HomeMy WebLinkAboutA121 REFLECTED CEILINGSN3 SNSNSNSNSN SNSNSNSNSN ELNELN ELNELNSN3SNSNSNSNSNSN3 SN SNSNSN SNSNSNSNSN ELNELN ELN ELNELN ELNSN3ELNSN SN SN SNSNSNREFLECTED CEILING PLAN A121 IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND PREPARE FOR DRYFALL PAINT (PT_). AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING, ETC. IN ACCORDANCE WITH NFPA 13 6.3.8. TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 5" WIDE DRYWALL BULKHEAD EXTENDING FROM 8'-0" AFF TO DECK AND ALIGNING WITH ADJACENT WALLS AS SHOWN. TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. PROVIDE FLOATING DRYWALL CEILING AT 10'-0" AFF AT THIS LOCATION WITH 6" ARMSTRONG AXIOM TRIM AT EXPOSED EDGE. VERTICAL FACE OF DRYWALL DOES NOT EXTEND TO DECK AT THIS LOCATION. EXTEND DRYFALL PAINT ON DECK ABOVE BEYOND EDGE OF BULKHEAD AS FAR BACK AS REQUIRED SUCH THAT ALL VISIBLE DECK AND COMPONENTS FROM EYE-LEVEL AT ANY POINT IN THE SPACE IS FINISHED WITH PT_. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CEILING IN THIS AREA. CONTROL LINEAR LIGHT FIXTURES IN ENTRY 201 + CAFE 202 WITH SWITCH AT THIS LOCATION. CONTROL OPEN OFFICE AND COPY LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. PROVIDE SEPARATE PRICE FOR ADJUSTED CEILING LAYOUT IN THIS LOCATION. SEPARATE PRICE TO INCLUDE INSTALLATION OF (6) 80"X200" FRASCH VINE SUSPENDED ACOUSTIC CLOUD SYSTEMS (CLOUDS BY TENANT) WITH (5) 16' LED LINEARS AS SHOWN (LIGHTING AND INSTALLATION BY GC). IF SEPARATE PRICE IS ACCEPTED, COORDINATE FINAL INSTALLATION HEIGHTS WITH SDI. PROVIDE 4' WIDE DIRECT/INDIRECT SURFACE MOUNTED LED LINEAR LIGHT FIXTURE AT THIS LOCATION. FINAL HEIGHT TBD. PLAN NOTES LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH, DIMMERN N3 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, PENDANT. ASSUME $1,000 MATERIAL COST TOTAL FOR ALL PENDANTS RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', LED, COLUMBIA LIGHTING CCL LIGHT FIXTURE, 2'x4', LED COLUMBIA LIGHTING CCL RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 1'x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NIGHT LIGHT NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC LEGEND REFLECTED CEILING PLAN - BASE BID DESCRIPTIONDATE ISSUE 08.13.21 REVIEW SET 08.18.21 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR BASTIAN SOLUTIONSONE MERIDIAN PLAZA | SUITE 20010585 N. MERIDIAN ST, INDIANAPOLIS, IN 46290EHEH 2021.130 2ND FLOOR N 0 2'4'8'16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING EXPOSED TO DECK A121 1 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED; PROVIDE NEW TO MATCH EXISTING AND REPAINT ALL GRID IN SHERWIN WILLIAMS CEILING BRIGHT WHITE WITH PAINT SPECIFICATION APPROPRIATE FOR SUBSTRATE. EXISTING GRID IS 2x2 AT 8'-4" A.F.F. PROVIDE NEW 2x2 ACOUSTICAL LAY IN TILES THROUGHOUT; CONFIRM SPECIFICATION WITH TENANT. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. ALL DEVICES AND FACE PLATES TO BE WHITE; REPLACE EXISTING AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES AREA NOT IN CONTRACT AREA OF WORK 0 2' 4' 8' 16' REFLECTED CEILING PLAN - ALTERNATIVE LAYOUT 0 2' 4' 8' 16' LIGHT FIXTURE, LINEAR LED, FINELITE HP-4 ID; LENGTHS NOTED ON PLANS 09/16/21