Loading...
HomeMy WebLinkAboutA1.2COPYRIGHT & OWNERSHIP OF DOCUMENTS Project Number: Sheet Title: Issue Date: Sheet Number: Project:CARMEL, INDIANA 46032By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone)FERGUSON OFFICESDrawn By Checked ByPrint Date Revisions:200 SOUTH RANGE LINE ROADSUITE 213INDIANA DESIGN CENTERA1.2 FINISH/ REFLECTED CEILING PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC 7/30/21 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLEPROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BEDUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, JAMES R. STUTZMAN, AIA, CARMEL. 7/30/21 State Release Set TJ MC PLAN NORTH 1 A E G M 11 5 1 1 GEA M 5 1 P L AN N O RT H KEY PLAN SCALE: N.T.S. SECOND FLOOR KITCHEN 102 OFFICE 105 OFFICE 103 OFFICE 106 OPEN OFFICE 100 MEETING AREA 101 B1 B1 B1 B1 C1 FN1 FN1 FN1 FN1 FN1 FN1 FN1 OFFICE 104 P1 P1 P1 P1 P1 P1 P1 P1 P1 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 ALL NEW DOORS TO BE STAINED. SEE SCHEDULE FOR FINISH. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED. CAULK INTERIOR AND EXTERIOR PERIMETERS OF ALL DOOR FRAMES. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. 1. 2. 3. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE UNLESS OTHERWISE NOTED. 4. 1. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. CONTRACTOR TO VERIFY LEAD TIMES AS SOON AS CONTRACT IS AWARDED AND NOTIFY ARCHITECT IF SPECIFIED FINISHES WILL NOT BE AVAILABLE. DESIGN FEES MAY ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. ALTERNATES GENERAL FINISH NOTES PAINT MFG: SHERWIN WILLIAMS COLOR: SW6255 MORNING FOG FINISH: EGGSHELL LOCATION: GENERAL P1 PAINT FINISH LEGEND VINYL BASE MFG: JOHNSONITE COLOR: 63 BURNT UMBER SIZE: 4" COVE LOCATION: NEW WALLS B1 BASE PAINT MFG: SHERWIN WILLIAMS COLOR: SW6257 GIBRAL TAR FINISH: SIMIGLOSS LOCATION: DOOR FRAMES P2 BROADLOOM CARPET MFG: MANNINGTON PATTERN: EVERYWEAR III EVERYWEAR PLUS COLOR: OBSIDIAN 1423 LOCATION: NEW OFFICE C1 FLOORCOVERINGALL PAINTED WALLS AND FRAMES TO BE PATCHED AND REPAINTED. FINISH PLAN NOTES: FN1 CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. LOCATE NEW SMOKE DETECTORS DUE TO LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 7. 6. 5. 4. 3. EXISTING OPEN EXPOSED CEILING TO REMAIN. TOUCH UP PAINT AS NEEDED. EXISTING GRID CEILING SYSTEM TO REMAIN. REPLACE MISSING AND DAMAGED TILES AS REQUIRED FROM BUILDING STANDARD. LINEAR FIXTURES TO BE RELOCATED FROM DEMOLITION. R ADJUST HVAC AS NEEDED FOR NEW WALL LAYOUT. RELOCATE LINEAR FIXTURES REMOVED DURING DEMOLITION. ALL ELECTRICAL IN NEW TENANT SPACE TO BE REMOVED FROM EXISTING TENANT'S PANEL AND TIED INTO A DEDICATED PANEL. RELOCATE EXISTING LIGHT SWITCHES TO THIS LOCATION. SPLIT LIGHTING AND PROVIDE LIGHT SWITCHES IN EACH OFFICE. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: CEILING PLAN NOTES: CP11. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ARCHITECT REVIEW IS FOR AESTHETIC REVIEW ONLY. REFLECTED CEILING LEGEND: CP2 CP3 CP4 CP5 CP6 CP1 CP2 CP4 CP1 CP2 CP4 RR R RR R CP1 CP3 CP4 CP3 CP6 CP6 CP5 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 JG.3 G.4 H H.5 H.9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 10 11 9.1 9.9 10.9 10.85 9 SCALE: 1/4" = 1'-0" 1 Finish Plan A1.2 SCALE: 1/4" = 1'-0" 2 Reflected Ceiling Plan A1.2 N N 09/15/21