Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A502 WALL SECTIONS
6 MTL STUD FRAMING @ 16" O.C. NEW VESTIBULE 3.5" MTL STUD FRAMING @ 16" O.C. CLIP TO EXISTING STEEL - EXACT STEEL LOCATION & ELEV. V.I.F. ALUM. STOREFRONT GLAZING SYSTEM TO MATCH EXISTING SYSTEM EXISTING ALUM. STOREFRONT SYSTEM REPAIR EXISTING E.I.F.S. SYSTEM TO NEW VESTIBULE FRAME - FINISH PER EXTERIOR FINISH SCHEDULES 4" POURED CONCRETE FLOOR ON ENGINEERED FILL - COMPACTED IN 6" LIFTS - PROVIDE 2"X24" PERIMETER INSULATION 12" EXPANSION JOINT MATERIAL FLOOR TILE PER PER FLOOR FINISHES - TILE BASE & SCHLUTER RONDEC-DB TRIM AT TOP OF BASE FORMED & POURED CONCRETE WALL EXISTING CONC PAVING - REPAIR TO NEW VESTIBULE STRUCTURE EXISTING COVERED OUTDOOR DISPLAY LINE OF ROOF & SKYLIGHT FRAME ABOVE WALK OFF MATT INSET NEW LINEAR METAL SLAT BARREL VAULT & SOFFITS POUR CONCRETE FLOOR OVER EXIST'G CMU - DOWEL SLABS TOGETHER W/#4 @ 48" O.C. EXIST'G FLOOR ENGINEERED FILL PROVIDE 12" EXP. JOINT MATERIAL 3 COURSES 6" CMU GROUT SOLID - ALIGN TOP WITH FIN. FLR. CT-2 TILE FLOOR PER FIN FLR SCHEDULES 4" POURED CONC. FLOOR W/6"X6"XW2.9XW2.9 WWF REINF. ON 6MIL VAPOR BARRIER ON ENGINEERED FILL IN 6" LIFTS #4 REBARS @32" O.C. - TIE INTO POURED CONC. FLOOR 58" GYP BD OVER 1" HAT CHANNEL FURRING ON CMU EXISTING CONC. FLOOR REMAINS - CUT 4" HOLES IN ±3' GRID AND FILL WITH GRAVEL PLUMBING AS REQUIRED - SEE ENGINEERING DWGS sARAVIA v-1504 lIFT or equal., iNSTALL PER MAN. GUIDELINES CEILING 10'-0" door swing NEW VESTIBULE COVERED OUTDOOR DISPLAY 6 MTL STUD FRAMING @ 16" O.C. 3.5" MTL STUD FRAMING @ 16" O.C. CLIP TO EXISTING STEEL - EXACT STEEL LOCATION V.I.F. ALUM. STOREFRONT GLAZING SYSTEM TO MATCH EXISTING SYSTEM 4" POURED CONCRETE FLOOR ON ENGINEERED FILL - COMPACTED IN 6" LIFTS - PROVIDE 2"X24" PERIMETER INSULATION 12" EXPANSION JOINT MATERIAL FLOOR TILE PER FLOOR FINISHES - WALK OFF MATT INSET PER MFG. SPEC'S FORMED & POURED CONCRETE WALL SEE STRUCTURAL DRAWINGS FOR INFORMATION & DETAILS ON POURED CONC. FOOTINGS REMOVE & REPLACE WITH NEW 4" LINEAR METAL TILE CEILING - COLOR TO MATCH P-3 SEE STRUCTURAL DRAWINGS FOR NEW STAIR DETAILS ALUM. STOREFRONT GLAZING POWER SL. GL. DOORS SYSTEM - FRAME FINISH TO MATCH EXISITNG STOREFRONT GLAZING SYSTEM DROPS BELOW SOFFIT @ SIDES A 502WALLSECTIONS1 SECTION SCALE: 1/2"=1'-0"A102 A502 3 SECTION SCALE: 1"=1'-0"A102 A502 Copyright © 2018: This document and the subject matter contained herein is proprietary and may notbe reproduced without the written permission of TDG Architects, LLC.Drawing TitleDrawing Number 18-840.01 Project Number © COPYRIGHT 2018 TDG Architects HONDA NEW CARDEALERSHIP REMODELPENSKE AUTOMOTIVE GROUP2555 S. Telegraph RoadBloomfield Hills MI 4830279 Oakland AvenueP.(248) 874-1420Pontiac, Michigan 48342F. (248) 758-9926TDGArchitects.com 4140 East 96th Street,Carmel IN 46240Revision Schedule Date DescriptionClientProjectAutomotive Drawn By: Checked By: 12/4/18 cleint review 12/28/18 HONDA review 4/5/19 REVEIW FOR PERMIT 6/26/19 permits meh bsj 10/3/19 bids 10/23/19 change-up approval 11/14/19 bza- meeting 3/18/21 approval 5/21/21 reissued for permits & bids 7/12/21 revised for permits 2 SECTION SCALE: 1/2"=1'-0"A102 A502 09/16/21