Loading...
HomeMy WebLinkAboutA100 OVERALL FLOOR PLAN12 13 14 1511 15.115.5 A B C D E F G H J K L E.8 F.2 F.8 G.2 VEHICLE DISPLAY 102 RECEPTION 101 CONSULTATION AREA 105 INFORMATION CENTER 106 FEATURE VEHICLE 104 CONSULTATION AREA 103 VESTIBULE 100 COVERED OUTDOOR DISPLAY 000 OFFICE 107 SALES MANAGER 108 GENERAL MANAGER 110 STORAGE 111 UTILITY ROOM 112 WOMEN'S 113 MEN'S 114 HALL 116 CUSTOMER'S LOUNGE 117 BDC 118 OFFICE 122 HALL 119 NEW CAR DELIV. 131 MECHANICAL 123 F & I WAITING 132 HALL 115 OFFICE 121 OFFICE 120 F&I MANAGER 109 PARTS BOUTIQUE 137 new glass vestibule and stairs. 1 A101 DETAIL 139 STAIR 128 STAIR 129 n.I.C. SERVICE 138 n.I.C. F & I 124 F & I 125 F & I 128 F & I 129 NEW CAR DELIV. 130 new CHair lift. F & I 134 F & I 127 NEW CAR DELIV. 136 NEW CAR DELIV. 135 HALL 126 new lARGE SCREEN MONITORS. A. ALL DIMENSIONS ARE FROM FINISHED FACE OF MATERIAL TO FINISHED FACE OF MATERIAL. B. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK. REPORT ANY DISCREPANCIES TO ARCHITECT / OWNER. C. INSPECT ALL EXISTING WALLS THAT ARE TO REMAIN FOR DAMAGE. PATCH WALLS TO MATCH ADJACENT SURFACE AND PREP FOR NEW FINISHES AS SCHEDULE. D. all equipment & fixtures by owner u.n.o. E. install all fire extinguishers & their designated locations as required per fire marshal F. aLL SIGNAGE TYPE, LOCATION & OPTIONS SHALL BE DECIDED BY OWNER. ALSO SEE GENERAL NOTE 'E' THIS SHEET. SIGNAGE SHALL MEET ALL APPLICABLE CODES & ADA REQUIREMENTS. GENERAL CONSTRUCTION NOTESSOUTH EXIT A EAST EXIT B VERTICAL EXIT ENCLOSURE EAST EXIT C WEST EXIT D WEST EXIT E VERTICAL EXIT ENCLOSURE [60] (360)proposed construction no frr EXISTING CONSTRUCTION NO FRR EXISTING/NEW 1-HOUR FRR CONSTRUCTION EXISTING/NEW 2-HOUR FRR CONSTRUCTION EXISTING 3-HOUR FRR CONSTRUCTION EXIT TRAVEL DISTANCE EXIT DISCHARGE CAPACITY OF EXIT OCCUPANT LOAD AT EXIT[###] (###) 57' LIFE SAFETY PLAN LEGEND ALL EXISTING FIRE DOORS ALONG RATED WALL SHALL REMAIN - INSPECT FOR PROPER OPERATION - REPAIR AS NEEDED. EXISTING AREAS THIS SIDE OF FIRE WALL N.I.C. & SHALL REMAIN [60] (180) [33] (180) [33] (180) [60] (180)EXISTING AREAS SECOND FLOOR ARE EXISTING & N.I.C. & SHALL REMAIN existing roll-up fire shutters to remain. A 100OVERALLSALES FLOOR PLANHONDA DEALERSHIP FLOOR PLAN SCALE: 1/16"=1'-0" 0' 10' 40' LIFE SAFETY FLOOR PLAN SCALE: N.T.S.Copyright © 2018: This document and the subject matter contained herein is proprietary and may notbe reproduced without the written permission of TDG Architects, LLC.Drawing TitleDrawing Number 18-840.01 Project Number © COPYRIGHT 2018 TDG Architects HONDA NEW CARDEALERSHIP REMODELPENSKE AUTOMOTIVE GROUP2555 S. Telegraph RoadBloomfield Hills MI 4830279 Oakland AvenueP.(248) 874-1420Pontiac, Michigan 48342F. (248) 758-9926TDGArchitects.com 4140 East 96th Street,Carmel IN 46240Revision Schedule Date DescriptionClientProjectAutomotive Drawn By: Checked By: 12/4/18 cleint review 12/28/18 HONDA review 4/5/19 REVEIW FOR PERMIT 6/26/19 permits meh bsj 10/3/19 bids 10/23/19 change-up approval 11/14/19 bza- meeting 3/18/21 approval 5/21/21 reissued for permits & bids 7/12/21 revised for permits 09/16/21