Loading...
HomeMy WebLinkAboutLS100.1TVTVENTRY201 OPEN OFFICE 203COLLABORATION 218 COPY217 FUTUREOPEN OFFICE 215 OPEN OFFICE 214 COPY208 x CONFERENCE 202 29'-9"16'-1" x OFFICE 204 11'-3"10'-0" x OFFICE 205 11'-3"10'-0" x OFFICE206 11'-3"10'-0" x SERVER 207 11'-3"10'-0" x OFFICE 209 11'-3"10'-0" x OFFICE 210 11'-3"10'-0"x OFFICE 211 10'-0"12'-4"x OFFICE 212 10'-0"12'-4" x OFFICE 213 10'-1"12'-4" x BREAK216 30'-7"16'-2" x CONFERENCE 219 24'-7"17'-0" REFRIGBYTENANT FEELELEL ELEL ELFEREFRIGBYTENANT ICE LIFE SAFETY PLAN L100 DESCRIPTIONDATE ISSUE 07.15.21 REVIEW SET 07.21.21 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR METRONETCITY CENTER AT PENN, SUITE 2751320 CITY CENTER DRIVE, CARMEL, IN 46032CBEH 2021.200 2ND FLOOR N 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. L3. SQUARE FOOTAGES NOTED IN CODE SUMMARY CHART ARE NOT REFLECTIVE OF USABLE/RENTABLE SQUARE FOOTAGE AS CALCULATED BY METHODS SUCH AS BOMA STANDARDS. OCCUPANCY CALCULATIONS & TOTALS ARE CALCULATED BASED ON INTERNATIONAL BUILDING CODE NOT ACTUAL HEAD COUNTS. CONTACT SDI FOR ADDITIONAL INFORMATION AS NECESSARY. GENERAL NOTES LIFE SAFETY PLAN AREA NOT IN CONTRACT AREA OF WORK SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 45,576 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 125 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 12,460 12,460 45,576 3 136,728 125 BUILDING CONSTRUCTION TYPE II-B EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN EMERGENCY LIGHT FE - BUILDING STAIR LOCATION TRAVEL DISTANCE NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3 - LED EDGE LIT TRAVEL DISTANCE = 199' 0 4' 8' 16' EP EX EX EX 09/16/21