Loading...
HomeMy WebLinkAboutGN010.0 - HAM 38 - FULL SETFRONT & REAR ELEVATIONS scale 1/4"+1'-0" GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design1 TOP OF MAIN LEVEL CONCRETE SLAB 10'-0"19'-038"BRICK BRICK ROWLOCK BRICK ROWLOCK BRICK SOLDIER BOT OF WIN. HDR. BOT OF WIN. HDR. METAL FLASHING SLOPE TOWARDS INTERIOR (VERIFY w/ CONTRACTOR) METAL CAP SCUPPER w/ DOWNSPOUT PARAPET WALL w/SCUPPER D/S METAL FLASHING SLOPE TOWARDS INTERIOR (VERIFY w/ CONTRACTOR) BRICK ROWLOCK BRICK ROWLOCK HARDI PANEL w/ 1x2 TRIM GATE INSET 8" FROM EDGE OR BRICK TO CENTER OF WALL 9'-6" 3"7'-7"8'-0"STONE CAP BRICK 4'-4"4'-0"Roof to be minimum of 12" below window BRICK SOLDIER 08.16.2021Hamlet Lot 38TOP OF GARAGE LEVEL CONCRETE SLAB BRICK BRICK ROWLOCK LAP SIDING METAL CAP HARDI PANEL w/ TRIM METAL FLASHING SLOPE TOWARDS INTERIOR (VERIFY w/ CONTRACTOR) 12 PITCH4 (5" EXPOSURE)9'-118"10'-118" 9'-118" 7'-63 8"8'-0"4'-4"4'-0"BRICK Kislyuk-Rosenthal Townhouse09/09/21 LEFT & RIGHT SIDE ELEVATIONS SCALE: 1/4" = 1'-0"GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design2TOP OF GARAGE LEVEL CONCRETE SLAB8'-0"TOP OF SECOND LEVEL SUB FLOOR TOP OF MAIN LEVEL CONCRETE SLAB 10'-0"BRICK BRICK BRICK BRICK ROWLOCK BRICK ROWLOCK BRICK SOLDIER BRICK SOLDIER BOT OF WIN. HDR. BOT OF WIN. HDR. HARDI PANEL w/ TRIM 12 PITCH 4 HARDI PANEL w/ 1x2 TRIM HARDI PANEL w/ 1x2 TRIM 10'-0"12 PITCH 4 TOP OF GARAGE LEVEL CONCRETE SLAB TOP OF SECOND LEVEL SUB FLOOR TOP OF MAIN LEVEL CONCRETE SLABTOP OF GARAGE LEVEL CONCRETE SLAB TOP OF MAIN LEVEL CONCRETE SLAB9'-0"BRICK BRICK ROWLOCK BRICK BRICK ROWLOCK BRICK ROWLOCK BRICK SOLDIER BOT OF WIN. HDR. HARDI PANEL w/ TRIM 12 PITCH4 PARAPET WALL w/SCUPPER D/S METAL FLASHING SLOPE TOWARDS INTERIOR (VERIFY w/ CONTRACTOR)7'-0"9'-0"HARDI PANEL w/ 1x2 TRIM Hamlet Lot 38Kislyuk-Rosenthal Townhouse8'-0"7'-8"08.16.2021 09/09/21 GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignUNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL 912" POURED CONCRETE9 1/2" POURED CONCRETE 712" POURED CONCRETESINK W D UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL SCALE: 1/4"=1'-0" FOUNDATION PLAN 3 12"x18" ANCHOR BOLTS 48" O.C. AIR SPACE BRICK VENEER FD5 FOUNDATION DETAIL 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI R-10 RIGID INSULATION 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"x18" ANCHOR BOLTS 48" O.C. HOUSE SLABHOUSE SLAB GARAGE SLAB TOP OF MAIN LEVEL SUB FLOOR 12" EDGE FD1 FOUNDATION DETAIL FD2 FOUNDATION DETAIL FD3 FOUNDATION DETAIL FD4 FOUNDATION DETAIL GASCOOKTOPw/HOODABOVEDW. REF. CONDUIT. 7 1/2" POURED CONCRETE 7 1/2" POURED CONCRETE 7 1/2" POURED CONCRETE 7 1/2" POURED CONCRETE7 1/2" POURED CONCRETE 1'-912"16'-3"1'-1112 "20'-0"13'-11" 712"33'-11"84'-7" 12'-0" 1'-111 2"8'-3"1'-912" 96'-7" 24'-3" 712" 15'-114"1'-4"20'-7316"1'-2"17'-8916 "4'-5" 1'-8" 1'-2" 712" 712"1'-112"2'-1"2'-8"7'-2" 2'-8"12'-6"2'-0" 1'-112"3'-10"71 2"1'-2" 7'-2"1112" 1'-112"7"2'-1" 1'-112" 9'-312"21'-5"8" 34'-7"33'-11"7'-8"1'-812"4'-4"1'-712"1'-712"8" 1'-4" 7'-2" 6'-11" 7'-2" 20'-9" 52'-7" 712"712"712" 7'-412"6'-0"7'-412" 21'-3" 3'-8"3'-8"94'-7" 17'-4"1'-4" 1'-712"4'-4"1'-712"1"7'-8"16'-10"712"18'-3"1'-4" 15'-612" DOOR OPG.DOOR OPG.7'-912"3'-0" 10'-3"19'-5" 4'-10"12'-1012"21'-012"R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION THICKENED SLABTHICKENED SLAB R-10 RIGID INSULATION THICKENED EDGETHICKENED EDGE 42"x42"x12" THK. CONC. FOOTING 1'-012" 8'-514"20'-912" 512" 17'-10"DOOR OPG.WET BAR RGH-IN Hamlet Lot 38W.H. WATER SOFTNER BYPASS ONLY H.B.Kislyuk-Rosenthal Townhouse24"x24"x12" THK. CONC. FOOTING 42"x42"x12" THK. CONC. FOOTINGTHICKENED SLABTHICKENED SLAB 7'-314 "13'-6"08.16.2021 09/09/21 12'-6"19'-812"20'-212" 21'-31 4"24'-10"2'-0"3'-7" 6'-9" 6'-9" 4'-4" 2'-1" 7'-9" 2'-1"11'-11"21'-5" 33'-4"3'-10" 3'-4" 6'-4" 3'-10" 10'-8" 10'-8"6'-412" 7'-2" 7'-2" 20'-8" 21'-4" 52'-0" 94'-0"3'-8"8" 3'-8"22'-103 4" 31'-0" 2'-4" 17'-33 4" 26'-41 4" 84'-0"1'-712"16'-0"2'-412"13'-4" 12'-0" 12'-0"20'-0"33'-4"27'-10"19'-712" 6'-3"6'-812"6'-812"1'-012"8'-214"10'-5"4'-1112" 5'-512"61 2"61 2"3'-4"61 2"7"1112"1112"4'-5" 2'-111 2" 4'-612"512" 4'-2"GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignFirst Floor Plan CONSTRUCTION LEGEND 3 CAR GARAGE: 685 SQ. FT. MAIN LEVEL: 1930 SQ. FT. MAIN LEVEL SECOND LEVEL 937 SQ. FT.SECOND LEVEL: 72 SQ. FT.STORAGE: KITCHEN 2 CAR GARAGE COURTYARD 16'0"x7'0" OVERHEAD DOORENTRY/ FOYER 3060 HDR @ 96"HDR @ 120" 4020 HDR @ 120" 40204060HDR @ 120"40204060HDR @ 120"40204060HDR @ 120"4020ROOF TOP 482 SQ. FT.SUN RM/STOR: PANTRY CUSTOM TRANSOM2-3'0"x8'0" 792 SQ. FT.TERRACE DECKING: LIVING AREA - OPEN TO ABOVE - WOOD FLOOR - CROWN 16'0"x7'0" OVERHEAD DOOR2" MINIMUM SLOPED CONCRETE SLAB TRU 42" F.P. GAS KEY GAS - WOOD FLOOR - CROWN UP 20 EQUAL RISERS w/ 11" WOOD TREADS HANDRAIL - 10'0" CEILING HEIGHT - WOOD FLOOR - CROWN12'6"x8'0"C.O.4 H.B. 2'6 " x8' 0 " 10'-412" 2'6"x8'0" CLOSET GAS COOKTOPw/HOOD ABOVEHDR @ 108" 2640 HDR @ 108" 2640 2x 3/0x8/0 FRENCH DOORS DW. REF. 2026 FIXED 2026 FIXED 2026 FIXED 5'-0" EDGE OF CONNECTED HOUSE4'-4"7'-7"4'-4"8" 17'-5"1'-4"1'-4" 74'-0"3'-912" 3'-912" 22'-834" 3060 4'-4" 6'-4" 6'-4" 4'-4" 5'-7" 9'-8"4'-134" 3'-812" 512"5'-83 4 " 15'-43 4" 5'-101 2"19'-334"2'-4" 2'-4"2'-4" HDR @ 108" 4'-812"312"17'-5"Hamlet Lot 382" MINIMUM SLOPEDCONCRETE SLAB8'0"x7'0" OVERHEAD DOORHVAC2'6"x8'0"3RD CAR GARAGE 16'-212"12'-8"3'0 "x8'0" 8'-2"4'-0"3'-1012"12'-1"12'-1" 3060 HDR @ 96" 3060 TUB/SHOWERCH 3'0"x8'0" 8'-7" W. D. 2026 FIXED 2026 FIXED 2026 FIXED HDR @ 108"UTIL.SINK20'-5"6'-012" CH LAUNDRY - 10'0" CEILING HEIGHT - TILE FLOOR 3'0"x8' 0 " GUEST BATH CLOSET CLOSET CLOSET BEDROOM #2 - 10'0" CEILING HEIGHT - CARPET FLOOR BEDROOM #3 - 10'0" CEILING HEIGHT - CARPET FLOOR HALL BATHRM #2 - TILE FLOOR - 10'0" CLG HGT - WOOD FLOOR 4'-93 4" 4'-93 4"8'-1" - 10'0" CLG HGT - CARPET FLOOR - 10'0" CLG HGT - CARPET FLOOR 3'-7"2'8 "x8 '0"2'8"x8'0"2'6"x8'0" PCKT. DR. - 10'0" CLG HGT - WOOD FLOOR - 10'0" CLG HGT - WOOD FLOOR - 10'0" CLG HGT - WOOD FLOOR LNDRY CHUTE WET BAR RGH-IN SMOOTH CEILINGS EXCEPT GARAGE 3 '0 "x8'0 "3'0"x8'0"11'-1112"2'-1012"8'-1" 4'-4" 3'-1"7'-1"9'-3"14'-1112"11'-1112" 51 2" 1'-012" 11'-012" 3'-9" 3'6"x8'0" D.W.O. W.H. WATER SOFTNER BYPASS ONLY 714" 8'-1"6'-812"6'-1"1'-0"3'-2"7'-1012"3'-1034" 5'-614"3'-1012"DBLE. WALL BACK WALL FOR CLOSET CHUTE ENDS AT CLG. OF LNDRY RM. CABINET w/DROP-IN SINK (ROD & SHELF ABOVE)TILED WALLSVENT TO EXTERIOR ZONED HVAC Kislyuk-Rosenthal TownhouseMain T-Ast 1'-8"CSMT CSMT CSMT CSMT DROPPED STEEL BEAM TOP OF BEAM at 9'-11 58" 2 STORY STEEL COLUMN 1 STORY STEEL COLUMN 2 STORY STEEL COLUMN 08.16.2021 09/09/21 18'-0916 "3'-105 16" 12'-11516" 3'-105 16" 20'-8" 21'-4" 16'-67 16 " 34'-212" 60'-1"4"3'-412"17'-414"3'-8"3'-0" 15'-4" 3'-0" 2'-4" 2'-4" 2'-4" 2'-4"3'-8"6'-9"8'-11" 8'-11"12'-0916" 4'-10"GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignHVAC LIVING AREA 3056 2026 FIXED MEDIA/LOFT 2026 FIXED 2026 FIXED 2026 FIXED 2026 FIXED 3' 0" x 6 ' 8 " Second Floor Plan - OPEN TO BELOW FURNACE - 9'0" CEILING HEIGHT - CARPET FLOOR -(1) FLOOR OUTLET STOR. UNDER STAIRS 5 3056 30563056 3056 2-3056DOWN 20 EQUAL RISERS w/ 11" TREADS HANDRAIL WOOD HANDRAIL DN UP 20 EQUAL RISERS w/ 11" TREADS WOOD UP 6'-1"4'-10" 11'-71 16" 11'-1" 6'-11" 512"6'-8"11"20'-1112"4'-014" 11"6"4'-4" MASTER BEDROOM - 9'0" CEILING HEIGHT - CARPET FLOORL. L.SHOWERGLASS2'6"x8 '0" 3' 0 "x8' 0"3'-10" 3'0 "x8'0 " WALK-IN CLOSET - 9'0" CEILING HEIGHT - CARPET FLOOR 15'-3"16'-1"4'-9"6'-012" MASTER BATHROOM - 9'0" CEILING HEIGHT - TILE FLOOR 3'0"x8'0" PKT. DR.8'-912"15'-3"6'-1012"3060 CSMNT HDR. @ 96" 3056HDR. @ 92"3056 HDR. @ 92" 306016'-1"3020 TRANSOM3'0"x8'0" PKT. DR.Hamlet Lot 38- 9'0" CEILING HEIGHT - LVP FLR'G -SOUND INSULATE WALLS LNDRY CHUTE TO 1ST FLR 5'-1112"5'-1112" 11'-11"33'-4"4'-4"6'-9" 6'-9" 3'-7" 21'-5" 33'-4"10'-012"2'-212" SMOOTH CEILINGS EXCEPT GARAGE ZONED HVACRAILINGCHUTE BUILT 42" 0FF FLR. w/HINGED TOP HDR. @ 96"C.H.HDR. @ 96"30603060 HDR. @ 96"Kislyuk-Rosenthal Townhouse3010 TRANSOMHDR. @ 96"4'-712"10'-314"2026 FIXED 7'-117 16"CURB4'-012" VALVE CSMT CSMT DROPPED STEEL BEAM TOP OF BEAM at 21'-1 3 4" SADDLE WELDED TO COLUMN TO ACCEPT 3 PLY 11 7 8" LVL 2 STORY STEEL COLUMN 2 STORY STEEL COLUMN 4'-101 2"7'-5"3'-91 2"6'-214"8'-012"8'-012" 6020HDR. @ 96"08.16.2021 09/09/21 H.B.GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignSUN RM/TERRACE FLR PLAN scale 1/4"+1'-0" 6 STORAGE PWDR. RM. C.H. SUN ROOM DN WET BAR R.I. ONLY 4'0" TALL SHIP LAP WALL 4'0" TALL SHIP LAP WALL ROOF SLOPE ROOF SLOPE TREX TYPE DECKING 41'-51 2" 4'0" TALL SHIP LAP WALL TREX TYPE DECKING 20'-1012"UNACCESSIBLE SPACE Hamlet Lot 3812'-212"16'-1" 28'-312"4'-1112"6'-11"12'-21 2" 15'-634"12'-934"28'-412"4'-312"21'-3" 6'-1"5'-2"9' CLG.LVP FLR'G 9' CLG. WOOD FLR. 9' CLG. WOOD FLR. OPEN RAIL 4'-012" 9'-012"28'-458"15'-5" 8'-012" 8'-012" 16'-1"10'-9" 15'-3" 7'-4"33'-4"6'-1" 19'-73 8"3'-712"21'-10" SMOOTH CEILINGS EXCEPT GARAGE WOOD 2ND GAS FURNACE GAS LINE TO ROOFTOP Kislyuk-Rosenthal TownhouseGAS LINEEXTENSION FOR FIRE PIT LOCATION -TBD CSMT FIXED CSMTFIXEDFRAMED AND TRIMMED HALF COLUMN 08.16.2021 09/09/21 GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignKITCHEN 2 CAR GARAGE COURTYARD ENTRY/ FOYER PANTRY LIVING AREA 2" MINIMUM SLOPED CONCRETE SLAB TRU 42" F.P. GASGAS KEY UP HANDRAIL ALL LIVING ROOM OUTLETS - IN BASEBOARD H.B. H.B. CLOSET GASCOOKTOPw/HOODABOVEDW. REF. EDGE OF CONNECTED HOUSE4'-4"4'-4"Hamlet Lot 382" MINIMUM SLOPEDCONCRETE SLABHVAC3RD CAR GARAGE TUB/ SHOWER CH W. D.UTIL.SINKCH LAUNDRY GUEST BATH CLOSET CLOSET CLOSET BEDROOM #2 BEDROOM #3 HALL BATHRM #2 LNDRY CHUTEWET BAR RGH-IN SMOOTH CEILINGS FLUSH HEARTH SPEAKER 7Preliminary 1st Floor Electrical Plan W.H. WATER SOFTNER BYPASS ONLY Kislyuk-Rosenthal Townhouse 08.16.2021 09/09/21 8 PRELIMINARY SECOND FLOOR ELECTRICAL SCALE: 1/4"=1'-0" GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance DesignHVAC LIVING AREA MEDIA/LOFT - OPEN TO BELOW STOR. UNDER STAIRS SMOOTH CEILINGS HANDRAIL HANDRAIL DN UP MASTER BEDROOML. L.SHOWERWALK-IN CLOSET MASTER BATHROOM Hamlet Lot 38LNDRY CHUTE TO 1ST FLR FLOOR OUTLET LOCATION T.B.D. SPEAKER Kislyuk-Rosenthal TownhouseGLASSCURBVALVE FURNACE 08.16.2021 09/09/21 GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design6 STORAGE PWDR. RM. C.H. SUN ROOM DN WET BAR R.I. ONLY 4'0" TALL SHIP LAP WALL 4'0" TALL SHIP LAP WALL ZONED HVAC ROOF SLOPE ROOF SLOPE TREX TYPE DECKING 4'0" TALL SHIP LAP WALL TREX TYPE DECKING (792 SF) UNACCESSIBLE SPACE Hamlet Lot 38PRELIMINARY SUN RM/TERRACE ELECTRICAL SCALE: 1/4"=1'-0" SPEAKER SMOOTH CEILINGS 2ND GAS FURNACE GAS LINE TO ROOFTOP Kislyuk-Rosenthal TownhouseH.B. 08.16.2021 09/09/21 GARY NANCE DESIGNArchitectural Concepts ByMake yourself at home4631 Lisborn Drive Carmel, IN 46033317.663.4793 Pgnance@garynancedesign.com garynancedesign.comThese design concepts are the property of Gary Nance Designand may not be used without approval from Gary Nance Design10ROOF PLAN SCALE: 1/4" = 1'-0" 3. GENERAL NOTES * 10'0" CEILING HEIGHT UNLESS OTHERWISE NOTED * POCKET DOORS: TRIPLE 2x12 HDR. W/ 12" PLYWD. GUSSETS 2 PLY SOLID BLK'G. BOTH SIDES (TYP.) * INTERIOR DIMENSIONS TO FACE OF STUD WALLS * EXTERIOR DIMENSIONS TO FACE OF SHEATHING * VERIFY WINDOWS w/ OWNER/CONTRACTOR. ANDERSEN WINDOWS SHOWN, VERIFY WINDOW NUMBERS AND SIZING WITH WINDOW MANUFACTURER AFTER THIS IS COMPLETE, PLEASE PROVIDE H.G. McCULLOUGH DESIGNERS WITH A WINDOW LIST * CROWN MOULDING ALL OF FIRST FLOOR EXCEPT CLOSETS * MAIN LEVEL FLOOR JOIST SYSTEM 60 LBS. P.S.F. TOTAL FLOOR LOAD * PROVIDE SOLID BLK'G. BETWEEN FLOORS UNDER ALL BEARING WALLS AND COLUMNS ABOVE * ALL WALLS ALIGNED WITH FLOOR JOIST DIRECTION TO HAVE FLOOR JOIST BELOW THEM * FLOOR JOIST MANUFACTURERS ARE TO SUPPLY H.G. McCULLOUGH DESIGNERS WITH ALL NECESSARY FLOOR FRAMING PLANS, INCLUDING MAIN LEVEL, SECOND LEVEL AND ROOF PLAN. H.G. McCULLOUGH DESIGNERS IS TO BE NOTIFIED DURING THE FLOOR FRAMING DESIGN PROCESS IF IT DEVIATES FROM THE ORIGINAL PLAN, AND REVIEW THE CHANGES WITH ONE ANOTHER. * VERIFY FLOOR JOIST/STRUCTURAL BEAM PLACEMENT WITH PLUMBING LOCATIONS. IF THERE IS AN ISSUE PLEASE CONTACT MCKENZIE HOMES 2X10 BLOCKING FLUSH W/ INSIDE FACE OF STUDS 8" SCALE: 1/2"=1'-0" 4. WINDOW/DOOR HEAD FRAMING DETAIL (TYP.)6"LVL HEADER (VERIFY SIZING w/ LUMBER MANUFACTURER)Hamlet Lot 384'0" TALL SHIP LAP WALL 4'0" TALL SHIP LAP WALL ROOF SLOPE ROOF SLOPE TREX TYPE DECKING 4'0" TALL SHIP LAP WALL TREX TYPE DECKING UNACCESSIBLE SPACE RIDGE RIDGEVALLEY 4:12 PITCH HIPHIPHIPHIP4:12 PITCH4:12PITCH4:12PITCH4:12PITCH4:12PITCHSUN ROOM FLAT ROOF SLOPE SLOPE Kislyuk-Rosenthal Townhouse08.16.2021 09/09/21