HomeMy WebLinkAbout2021-07-02 Artistic Pallets Architectural Addendum 2B2
B3
B6
B1 B1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
B
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL TRACK
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL
METAL DEFLECTION TRACK
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA2 -7/8"
3 -3/4"
4 -7/8"
7 -1/4"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
B2S
B3S
B6S
B8
9 -1/4"8"
B8S
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA
WALL TYPE SYMBOL
STRUCTURAL CORE SIZE
Y6S
WALL TYPE DESIGNATION
ACOUSTICAL ATTENUATION REQ'D
REFERENCE A001 FOR WALL TYPE DESCRIPTIONS
A. ALL WALLS ARE TO BE TYPE 'B3S' U.N.O.
B. PARTITION SYMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN PROVIDED FOR AREA.
C. REFER TO FINISH PLANS FOR WALL FINISH, BASE, AND CEILING INFORMATION.
D. REFER TO WALL SECTIONS FOR EXTERIOR WALL CONSTRUCTION.
E. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH PLUMBING FIXTURES AND
WITHIN 4'-0 OF DRINKING FOUNTAINS / WATER COOLERS, U.N.O.
F. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND ABOVE CEILINGS.
G. PROVIDE FIRE RESISTIVE RATED GYPSUM WALL BOARD AT ALL RATED ASSEMBLIES TO
MEET ASSEMBLY REQUIREMENTS.
H. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL RATING AT ALL PENETRATIONS
AND AT HEAD/FLOOR INTERSECTIONS WITH RATED ASSEMBLIES.
I. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD, PENETRATIONS, AND ADDITIONAL
SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED WALLS.
J. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS SCHEDULED TO HAVE CERAMIC
TILE.
K. FRAME DOOR OPENINGS 4" FROM FACE OF PERPENDICULAR WALL ON HINGE SIDE AND
1'-6" MIN. FROM FACE OF PERP. WALL ON LATCH SIDE, UNLESS NOTED OTHERWISE.
L. PROVIDE GYPSUM BOARD CONTROL JOINTS AND MASONRY CONTROL JOINTS AT WALLS
OVER 30'-0 IN LENGTH. LOCATE ABOVE EDGE OF OPENING WHEN POSSIBLE.
M. AT FIRE RATED WALLS WHERE OPENINGS ARE GREATER THAN 16 SQUARE INCHES OR
WHERE TOTAL AREA OF OPENINGS EXCEEDS 100 SQUARE INCHES IN 100 SQUARE FEET,
WRAP 5/8 TYPE 'X' GYPSUM BOARD BEHIND OPENINGS PER U.L. DESIGN #U510.
N. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT
TRANSFER OF VERTICAL LOADS INTO PARTITION WHILE PROVIDING LATERAL SUPPORT
REQUIRED VIA USE OF DOUBLE TRACK TYPE (SECONDARY TRACK SET INSIDE DEEP-LEG
TRACK) OR SLOTTED TRACK TYPE, EACH ALLOWING VERTICAL MOVEMENT OF THE
STRUCTURE, PREVENTING ROTATION OF STUDS BUT MAINTAINING STRUCTURAL
PERFORMANCE OF PARTITION.
O. LINE OF STRUCTURE INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES
NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.
P. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE RESISTANT FILL MATERIAL
IN CONJUNCTION WITH AN APPROPRIATE RATED FIRESTOPPING SYTEM.
Q. NON-RATED PARTITIONS SHALL USE ACOUSTICAL SEALANT.
R. PROVIDE SHEET METAL OR FIRE RETARDANT WOOD BLOCKING IN WALL CAVITIES FOR
ITEMS THAT ARE REQUIRED TO BE SECURED TO THE WALLS. REFERENCE MECHANICAL,
PLUMBING, ELECTRICAL AND TECHNOLOGY DRAWINGS. COORDINATE WITH FURNITURE
SUPPLIER WHERE APPROPRIATE.
S. TAPE AND SPACKLE ALL PENETRATIONS IN GYPSUM BOARD PARTITIONS, INCLUDING, BUT
NOT LIMITED TO WATER LINES, DRAINS, CONDUIT, THERMOSTATS, ETC. INSTALL FIRE
RETARDANT SEALANT AT PENETRATIONS IN RATED PARTITIONS AS REQUIRED.
T. ALL CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT UNITS LAID IN RUNNING
BOND UNLESS NOTED OTHERWISE.
U. ALL CMU WALLS SHALL EXTEND TO 4" MINIMUM ABOVE HIGHEST ADJACENT CEILING U.N.O.
V. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION (S), EXTEND ATTENUATION
TO FULL HEIGHT OF PARTITION U.N.O. FLOOR TRACK TO BE SET IN A CONTINUOUS BED
OF SEALANT.
W. IN AREAS DESIGNATED TO HAVE A RATED CEILING, BUILD WALLS THAT ARE NOT
INDICATED TO GO TO DECK TO UNDERSIDE OF RATED CEILING.
X. ALTHOUGH WALL STUD SIZE / SPACING ARE LISTED, CONTRACTOR WILL VERIFY AND
PROVIDE APPROPRIATE SIZE / GAGE / SPACING OF STUDS REQUIRED FOR CONDITIONS
INDICATED AND NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO FABRICATION /
INSTALLATION.
RATING PRIORITY
3 HOUR ASSEMBLY 1
2 HOUR ASSEMBLY 2
1 HOUR ASSEMBLY 3
SMOKE RATED ASSEMBLY 4
NON RATED ASSEMBLY 5
(LOWER NUMBER, HIGHER PRIORITY)
HIGHER PRIORITY PARTITION
GYPSUM BOARD CONTINUES
THROUGH STUD CAVITY OF
LOWER WALL
LOWER PRIORITY PARTITION
HIGHER PRIORITY
CEILING/ROOF ASSEMBLY
LOWER PRIORITY PARTITIONGYPSUM BOARD CONTINUES
PAST TOP OF LOWER WALL
G2
G3
G6
G1 G1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
G
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL TRACK
SEALANT AND BACKER ROD; ONE SIDE, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL.
METAL TRACK
LINE OF
STRUCTURE
UNDERSIDE
OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 -1/4"
3 -1/8"
4 -1/4"
6 -5/8"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
G2S
G3S
G6S
G8
NON-
RATED NA 8 -5/8"8"
G8S
SEALANT AND BACKER ROD; ONE SIDE, CONT.
M4
M6
M8
WALL PARTITION TYPE PLAN VIEW SECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
M
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
CMU
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
CMU
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
5 -5/8"
3 -5/8"
STC:
NO SOUND
WITH SOUND
M4S
M6S
M8S
M12
NON-
RATED NA
M12S SECTION VIEW7 -5/8"
11 -5/8"
5 -5/8"
3 -5/8"
7 -5/8"
11 -5/8"
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/2/2021 1:55:37 PMA000
WALL TYPES
2021.00173
05/20/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS -PHASE 2
4518 WEST 99TH
STREET CARMEL, IN
46032
INTERIOR PARTITION LEGEND
GENERAL PARTITION NOTES
RATED WALL PRIORITY
REVISION SCHEDULE
NO. DESCRIPTION DATE
2 ADDENDUM 2 07/02/2021
2
09/16/21
1 2 3 4 5
OFFICE
113
OFFICE
114
WOMEN'S RR
134
WOMEN'S RR
105
OFFICE
107
OFFICE
111
BREAK
110
IT
106
VEST
120
BREAK
ROOM
121
MEN'S
RESTROOM
123
WOMEN'S
RESTROOM
124
OFFICE
108
MEN'S RR
109
CONFERENCE
104
OFFICE
115
STOR.
112
RECEPTION
103
LOBBY
102
VEST.
101
STAIR
ST-1
JAN.
125
OPEN
OFFICE/WORKROOM
122
124
125
123
121120-2
122-2
122-1
1
W1
W1
W1
W1
W1
10/A401
A401
1
3' - 9 5/8"3' - 0" 18' - 0" 3' - 0"2' - 8"5' - 5 1/4"14' - 9 3/4" 8' - 10 3/4" 16' - 1 1/2"
5' - 4 1/4" 3' - 4"B6S
B6S
B3S
B3S
B6S
G3
G3
G3
1
120-1 46' - 9 3/4" 9' - 0" 27' - 10"3' - 0"6' - 0"3' - 0"6' - 0" 3' - 0" 1' - 9"6' - 10 1/4" 1' - 4"2' - 10 3/4"3
11/A4014
4
5
122-3
M8
M8
M8
6
7
8 9
2
2
2
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/2/2021 1:55:39 PMA101
FIRST FLOOR
ARCHITECTURAL
PLAN
2021.00173
05/20/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS -PHASE 2
4518 WEST 99TH
STREET CARMEL, IN
46032
N
3/32" = 1'-0"A101
1 FIRST FLOOR ARCHITECTURAL PLAN
KEYED FLOOR PLAN NOTES (NOTED WITH )1
1 ALIGN FINISHED FACE OF EXISTING WALL WITH FINISHED FACE OF
NEW WALL.
2 NEW FIXED LADDER SECURED TO FLOOR UP TO EXISTING TO REMAIN
ROOF ACCESS.
3 OWNER FURNISHED OWNER INSTALLED LOCKERS.
4 UTILITY SINK. REFER TO PLUMBING DRAWINGS.
5 MOP SINK. REFER TO PLUMBING DRAWINGS.
6 EXISTING TO REMAIN REFRIGERATOR.
7 OWNER FURNISHED VENDING MACHINES.
8 OWNER FURNISHED WATER DISPENSER.
9 STEEL STAIR AND RAILING. REFER TO STRUCTURAL DRAWINGS.
REVISION SCHEDULE
NO. DESCRIPTION DATE
1 ADDENDUM 1 05/20/2021
2 ADDENDUM 2 07/02/2021
1
09/16/21