REFLECTED
CEILING PLAN
A121
CONTROL ENTRY 201, OPEN OFFICE 203, COPY 208, OPEN OFFICE
214, FUTURE OPEN OFFICE 215, COPY 217, AND COLLABORATION
218 LIGHTING WITH SWITCH AT THIS LOCATION. PROVIDE MULTIPLE
SWITCHES AS REQUIRED. DESIGN INTENT IS TO MODIFY EXISTING
SWITCHES TO BE 4-WAY AS REQUIRED.
EXISTING EXPOSED CEILING TO REMAIN. TOUCH UP PAINT TO LIKE
NEW CONDITION.
EXISTING DRYWALL CEILING TO REMAIN. TOUCH UP PAINT TO LIKE
NEW CONDITION.
PLAN NOTES
LIGHT CIRCUIT
LIGHT SWITCH, 3-WAY
LIGHT SWITCH, DIMMERN
N3 3
EXIT LIGHT FIXTURE
LIGHT FIXTURE,
PENDANT($500 MATERIAL
ALLOWANCE PER FIXTURE)
RECESSED LIGHT
FIXTURE
LIGHT FIXTURE, 2'x4', DIRECT,
FLUORESCENT
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE,
PENDANT
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 2'x2'
GYPSUM BOARD CEILING
LIGHT FIXTURE, 2'x4', DIRECT,
FLUORESCENT
LEGEND
REFLECTED CEILING PLAN
RECESSED LIGHT
FIXTURE
DESCRIPTIONDATE
ISSUE
07.15.21 REVIEW SET
07.21.21 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR METRONETCITY CENTER AT PENN, SUITE 2751320 CITY CENTER DRIVE, CARMEL, IN 46032CBEH
2021.200
2ND FLOOR
N
0 2' 4' 8' 16'
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE
MECHANICAL DIFFUSER RELOCATION
A121
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING VAV BOXES OR
HEAT PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
VAV /
HEAT PUMP
GYPSUM BOARD CEILING
SWITCH, GARBAGE
DISPOSAL (ABOVE
COUNTERTOP)
NG G SWITCH, GARBAGE
DISPOSAL
EXPOSED TO DECK
A121
1
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 9'-6" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED
TILES WITH NEW TO MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR
RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION
AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS
THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW
AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING.
LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
8. PROVIDE SEPARATE PRICE TO REPLACE ALL EXISTING 2X4 LIGHT
FIXTURES TO NEW 2X4 FLAT PANEL 4K LED LIGHT FIXTURES
THROUGHOUT.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
AREA NOT IN CONTRACT
AREA OF WORK
09/16/21