HomeMy WebLinkAboutS100.0EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
EXISTING
2668 DNWALL FLOOR
T
FLOOR JOIST DIRECTION
DW
WO
GFCI
CT
R
R4
R4
R4 R4 GD GD GFCI
13'-2 3/4" 11'-6"11'-2"KITCHEN
7'11" C.H. AFF
HARDWOOD
DINING
7'11" C.H. AFF
HARDWOOD
D2D2
D2D2
D3D3
D4D4
D5D5
D6D6
E2E2
E3E3
E4E4
E5E5
P2P2
H2H2
H3H3
E4E4
DEMO & PREP PLAN NOTES
NOTE QTY DESCRIPTION
1 HOMEOWNERS TO SUPPLY FURNITURE AND WINDOW
COVERING REMOVAL PRIOR TO START OF DEMOLITION.
2 INSTALL PLASTIC ZIPPER WALL ON ALL DOORWAYS IN
CONSTRUCTION AREA.
1 DEMO EXISTING INTERIOR WALL AS SHOWN.
1
REMOVE ALL EXISTING APPLIANCES FOLLOWING
DISCONNECTS. SAVING DISHWASHER AND REFRIGERATOR
FOR REUSE.
1 REMOVE EXISTING CABINETS, PLUMBING FIXTURES,
COUNTERTOPS, AND BULKHEADS. (TRASH)
1 DEMO EXISTING WINDOWS AT SINK. (TRASH)
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
D1D1
D2D2
D3D3
D4D4
D5D5
D6D6
PLUMBING DEMO/DISCONNECT PLAN NOTES
NOTE QTY DESCRIPTION
1 SEPARATE PLUMBING PERMIT NOT REQUIRED.
1
DISCONNECT PLUMBING LINES TO SINK, DISHWASHER, AND
REFRIGERATOR PRIOR TO DEMOLITION. STUB LINES IN
FLOOR. SINK AND DISHWASHER STAYS IN SAME LOCATION
ON NEW PLAN.
P1P1
P2P2
P1P1
P2P2
ELECTRICAL DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE ELECTRICAL PERMIT NOT REQUIRED.
1 DISCONNECT ALL APPLIANCES.
1 DISCONNECT AND REMOVE RECESSED CANS IN BULKHEAD.
2 DISCONNECT AND REMOVE CEILING MOUNTED LIGHT
FIXTURES.
1 EXISTING ELECTRICAL IN WALLS TO BE DELETED PRIOR
TO WALL DEMOLITION.
E1E1
E2E2
E3E3
E4E4
E5E5
E1E1
E2E2
E3E3
E4E4
E5E5
GENERAL NOTES
NOTE QTY DESCRIPTION
1
HOME OWNERS TO CLEAR OUT A SECTION OF GARAGE
FOR STORAGE OF BUILDING MATERIALS DURING THE TIME
OF CONSTRUCTION.
1 DUMPSTER AND PORTALET LOCATION TO BE IN DRIVE WAY.
VERIFY WITH CLIENT.
GN1GN1
GN2GN2
GN1GN1
GN2GN2
HVAC DEMO/DISCONNECT NOTES
NOTE QTY DESCRIPTION
1 SEPARATE HVAC PERMIT IS NOT REQUIRED.
1
DEMO EXISTING DOWNDRAFT AND CAP EXISTING VENT
PENETRATION. PREP AREA FOR NEW VENT HOOD SYSTEM
PER PLAN.
1 DEMO EXISTING WALL VENT, NEW LOCATION TO BE
DETERMINED ON SITE WITH HVAC PROFESSIONAL.
H1H1
H2H2
H3H3
H1H1
H2H2
H3H3 PIRRO RESIDENCEKitchen Remodel3737 Coventry WayCarmel, IN 46033Date:Revision:
A2
SHEET OF 7
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462208/31/2021
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL SITE PREP & DEMO NOTES
Install plastic to seal off areas being remodeled
from rest of home as necessary.
Install floor covering for construction path from
door designated as the construction entrance to
locations of remodeling as necessary.
Install additional floor covering or wall protection
as needed over areas close to the areas of
construction activity.
Install dust control measures on HVAC cold air
returns located within the locations of
remodeling.
Custom Living can provide a HEPA Air Scrubber
to aid in airborne dust control from the start of
demolition up to priming of new drywall
depending on site conditions. Homeowner
understands that this will help to reduce airborne
dust; however, it will not mitigate it in its entirety.
Demolition Contractor(s) are responsible for all
labor, for the scope of work specified in the
drawings provided by Custom Living.
Homeowner understands that Custom Living has
only provided a labor and material allowance for
the scope of demolition denoted on the
drawings. Any additional scope added or
uncovered during demolition result in filing a
Change Order during construction.
Homeowners understand that demolition work
will generate dust and noise throughout the
house. Custom Living will provide site protection
measures to reduce where possible, but
Homeowners should not expect 100%
containment.DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073EXISTING / DEMO PLAN
SCALE: 1/2" = 1'N
09/07/21