HomeMy WebLinkAboutA5 Electrical Locations - RevisedWP
R
4
GFCI
3 WP
SD
EP
DC
SD
DM
A
T
AV Control
C5/TV C5 TV
T
SP SP
DESCRIPTIONSYMBOL
ELECTRICAL - DATA - AUDIO LEGEND
Ceiling Fan
Ventilation Fans: Ceiling Mounted, Wall Mounted
Ceiling Mounted Light Fixtures: Surface/Pendant,
Recessed, Heat Lamp, Low Voltage
Wall Mounted Light Fixtures: Flush Mounted,
Wall Sconce
Chandelier Light Fixture
240V Receptacle
110V Receptacles: Duplex, Weather Proof, GFCI
Switches: Single Pole, Weather Proof, 3-Way, 4-Way
Switches: Dimmer, Timer
Audio Video: Control Panel, Switch
Wall Jacks: CAT5, CAT5 + TV, TV/Cable
Telephone Jack
Intercom
Thermostat
Door Chime, Door Bell Button
Smoke Detectors: Ceiling Mounted, Wall Mounted
Electrical Breaker Panel
Speakers: Ceiling Mounted, Wall Mounted
Fluorescent Light Fixture
SP
SP SP
SP
UP
S /
WS / W S / W S / W S / W S / W S / W S / W S / W
R
R
R
3
GFCI
R
R
R
3
C5
C5
RR
R
R RR
RR
SD
L L L
SD
L
R
R R
R R
R
R
R
DM
DMDM
R
3'2'-7" 10'-10"9'-8"
7'-5"
3'-6" 11'-6" 2'-0 1/4"3'-9" 3'-9" 3'-9" 3'-9" 5'-7 1/4"3'-3" 3'-2 1/2"
4'-2"4'-4 1/2"4'-4 1/2" 3'-6" 3'-6"4'-9 3/4"UTILITY
CLOSET
BATH
LIVING
Elevate Outlet 66" AFF
Ceiling Projector
Ceiling Outlet
##
1. ) Existing Light Fixture
2. ) Ceiling Projector location to be
field verified by owner. Projector to
be installed by owner. Blocking to
be installed. Projector to be
mounted 13' from screen wall.
3. ) Elevated outlet for TV to be field
verified by owner.
4. ) All speakers and data wiring to
be by owner. Contractor to cut
accesses.
5. ) Exhaust fan / light unit to be
vented to exterior.
6. ) Existing smoke detector.
7. ) Low Voltage Blanks Client to
verify in field.
8. ) Install new CO/Smoke Detector.
9. ) Install battery backup.
Note: All smoke and CO detectors
to be brought up to state mandated
IN2020 residential code throughout
structure by completion of project.
11 11
22
33
44 44
44
44
44
55
66
77
88
77
99 REVISIONSCLIENT DATE SITE MANAGER INITIALSSHEET:
SCALE:DRAWINGS PROVIDED BY:DATE:
9/7/2021BasementMr. & Mrs. Falk12948 Cantigny WayEastCarmel, IN 46033IA-5
1/2" = 1'-0"Custom Home Medic1093 3rd Ave South WestCarmel, IN46032Electrical Plan (Location Only)
ELECTRICAL, DATA, & AUDIO NOTES:
HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS
TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES,
CABLE, DATA, PHONE, AUDIO, ETC.
ELECTRICAL NOTES:
1. ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND
GARAGES SHALL BE G.F.I. ORG.F.I.C. PER NATIONAL ELECTRICAL
CODE REQUIREMENTS.
2. PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH
CORRIDOR ACCESSING BEDROOMS. SMOKE DETECTORS TO BE
BATTERY OPERATED.
3. CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE
INSTALLATION.
4. FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED
WITH HOME OWNER.
5. FIXTURES TO BE SELECTED BY HOME OWNER.
AUDIO:
1. LOCATE SPEAKERS AND AUDIO CONTROLS AS INDICATED IN THE
PLAN; RUN CIRCUIT OF SPEAKER WIRING TO AUDIO HOME PANEL
SPECIFIED BY FLOOR; IF APPLICABLE.
2. AUDIO SPEAKERS TO BE APPROVED BY HOME OWNER;
3. LOCATE JACKS AS INDICATED IN THE PLAN; INSTALL DATA / CABLE
PANEL SIMILAR TO "ON Q". SYSTEM TO BE APPROVED BY HOME
OWNER.
DATA / CABLE:
LOCATE SECURITY PANELS AS INDICATED IN THE PLAN; SYSTEM TO
BE APPROVED BY HOME OWNER.
09/08/21