HomeMy WebLinkAboutLS100.1TVTVENTRY201
OPEN OFFICE
203COLLABORATION
218
COPY217
FUTUREOPEN OFFICE
215
OPEN OFFICE
214
COPY208
x
CONFERENCE
202
29'-9"16'-1"
x
OFFICE
204
11'-3"10'-0"
x
OFFICE
205
11'-3"10'-0"
x
OFFICE206
11'-3"10'-0"
x
SERVER
207
11'-3"10'-0"
x
OFFICE
209
11'-3"10'-0"
x
OFFICE
210
11'-3"10'-0"x
OFFICE
211
10'-0"12'-4"x
OFFICE
212
10'-0"12'-4"
x
OFFICE
213
10'-1"12'-4"
x
BREAK216
30'-7"16'-2"
x
CONFERENCE
219
24'-7"17'-0"
REFRIGBYTENANT
FEELELEL ELEL
ELFEREFRIGBYTENANT ICE
LIFE SAFETY
PLAN
L100
DESCRIPTIONDATE
ISSUE
07.15.21 REVIEW SET
07.21.21 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR METRONETCITY CENTER AT PENN, SUITE 2751320 CITY CENTER DRIVE, CARMEL, IN 46032CBEH
2021.200
2ND FLOOR
N
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
LIFE SAFETY NOTES
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
L3. SQUARE FOOTAGES NOTED IN CODE SUMMARY CHART ARE NOT
REFLECTIVE OF USABLE/RENTABLE SQUARE FOOTAGE AS CALCULATED
BY METHODS SUCH AS BOMA STANDARDS. OCCUPANCY
CALCULATIONS & TOTALS ARE CALCULATED BASED ON
INTERNATIONAL BUILDING CODE NOT ACTUAL HEAD COUNTS.
CONTACT SDI FOR ADDITIONAL INFORMATION AS NECESSARY.
GENERAL NOTES
LIFE SAFETY PLAN AREA NOT IN CONTRACT
AREA OF WORK
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
45,576 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 125
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
12,460
12,460
45,576 3 136,728
125
BUILDING CONSTRUCTION TYPE II-B
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FE
- BUILDING STAIR LOCATION
TRAVEL DISTANCE
NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3
- LED EDGE LIT
TRAVEL DISTANCE = 199'
0 4' 8' 16'
EP
EX
EX
EX