HomeMy WebLinkAboutA010.2ELSN ELEL ELEL ELSN SNSN4SN N N SN NSNNSN REFLECTED CEILING PLAN A121 CONTROL ENTRY 201, OPEN OFFICE 203, COPY 208, OPEN OFFICE 214, FUTURE OPEN OFFICE 215, COPY 217, AND COLLABORATION 218 LIGHTING WITH SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. DESIGN INTENT IS TO MODIFY EXISTING SWITCHES TO BE 4-WAY AS REQUIRED. EXISTING EXPOSED CEILING TO REMAIN. TOUCH UP PAINT TO LIKE NEW CONDITION. EXISTING DRYWALL CEILING TO REMAIN. TOUCH UP PAINT TO LIKE NEW CONDITION. PLAN NOTES LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH, DIMMERN N3 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, PENDANT($500 MATERIAL ALLOWANCE PER FIXTURE) RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x4', DIRECT, FLUORESCENT RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, PENDANT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x4', DIRECT, FLUORESCENT LEGEND REFLECTED CEILING PLAN RECESSED LIGHT FIXTURE DESCRIPTIONDATE ISSUE 07.15.21 REVIEW SET 07.21.21 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR METRONETCITY CENTER AT PENN, SUITE 2751320 CITY CENTER DRIVE, CARMEL, IN 46032CBEH 2021.200 2ND FLOOR N 0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP GYPSUM BOARD CEILING SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL EXPOSED TO DECK A121 1 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'-6" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 8. PROVIDE SEPARATE PRICE TO REPLACE ALL EXISTING 2X4 LIGHT FIXTURES TO NEW 2X4 FLAT PANEL 4K LED LIGHT FIXTURES THROUGHOUT. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES AREA NOT IN CONTRACT AREA OF WORK 09/16/21