HomeMy WebLinkAbout10585 N. Meridian Back FlowRev. 3.3 Date:Phone #: Time In:5:15 AM Time Out:10:30 AM Inspector: Inspector:SO# Time:5:20 AM Operator: A.Has there been any modifications to the system since last inspection? B.Have there been any occupant/hazard changes since last inspection? C.Was there an actuation of a device or alarm since last inspection? D.Is building completely sprinkled? E.Are all systems in service? F.Has piping been checked for stoppage? G.Do low points exist? *All answers in this section are based on the customer's knowledge of the system Comments for A-G: 1)General A. Is there proper clearance between sprinklers and storage -- 18in? B.In area protected by wet system does building appear to be properly heated? C.If required, is hydraulic nameplate in place? D.Is building occupied? E.Are there proper signs on all valves and switches? 2) A.Are all control valves and other valves in the open position and in good condition? B.Are all control valves locked sealed or supervised? C.Were all OS&Y valves lubricated? 3)Tanks, Pumps, Fire Department Connections A.Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and required test performed if needed? B.Are fire department connections in good condition, couplings free and caps in place? C.Are fire department connections accessible and visible? 4)Antifreeze Systems A.Are cold weather valves in proper position? B.This system does not have an antifreeze loop.°F M&J Wilkow CMS Panel Code: Owner / Occupant Last 5-year IPI performed 6/3/2020 by Koorsen Fire and Security (next due June-2025) Inspector's Section (All responses reference current inspections) Control Valves Does Not Apply S. Flater 3833996 System on Test Monitoring Company:Koorsen N. Childers Indianapolis, IN 46290 Inspection & Test Report Inspection Type:Wet/Dry Sprinkler Frequency:Annual January 28, 2021 317-542-1800 M&J Wilkow 10585 N Meridian Yes No NoYes Yes No NoYes Yes No NoYes NoYes NoYes NoYes NoYes NoYes N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Yes NoN/A Yes NoN/A Yes NoN/A Yes NoN/A Yes NoN/A Yes NoN/A Yes No N/A Pass Fail NoYesN/A Some areas were unable to be inspected at this time. Sprinkler Test Inspection Report Page 1 of 4 5)Dry Systems A.Are the air pressure and priming water levels normal? B.Has the air or nitrogen supply system been checked for proper operation? C.Were the low points drained? D.Did quick-opening devices operate satisfactory? E.Is dry valve in a properly heated area? 6)Alarms A.Did water motor gong and/or electric bell test satisfactorily? B.Did electric alarm send signals to the fire alarm panel? C.Did supervisory devices work ? D.Were alarm, trouble, and supervisory signals verified with central station? 7)Sprinklers/Piping/Gauges A.Do sprinklers appear to be free from corrosion, loading, or obstruction? B.If standard sprinklers are over 50 years are they being tested? C.If quick response sprinkler are over 20 years are they being tested? D.Is stock of spare sprinklers and wrench available? E.Does the exterior condition of the sprinkler system appear to be in good condition? F.Are gauges in good condition and reading proper pressure? Manufacturers date or date last tested 2018 8)Stand Pipe / Hose Systems A.Type:Wet No.Combined No.Dry No. Water Supply: B.Are stand pipe and hose systems in good condition? 9)Special Systems / Test Type: A.If occupancy has special systems, have they been tested as required? B.Are they in good condition and were tests satisfactory? C.If testing was required, see attached form or system tags? Time to Alarm Signs Drain Size Static PSI Residual PSI Static PSI Although these comments are not the result of an engineering review, the following improvements are recommended: Time:10:25 AM Operator: M&J Wilkow CMS Panel Code: System Back In Service Monitoring Company:Koorsen See Multi Riser Report Explain any "No" answers: Adjustments or corrections made during this inspections:No corrections made at this time. No recommendations at this time. Possible replace OSY valve on system send quotes Main Drain Location Result Comparable Signs Location Alarm Report Orifice Results Comparable Does Not Apply Inspector's test Smooth Bore Does Not Apply Does Not Apply NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes NoYes N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NoYesN/A NoYesN/A NoYesN/A N/A N/A N/A Multiple Inspector's Test Multiple Risers Some sprinklers are unable to be visually inspected at this time. NoYesN/A NoYesN/A NoYesN/A Sprinkler Test Inspection Report Page 2 of 4 SO# Rev. 3.3 Previous Present Vlv Type Static / Residual Static / Residual Butterfly 100/75 80/65 Butterfly 95/70 110/95 Butterfly 90/70 115/95 Inspected by: Total Qty of Risers Inspected:3Inspected by: S. Flater N. Childers M&J Wilkow 10585 N Meridian Indianapolis, IN 46290 3833996 1st FL Hallway Riser Location 3rd FL Hallway 2nd FL Hallway 39 sec. January 28, 2021 48 sec Time to Alarm (Sec) Next to Valve MULTI RISER REPORT 52 sec. ITV Location Next to Valve Next to Valve Multi Wet Riser Report Page 3 of 4 Ph: # 317-542-1800 Indianapolis,Indiana SO#Page Qty:1 7 Zone or Address Valve Type Size Pass / Fail Sealed 59 OSY 4"Pass 57 OSY 4"Pass 55 OSY 4"Pass 60 PCVS-2 4"Pass 58 POTTER VSR-D 4"Pass 56 POTTER VSR-D 4"Pass 54 POTTER VSR-D 4"Pass1FL Hallway Water Flow 3FL Bastian Solutions Break Room 2 fl Indie Asset Far Left Office Above Window Outside electrical in hall 2 fl Indie Asset Far Left Office Tamper Switch 3FL Bastian Solutions Break Room Tamper Switch Above Window seal Inside Far left office above window seal Tamper Switch WPIV Inside Far left office above window O/S BACK DOOR BY MAIN Water Flow Water Flow Tamper Switch1FL Hallway M&J Wilkow 10585 N Meridian Total devices inspected Indianapolis, IN 46290 Comments January 28, 20212719 N. Arlington Ave Type 3833996 DETECTION INSPECTION REPORT Device(s) failed during this inspection Device Location Sensitivity and Detection Inspection Report Page 4