Loading...
HomeMy WebLinkAboutS100.11'-4" 7'-8 5/8"HEADER (WINDOWS & DOORS): DOUBLE 2X8 DOUBLE TOP PLATE KING STUD CRIPPLE STUD BOTTOM PLATE O.C. 3/4" SUBFLOOR 2x8 CEILING JOISTS 2X10" LVL FLOOR JOISTS @ 16" O.C. EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 4DB33SB3624DW B18R 1DB24B18L B18L SB30 B241 3DB24 B253B241 2DB24B2721 4DB33SB36 24DW B18R 1DB24B18L B18L SB30 B241 3DB24 B253B241 2DB24B2721 U392492 U392492 U242792LU242792R W2436 W362124 W1836R W2436 W1836L W01 EXISTING 40682668EXISTINGDN T cL G DW GFCI R4 R4 R4 R4 R4 R4 R4 R4 R4R4 R4 R4 R4 R4 GFCI R GFCI GFCI R H OGFCI GFCI GFCI M T L LGD L 25'-2" 10'-4 1/2" 2'-11" 11'-10 1/2"11'-0 1/2" 25'-4 3/4" 6'-10 1/2" F1F1 KITCHEN 7'11" C.H. AFF HARDWOOD D1D1 D2D2 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME FOR NEW WINDOW, PATCH AND REPAIR EXTERIOR TRIM AS NECESSARY.F1F1F1F1 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET MUNICIPAL FIRE CODE REQUIREMENTS. FINAL INSULATION SCOPE TO BE DETERMINED ON A FIELD WALK FOLLOWING MECHANICAL ROUGH-INS. I1I1I1I1 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 PATCH AND REPAIR CEILING AND WALL DRYWALL AS NEEDED BY DEMO 1 PATCH AND REPAIR DRYWALL AS NEEDED FROM CABINET REMOVAL. D1D1 D2D2 D1D1 D2D2 WINDOW SCHEDULE NUMBER FLOOR QTY R/O BOTTOM TOP WIDTH HEIGHT EGRESS TEMPERED DESCRIPTION SUPPLIER W01 1 1 55"X37" 44" 80" 54 " 36 " SINGLE AWNING FRANKLIN PIRRO RESIDENCEKitchen Remodel3737 Coventry WayCarmel, IN 46033Date:Revision: A3 SHEET OF 7 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462208/31/2021 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Orde r during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. PROPOSED FLOOR PLAN SCALE: 1/2" = 1' TYPICAL FRAMING DETAIL SCALE: 3/8" = 1' 0" DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073N 09/07/21