Loading...
HomeMy WebLinkAboutA111 ARCHITECTURAL FLOOR PLANDWOFFICE 214 OFFICE 213 OFFICE 212 HUDDLE 209 HUDDLE 208 HUDDLE 207 OPEN OFFICE 204 ENTRY 201 CAFE 202 COPY 205 COLLAB 203 COLLAB 216 OPEN OFFICE 215 CONFERENCE 206 PHONE 211 PHONE 210 7'-41 4"9'-5" 9'-5" 9'-5" 8'-0"± 9'-5" 9'-5" 9'-5"12'-7"ALIGN5'-412"5'-412" 2'-6"4'-0"6' - 0 " 9' -0"CL E A R 20'-71 4"135° TYP. 4' - 2 14 " 5'-1"4'-6"FEFE5'-7" 1'-8" HOLDDW4'-1"6'-6" 8'-412"5'-11" 4'-0 3 4" 2'-6"6'-5" 5'-11"12'-0" EQ.EQ. ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW FIRE EXTINGUISHER AND FULLY RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W2". PROVIDE NEW SUITE ENTRY DOOR LOCATION PER NEW WALL LAYOUT; COORDINATE FINAL LOCATION WITH TENANT. INTENT IS FOR EXISTING DOOR + DOOR FRAME TO BE REUSED IN RELOCATION; PROVIDE NEW DOOR FRAME AS REQUIRED. NEW DOOR LOCATION MUST BE IN COMPLIANCE WITH ALL STATE AND LOCAL CODES. PROVIDE ALTERNATE PRICE $10,000 ALLOWANCE FOR CUSTOM RECEPTION DESK. MATERIALS MAY INCLUDE QUARTZ, WOOD VENEER, PLASTIC LAMINATE, METAL, ETC. FINAL DESIGN TBD. PROVIDE ALTERNATE PRICE TO RELOCATE TENANT'S EXISTING RECEPTION DESK FROM 3RD FLOOR TO THIS LOCATION. EXISTING DESK MAY REQUIRE MODIFICATIONS. COORDINATE ALL DETAILS WITH TENANT. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR COFFEE AND TENANT'S WATER MACHINE. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION. PLAN NOTES ARCHITECTURAL PLAN WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; SEE ELEVATION FOR WALL HEIGHT; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED. W3 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 08.13.21 REVIEW SET 08.18.21 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR BASTIAN SOLUTIONSONE MERIDIAN PLAZA | SUITE 20010585 N. MERIDIAN ST, INDIANAPOLIS, IN 46290EHEH 2021.130 2ND FLOOR N 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. GENERAL NOTES W? AREA NOT IN CONTRACT AREA OF WORK A111 1 0 4' 8'2' ENLARGED PLAN - ENTRY 201 + CAFE 202 A111 1 W2 W3 W3 W3 A211 3 A211 2 A211 5 W2 W2 W2 W2 W2W2 W2 W2 W2 A211 4 09/16/21