A-13
PIN BOARD --\ I
FlLE
114 ' OFFICE
I
I 115
I
PLAN TABLE
i PIN BOARD
uu
EQUIPMENT &FIXTURE PLAN
1 /4"=1'-0"
FILE
�5
TYP. -- 2
COAT
a
X
Rom-
\ 'LADDER "0
ROOF HATCH
0)
0
x
v
CV
(50/
TYR. - 3
millilliiME
18x8C MAIN DIST. PANEL
we
WALK-IN
COOLER '29'
7'-9"x17'-4„
r-
104'-0"
�iif
111�y 111111111�
—oil
FREEZER
IIl11111111i�f1•ii11N
,_ •
�.
t 111����"yy�IN
IIII�liiillll 1
TYP. - 2
l t� TYP-2
9X
�50 N
50
WH
'DO
-YP - 2
KITCHEN 5
107
-A 128
�5_0
'1
I �
�j O
�)TYP.-4 N
5"/
A-121
4- 1.
I>
4;
.4-
��',
...J��w/ TyP-z
31''
F- - - - - - - - - - - - - - - - - - - -
i I
5 VESTIBULE
6 A-12 4 101E
3
2 i
I>, 2 \
22A>-
212�>
22B;
00I 2A-12
i 5;
9
'5 9/
X w01
w I II
0' 3' -0" I 1 `2`'I PIPE RAIL l
A-121 ---- ----- FOR CUEING
rt r;4
I -
rvP-z`38' X
—ANSUL. PULL �_' TW O J
STATION O01 O
SPIT /
CAN
° . 5 A 10o I
0 -121
(3, o O 0 TYP-3� Ln F T LINE DININ(
O O G C O
CO
�OOD P EP '
I(13
III" I v2/) ,06
1/1" 6 55 -
TYP-3FI
I
I I I
CICY w
08
�oI Y i l l l x
�N
2 5, H 12lIII o
,---� I -- 1• j l l I I I I (3 , oCIO
� N
1 ,I
_ U
<9 A-12 z
W
xa
JW I I 2B
(n N
a LINE OF
C) I \ i BULKHEADS
ax
01� 50r I c I 0 ABOVE
n
_DK-_—
PICK-UP �01
RECEIPT
HDI PRINTER I100 -
I
I
I
I
I
{
{
I
I
I
I
I
I
I
/ / \ MURAL
/ WOMEN \ 1
I 4A-12
104
FMqr
J�
1
MEN / D
105 �-
A
1
I
I
I I
I
I
I
I
I
L----------------------- ----,
I
I
I
I
I
I � I
I' 1
� I
I
I
I
I
_ I
I
I I
I I
I
1
I
I
I
I
i
0 I
I
I
I
I
I
I
I
I
I
I
I
'----7 (211
14 208) ---J
FUTURE CUSTOMER
FEEDBACK TERMINAL
207
101
PP
7
SIM
8A-12i
7
2'-
4" 01 (FUTURE)
1 ,
FOOD SERVICE
EQUIPMENT
SCHEDULE
NUM.
QTY.
DESCRIPTION
MFG
MODEL
REMARKS
SUPPL. BY
INSTIL. BY
HOOK-UP
NUM.
CITY.
DESCRIPTION
MFG
MODEL REMARKS
SUPPL, BY
INSTIL
1
5
ROTISSERIE
HICKORY
N 7G-ON CASTERS
2RH 3LH
KEC
KEC
PLUMB.
26
-
OPEN NUMBER
-
-
1A
5
QUICK -DISC. HOSE
CONNECT IT
SSGC75-48UCQ
GAS HOSE
KEC
KEC
PLUMB.
27
1
REACH IN REF.
BEV.-AIRE
MT 21 -26 ON CASTERS
KEC
KEC
2
1
SALAD CASE
NAX
1,5M VRM 950RP
OWNER
GC
GC
28
1
FOOD WARMER
APW
W-3V
KEC
KEC
2A
1
CUP HOLDER
CRAFT MFG.
CUSTOM MADE
30"x5"x12"
KEC
KEC
-
29
1
WALK-IN COOLER
KOLPAK
SEE EQ. BK. FOR
KEC
GC
2B
1
PLATE HOLDER
CRAFT MFG.
CUSTOM MADE
22" x 1 1" x 12"
KEC
KEC
-
30
1
FREEZER
KOLPAK
COMP. ACCESS.
KEC
GC
3
1
HOT FOOD CASE
NAX
2.51M RNW 950RP
OWNER
GC
GC
31
1
POTATO CUTTER
WALL MOUNTED
SM. WARES
KEC
3A
1
CUP HOLDER
CRAFT MFG.
CUSTOM MADE
42%5"x12"
KEC
KEC
-
32
1
SPIT TABLE
CRAFT MFG.
CUSTOM MADE
KEC
KEC
38
1
PLATE HOLDER
CRAFT MFG.
CUSTOM-MADE
22" x 1 1" x 12"
KEC
KEC
-
33
1
SPIT RACK
CRAFT MFG.
CUSTOM MADE
KEC
KEC
4
-
OPEN NUMBER
34
2
MOBILE SPIT RACK
HICKORY
CUSTOM MADE
KEC
-
5
1
POST -MIX MACHINE
SITCO
FFC62323.SD5.11
COKE
COKE
-
35
1
DISHWASHER
HOBART
UW-50 W BOOSTER HEATER
KEC
KEC
3
5A
3
CUP DISPENSER
MOD. MFG.
ELC.1002/10.2212
KEC
KEC
-
35A
-
OPEN NUMBER
6
1
BAG -IN -BOX
PROFITMSTR.
BIB-2 PLUS 2
COKE
COKE
ELECT.
356
-
OPEN NUMBER
7
1
BULK CO2
OWNER
-
-
36
1
2 COMP. SINK
ADVANCE
94-42-48
w POLY SINK COV.
KEC
KEC
``
8
1
CUT STATION
CRAFT MFG.
CUSTOM MADE
ON CASTERS
KEC
KEC
-
36A
1
12" FAUCET
T&S BRASS
B231
SWING SPOUT
KEC
KEC
9
1
SANDWICH UNIT
BEV.-AIRE
SUR 48-8C
S.S.BACK/CASTERS
KEC
KEC
-
368
2
LEVER DRAIN
T&S BRASS
B3900
SIZE=2"
KEC
KEC
10
-
OPEN NUMBER
-
-
-
37
-
OPEN NUMBER
-
-
11
1
CONVECTION OVEN
BLODGETT
DFG-52
ON CASTERS
KEC
KEC
PLUMB.
38
1
HAND SINK
ADVANCE
7-PS-50
KEC
KEC
a
11A
1
QUICK -DISC. HOSE
CONNECT IT
SSGC75-48UCQ
GAS HOSE
KEC
KEC
PLUMB.
38A
1
HAND SINK
ADVANCE
7-PS-50
W SIDE SPLASHES
KEC
KEC
12
-
OPEN NUMBER
-
-
-
40
1
HOSE REEL
T&S BRASS
B1403
W B107C
KEC
GC
13
1
SPIT HOLDING CAB.
SECO
CUSTOM
FUTURE USE
-
-
-
41
-
OPEN NUMBER
-
-
14
-
OPEN NUMBER
-
-
-
42
-
OPEN NUMBER
-
-
15
2
STEAMER
CLEVELAND
24-CGM-200
KEC
KEC
PL./ELECT.
43
3
BAKE RACK
EPCO
A-1 1 15
ON CASTERS
KEC
KEC
15A
2
STATIONARY HOSE
CONNECT IT
SBWC25-48UC
WATER HOSE
KEC
KEC
PLUMB.
44
1
BAKE TABLE
CRAFT MFG.
CUSTOM MADE
ON CASTERS
KEC
KEC
158
2
STATIONARY HOSE
CONNECT IT
SSGC75-48UCBVE
GAS HOSE
KEC
KEC
PLUMB.
45
-
OPEN NUMBER
16
-
OPEN NUMBER
46
1
S.S. WORK TABLE
TABCO
KSS304-w RACKS
ON CASTERS
KEC
KEC
17
2
GAS KET. w/STAND
GROEN
TDH/40-SP/TS-8
(12) GAL. KETTLE
KEC
KEC
PL./ELECT.
47
2
POLYTOP WK. TBL.
TABCO
SPT304
ON CASTERS
KEC
KEC
17A
2
STATIONARY HOSE
CONNECT IT
SSGC50-48UCBVE
GAS HOSE
KEC
KEC
PLUMB.
48
-
OPEN NUMBER
-
-
178
4
STATIONARY HOSE
CONNECT IT
SBWC25-48UC
WATER HOSE
KEC
KEC
PLUMB.
49
-
OPEN NUMBER
-
-
18
1
MIXER
HOBART
L800-2A,2HP
KEC
KEC
ELECT.
50
11
FLOOR SHELVING
ISS
GOLD BOND
KEC
KEC
g
19
1
HOLDING CABINET
ALTO-SHAAM
1000-UP/P
ON CASTERS
KEC
KEC
ELECT.
51
7
CLR. FRZ. SHLV.
ISS
GOLD BOND
KEC
KEC
20
1
ICE MACHINE
HOSHIZAKI
KM630MAB/630OPC
KEC
KEC
PL./ELECT.
52
2
DELIVERY SHELVING
ISS
GOLD BOND
w SOLID SHELF
KEC
KEC
21
1
FOOD PROCESSOR
HOBART
FP-100-1
KEC
KEC
-
53
-
OPEN NUMBER
-
-
22
1
COFFEE MAKER
BUNN
M-90
KEC
KEC
PLUMB.
54
5
DISP. WALL SHLV.
MILLWORK
WOOD SHELVES
10"d X 1 1 2"w
MILLWORK
GC
22A
1
ICED TEA BREWER
CECILWARE
FTC-3
KEC
KEC
ELECT.
55
12
UTILITY WALL SHLV.
ISS
ZINC/GOLD BOND
SEE EQ. MANUAL
KEC
KEC
226
1
LEMONADE
MERCO
BD775-C T
RED SHD/WHT.CRD.
KEC
GC
ELECT.
56
-
OPEN NUMBER
-
-
22C
-
OPEN NUMBER
57
-
OPEN NUMBER
-
-
23
1
HOLDING CABINET
ALTO-SHAAM
500-S STD
KEC
KEC
ELECT.
58
2
UTENSIL RACK
AMCO
-
24'x18"x3"
SM. WARES
KEC
24
3
WARMER LAMPS
MERCO
BD775-C T
RED SHD/WHT.CRD.
KEC
GC
ELECT.
59
15
CORNER GUARDS
CRAFT MFG.
CUSTOM MADE
2" x2" x 1 14"
KEC
I KEC
25
1
HEAT LAMPS
HATCO
GRAIHL-54D
INFRA BLACK
KEC
KEC
ELECT.
60
2
EXHAUST HOOD
HOOD MFG.
-
SEE MFG. DWGS.
OWNER
GC
-- - - - - - - - - - - - - - - -I- - - - - - - - - - - - - -
- - - - - - - - - - - - -
- - - -
10-7-93
OMPUTER
U I P M E N T 10-
0TE
EFRIGERATOR CONTRACTOR IS
RESPONSIBLE FOR PROVIDING THE SALAD
CASE COMPRESSOR & ITS INSTALLATION
ON THE ROOF. THE REFRIGERATION
CONTRACTOR IS TO INSTALL ALL
COMPRESSORS & EVAPORATERS COOLER
FOR THE WALK IN COOLER & FREEZER.
HOOK-UP
NUM
QTY
DESCRIPTION
FG
MODEL
REMARKS
SUPPL. BY
INSTL. BY
-
100
4
POINT -OF -SALES
MICROS
000184-018
-
MICROS
GE COMP.
-
113
1
MANAGER'S OFFICE
IBM
6384F20
-
COMARK
GE COMP.
-
127
1
CUSTOMER SURVEY
IBM
6384FOO
-
COMARK
GE COMP.
ELECT./
HTG. REFG.
133
3
P.O.S. DELIVERY
MICROS
000184-018
-
MICROS
GE COMP.
*NOTE: SEE SHT, BC-3 FOR COMPLETE SCHEDULE & RELATED ACCESSORIES*
GENERAL FURNITURE & FIXTURES
NOTE:
E: THE FOLLOWING ARE OWNER
PROVIDED ITEMS (UNLESS INDICATED
OTHERWISE IN GENERAL CONTRACT).
NUM
TY
DESCRIPTION
MFG
MODEL & SIZE
REMARKS
SUPPL. BY
INSTL. BY
01
1
P7S. COUNTERG&L
MILLWORK
141 Lx x 6 H
W/DESERT A
O MILLWK
71
PLUMB.
201 a
1
COUNTER
G&L MILLWORK
36" Lx30" Dx36" H
SEE MILLWORK DWGS.
MILLWORK
GC
201b
2
COUNTER
G&L MILLWORK
30"Lx22"Dx36"H
SEE MILLWORK DWGS.
MILLWORK
GC
-SOUND SYSTEM
-SECURITY SYSTEM
-PHONE SYSTEM
-FIRE EXTINGUISHERS (PER LOCAL
CODE)-INST. BY GC
-MENU BOARDS-INST. BY GC
-WALL MURAL-INST. BY GC
-AWNINGS: ELECT. CONNECT. BY GC
-SIGNAGE (INCL. ALL LOGOS, EXTERIOR
& INTERIOR SIGNAGE
201 c
1
COUNTER
G&L MILLWORK
68" Lx29" Dx36" H
SEE MILLWORK DWGS.
MILLWORK
GC
PLUMB.
202
1
BACK COUNTER
G&L MILLWORK
120"I.x25"d.x36"h.
SEE MILLWORK DWGS.
MILLWORK
GC
PLUMB.
203
42
DINING CHAIR
JASPER
1200
BLACK ANALINE
OWNER
GC
PLUMB.
204
5
4-SEAT TABLE TOP
G&L MILLWORK
SQUARE TOP
SEE MILLWORK DWGS.
MILLWORK
GC
-
204A
5
TABLE BASE
FALCON
700-27 30"
BLACK WRINKLE TRIPOD
OWNER
GC
PLUMB.
205
15
2-SEAT TABLE TOP
G&L MILLWORK
30"x24" x 1 1 2"
SEE MILLWORK DWGS.
MILLWORK
GC
PLUMB.
205A
15
TABLE BASE
FALCON
700-27/30"
BLACK WRINKLE TRIPOD
OWNER
GC
PLUMB.
206
-
DINING LEDGE TOP
G&L MILLWORK
1 20"x24" x 1 1 /2"
SEE MILLWORK DWGS.
MILLWORK
GC
-
207
1
DBL. TRASH UNIT
G&L MILLWORK
48" x24"
SEE MILLWORK DWGS.
MILLWORK
GC
-
207a
1
SNGL. TRASH UNIT
G&L MILLWORK
24" x24"
SEE MILLWORK DWGS.
MILLWORK
GC
-
208
1
CUST. FEEDBACK
G&L MILLWORK
18" x25"
SEE MILLWORK DWGS.
MILLWORK
GC
-
209
-
DINING STOOLS
JASPER
1400
BACKLESS -BLACK ANALINE
OWNER
GC
-
210
4
DINING BENCH
FALCON
76'x24"x36 1 2"
W109-LIGHT CHERRY W/
ALCON BILK WRINKLE BAS
OWNER
GC
-
211
2
DINING BENCH
FALCON
48" x24" x36 1 2"
OWNER
GC
-
212
1
SELF SERVE CNTR
G&L MILLWORK
103" x48" x36 1 2"
SEE MILLWORK DWGS
MILLWORK
GC
-
213
1
COUNTER
G&L MILLWORK
103Lx48Dx36H
SEE MILLWORK DWGS.
MILLWORK
GC
-
*NOTE: SEE SHT. A-14 FOR COMPL*
ADMINISTRATIVE EQUIPMENT
=
_
NUM
QTY
DESCRIPTION
MFG
MODEL
REMARKS
SUPPL. BY
INSTL. BY
_
407
1
SAFE
CORP. SAFE SPCL.
BR2018E
-
OWNER
GC
_
408
1
MANAGER'S DESK
G&L MILLWORK
-
SEE MILLWORK DWGS.
MILLWORK
GC
_
409
1
STOOL
-
-
-
OWNER
-
_
410
1
FILE CABINET
-
UARCO
I 4-DRAWER UNIT
OWNER
-
_
412
2
WALL CABINETS
G&L MILLWORK
I SEE MILLWORK DWGS.
MILLWORK
GC
_
*NOTE: SEE SHT. BC-3 FOR COMPLETE SCHEDULES*
C ORI * KEC=KITCHEN EQUIPMENT SUPPLIER
-
Z
a
X
LL
a
i
Z
W
�
a
0
W
o
m
CL
a
� �-
<g
ink+
t
v
I
I
~
I
M
I
a a a
V)
C
0
QZ1
o
N
o
= c,
A
C -Un
S�
o
y
1G
'� C
q �;=g
r ri N
z $ Im
U
Q w
AC^
a
N
M
W
U
1 HEREBY CERTIFY THAT THESE PLANS
HAVE BEEN PREPARED WIDER MY
SUPERVISION AND THAT TO THE BEST
OF MY KNOWLEDGE, THE SAME COMPLY
WITH ALL RULES, REGULATIONS AND
ORDINANCES OF CARMEL,INDIANA
RELATING TO STRUCTURES AND
BUILDINGS
ARCHITECT
Drawn
By
Checked By
S.L.
Scale
Date
1 /4"=1'-0"
1
2-4-94
Job No.
505-93
Sheet
No.
A-1
�I V A 0 SYSTEM SECTION 15500
THE WORK INCLUDES modification to the existing HVAC
system and providing new ductwork, diffusers and grilles,
insulation, controls and equipment necessary for a complete
functioning system. HVAC system includes but is not
necessarily limited to the following:
. Providing heating, ventilation, and air-conditioning (HVAC)
units.
+ Supply & return ductwork system with grilles, diffusers,
filters, and dampers
+ Temperature control system including low -voltage wiring
and conduit
* Duct, piping, and equipment insulation, where indicated
herein
* Roof curbs, roofing and flashing of roof penetrations for
equipment noted
• Controls and wiring for connection to Landlords fire/smoke
EQUIPMENT indicated on the Drawings or as required for a
complete installation, such as rooftop units, make up air units,
ductwork, exhaust fans, supply and return diffusers, etc., shall
be provided within the Scope of Work of this Section. Refer to
drawings of kitchen hoods, hood exhaust and supply fans for
extent of owner furnished items. Equipment shall be installed
so that they are accessible for inspection and service.
WA o o at , air or p a e
defective parts and materials as required for on or after
substantial completion or owner acceptance of the completed
project. Provide a separate line -item deduct amount on the
Proposal Form to delete warranty service, at the Owner's option.
DRAWINGS for HVAC Work are diagrammatic, showing the
general location, type, layout and equipment required. The
Drawings shall not be scaled for exact measurements. Refer to
manufacturers standard installation drawings for equipment
connections and installation requirements as required. Fumish
and install and ductwork, connections, accessories, offsets, and
materials necessary to facilitate the system's functioning as
indicated by the design and the equipment indicated. The Work
shall be in accordance with local codes or ordinances and
subject to inspection.
COORDINATE with the Work of other Sections, equipment
furnished by others, requirements of the Landlord, and with the
constraints of the existing conditions of the Project Site.
EXTRA STOCK: Provide two sets of replacement filters per
each installed for all the rooftop units, and other equipment and
devices, and provide a itemized list of the number, type
required and where used. Obtain receipt form owner that these
items have been delivered and accepted by the Owner's
representative.
ROOFTOP EQUIPMENT shall be furnished with integral
insulated mounting curb(s), to comply with requirements of the
roofing system and all accessories indicated in the rooftop unit
schedule. Provide units to meet or exceed the capacities
indicated.
DUCT DIMENSIONS: Unless otherwise noted, duct dimensions
on drawings are net inside clear dimensions on lined ducts or
sheet metal dimensions on unlined ducts.
SHEET METAL DUCTWORK: Sheet metal fabricated and
installed to ASHRAE and SMACNA standards. Sheet metal
shall be galvanized sheet steel of lock -forming quality, ASTM
A-525. Unless otherwise noted, duct dimensions on drawings
are net inside clear dimensions on lined ducts, or sheet metal
dimensions on unlined ducts. All angle iron used for support
shall be galvanized. Connections to walls or floors shall be
airtight with angle iron and caulking. Seal all duct seams,
transverse and longitudinal, air -tight. Provide turning vanes at
all elbows or offsets exceeding 33 degrees. Line all supply,
return, and make-up air with 1 /2" 3 lbs. density duct liner having
a K factor of 0.23 075 F. Provide ASTM C916 liner adhesive
and fasteners per SMACNA.
TRAPEZE DUCT HANGERS: minimum 1" x 2" x 1" x 18 gage
channels with 1" x 18 gage straps to structural support above.
COMBUSTION EXHAUST SYSTEM: Provide all draft hoods,
vent connectors, listed cops and type "B" flues necessary to
vent the products of combustion from gas appliances shown on
the plan. Comply with NFPA-54 for size and installation
requirements, and local codes having jurisdiction.
DUCT WRAP/ASJ INSULATION (on all supply, return, make up
and round rigid sheetmetal ductwork): Provide 2" thick
fiberglass ASJ ductwrap with vapor seal on all snap -lock and
spiral sheetmetal above inaccessible ceiling. Conform to
Federal Spec. HH - I - 5588 (amend. 3): Type 75: form B,
type 1, class B-2.
RiGID ROUND GALVANIZED DUCT: Shall be spiral or snaplock
galvanized sheetmetal complying w/SMACNA.
FLEX DUCT: Provide factory assembled class 1 air duct (UL
181) with 1" thick 1 PCF fiberglass insulation and reinforced
outer protective cover / vapor barrier. Flex duct shall meet
NFPA 90A with flame spread under 25, smoke developed under
50, and shall be rated for 2" w.g. pressure and 0 to 250 degree
temperature. Provide metal adjustable clamping devices, screw
operated. Use t.wistlock conical tap collars at connections into
sheet metal ductwork. Do not exceed 8 feet in length for any
flex duct. Refer to details for additional requirements.
Cl ry ill l!`T
rL
)RN AIR GRILLE
NOTE: REFER TO PLANS FOR DUCT SIZES
02 RETURN AIR TRANSFEIR DU cT DETAIL
NOT TO SCALE
9
z:
ROUND BALANCING DAMPERS: Fabricated of some material as
duct, two metal �ouges heavier than duct
mounted on 3/8 square rod with saw slot position indicator.
Pivot bearing, locking position regulator, Young Regulator Co., series
443. Regulator shall be positioned with sheetmetal bracket beyond
duct covering.
FLEXIBLE CONNECTOR: Where indicated provide U.L. labeled 30 oz
neoprene coated fiberglass fabric duct connectors.
KITCHEN HOOD EXHAUST DUCTWORK: Provide 16 gouge black iron
ductwork. All joints and seams shall be welded liquid tight.
All elbows shall be radius and the duct system shall be
fabricated so as to have no dips, traps or pockets where grease
can accumulate. Provide approved access panels for inspection
and cleaning at all changes in direction, and to gain access to
the bypass damper and fusible link where applicable. Insulate exterior
of duct with insulation approved by local authority to provide for 3"
clearance for duct enclosure. Provide fire rated access panels
in the duct enclosure at all duct access panel locations.
CEILING DIFFUSERS / RETURNS: Provide supply diffusers
and damper in sizes, capacities, materials, and pattern
indicated on the Drawings.
ACCESS PANELS: Provide hinged access panels in ductwork
where required for access to equipment. Provide insulated
access doors in insulated ductwork.
AUTOMATIC TEMPERATURE CONTROL: Provide for each
HVAC unit a unit controller with remote sensor input. Controllers
shall incorporate multiple stages of heat/cool as applicable with an
auto changeover feature and have a setbakc module. Heating and
cooling setpoints shall be operator adjustable. Contollers will be
provided input from a single time clock through a setback/setup
module. This time clock shall have a 48 hour battery backup, two
on and two off schedules per day , have seven day programming
capability, and LCD or LED readout of day and time The night
I for r setback setu module o after hours usage is for overridef h
/ P
o to
9
controllers normal setpoint temperature. Locate the controllers,
control transformers, realys and time clocks as applicable in the
office in a ventilated locking cabinet. Space temperatures shall he
set for cooling at 73'F normal and 857 setup temperature, and
heating at 71'F normal and 65T setback temperature
Provide relays as required for hood interface. Whenever the hood
is switched on, the fans on the HVAC units, make up air unit and
kitchen exhaust fans shall start and the HVAC unit and make up air
unit outdoor air dampers shall open to provide the minimum CFM
of outdoor air specified. The space temperature shall continue to
control heating and cooling while operating under this mode.
Relays shall be provided to activate the fans of all units. When the
hood switch is off, the fans will return to automatic operation.
The make up air unit shall have a duct mounted sensor for input to
its internal controls. This shall be set to maintain duct supply
temperature at no less than 65F. The make up air unit shall
operate whenever the hood is switched on and stop whenever the
hood is switched off
The toilet exhaust fan shall be wired directly to a circuit breaker and
shall operate ontinuously.
Provide where applicable, duct mounted supply and/or return air
photoelectric type UL listed smoke detectors. Detectors shall be
listed for the air velocities encountered. Provide interlock wiring to
to provide for unit fan shut down. On activation of any detector all
HVAC unit fans shall stop.
Provide interlock wiring as required with Ansul Hood Fire
Suppression System to shut down both the supply and exhaust
fans that serve the hoods. Provide fan shut down relays for both
the supply fan and exhaust fans in series with the hood switch.
Wiring shall be in conduit from a point of connection indicated on
the kitchen hood drawings. Wiring shall comply with Section
16400 requirements.
The mechanical contrcctor shall provide a schematic diagram of
the controls and submittals of the control components for approval.
ROOF PENETRATIONS shall comply with SMACNA and NRCA
standards.
TEST AND ADJUST each piece of equipment and each system
as required to assure proper balance and operation, follow
NEBB and ASHRAE standards. Eliminate noise and vibration,
and assure proper function of all controls, maintenance of
temperature, and operation. Balance mechanical system, and
submit completed test report to Construction Manager, prior to
request for final payment. Balancing contractor shall be an
independent contractor from HVAC installing contractor. Ali
systems shall be balanced to within 5% of air volumes indicated.
Any discrepancy shall be reported for duct correction prior to
final report, to HVAC installer. After final duct adjustments have
been made. final balancing shall be performed and the results
reported in a certified balance report. Note all air quanities
outside of tolerance in report.
VENT (4 SIDES).
FLASH & COUNTER FLASH
16 Go. WELDED STEEL EXHAUST
DUCT. PROVIDE CLEANOUTS PER
LOCAL CODE REQUIREMENTS.-
5/8" TYPE 'X' GYPSUM BOARD.
BOTH SIDES ON 3-5/8" METAL
STUDS AT 12" O.C., U.L. 465. —
FIRE CAULK ALL PENETRATIONS
WITH U.L. APPROVED CAULK.
A
I
---STAINLESS STEEL ENCLOSURE PANEL
U.L. CLASSIFIED
FURNISH WITH HOOD,
BAFFLE TYPE j 8 ---U.L. CLASSIFIED VAPOR
GREASE FILTER PROOF LIGHT
8 TYPE 1 EXHAUST HOOD FURNISHED
3" AIR SPACE
MIN. AND INSTALLED BY MECHANICAL
CONTRACTOR.
DUCTBOARD BOOT i j
(22"x22" OR 22"X10") GREASE FIRE EXTINGUISHING HEAD PER NFPA 96
\ REQUIREMENTS. SEE DRAWING M2 FOR ANSUL
TROUGH R102 SYSTEM DETAILS. (REFER TO ARCHITECTURAL
— DRAWINGS FOR REQUIREMENTS).
6 6" ALL SLIDES
- COOKING EQUIPMENT (BY OTHERS)
Ir
I
�- FLOOR
WALL
NOTE: REFER TO ARCHITECTURAL DRAWING
FOR ADDITIONAL DETAILS AND SECTION.
®1 TYF'E 1 KITCHEN EX('QUST H000 DETAL
NOT TO SCALE -
ROOFTOP UNIT SCHEDULE
MARK EXTERNAL COOLING HEATING (GAS) ELECTRICAL. MINIMUM
MANUFACTURER MODEL NO. CFM STATIC BLOWER EAT0. A. REMARKS
RT IN WG H,P. TOTAL BTUH SENSIBLE BTUH DB S ATMB. BTUH INPUT BTUH OUTPUT VOLT/f�/HZ MCA CFM
1
AAON
Kt- 1,)
5L00
0.00
5.0
149,000
108,000
80/67
105
228,000
184,680
208/3/60
75
1100
6 ROW EVAPORATOR
2
AAON
RE-13
5200
0.60"
5.0
149,000
108,000
80/67
105
228,000
184,690
208/3/60
75
200
6 ROW EVAPORATOR
3
AAON
RE-07
2800
0.60"
3.0
93,800
70,600
80/67
105
142,500
115,430
208/3/60
50
200
6 ROW EVAPORATOR
4
AAON
RE-07
2800
0.60"
1 3.G
89,600
69,000
80/67
105
'42,5DO
115,430
208/3/60
50
200
FURNISH AND INSTALL ALL REFRIGERATION SAFETY & RELIEF, DEVICES do LINES AS REQUIRED.
NOTES: 1) PROVIDE ROOFTOP UNITS W/ NEW OUTDOOR AIR ECONOMIZER, BAROMETRIC RELIEF DAMPER, & TiME DELAY ON COMPRESSOR RESTART.
2) PROVIDE THERMOSTAT WITH CLEAR LOCKING GAURD. REFER TO TEMPERATURE CONTROL SPECIFICATION.
3 SET MINIMUM FRESH AIR AS SPECIFIED ABOVE.
4) REFERENCE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
5) FURNISH AND INSTALL A 14' HiGH ROOF CURB FOR ALL NEW UNITS.
6) FURNISH AND INSTALL A UNIT MOUNTED DISCONNECT SWITCH FOR ALL NEW UNITS.
7) FURNISH AND INSTALL FACTORY MOUNTED RETURN AIR AND SUPPLY AIR SMOKE DETECTORS ON ALL NEW UNITS, PRE WIRED AND INTERLOCKED.
8) FOLLOW MANUFACTURERS INSTRUCTIONS FOR STARTUP AND INSTALLATION.
SCCiHEDULE OF MFFUSEiRS AND REGISTERS
V
DESIGNATION
MANUFACTURER
MODEL NO
TYPE
NECK SIZE
FACE SIZE
FRAME TYPE
NC MAX
FACTORY FINISH
REMARKS
A
E.H.PRICE
AMD/613
LOUVERED
15"X15"
24"X24"
LAY -IN
< 30
OFF-WHITE BAKED ENAMEL
B
E.H.PRICE
AMD/813
LOUVERED
18_X18
24 X24
- IN
< 30
OFF-WHITE
� ITE BAKED ENAMEL
C
E.H.PRICE
SCD/SPL
LOUVERED
15"X15"
24"X24"
_LAY_
LAY -IN
< 30
GLIDDEN #22YY 45/114
D
E.H.PRICE
RCD/B13
ROUND SUPPLY
PER PLAN
SURFACE
< 30
OFF-WHITE BAKED ENAMEL
E
E.H.PRICE
AMD/813
LOUVERED
6"X6"
18"X18"
SURFACE
< 30
OFF-WHITE BAKED ENAMEL
F
E.H.PRICE
TBD4100/B13
T-BAR SUPPLY
PER PLAN
4-SLOT
SURFACE
< 30
OFF-WHITE BAKED ENAMEL
VERTICAL DISCHARGE
G
E.H.PRICE
96L/B13
LOUVERED RETURN
22"X22"
24"X24"
LAY -IN
< 30
OFF-WHITE' BAKED ENAMEL
H
E.H.PRICE
96L/SPL
LOUVERED RETURN
22"X22"
24"X24"
LAY -IN
< 30
GLIDDEN il22YY 45/114
J
E.H.PRICE
96L/B13
LOUVERED RETURN
22"X10"
24"X12"
LAY -IN
< 30
' OFF -WHIM BAKED ENAMEL
SEE DETAIL 02
NOTES: 1. REFER TO DRAWINGS FOR FURTHER INSTALLATION AND APPLICATION DETAILS
2. FURNISH AND INSTALL A SQUARE TO ROUND FOR ALL GRILLES.
3. OTHER APPORVED MANUFACTURERS ARE: TITUS, KREUGER, METALAIRE. ALTERNATE MANUFACTURERS MUST MATCH MATERIALS, TYPE,
AND PERFORMANCE OF LISTED DEVICE.
4. PROVIDE INSULATED PLENUM ON ALL SLOT DIFFUSERS.
VENTILd�TI®N
SCHEDULE
_
OUTSIDE AIR
SUPPLY AIR RETURN AIR
EXHAUST AIR
MU-1
4170
4170
--
--
RT-1
1100
5200
4000
RT- 2
200
5200
5000
- -
RT-3
200
2800
2500
RT-4
200
2800
2500
KEF-1
--
--
--
2100
KEF-2
- -
--
--
3113
EF-1
- -
--
--
360
EF-2
--
--
--
95
[TOTALS
5870
20170
14000
5668
EXrHAUST FAN SCHEDULE
EXTERNAL ELECTRICAL
MARK MANUFACTURER MODEL NO. CFM S.P. RPM SONES FAN TYPE ACCESSORIES
IN. W.G. VOLT/O/HZ HP
EF-1 GREENHECK GB-80-4 360 0.375" 1350 7.8 115/1/60 1/4 ROOF BD,SC,BS,DS
EF-2 GREENHECK GB-70-4 95 1 0.375 990 3.5 115/1 /60 1/4 I ROOF BD,SC,BS,DS
ACCESSORIES: BS-BIRD SCREEN, BD--BACKDRAFT DAMPER, SC -PREFABRICATED INSULATED ROOF CURB,
DS-DISCONNECT SWITCH
NOTES: 1) FURNISH ALL MOUNTING BRACKETS, DOWNRODS AND ETC FOR A COMPLETE INSTALLATION.
2) REFER TO ELECRICAL DRAWINGS FOR WIRING.
3) ALTERNATE MANUFACTURERS ARE COOK, PENN, ACME, SUBJECT TO PERFORMANCE.
KITC'r---'UEN MAKE—UP AIR AND EXHAUST PACKAGE
EXTERNAL HEATING (GAS) ELECTRICAL
MARK MANUFACTURER MODE[_ NO: CFM STATIC FAN EXHAUST FAN DRIVE REMARKS
NO. iN WG RPM HP CAPACITY VOLT/e/HZ TYPE TYPE
INPUT BTUH
MU-1 GREENHECK KSU-112-B-2-30 4180 1.25" 1050 3.0 400,000 208/3/60 --- -- NOTE 2
KEF-i CAPTIVE AIRE CA188 2100 1.25' 1000 1.5 -- - 208/3/60 UP -BLAST BELT FURNISHED BY OTHERS
UP -BLAST TYPE DISCHARGE SHALL BE KEF-2 CAPTIVE AIRE CA188 3113 1.25" 1050 1.5 --- 208/3/60 UP -BLAST BELT FURNISHED BY OTHERS
40" MINIMUM TO FAN DISCHARGE FROM
ROOF, PROVIDE CURB HEIGHT NOTES: 1) KITCHEN EXHAUST FANS ARE FURNISHED BY OTHERS AND INSTALLED BY MECHANICAL CONTRACTOR. DATA SHOWN FOR CLARITY, REFER TO CAPTIVE AIRE
DRAWINGS FOR ADDITIONAL INFORMATION
ACCORDINGLY
2) PROVIDE ADDITIONAL MOTOR STARTERS & RELAYS FOR INTERLOCK TO KEF-1 & KEF-2. FOLLOW MANUFACTURERS INSTRUCTIONS FOR STARTUP AND
INSTALLATION.
ROOF
3" MINIMUM CLE E T HASH
_ 24"X10" RADIUSED ACCESS PANEL IN HEEL
OF RADIUSED ELBOW. 16 GA. STEEL. WELD
1/4" STUDS 0 6"O.C. TO DUCTWORK AT ACCESS
PANEL AND SECURE ACCESS PANCL TO DU,T,��ORK CONNECTION OF FLEX DUCT
,< INSULATION COVERING RIGID ROUND
WITH 1/4" WING NUTS. PROVIDE 24"X24" 1 1 /2HR U.L. RIGID METAL DUCT SUPPORT WITH METAL STRAPPING, DO NOT KINK
LISTED ACCESS DOOR IN CHASE AT DUCT ACCESS ROUND BALANCING DAMPER REF. SPECS.
DOOR, EQUAL TO RUSKIN APW1. Q INSULATED SUPPLY DUCT
Pill IAI
BALANCING HANDLE
LOCK INTO POSITION INSULATED FLEXIBLE DUCT
AND MARK PERMANENTLY
DIFFUSER STARTER COLLAR
CEILING
SQUARE TO ROUND
ADAPTER
LAY -IN DIFFUSER
NOTES:
1. PROVIDE AT FLEXIBLE DUCT CONNECTION METAL OR "PANDUIT" DRAWBAND
ON THE INTERIOR FLEXIBLE DUCT HELIX. SECURE THE INSULATION OVER
THE DRAW BAND WITH AN ADDITIONAL DRAWBAND.
2. PROVIDE BEADING ON ROUND METAL DUCT 12" OR LARGER iN DIAMETER.
3. PROVIDE MINIMUM 2" COLLARS FOR ATTACHMENT OF THE FLEX DUCT TO
ROUND DUCT, DAMPERS AND DIFFUSERS.
4. BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION OVERLAP.
O3 FILEMBLE DUCT WSTALLATION DETAIL
LARSON • BINKLEY ASSOCIATES, INC.
CONSULTING A ENGINBERS
8900 STATE LINE ROAD 111150
LEAWOOD, KANSAS 66206
(913) 383-2621
C0
p
W
L1
N
woo
�!1
A
�
iU
Co
Q
n
V
U3
J
a
V)
6
wv
(r a)
N W p
0 C] rry
0 0
� UM
ay,1
0
N
A
o u)
cy,
�4
C: i
OD �D
° 3§m
=
0
«► ILLZ v
-0146
Q « t>C
o ►�
Q
H
�
0
N
x
U
i HEREBY CERTIFY THAT THESE PLANS
HAVE BEEN PREPARED UNDER MY
SUPERVISION AND THAT TO THE BEST
OF MY KNOWLEDGE, THE SAME COMPLY
NTH ALL RULES, REGULATIONS AND
ORDINANCES OF CARMEL.iNDiANA
RELATING TO STRUCTURES ANC
BUILDINGS
ARCHITECT
Drawn By
Checked By
DBC
WAS
Scale
Date
1/4"=1'-O"
01-24-94
Job No.
50%:p-93
Sheet No.
L � w�