Loading...
HomeMy WebLinkAboutC201 SITE PLANST TR ST ST HY DW 757 .6757 .7 HOPEWELL PKWY. (LOCAL, 2-LANE, 46' R/W) INST. # 2008043635 E. 146th ST. (PRIMARY ARTERIAL, 5-LANE, VARIABLE R/W) S85°17'03"E 172.80'S00°00'00"E 245.82'S90°00'00"W 172.21' MW 7'LANDSCAPE ESMT INST. # 2008043644N00°00'00"E 260.02'FALCON NEST II, LLC INST. # 2011063056 PROPOSED 1.00 ACRES 15' UTILITY ESMT INST. # 2008033173 DON RIGO PROPERTIES, LLC INST.# 2017002435 ASPHALT PATH [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO] [FO][FO] [FO] [FO] [FO] [FO] [FO] 30' STORM ESMT INST. # 2008043638 30' STORM ESMT INST. # 2008043638 ////////// / /////// / / / ////// //// / / //////// / / //////// ////// / / // / / / /////// / / / ////// //// / / / / ////// / / / / / //// / / ////// / / //////// / // / ////// / /// // PROPOSED VETERINARY CLINIC 1-STORY 5,600 SF ± GAS METER CT UD UD UD UD UDUDU D U D UD UD UD UD UD DO NOT ENTERAC AC AC AC AC 20'25' 20' 11 SPACES @ 9' = 99' 5 SPACES @ 9' = 45' 4 SPACES @ 9' = 36' 8' 8' 8.49' 23'9' 14.28' 5' 21' 16.19' 25'21.57' 5.31' 5' 6.7' 12' 5' R5'R1 0 ' R3'R3'R3'R3'R3'R8'R15' R26' R8 'R3'R15'R30' R 5 'R3'R3' R 5 'R5' R 5 ' R5'R3 0 'R30'41.03'15.19'5'23'9' R3'R3'27.5'± 21' 9.35' 25' 74.6'± 72.1'±23.44' 60.5'±54.1'± PROPOSED 40.5' INGRESS/EGRESS & UTILITY ESMT. 13' 13' A A A B BB A C D D E E G H H H I I G G G J LL L L L L M N S L F1 F1 F3 F1 F1 F2 A1 K K L L S K F3 REMOVE 89.1' EX. CURB FOR NEW DRIVE. SAWCUT EX. PAVEMENT FOR CLEAN EDGE. PATCH ASPHALT, AS NECESSARY. R 12'120.7'±122.8'±14.54' P 6'6.38' 5.12'3.92'5'5'5' 5.13' J I2 I2 R5' G A 13' 27.5' YELLOW DOG VETERINARY CLINIC PROJECT NO. CHECK: DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com ashton@Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: COOLER DESIGN, INC. 9135 NORTH MERIDIAN ST. STE A1 INDIANAPOLIS, INDIANA 46260 1/13/2021 2004002 7325 E. 146TH ST. CARMEL, INDIANA 46033 HAMILTON COUNTY NE 1 4 , S23, T18N, R4E SHEET NAME SHEET NO. C201 SITE PLAN ISSUED FOR SDR 4/1/2021 2.REV. PER REVIEW CMMTS 4/20/2021 3.REV. DROPOFF DRIVE 5/5/2021 4.REV. PER REVIEW CMMTS 5/28/2021 AF AF AF AF AF AF KG 00 20' 40' SCALE: 1" = 20' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. KEY NOTES: A1 RIGHT OF WAY PAVEMENT (PER CARMEL DETAIL 10-22) A LIGHT DUTY ASPHALT PAVEMENT B HEAVY DUTY ASPHALT PAVEMENT C CONCRETE PAVEMENT D COMBINED CONCRETE CURB & WALK E CONCRETE WALK F1 6" CONCRETE CURB F2 VALLEY CURB & GUTTER F3 CONCRETE CURB & GUTTER G ADA RAMP (PER INDOT DETAIL) H 4" WHITE PAVEMENT STRIPING, TYP. I ADA BLUE PAVEMENT STRIPING, TYP. I2 ADA PARKING SIGN (REF. DETAIL) J PAVEMENT MARKING (AS SHOWN) K MATCH EXISTING PAVEMENT, CURB, OR WALK L LANDSCAPE AREA M DUMPSTER ENCLOSURE (REF. ARCH. PLAN) N EXISTING SIDEWALK/PAVEMENT TO REMAIN O SIDEWALK TRANSITION AT DRIVE (PER INDOT DETAIL) P BICYCLE PARKING (U-SHAPED, BLACK THERMOPLASTIC POWDER COATED) Q FLUSH CURB / CURB TAPER R MONUMENT SIGN (REF. SIGNAGE PLANS) S FENCE/SCREEN WALL (REF. ARCHITECTURAL PLANS) NOTES: XXALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. CARMEL ENGINEERING DEPT. NOTE BOTH DRIVEWAY ENTRANCE OFF OF REDD RD. WILL REQUIRE SAW CUTS PER CITY OF CARMEL STANDARDS. ALL CURB CUTS MUST BE SAW CUT TO THE NEAREST JOINT PAST THE REQUIRED LIMITS OF THE CURB REMOVAL. DRIVEWAY ENTRANCE SAW CUT NOTE ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 18 " OF VERTICAL SEPARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 2 3 22 09/07/21