Loading...
HomeMy WebLinkAboutA103 ENGLARED FLOOR PLANSHALL 116 BDC 118 F&I MANAGER 109 1 1 14 1 2 8 9 FLOOR FINISH - SEE SHEET A801 FURNISHINGS BY OWNER 5 A703 CUSTOMER'S LOUNGE 117 STAINLESS STEEL RAIL. 1 10 1 14 4 4 4 existing CONCRETE BLOCK wall OR CONSTRUCTED WALL to remain. 5/8" GYP. BD. ONE SIDE ON 2 1/2" 22 GA. MTL. STUDS @ 16" O.C. EXTEND FRAME TO DECK. 5/8" GYP. BD. ON BOTH SIDES OF 3 5/8" 25 GA. MTL. STUDS @ 16" O.C., EXTEND FRAME TO EXISTING HEADER. 5/8" GYP. BD. ON BOTH SIDES OF 6" 25 GA. MTL. STUDS @ 16" O.C., EXTEND WALL TO DECK - USE TILE BACKER GYPSUM BD ON LAVATORY SIDE, AND WET WALLS. 5/8" plywd on 6" 16 ga. mtl. studs @ 16" o.c. 5/8" GYP. BD. ON TWO SIDES OF 3 5/8" 22 GA. MTL. STUDS @ 16" O.C., EXTEND WALL TO DECK. provide tile backer GYPSUM ON wet side. 5/8" gyp bd on ONE side of 3 5/8" 22 GA. MTL STUDS @ 16" O.C. EXTEND WALL TO DECK. USE TILE BACKER GYPSUM ON LAVATORY WALLS. 4" PRE-FINISHED/PRE-COLORED SPLIT FACED CMU BASE W/STONE CAP. 5/8" GYP BD EACH SIDE ON 3 5/8" 22 GA. METAL STUDS 16" O.C. EXTEND WALL TO DECK. BASE OF WALL - EXTENDED GYP BD ON 1" METAL HAT CHANNELS ON 6" CMU. ALIGN FACE OF CHANNELS WITH FACE OF STUDS. PROVIDE TILE BACKER GYPSUM ON WET SIDE. NEW 8" CMU WALL, 40" HEIGHT, MATCH EXISTING COURSING & LAYOUT. 58" CDX PLYWOOD ON 8" - 16 GA. METAL STUDS @ 16" O.C. W/SIMPSONS PPSD (#8X2") SELF TAPPING SCREWS W/QUICK-GUARD COATING 6" @ PERIMETER 12" IN FIELD. FINISH PER EXTERIOR ELEVATIONS WALL TYPES - SEE SHEETS A801 - A805 FOR FINISHES 1 2 3 4 5 6 7 8 9 10 11 1 INDICATES OUTLINE OF EXISTING OVERHEAD SOFFIT WALL OR CANOPY. EXISTING STEEL COLUMN TO REMAIN (TYPICAL). NEW MASONRY / EFIS COLUMN ENCLOSURE SEE DETAILS FOR MORE INFORMATION (TYPICAL). EXISTING GLAZING TO REMAIN. EXISTING ENTRY DOORS TO REMAIN. NEW CLEAR ANOD. INSULATED WINDOWS & DOORS. SEE WINDOW SCHEDULED FOR MORE INFORMATION. NEW CONCRETE Stair see section 2 A502 for more information. MILLWORK SUPPLIED AND Installed BY OWNER. wall mounted TV supplied and installed by owner. REINFORCE WALL AS NEEDED FOR MOUNTS. NEW PLUMBING FIXTURES - WATER SERVICE & SANITARY EXISTING ELECTRICAL SERVICE TO BE REWORKED. EXISTING PIPE BOLLARD COVER WITH SLEEVE. PROVIDE 1" METAL PARTITIONS. "INFORMATION WALL" CONSTRUCTION BY MILLWORK CONTRACTOR - MILLWORK CONTRACTOR PER OWNER. EXISTING ELECTRICAL SERVICE SHALL REMAIN THIS WALL. CONSTRUCT NEW CONCRETE FLOOR ADJACENT EXISTING & SHALL BE ALIGNED WITH EXISTING. SLOPE NEW FLOOR AREAS AS NEEDED TO NEW DRAINS. nEW BUTT GLAZING. 2 3 4 5 6 7 8 9 10 11 12 CONSTRUCTION NOTES 13 14 15 16 17 EXISTING METAL ROOFING OVER BARREL VAULT ENTRY - REMAINS EXISTING FLAT ROOF AREA - REMAINS CANT CANT SLOPE SLOPE EXISTING RIDGE TO MTL ROOF SLOPE NEW SADDLE SLOPENEW PARAPET FOR HONDA CYLINDER WALL NEW SHED ROOF FOR HONDA CYLINDER EXISTING BUILDING FACADE EXISTING BUILDING FACADE 25'-8" T.O.P. 29'-0" T.O.P. SHED ROOF Copyright © 2018: This document and the subject matter contained herein is proprietary and may notbe reproduced without the written permission of TDG Architects, LLC.Drawing TitleDrawing Number 18-840.01 Project Number © COPYRIGHT 2018 TDG Architects HONDA NEW CARDEALERSHIP REMODELPENSKE AUTOMOTIVE GROUP2555 S. Telegraph RoadBloomfield Hills MI 4830279 Oakland AvenueP.(248) 874-1420Pontiac, Michigan 48342F. (248) 758-9926TDGArchitects.com 4140 East 96th Street,Carmel IN 46240Revision Schedule Date DescriptionClientProjectAutomotive Drawn By: Checked By: 12/4/18 cleint review 12/28/18 HONDA review 4/5/19 REVEIW FOR PERMIT 6/26/19 permits meh bsj 10/3/19 bids 10/23/19 change-up approval 11/14/19 bza- meeting 3/18/21 approval 5/21/21 reissued for permits & bids 7/12/21 revised for permits A 103ENLARGEDFLOOR PLANSPARTIAL ROOF PLAN SCALE: 1/4"=1'-0" 2 ENLARGED FLOOR PLAN SCALE: 1/2" =1'-0"A101 A103 KEY PLAN NOT TO SCALE Area Shown in Plan Area Shown in Plan at Roof 09/16/21