HomeMy WebLinkAboutM100.0 MechanicalJadam Property Group, LLCBuilding Expansion4511 W 99TH STREETCarmel, Indiana 46032IN+Design, llc 9425 N. Meridian St #214 Indianapolis, Indiana 46250 Ph: 317-549-5600 PRECEPT, LLC 8801 River Crossing Blvd Indianapolis, Indiana 46240 Ph: 317-843-5959 Suite 300 Review Set 7062 N. TUXEDO STREETINDIANAPOLIS, IN 46220PH: 317-508-4516 FAX: 317-820-3405e-mail: morwalsoplad1@gmail.comJACK P. MORGANAIA CSI - ARCHITECTMECHANICAL PLANM1.102/07/21 MECHANICAL PLAN - BUILDING VIEW SCALE: 1/8" = 1'-0" MECHANICAL PLAN - OFFICE VIEW SCALE: 1/4" = 1'-0" sagging of lines. Pitch auxiliary drain pans and cooling coils slightly in direction of condensate flow. drain. Slope to positive drain with straps at 48" o.c. to avoid coil. Provide 3/4" condensate drain separated from cooling coil requirements of all units with the Electrical Contractor to Ductwork shall be insulated. See Ductwork General Notes. with slope to positive drainage outside of building. Provide sheet The Mechanical Contractor to provide 3/4" PVC condensate drains All Exhaust Fans and Ventilators shall have back draft dampers. metal auxiliary drain pan, at attic units, 2" deep under each cooling assure final correct locations of the unit's disconnects. Units provided and installed by the Mechanical Contractor, power and wiring by the Electrical Contractor. All equipment to be provided with internal fuse protection, per N.E.C., State and local Codes. Mechanical equipment shall be base bid as 3Ø power supply. power supply prior to ordering and installing equipment. control devices and Low Voltage Wiring. Thermostats to be Mechanical contractor shall be responsible for verifying available The Mechanical Contractor to provide and install specified Fresh / Outside Air shall conform to ASHRAE 62 "Ventilation for Acceptable Indoor Air Quality" and all State and Local Codes. D.O.E. Test procedure and A.R.I. Standard 210-79. S.E.E.R. / E.E.R. - as rated in accordance with U.S. Government A.F.U.E. - Annual Fuel Utilization Efficiency as established by U.S. Government Standard D.O.E. Test. to final occupancy. The Mechanical Contractor shall provide Balancing Report prior lock for all thermostats. Fully Programmable 7 Day. Provide "tamperproof" Covers with The Mechanical Contractor shall coordinate all electrical The Mechanical Contractor shall be responsible for pouring The Mechanical Contractor is to coordinate gas piping with The heating, air conditioning equipment and installation shall The Mechanical Contractor shall coordinate supply air and may be installed at the proper locations, as not to affect the conform to all current National, State and Local Codes. of the units, and piping servicing the units. Piping in attic, to be structural system of the building. served using 1" stencil or engraved plastic. concrete pad for units. Units to be 30" clear of building or Plumbing Contractor to assure correct size and final locations The Mechanical Contractor to clearly label each unit by area return air ducts with General Contractor so duct encasements suspended from trusses a minimum of 12" above insulation for proper leak test and future service and inspection. The M.C. at manufacturer's recommendations, which ever is greater. to verify all aspects of gas service with local utility. The Mechanical Contractor shall install fire dampers in all ducts passing through Fire Rated Walls and Ceilings (denoted as "F.D." on these Drawings) and all other locations specified by the State Fire Marshall or Authority Having Jurisdiction. These drawings indicate duct for size and approximate location. Ducts may need to be moved slightly to insure no obstruction in installation. to unit. faced insulation. acoustical lining. of insulation. - OR - finished areas shall be painted flat black. SMACNA Duct Manual and NFPA 90-A. Coordinate all duct penetrations with Structural Drawings. exhaust grilles, ductwork, etc. with lighting layout, reflected ceiling plan Coordinate exact locations of all ceiling diffusers, registers and Supply and return ducts shall be sheet metal with 1" thick internal Wrap all supply and return ductwork with 2" thick, 3/4 lb. density foil Flexible ductwork not to exceed 6'. When longer runs occur, use 28 Ga. All ductwork shall be fabricated and installed in accordance with OR SPECIFICATIONS. Duct dimensions are shown as clear inside dimensions. Where internal Portions of ducts visible through diffusers, grilles and registers in insulation is called for, dimensions shall be increased by the thickness Provide flexible connection where supply and return air ducts connect round ductwork to obtain required lengths. and owner's layout, so they will remain unobstructed. Ductwork openings shall be coordinated with MBM for installation by this Contractor. The M.C. to provide ductwork for exterior, insulated and weather-protected and install return air ductwork as required. Where applicable, Owens Corning 1" fiberglass duct board. - OR - THESE NOTES SHALL APPLY UNLESS OTHERWISE INDICATED BY DRAWINGS 1/2 NOTES: 1. DUCTS TO BE TIED TO MAIN EXHAUST FOR SINGLE WALL PENETRATION 2. TIE ACTIVATION OF FAN INTO LIGHT SWITCH FOR SIMULATENOUS OPERATION OF FAN AND LIGHTS BROAN 6"Ø .250 3.0 1000 1151/8 1 1; 2 ALL FIXTURES, LISTED ABOVE, MAY BE BID WITH A PRE-APPROVED EQUAL.NOTE: 100 - 550 950 - 1,725PRICE: 80 CORE (EGG CRATE)RAG SQ/RECT PRICE: SCD SERIESSAD 1 SQUARE RETURN GRILLE/FLUSH MOUNT300 - 400 < 20 NECK AS PER PLANS STL LAY-IN/NECK AS PER PLANS SUPPLY AIR DIFFUSER/T-BAR500 - 800 < 20 STL WHITE O.B.D. WHITE 671 120 100 - 550 PRICE: 510 SERIES SAR RECT MOUNT DIRECTLY TO DUCT SUPPLY AIR REGISTERS500 - 800 < 20 STL STEEL O.B.D. NOT ALL APPLY NOT ALL APPLY 912SD36060 E14 800 20 % 0.75 .75 T-A (2) 2 FU 1 BRYANT NOTE:NOTES: 1. ALL UNITS SHALL BE SET IN DRIP PAN W/ DRAIN LINE TO EXTERIOR OF BUILDING. 2. ALL UNITS SHALL BE COMPLETE WITH 7-DAY ELECTRONIC FULLY PROGRAMMABLE THERMOSTAT w/ LOCKABLE COVER GAS 60,000 80 67 24 18 90 67 24 1.5 13.0 3.5 17 115 8 2.0 20520 1 R410A / 14 REF LBS 95 BA13NA024BNG CU 1 BRYANT 208 17 2.0 225251 SPECIFIC CHART VALUES ARE FOR REFERENCE ONLY ALL PERFORMANCE SHALL BE VERIFIED AGAINST SUBMITTAL SHEETS FORM SUPPLIER. MFG FOR SPECIFIC OF PERFORMANCE AND EQUIPMENT DESCRIPTIONS. STRAP HANGERS (TYP.) SUPPORT DIFFUSER INSULATION O.B. DAMPER 10'-0" MAXIMUM ALLOWABLE LENGTH OF FLEX. DUCT VOLUME DAMPER BRANCH DUCT SUSPENDED ACOUSTICAL CEILING PANEL FLEX DUCT NOT TO SCALE: PDP 400UH 1/2 MODAL 400,000 UH-1 UH-2 400,000 400,000 CU-1 2T FU-1 800 RAG 24X24 SAD 170 SAD 180 SAD 60 SAD 200 SAD 110 SAR 40 SAR 40 EF-1 80 EF-2 80 6"Ø EXHAUST DUCT WC-6 WALL HOOD 12"Ø 14"Ø14"ØRAG 14X14 10"Ø 8"Ø FLEX DUCT-TYP. SPIRAL DUCT -TYP. 4"Ø FURNACE FLUE TO WALL OUTLET LINE SETS TO CONDENSER UNIT UNIT HEATER FLUES UP AND OUT THRU ROOF T 09/14/21