HomeMy WebLinkAboutA010.1WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
ENTRY
201
OPEN OFFICE
203
COLLABORATION
218
COPY
217
FUTURE
OPEN OFFICE
215
OPEN OFFICE
214
COPY
208
CONFERENCE
202
OFFICE
204
OFFICE
205
OFFICE
206
SERVER
207
OFFICE
209
OFFICE
210
OFFICE
211
OFFICE
212
OFFICE
213
BREAK
216
CONFERENCE
219 FE10'-4" 10'-4" 10'-4" 4'-6" 10'-4"10'-4"11'-7"10'-7"10'-4"12'-8"ALIGNFEARCHITECTURAL
FLOOR PLAN
A111
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
EXISTING FIRE EXTINGUISHER TO REMAIN IF IN PROPER WORKING
ORDER. CONTRACTOR TO CONFIRM THAT EXISTING FIRE
EXTINGUISHER IS INSTALLED ACCORDING TO NFPA 10.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT. AT EXISTING LOCATION CONTRACTOR
TO ENSURE REQUIREMENTS ARE MET.
CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,
ALTER EXISTING WALL AS REQUIRED TO MATCH "W2".
DESIGN INTENT IS TO REUSE EXISTING UPPER CABINETS AND
HARDWARE. PATCH, REPAIR, AND CLEAN TO LIKE NEW
CONDITION. PROVIDE NEW PLASTIC LAMINATE COUNTERTOP
AND BASE CABINETS IN SAME LAYOUT. REFER TO A131 AND A211
FOR ADDITIONAL INFORMATION.
PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AT THIS LOCATION.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
_______________________________________________________________
PROVIDE WATER LINE FOR COFFEE AND ICE MAKER. CONFIRM
LOCATION WITH TENANT.
DESIGN INTENT IS TO REUSE EXISTING PLUMBING LINE AND INSTALL
NEW SINK AND FAUCET IN SAME LOCATION.
PLAN NOTES
ARCHITECTURAL PLAN AREA NOT IN CONTRACT
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DEMISING WALL TO DECK
WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W1 WALL WITH INSULATION
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W2
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DESCRIPTIONDATE
ISSUE
07.15.21 REVIEW SET
07.21.21 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR METRONETCITY CENTER AT PENN, SUITE 2751320 CITY CENTER DRIVE, CARMEL, IN 46032CBEH
2021.200
2ND FLOOR
N
0 2' 4' 8' 16'
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
GENERAL NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
W?
TYP.
A111
1
W2
09/16/21