HomeMy WebLinkAboutS003 GENERAL NOTESProject Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:57 PMS003 GENERAL NOTES 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 DEFORMED BAR ANCHORS AND HEADED ANCHOR STUDS DEFORMED BAR ANCHORS (DBA) AND HEADED ANCHOR STUDS (HAS) USED TO ANCHOR STEEL ELEMENTS TO CONCRETE SHALL BE SUPPLIED AND INSTALLED BY THE STRUCTURAL STEEL CONTRACTOR, UNLESS NOTED OTHERWISE. ANCHORS SHALL BE FULL-BASE WELDED USING AUTOMATICALLY TIMED WELDING EQUIPMENT AND APPROPRIATE FERRULE IN ACCORDANCE WITH APPLICABLE PROVISIONS OF AWS D1.5. DEFORMED BAR ANCHORS SHALL BE TYPE C DEFORMED STEEL BARS MANUFACTURED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM A496, WITH A YIELD STRENGTH OF 70 KSI. HEADED ANCHOR STUDS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM A108, WITH A YIELD STRENGTH OF 50 KSI. WHEN APPROVED IN ADVANCE BY THE STRUCTURAL ENGINEER, INTERNALLY THREADED WELDED COUPLERS WITH FULLY DEVELOPED THREADED-END REBAR OF EQUIVALENT SIZE MAY BE USED IN LIEU OF DIRECT-WELDED DEFORMED BAR ANCHORS AS NEEDED FOR CONSTRUCTION PHASING LOGISTICS AND/OR ADHERENCE TO OSHA REQUIREMENTS. STEEL FLOOR DECK PROVIDE AND ERECT STEEL DECK IN ACCORDANCE WITH THE LATEST EDITION OF THE STEEL DECK INSTITUTE'S SPECIFICATIONS AND CODE OF STANDARD PRACTICE. DECK MANUFACTURER SHALL PROVIDE ALL FLOOR DECK ACCESSORIES, SUCH AS EDGE FORMS, CLOSURES, FILLERS AND POUR STOPS FOR A COMPLETE INSTALLATION, WHETHER OR NOT SUCH ITEMS ARE DETAILED ON THE CONTRACT DOCUMENTS. FASTEN FLOOR DECK TO STEEL SUPPORTS AS INDICATED ON THE DRAWINGS. PERFORM WELDING IN ACCORDANCE WITH ANSI/AWS D1.3. STEEL FLOOR DECK IS INTENDED TO BE INSTALLED IN AN UNSHORED CONDITION UNLESS NOTED OTHERWISE. DECK SUPPLIER SHALL REVIEW ALL SPAN CONDITIONS AND CONFIRM THAT THE SUPPLIED PRODUCT IS SUFFICIENT TO SAFELY SUPPORT THE WET WEIGHT OF CONCRETE AND ASSOCIATED CONSTRUCTION LIVE LOADS WITHOUT THE NEED FOR SHORING. FLOOR DECK UNITS SHALL BE INSTALLED IN A MINIMUM THREE SPAN CONDITION WHEREVER POSSIBLE. WHERE THREE SPAN CONDITION IS NOT POSSIBLE, NOTIFY STRUCTURAL ENGINEER PRIOR TO FABRICATION OF DECK SO THAT EVALUATION OF THE LESSER SPAN CONDITION(S) CAN BE PERFORMED. PROVIDE INTERIOR STEEL FLOOR DECK WITH FINISH AS INDICATED ON THE DRAWINGS. PROVIDE FLOOR DECK SUPPORTING EXTERIOR SLABS WITH A GALVANIZED FINISH IN ACCORDANCE WITH ASTM A924 G90. DESIGN DATA NEW STRUCTURES ON THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE. SEE LOAD MAPS FOR LOADING INFORMATION. UNLESS OTHERWISE NOTED, FLOOR FRAMING HAS BEEN DESIGNED UTILIZING LIVE LOAD REDUCTIONS TO THE EXTENT ALLOWED BY THE BUILDING CODE. VIBRATION CRITERIA UNLESS NOTED OTHERWISE, ELEVATED STRUCTURAL STEEL FLOOR FRAMING HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS OF "VIBRATIONS OF STEEL-FRAMED SYSTEMS DUE TO HUMAN ACTIVITY" (2016) BY MURRAY, ALLEN, UNGAR AND DAVIS, WITH ASSUMED DAMPING AND LIMITING VIBRATION CRITERIA AS FOLLOWS: TYPICAL FLOORS, UNO: DAMPING RATIO, BETA = 0.020 MAXIMUM VIBRATION ACCELERATION = 0.5% OF GRAVITY THE STRUCTURE IS NOT DESIGNED TO MITIGATE VIBRATIONS FROM VIBRATING EQUIPMENT. EQUIPMENT CONTRACTOR SHALL PROVIDE AND INSTALL VIBRATION ISOLATORS AS REQUIRED TO MITIGATE EQUIPMENT VIBRATION. SNOW LOAD DESIGN DATA GROUND SNOW LOAD (PG) = 20 PSF SNOW EXPOSURE FACTOR (CE) = 1.0 THERMAL FACTOR (CT) = 1.0 SNOW LOAD IMPORTANCE FACTOR (IS) = 1.0 MINIMUM LOW-SLOPE ROOF SNOW LOAD (PM) = 20 PSF WIND LOAD DESIGN DATA BASIC WIND SPEED (3-SECOND GUST) = 115 MPH WIND EXPOSURE = C WIND DESIGN PRESSURE (P) = VARIES WITH HEIGHT AND LOCATION EARTHQUAKE DESIGN DATA SHORT PERIOD SPECTRAL RESPONSE (SS) = 0.152 1-SECOND SPECTRAL RESPONSE (S1) = 0.083 SEISMIC IMPORTANCE FACTOR (IE) = 1.0 RISK CATEGORY = II SITE CLASSIFICATION = D SEISMIC DESIGN CATEGORY =C SHORT PERIOD SPECTRAL RESPONSE (SDS) = 0.163 1-SECOND SPECTRAL RESPONSE (SD1) = 0.134 BASIC STRUCTURAL SYSTEM / SEISMIC RESISTING SYSTEM: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE / ORDINARY REINFORCED MASONRY SHEAR WALLS ANALYSIS PROCEDURE UTILIZED = EQUIVALENT LATERAL FORCE PROCEDURE RESPONSE MODIFICATION COEFFICIENT (R) = 3.0 / 2.0 SEISMIC RESPONSE COEFFICIENT (CS) = 0.054 / 0.081 LATERAL LOAD RESISTING SYSTEM LATERAL FORCE RESISTANCE IN THE COMPLETED STRUCTURE IS PROVIDED AS FOLLOWS: ELEVATED FLOOR SLABS AND ROOF SLABS / DECKS SERVE AS HORIZONTAL DIAPHRAGMS TO TRANSFER LATERAL LOADS TO THE VERTICAL LATERAL LOAD RESISTING ELEMENTS WHICH IN TURN TRANSFER THOSE LOADS TO THE FOUNDATION SYSTEM. VERTICAL LATERAL LOAD RESISTING ELEMENTS ARE INDICATED ON THE DRAWINGS AND CONSIST OF THE FOLLOWING, UNLESS NOTED OTHERWISE: PLAN NORTH-SOUTH DIRECTION: REINFORCED MASONRY SHEAR WALLS PLAN EAST-WEST DIRECTION: STEEL BRACED FRAMES SERVICEABILITY LIMITS LIVE LOAD DEFLECTION: SPAN/360 UNO TOTAL LOAD DEFLECTION: SPAN/240 UNO EXTERIOR EDGE BEAMS LIVE LOAD DEFLECTION: SPAN/480 OR 1/2 INCH, UNO EXTERIOR EDGE BEAMS TOTAL LOAD DEFLECTION: SPAN/360 OR 1 INCH, UNOLOADS SUSPENDED FROM STRUCTURE UNLESS SPECIFICALLY NOTED OTHERWISE, THE UNIFORM MEP/CEILING LOADING ALLOWANCE SUSPENDED FROM FLOOR AND ROOF STRUCTURES SHALL BE 10 PSF. CONTRACTOR SHALL COORDINATE AND PROVIDE SUFFICIENT SUPPORT FRAMING FOR ITEMS SUSPENDED FROM THE STRUCTURE (DUCTWORK, PIPING, CONDUIT, LIGHTS, CEILINGS, ETC.) TO DISTRIBUTE LOADING THROUGHOUT THE STRUCTURE SUCH THAT THE DESIGN SUPERIMPOSED LOAD ALLOWANCE IDENTIFIED IS NOT EXCEEDED FOR ANY STRUCTURAL ELEMENT. IF THE CONTRACTOR DETERMINES THAT LOADS SUSPENDED WILL EXCEED THE IDENTIFIED LOADING LIMITS FOR ANY STRUCTURAL ELEMENT, THE CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO INSTALLING THE LOADS. LOADS SUSPENDED FROM HANGER TABS ON COMPOSITE STEEL FLOOR DECK SHALL NOT EXCEED 50 LBS AT ANY SINGLE LOCATION. LOADS SHALL NOT BE SUSPENDED FROM STEEL ROOF DECK. LOADS IMPOSED ON STRUCTURE LOADS IMPOSED ON THE STRUCTURE BY EQUIPMENT AND SYSTEMS (INCLUDING BUT NOT LIMITED TO, ARCHITECTURAL PRECAST CONCRETE, CURTAIN WALL, CLADDING, STAIRS, ELEVATORS, ESCALATORS, MEP EQUIPMENT, DUCTWORK, CONDUIT, LIGHTS, CEILINGS, ETC.) SHALL IMPART ONLY VERTICAL AND HORIZONTAL LOADS ON THE STRUCTURE WITHOUT INDUCING TORSIONAL LOADS ON THE SUPPORTING STRUCTURAL ELEMENTS, UNLESS SPECIFICALLY INDICATED OTHERWISE. THE CONTRACTOR IS RESPONSIBLE FOR DESIGNING (BY THE CONTRACTOR'S PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS CONSTRUCTED), SUPPLYING, AND INSTALLING ALL NECESSARY SUPPLEMENTAL BRACING, KICKERS, RELATED CONNECTIONS, ETC., AS REQUIRED TO PREVENT APPLYING TORSIONAL LOAD TO THE SUPPORTING STRUCTURE. DESIGN CALCULATIONS AND DETAILS, SIGNED AND SEALED BY THE CONTRACTOR'S LICENSED PROFESSIONAL ENGINEER, FOR ALL SUPPLEMENTAL MATERIALS AND CONNECTIONS UTILIZED TO PREVENT APPLYING TORSIONAL LOAD TO THE STRUCTURE, SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION.EXPANSION ANCHORS EXPANSION ANCHORS SHALL BE HILTI “KWIK BOLT TZ”OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. ANCHOR FINISH SHALL BE CARBON STEEL FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER’S REPRESENTATIVE. ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH. ADHESIVE ANCHORS FOR SOLID SUBSTRATES (THREADED ROD AND REBAR) ADHESIVE ANCHORS FOR SOLID SUBSTRATES SHALL BE HILTI "HIT-HY 200" OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. THREADED ANCHORS SHALL BE ASTM A36 RODS FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH. ADDITIONALLY, ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY WITH AN AGE OF LESS THAN 21 DAYS. MINIMUM EMBEDMENT DEPTH SHALL BE 8 DIAMETERS UNLESS NOTED OTHERWISE. ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES SHALL BE HILTI "HIT-HY 270" WITH HILTI “HIT-SC”SCREEN TUBE OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. ANCHORS SHALL BE ASTM A36 THREADED RODS FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. CONCRETE UNIT MASONRY CONCRETE MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CODE-REFERENCED EDITION OF BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 402/602). CONCRETE MASONRY SHALL CONSIST OF HOLLOW UNITS CONFORMING TO THE REQUIREMENTS OF ASTM C90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 2,800 PSI, UNO. CONCRETE MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'M) OF 2,000 PSI AT 28 DAYS, UNO. ALL MASONRY TO BE LAID IN RUNNING BOND, UNO. ALIGN CELLS TO ALLOW PROPER REINFORCEMENT PLACEMENT AND GROUTING. MORTAR SHALL BE TYPE S PROPORTIONED IN ACCORDANCE WITH ASTM C270. FULLY MORTAR FACE SHELLS ON HEAD AND BED JOINTS. PROVIDE FULL MORTAR COVER ON ALL WEBS AT GROUTED CELLS. GROUT FOR REINFORCED MASONRY SHALL BE PROPORTIONED IN ACCORDANCE WITH ASTM C476 (MINIMUM 28-DAY COMPRESSIVE STRENGTH = 2,000 PSI, UNO). COARSE AND FINE AGGREGATES SHALL CONFORM TO ASTM C404. USE COARSE GROUT FOR ALL GROUTING EXCEPT HIGH-LIFT POURS DEFINED BY ACI 530, WHERE FINE GROUT SHALL BE USED. GROUT SOLID ALL CELLS WITH REINFORCEMENT. GROUT SOLID ALL CELLS AT BELOW-GRADE CMU IN CONTACT WITH SOIL. PROVIDE 9-GAUGE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY CONSTRUCTION. REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED EIGHT INCHES AT SPLICES. CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS. SPACE REINFORCEMENT AT 8" ON CENTER FOR PARAPETS AND BELOW GROUND FLOOR ELEVATION. ELSEWHERE SPACE REINFORCEMENT AT 16 INCHES ON CENTER, UNLESS NOTED OTHERWISE. BEAMS AND LINTELS SHALL BEAR A MINIMUM OF 8 INCHES ONTO SUPPORTING MASONRY, UNLESS NOTED OTHERWISE. BEARING FOR ALL BEAMS, LINTELS, JOISTS, ETC. SHALL BE GROUTED SOLID A MINIMUM OF ONE COURSE (8 INCHES) BELOW BEARING ELEVATION, UNLESS NOTED OTHERWISE. PROVIDE MASONRY CONTROL JOINTS AT 25'-0" OC MAXIMUM, UNO. LOCATE JOINTS IN ACCORDANCE WITH NCMA TEK 10-2C "CONTROL JOINTS FOR CONCRETE MASONRY WALLS - EMPIRICAL METHOD" AT OFFSETS, SETBACKS, WALL INTERSECTIONS, CORNERS, CHANGES IN THICKNESS, CHANGES IN HEIGHT, OR EDGE OF OPENINGS. REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21