HomeMy WebLinkAbout2021-07-02 Artistic Pallets Structural Addendum 2STEEL BEAM LEGEND (ASD) W18X40 C=1" CAMBERBEAM SIZE 20K20K BEAM REACTION, TYP (20) QUANTITY OF SHEAR STUDS, UNIFORMLY SPACED BETWEEN SUPPORTS, UNO "(MIN)" = STUDS @ 24" OC FOR FULL BEAM LENGTHNOTES: 1) REACTION VALUE IS ASD (KIPS), UNO. 2) WHERE NO VALUE IS SHOWN, DESIGN CONNECTION FOR A MINIMUM REACTION OF 16 KIPS. 3) POSITIVE CAMBER UPWARDS, NEGATIVE CAMBER DOWNWARDS. CAMBER SHOWN ON CANTILEVERS IS AT END OF CANTILEVER. 4) BEAMS ARE PRIMARY MEMBERS FOR FIREPROOFING UNLESS NOTED AS SECONDARY. 5) "M" IN PLACE OF BEAM SIZE INDICATES W10X12. 6) LATERAL FORCE TO BE TRANSFERRED THROUGH SUPPORT BY CONNECTIONS IN ADDITION TO VERTICAL REACTION FORCES. FORCE MAY ACT IN EITHER DIRECTION. FORCE IS GREATER OF 0.6W OR 0.7E, UNO. MOMENT CONNECTION CANT BM, SAME SIZE AND END REACTION AS BACKSPAN, UNO C=1/2" CAMBER ##K NOTE 6 MISCELLANEOUS SYMBOLS NORTH ARROW GRIDLINES SOIL SECTION NUMBER SHEET NUMBER 1 S101 1 S101 CALLOUT NUMBER SHEET NUMBER A 1 ELEVATION REFERENCE LIMIT OF EXTENT CONTINUOUS EXTENT C# COLUMN NOTATION Z# PRECAST/ BRICK SUPPORT L# LINTEL NOTATION F ## COLUMN FOOTING NOTATION GB ## GRADE BEAM NOTATION P ## PIER NOTATION B ## CONCRETE BEAM NOTATION PB ## POST-TENSIONED CONCRETE BEAM NOTATION PC ## PILE CAP NOTATION WF ## WALL FOOTING NOTATION SHEAR WALL NOTATIONSW ## BW ## BEARING WALL NOTATION GRANULAR FILL Name Elevation WALL PIER NOTATIONWP ## W ## WALL NOTATION N TS ## THICKENED SLAB NOTATION # KEYED PLAN NOTE CONCRETE SYMBOLS POST-TENSION TENDON ANCHOR DEAD END LOCATION POST-TENSION TENDON ANCHOR JACKING LOCATION REBAR CHANGE OF SLAB ELEVATION SLOPING SLAB CHANGE OF SLAB THICKNESS MECHANICAL COUPLER REBAR SPLICELIMIT OF MEMBER OR SPAN MARK DIRECTION OF SPAN OPENING SELF-EXPANDING WATERSTOP JOINT LOCATION IN CONCRETE WALLS REBAR TERMINATOR INTENTIONALLY ROUGHENED CONSTRUCTION JOINT TO 1/4" AMPLITUDE WELDED WIRE REINFORCING PVC WATERSTOP COLUMN CONTINUES COLUMN TERMINATED FORM-SAVER SLAB ON GRADE MARK SOG# WALL FOOTING OR THICKENED SLAB WF# / TS# F# ISOLATED FOOTING CONNECTORS HEADED STUD CONNECTOR SECTION END/ALT VIEW CAST-IN ANCHOR ROD POST-INSTALLED MECHANICAL ANCHOR BOLT POST INSTALLED ADHESIVE ANCHOR STEEL MEMBERS W-SHAPE BEAM SHAPE SECTION PLAN VIEWELEVATION CHANNEL ANGLE DOUBLE ANGLE HOLLOW STRUCTURAL SECTION -RECTANGULAR LLV LLH HOLLOW STRUCTURAL SECTION -CIRCULAR (PIPE) OPEN WEB STEEL JOIST STEEL SYMBOLS STEEL DECK STEEL DECK MARK AND SPAN DIRECTION BEAM SPLICE CONNECTION BEAM MOMENT CONNECTION AT COLUMN BEAM SHEAR CONNECTION AT COLUMN BEAM CONTINUOUS OVER COLUMN SLAB ON STEEL DECK SLAB ON STEEL DECK WWR COLUMN STARTS HERE HANGER OR POST HANGER OR POST BELOW FLOOR SLAB-ON-DECK MARK AND SPAN DIRECTION OR D# S# C# COLUMN MARK SIDE PLATE CONNECTION AT COLUMN MASONRY MEMBERS CMU SECTION CMU BOND BEAM SECTION (FULLY GROUTED) CMU LINTEL SECTION (FULLY GROUTED) SINGLE REINFORCEMENT (FULLY GROUT REINFORCED CELLS) DOUBLE REINFORCEMENT (FULLY GROUT REINFORCED CELLS) PLAN PLAN PLAN PLAN NON-LOAD BEARING CMU WALL LOAD BEARING/SHEARWALL STEEL JOIST AND JOIST GIRDER SUPPLEMENTAL LOAD LEGEND JOIST GIRDER (##K) ADDITIONAL VERT LOAD AT INDICATED JOIST GIRDER PANEL POINT NOTES: 1) VERTICAL LOAD IS ASD LIVE LOAD (KIPS), UNO. 2) VERTICAL LOAD IS IN ADDITION TO TYPICAL PANEL POINT LOADS, UNO. 3) LATERAL FORCE TO BE TRANSFERRED THROUGH SUPPORT BY CONNECTIONS, IN ADDITION TO VERTICAL REACTION FORCES. FORCE MAY ACT IN EITHER DIRECTION. FORCE IS GREATER OF 0.6W OR 0.7E, UNO. 4) TOP CHORD AXIAL FORCE IN ADDITION TO CHORD FORCES PRODUCED BY VERTICAL LOADS. FORCE MAY BE EITHER COMPRESSION OR TENSION. FORCE IS GREATER OF 0.6W OR 0.7E, UNO. 5) "SP" INDICATES SPECIAL LOADING CONDITION. REFER TO LOAD MAPS, FRAMING PLANS AND DETAILS FOR LOADING INFORMATION. ##K JOIST, TYP<##K>NOTE 3 NOTE 4 ##K ADDITIONAL VERT LOAD ON JOIST JST JOIST JT JOINT KB KNEE BRACE KIP, K 1,000 POUNDS KO KNOCK-OUT KSI KIPS PER SQUARE INCH L ANGLE OR LENGTH LAB LABORATORY LB POUND LF LINEAL FOOT LIN LINEAL, LINEAR LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONGIT LONGITUDINAL LP LOW POINT LSL LAMINATED STRAND LUMBER LSLT LONG SLOTTED HOLE LTWT LIGHT WEIGHT LVL LAMINATED VENEER LUMBER MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MC MISCELLANEOUS CHANNEL MECH MECHANICAL MEMB MEMBRANE MEP MECHANICAL/ ELECTRICAL/ PLUMBING MF MOMENT FRAME MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MULT MULTIPLE N/A NOT APPLICABLE NO NUMBER NOM NOMINAL NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFD OVERFLOW DRAIN OH OVERHEAD OPNG OPENING OPP OPPOSITE OPPHD OPPOSITE HAND ORIG ORIGINAL OVS OVERSIZED HOLE OWJ PRE-MANUFACTURED OPEN WEB JOIST PAF POWDER ACTUATED FASTENER PC PRECAST CONCRETE PEMB PRE-ENGINEERED METAL BUILDING PERIM PERIMETER PERM PERMANENT PERP PERPENDICULAR PJP PARTIAL JOINT PENETRATION PL PLATE PLF POUNDS PER LINEAL FOOT PLYWD PLYWOOD PREFAB PREFABRICATED PRELIM PRELIMINARY PREP PREPARATION, PREPARE PROJ PROJECTION PS PRESTRESSED PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT POST-TENSIONED R RADIUS RD ROOF DRAIN REF REFERENCE REINF REINFORCEMENT, REINFORCE REQD REQUIRED RO ROUGH OPENING RTU ROOFTOP MECHANICAL UNIT S SLOPE SCHED SCHEDULE SECT SECTION SF SQUARE FEET SHT SHEET SIM SIMILAR SOG SLAB-ON-GRADE SOMD SLAB ON METAL DECK SPA SPACES, SPACE SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL SSLT SHORT SLOTTED HOLE STD STANDARD STIFF STIFFENER STL STEEL STRUC STRUCTURAL SYM SYMMETRICAL T & B TOP AND BOTTOM T/ TOP OF T/GB TOP OF GRADE BEAM TBS MECHANICAL TENSION BUTT SPLICE TC TOP CHORD TEMP TEMPERATURE THRU THROUGH TJI PREFABRICATED WOOD I-JOIST TRANS TRANSVERSE TYP TYPICAL UL UNDERWRITERS' LABORATORY INC. UNO UNLESS NOTED OTHERWISE UT ULTRA-SONIC TEST VERT VERTICAL W WIDE FLANGE W/ WITH W/O WITHOUT WD WOOD WH WEEP HOLE WP WORK POINT WT WEIGHT, STRUCTURAL T WWF, WWR WELDED WIRE REINFORCEMENT XS EXTRA STRONG (PIPE) XXS DOUBLE EXTRA STRONG (PIPE) & AND A/E ARCHITECT/ENGINEER ACI AMERICAN CONCRETE INSTITUTE ADDL ADDITIONAL ADJ ADJACENT AGGR AGGREGATE AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APA AMERICAN PLYWOOD ASSOCIATION APPROX APPROXIMATE AR ANCHOR ROD ARCH ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY B/ BOTTOM OF BAL BALANCE BC BOTTOM CHORD BD BOARD BF BRACED FRAME BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BOT BOTTOM BRG BEARING BRKT BRACKET BTWN BETWEEN BU BUILT UP C STANDARD CHANNEL CANT CANTILEVER CC CENTER TO CENTER CF COLD FORMED CG CENTER OF GRAVITY CIP CAST-IN-PLACE CJ CONTROL, CONTRACTION OR CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLR CLEARANCE, CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTR CENTER CTRD CENTERED CU FT CUBIC FEET CU IN CUBIC INCH CYD CUBIC YARD DBA DEFORMED BAR ANCHOR DBL DOUBLE DEG DEGREE DEMO DEMOLITION, DEMOLISH DEPT DEPARTMENT DET DETAIL DIA DIAMETER DIAG DIAGONAL DIAPH DIAPHRAGM DIM DIMENSION DN DOWN DO DITTO DP DEEP DWG DRAWING DWL DOWELS EA EACH EF EACH FACE EJ EXPANSION JOINT EL, ELEV ELEVATION ELEC ELECTRICAL ENCL ENCLOSURE ENGR ENGINEER EOD EDGE OF DECK EOJ EDGE OF JOIST EOS EDGE OF SLAB EQ EQUAL EQPT EQUIPMENT ES EACH SIDE EW EACH WAY EX EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FIN FINISH FLG FLANGE FLR FLOOR FS FAR SIDE FT FEET FTG FOOTING FTGD FOOTING DRAIN FV FIELD VERIFY GA GAUGE GALV GALVANIZED GB GRADE BEAM GL GLUED LAMINATED TIMBER (GLULAM) GRND GROUND GT GIRDER TRUSS HAS HEADED ANCHOR STUD HORIZ HORIZONTAL HP HIGH POINT HSS HOLLOW STRUCTURAL SECTION HT HIP TRUSS HVAC HEATING, VENTILATION, AIR CONDITIONING ID INSIDE DIAMETER IF INSIDE FACE IN INCH INCL INCLUDE INFO INFORMATION INSUL INSULATION INT INTERIOR J/BRG JOIST BEARING STRUCTURAL DRAWINGS ABBREVIATIONS SHEET # SHEET NAME S001 ABBREVIATIONS AND SYMBOLS S002 GENERAL NOTES S003 GENERAL NOTES S004 LOAD MAPS S101 DEMOLITION AND FOUNDATION PLANS S102 MEZZANINE AND ROOF FRAMING PLANS S301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS S302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS S303 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS S401 CMU SCHEDULES, SECTIONS AND DETAILS S501 STEEL SCHEDULES, SECTIONS, AND DETAILS S502 STEEL SCHEDULES, SECTIONS, AND DETAILS S503 STEEL COLUMN SCHEDULE AND BASE PLATE DETAILS S504 BRACED FRAME ELEVATIONS AND DETAILS STRUCTURAL INDEX Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:56 PMS001 ABBREVIATIONS AND SYMBOLS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 GENERAL STRUCTURES INDICATED ON THESE DRAWINGS HAVE BEEN DESIGNED FOR THE IN- SERVICE LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURES ARE DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE CONSTRUCTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE STRUCTURES AND RELATED COMPONENTS DURING CONSTRUCTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, TIEDOWNS, ETC. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT CONSTRUCTION LOADS DO NOT EXCEED THE CAPACITY OF ANY STRUCTURAL ELEMENT AT THE TIME THE LOADS ARE APPLIED, INCLUDING BUT NOT LIMITED TO: WEIGHTS OF MATERIALS, WEIGHTS OF EQUIPMENT AND WORKERS, AND ALL LOADS APPLIED FROM TEMPORARY LIFTS, HOISTS AND CRANES, ETC. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS AND SPECIFICATIONS OF ALL OTHER DISCIPLINES, TRADES, AND DELEGATED DESIGN ELEMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE STRUCTURAL WORK WITH ALL OTHER APPLICABLE TRADES. THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT. DO NOT SCALE THE DRAWINGS. REFER TO THE WRITTEN DIMENSIONS AND INFORMATION. IF A DISCREPANCY IS NOTED ON THE DRAWINGS, GENERAL NOTES, OR SPECIFICATIONS, THE CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER A WRITTEN REQUEST FOR CLARIFICATION AND SHALL NOT PROCEED WITH THE AFFECTED WORK WITHOUT DOCUMENTED RESOLUTION OF THE DISCREPANCY. ALL COSTS RESULTING FROM THE CONTRACTOR IMPROPERLY PROCEEDING WITH THE AFFECTED WORK PRIOR TO DOCUMENTED RESOLUTION OF THE DISCREPANCY, INCLUDING COST OF REMOVAL AND REPLACEMENT OF NON-CONFORMING WORK, SHALL BE BORNE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. CONCRETE MIX DESIGN SUBMITTAL THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETE OTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING INFORMATION: 1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT. 2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER. 3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF SUPPLIER. 4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER. 5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER. 6. MIXING WATER PROPORTION AND SOURCE. 7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S). 8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME. 9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C). 10. DESIGN SLUMP RANGE. 11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR). 12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD DEVIATION" DETERMINATION OUTLINED IN ACI 318. PRODUCT DATA SUBMITTALS THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. SUBMIT HARD COPIES OR ELECTRONIC VERSIONS OF PRODUCT DATA. FOR HARD COPY OPTION, SUBMIT A MINIMUM OF TWO COPIES OF PRODUCT DATA TO THE STRUCTURAL ENGINEER FOR REVIEW (ONE COPY SHALL BE RETAINED BY THE STRUCTURAL ENGINEER). FOR ELECTRONIC OPTION, SUBMIT PRODUCT DATA IN ADOBE PDF FORMAT. 1. FIBER REINFORCEMENT FOR CONCRETE 2. CONCRETE CURING COMPOUND 3. CONCRETE JOINT SEALANT 4. MASONRY JOINT REINFORCEMENT 5. EXPANSION ANCHORS 6. ADHESIVE ANCHORS 7. NON-SHRINK GROUT 8. HELICAL PILES RENOVATION (EXISTING CONDITIONS) INFORMATION SHOWN FOR THE EXISTING STRUCTURE ON THESE DRAWINGS WAS TAKEN FROM DRAWINGS THAT WERE PREPARED FOR SCHAFER POWDER COATING, PREPARED BY STRUCTURAL DESIGN INC, ENTITLED NEW FACILITY FOR: SCHAFER POWDER COATING, DATED 04-10-06. WORK SHOWN ON THESE PLANS ASSUMES THAT THE ORIGINAL CONSTRUCTION WAS PERFORMED IN ACCORDANCE WITH THE ABOVE INDICATED ORIGINAL DRAWINGS INCLUDING (BUT NOT LIMITED TO) DIMENSIONS, ELEVATIONS, MEMBER SIZES, MATERIALS, DETAILS, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS RELATING TO THE EXISTING STRUCTURE AND TO NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF DEMOLITION REQUIRED TO COMPLETE THE WORK, INCLUDING MAINTAINING THE SAFETY AND INTEGRITY OF THE EXISTING STRUCTURE. DEMOLISHED MATERIALS SHALL BE DISPOSED OF SAFELY AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS AND ALL APPLICABLE LAWS, CODES AND REGULATIONS. WHERE ELEMENTS ARE INDICATED TO BE CUT AND REMOVED, DO NOT CUT BEYOND THE EXTENTS OF THE ELEMENTS INDICATED TO BE REMOVED AND DO NOT EXTEND CUTS INTO ELEMENTS THAT ARE TO REMAIN. WHERE NEW WORK IS TO BE FITTED TO OLD WORK, THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND CONDITIONS IN THE FIELD, AND REPORT ANY ERRORS OR DISCREPANCIES TO THE STRUCTURAL ENGINEER PRIOR TO THE FABRICATION AND ERECTION OF ANY NEW MEMBERS. EXISTING MATERIALS TO BE REMOVED AND REINSTALLED AS PART OF THIS PROJECT, THAT BECOME DAMAGED, SHALL BE REPLACED WITH NEW MATERIAL OF EQUAL QUALITY AND APPEARANCE, AT THE CONTRACTOR'S EXPENSE. ALL WORK SHALL BE PERFORMED WITHOUT DAMAGE OR DISRUPTION TO ADJACENT RETAINED WORK. ADJACENT EXISTING CONSTRUCTION SHALL BE PROTECTED FROM DUST, DIRT AND DEBRIS ACCUMULATION AT ALL TIMES. FOUNDATIONS FOUNDATIONS HAVE BEEN DESIGNED BASED ON ASSUMED ALLOWABLE SOIL BEARING PRESSURES INDICATED BELOW. CONTRACTOR SHALL ENGAGE A LICENSED GEOTECHNICAL ENGINEER TO REVIEW THE SOIL CONDITIONS AT THE SITE AS NECESSARY TO CONFIRM THE ALLOWABLE BEARING PRESSURES PRIOR TO PLACEMENT OF THE FOUNDATIONS. CONFIRMATION OF THE ACCEPTABILITY OF THE SOILS SHALL BE REPORTED IN WRITING TO THE STRUCTURAL ENGINEER. IF ACTUAL ALLOWABLE PRESSURES ARE FOUND TO BE LESS THAN THE ASSUMED VALUES, THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH FOUNDATION CONSTRUCTION WITHOUT REVIEW BY THE STRUCTURAL ENGINEER. DESIGN NET SOIL PRESSURE: SPREAD FOOTINGS: 1,500 PSF CONTINUOUS WALL FOOTINGS: 1,500 PSF FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS SHALL BE FORWARDED TO THE STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE. FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS ATTEMPTED. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND MAINTAIN APPROPRIATE EXCAVATION PROTECTION, INCLUDING ALL NECESSARY LAYBACKS, SHORING, SHEETING, TIE-BACKS AND OTHER MEASURES AS DETERMINED BY THE CONTRACTOR'S ENGINEER. EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS FOOTINGS AND MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO UNIFORM SURFACE AND SHALL BE PROTECTED AND MAINTAINED UNIFORM UNTIL CONCRETE IS PLACED. FROST DEPTH: 30 INCHES CONCRETE REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318) AND COMMENTARY (ACI 318R). MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301). READY-MIXED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94. IN CASE OF A DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO. FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F. NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33. WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494. AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE CERTIFIED BY THE MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES. CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN 0.1 PERCENT CHLORIDE IONS SHALL NOT BE USED. IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 306R, COLD WEATHER CONCRETING. IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 305R, HOT WEATHER CONCRETING. USE OF JOINTS IN CONCRETE ELEMENTS AT LOCATIONS OTHER THAN THOSE INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE. NORMAL WEIGHT CONCRETE SHALL HAVE THE PROPERTIES AS INDICATED IN THE CONCRETE MIX SCHEDULE AND SPECIFICATIONS. DO NOT INSTALL OR EMBED ALUMINUM ITEMS, INCLUDING BUT NOT LIMITED TO ALUMINUM CONDUIT, INTO OR IN CONTACT WITH CONCRETE. WHERE NEW CONCRETE IS PLACED AGAINST HARDENED/EXISTING CONCRETE, VERIFY SOUNDNESS OF EXISTING CONCRETE AND REMOVE ALL LOOSE MATERIAL, SNOW, ICE, FROST, WATER, SOIL, DEBRIS AND OTHER DETRIMENTAL MATERIALS PRIOR TO PLACEMENT OF NEW CONCRETE. WELDED WIRE REINFORCEMENT WELDED WIRE REINFORCEMENT SHALL BE SMOOTH WIRE FABRIC CONFORMING TO ASTM A1064. REINFORCEMENT SHALL BE SUPPLIED IN FLAT SHEETS AND LAPPED A MINIMUM OF ONE SPACE PLUS 2 INCHES. WELDED WIRE REINFORCEMENT SHALL BE PLACED AS FOLLOWS, UNLESS NOTED OTHERWISE: SLABS ON GRADE: 2" DOWN FROM TOP OF SLAB SLABS ON COMPOSITE DECK: 3/4" DOWN FROM TOP OF SLAB SUPPORT REINFORCEMENT ON NON-METALLIC CHAIRS TO MAINTAIN PROPER POSITION THROUGHOUT CONCRETE PLACEMENT. (NOTE: THE TERM "WELDED WIRE FABRIC," IF USED, IS THE SAME AS "WELDED WIRE REINFORCEMENT.") CONCRETE TESTING MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH DAY'S POUR AND FOR EACH 100 CUBIC YARDS FOR EACH TYPE OF CONCRETE PLACED. EACH SET SHALL INCLUDE ONE SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS (3 SPECIMENS TESTED AT 28 DAYS IF USING 4x8 CYLINDERS) AND ONE SPECIMEN RETAINED IN RESERVE TO BE TESTED AT THE DIRECTION OF THE STRUCTURAL ENGINEER. SPARE CYLINDER MAY BE DISCARDED 90 DAYS AFTER CASTING UNLESS DIRECTED OTHERWISE BY THE STRUCTURAL ENGINEER. THIS SET OF TEST CYLINDERS SHALL BE PROTECTED AGAINST FREEZING. WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES DURING THE COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED. THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO, AND CURED UNDER THE SAME CONDITIONS AS THE BUILDING CONCRETE. SPECIAL CURING BOXES ARE NOT PERMITTED FOR THESE TEST CYLINDERS. FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, READY-MIX SUPPLIER AND CONTRACTOR WITHIN 24 HOURS AFTER TESTING. POTENTIALLY LOW-STRENGTH CONCRETE: CONCRETE WHICH EXHIBITS STRENGTH BASED ON 7-DAY TESTS BELOW 70% OF THE SPECIFIED 28-DAY COMPRESSIVE STRENGTH SHALL BE CONSIDERED DEFECTIVE WORK AND SHALL BE SUBJECT TO REPAIR OR REPLACEMENT BY THE CONTRACTOR AT THE DISCRETION OF THE OWNER AND STRUCTURAL ENGINEER AT NO ADDITIONAL COST TO THE OWNER. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI, UNO. REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING STANDARDS: ACI 301, ACI 315, ACI 318, ACI DETAILING MANUAL (SP66), AND CRSI MANUAL OF STANDARD PRACTICE. THE CONTRACTOR SHALL PROVIDE BAR SUPPORTS AND SPACERS AS REQUIRED TO MAINTAIN PROPER SUPPORT AND POSITIONING OF THE REINFORCING STEEL THROUGHOUT CONCRETE PLACEMENT OPERATIONS. DESIGN OF THE SUPPORT SYSTEM SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS: CONCRETE CAST AGAINST EARTH: 3 INCHES FOUNDATION TOP REINFORCEMENT: 2 INCHES FOUNDATION BOTTOM AND SIDE REINFORCEMENT: 3 INCHES SLAB ON METAL DECK REINFORCEMENT: SEE DETAILS REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR APPROVED BY THE STRUCTURAL ENGINEER. LAP SPLICES SHALL BE TENSION LAPS IN ACCORDANCE WITH SPLICE/EMBEDMENT TABLES, UNO. ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE STANDARD HOOKS, UNLESS NOTED OTHERWISE. PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT CORNERS OF ALL WALLS AND GRADE BEAMS. LAP SPLICE CORNERS BARS WITH STRAIGHT BARS. UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#5 BARS (ONE EACH FACE) AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS. NON-SHRINK GROUT GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED, NON-CORROSIVE, NON-STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA SANDS, SHRINKAGE COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF 5,000 PSI IN 28 DAYS. SEPARATION OF DISSIMILAR METALS DISSIMILAR METALS INCLUDING STRUCTURAL SHAPES, PLATES, CONNECTORS, ETC. SHALL BE ELECTRICALLY ISOLATED TO PREVENT GALVANIC CORROSION VIA NON- CONDUCTIVE WASHERS, SHOULDER WASHERS, GASKETS, COATINGS, OR EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. PENETRATIONS AND EMBEDDED ITEMS CONTRACTOR SHALL COORDINATE WITH ALL AFFECTED TRADES THE REQUIRED SIZES, TYPES, AND LOCATIONS OF ALL EMBEDDED ITEMS IN, AND ALL PENETRATIONS THROUGH, STRUCTURAL ELEMENTS PRIOR TO CONSTRUCTION. NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE MADE WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. NO ITEMS (INCLUDING, BUT NOT LIMITED TO, CONDUIT, PIPING, ETC.), OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE EMBEDDED IN STRUCTURAL ELEMENTS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. ALL EMBEDDED ITEMS IN EXPOSED EXTERIOR CONCRETE SHALL BE GALVANIZED, PLASTIC, OR EPOXY-COATED. DELEGATED DESIGN FOR ALL SUBMITTALS INDICATED AS "DELEGATED DESIGN," THE CONTRACTOR SHALL ENGAGE A SPECIALTY STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED TO DESIGN AND DETAIL THE ITEMS NOTED IN THE STRUCTURAL SUBMITTALS AND SPECIFICATIONS AS A DELEGATED DESIGN. DELEGATED DESIGN CALCULATIONS AND RELATED DRAWINGS SHALL CONTAIN THE FOLLOWING, AS A MINIMUM: 1. COVER PAGE SIGNED AND SEALED BY THE SPECIALTY STRUCTURAL ENGINEER INCLUDING A STATEMENT OF CERTIFICATION THAT THE SUBMITTED CALCULATIONS ARE IN CONFORMANCE WITH THE DESIGN CRITERIA PROVIDED IN THE CONTRACT DOCUMENTS AND THAT THE RELATED SHOP DRAWINGS ARE IN CONFORMANCE WITH THE SUBMITTED CALCULATIONS. 2. TABLE OF CONTENTS, PLACED ON, OR IMMEDIATELY FOLLOWING THE COVER SHEET. 3. SUMMARY OF APPLICABLE CODE CRITERIA, LOAD DATA AND PERFORMANCE CRITERIA AS OUTLINED IN THE CONTRACT DOCUMENTS. 4. CLEAR DEFINITION OF THE LOCATION(S) IN THE STRUCTURE WHERE EACH CALCULATION APPLIES. 5. LOCATION, TYPE, MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE STRUCTURE BY THE DELEGATED DESIGN SYSTEM/COMPONENTS. SUBMITTALS THAT DO NOT CONTAIN THE INFORMATION NOTED ABOVE MAY, AT THE STRUCTURAL ENGINEER'S DISCRETION, BE REJECTED WITHOUT COMMENT. THE STRUCTURAL ENGINEER’S REVIEW OF DELEGATED DESIGN SUBMITTALS WILL BE FOR GENERAL CONFORMANCE WITH THE DESIGN LOADING, DESIGN INTENT AND LOADS IMPOSED. DELEGATED DESIGN CALCULATIONS SHALL BE SUBMITTED PRIOR TO, OR INCLUDED WITH, THE ASSOCIATED SHOP DRAWING SUBMITTAL. DELEGATED DESIGN SHOP DRAWINGS SUBMITTED WITHOUT APPLICABLE REQUIRED CALCULATIONS WILL BE REJECTED. SHOP DRAWING SUBMITTALS THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE ALL PARTS OF THE WORK TO BE FABRICATED AND CONSTRUCTED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK. ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED. PROVIDE ALL SUBMITTALS IN ELECTRONIC PDF FORMAT. WORK REQUIRING SUBMITTALS FOR STRUCTURAL ENGINEER REVIEW SHALL NOT BE STARTED BY THE CONTRACTOR WITHOUT APPROPRIATE REVIEWED SUBMITTALS. WORK PERFORMED BY THE CONTRACTOR PRIOR TO RECEIVING APPROPRIATE REVIEWED SUBMITTALS SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AS DEEMED NECESSARY BY THE STRUCTURAL ENGINEER, AT THE CONTRACTOR'S EXPENSE, AND WITH NO COST TO THE OWNER. SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS: 1. CONCRETE REINFORCEMENT 2. CONCRETE MASONRY REINFORCEMENT (INCLUDING PLANS AND ELEVATIONS FOR EACH WALL INDICATING ALL CMU REINFORCING REQUIREMENTS, INCLUDING SHEAR WALLS) 3. CONCRETE MASONRY CONTROL JOINT LOCATIONS 4. STRUCTURAL STEEL 5. STEEL DECK SUBMIT DELEGATED DESIGN SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS: 1. STRUCTURAL STEEL CONNECTIONS (INCLUDING DESIGN CALCULATIONS AND SUMMARY PAGE FOR CONNECTIONS NOT SPECIFICALLY DETAILED IN THE CONTRACT DRAWINGS) 2. HELICAL PILES OMISSION OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS FROM SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR FURNISHING THESE MATERIALS REGARDLESS OF WHETHER THE SUBMITTALS HAVE BEEN REVIEWED. THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR SIGNIFIES CONTRACTOR’S ACCEPTANCE OF ALL THE INFORMATION SHOWN “AS IS”. CONTRACTOR WILL BE RESPONSIBLE FOR VERIFYING THE ACCURACY AND COMPLETENESS OF THE INFORMATION PROVIDED. ISSUED DRAWINGS AND SPECIFICATIONS TAKE PRECEDENCE OVER ANY ELECTRONIC INFORMATION PROVIDED. ADDENDA, CHANGE ORDERS, SUPPLEMENTAL INSTRUCTIONS ARE NOT NECESSARILY INCLUDED IN THE ELECTRONIC FILES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL CONTRACT DOCUMENTS, INCLUDING LATEST ADDENDA, AND TO DISTRIBUTE TO ALL SUBCONTRACTORS PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS. STRUCTURAL STEEL STRUCTURAL STEEL MEMBERS, BRACING, COMPONENTS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC ALLOWABLE STRESS DESIGN (ASD) UNLESS NOTED OTHERWISE. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION WITH AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, LATEST EDITION WITH AMENDMENTS. STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE SHAPES SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. HOLLOW STRUCTURAL STEEL SECTIONS (SQUARE, RECTANGULAR, AND ROUND TUBES) SHALL CONFORM TO ASTM A500 GRADE C, UNLESS NOTED OTHERWISE. STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B. STRUCTURAL STEEL ROD HANGERS AND BRACING SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE. FABRICATE AND ERECT STEEL FRAMING SO THAT CAMBER IS UPWARD AFTER INSTALLATION. SPLICE MEMBERS ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE DRAWINGS. DO NOT FIELD MODIFY STRUCTURAL STEEL WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. AT STRUCTURAL STEEL AND STEEL JOIST FRAMED ROOFS PROVIDE L4X4X1/4 FRAMED OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR LARGER ALONG ANY SIDE, UNLESS LARGER FRAMING IS INDICATED. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR PENETRATIONS. COORDINATE FRAMED OPENING SIZES AND LOCATIONS WITH THE MECHANICAL AND PLUMBING CONTRACTORS. FLOWABLE FILL WHERE INDICATED ON THE STRUCTURAL DRAWINGS, FLOWABLE FILL SHALL BE A CONTROLLED LOW-STRENGTH MATERIAL (CLSM) PRODUCED AND PLACED IN ACCORDANCE WITH RECOMMENDATIONS OF ACI 229. PROVIDE MATERIAL WITH 28- DAY COMPRESSIVE STRENGTH OF 1,000 PSI UNLESS NOTED OTHERWISE. STRUCTURAL STEEL CONNECTIONS DESIGN CONNECTIONS NOT SHOWN IN ACCORDANCE WITH THE ASD SPECIFICATION AND MANUAL OF STEEL CONSTRUCTION. UNLESS NOTED OTHERWISE ON THE DRAWINGS, DESIGN BEAM CONNECTIONS NOT SHOWN, TO SUPPORT A MINIMUM SHEAR REACTION OF 16 KIPS ASD. PROVIDE NO LESS THAN 2 BOLTS IN ANY VERTICAL ROW OF BOLTS, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS. BOLTS IN STRUCTURAL STEEL JOINTS SHALL CONFORM TO ASTM F3125 AND SHALL BE 3/4" DIAMETER GRADE A325, UNLESS NOTED OTHERWISE. (TWIST-OFF TENSION CONTROL BOLTS, IF USED, SHALL CONFORM TO ASTM F3125 AND SHALL BE 3/4" DIAMETER GRADE F1852, UNLESS NOTED OTHERWISE.) BOLTED CONNECTIONS SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS, APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS. UNLESS NOTED OTHERWISE, BOLTED CONNECTIONS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION, EXCEPT BOLTED CONNECTIONS IN BRACE ELEMENTS ARE TO BE FULLY PRETENSIONED WITH CLASS A FAYING SURFACES. BURNING OF HOLES IN STRUCTURAL STEEL IS EXPLICITLY PROHIBITED UNLESS WRITTEN PERMISSION IS GRANTED BY THE STRUCTURAL ENGINEER. DO NOT FLAME- CUT HOLES OR ENLARGE HOLES BY BURNING. DRILL HOLES IN STRUCTURAL STEEL. DO NOT ENLARGE UNFAIR HOLES IN MEMBERS BY BURNING OR BY USING DRIFT PINS. REAM HOLES THAT MUST BE ENLARGED TO ADMIT BOLTS. FIELD MODIFICATIONS TO HOLES IN STRUCTURAL STEEL ARE EXPLICITLY PROHIBITED UNLESS WRITTEN PERMISSION IS GRANTED BY THE STRUCTURAL ENGINEER. WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING CODE FOR STEEL ANSI/AWS D1.1. WELDED CONNECTIONS USING ASTM A992 STEEL AS A BASE METAL SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES. UNLESS OTHERWISE SHOWN OR NOTED ON THE DRAWINGS, OTHER WELDED CONNECTIONS MAY BE MADE WITH STANDARD E70XX ELECTRODES. WELD SIZES SHOWN ON THE DRAWINGS ARE THE REQUIRED EFFECTIVE WELD SIZE. INCREASE WELD SIZES PER AWS FOR SKEWED CONNECTIONS AND CONNECTIONS WITH GAPS BETWEEN MEMBERS TO MEET THE EFFECTIVE WELD SIZE REQUIREMENT. PROVIDE RUN-OFF TABS TO ENSURE COMPLETION OF COMPLETE JOINT PENETRATION (CJP) WELDS AND BEVEL WELDS. REMOVE TABS AND GRIND SMOOTH AFTER COMPLETION. REMOVE WELD BACKING BARS AFTER COMPLETION OF WELDING AND GRIND SMOOTH FOR ALL CONDITIONS EXPOSED TO VIEW IN THE COMPLETED CONSTRUCTION. CONNECTION DETAILS SHOWN ON THE DRAWINGS ARE INTENDED TO CONVEY THE DESIGN INTENT. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, BOLTS, WELDS, PLATES, ETC., AS NECESSARY FOR A COMPLETE ASSEMBLY FOR EACH CONNECTION. IF TEMPORARY ERECTION SUPPORTS ARE UTILIZED BY THE CONTRACTOR, SUCH SUPPORTS SHALL BE REMOVED AFTER COMPLETION OF THE WORK. STRUCTURAL STEEL FINISHES STRUCTURAL STEEL SHALL BE PROVIDED WITH THE FOLLOWING SHOP FINISH UNLESS SPECIFICALLY NOTED OTHERWISE: STRUCTURAL STEEL SHALL BE SHOP-PRIMED WITH RUST-INHIBITING PRIMER. VERIFY PRIMER IS COMPATIBLE WITH FINISH COAT SYSTEM SPECIFIED BY THE ARCHITECT. COORDINATE FINISH PAINTING REQUIREMENTS WITH THE ARCHITECT. ALL EXTERIOR STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED, UNLESS NOTED OTHERWISE. STRUCTURAL STEEL NOTED TO BE GALVANIZED SHALL BE HOT-DIP GALVANIZED IN CONFORMANCE WITH ASTM A123. DO NOT PAINT OR GALVANIZE THE FOLLOWING SURFACES: 1. SURFACES TO BE WELDED. 2. SURFACES TO RECEIVE BOLTED SLIP-CRITICAL CONNECTIONS. 3. SURFACES TO RECEIVE SHEAR STUD CONNECTIONS. 4. SURFACES TO RECEIVE SPRAYED-ON FIREPROOFING. ALL ABRASIONS TO GALVANIZED SURFACES OR SURFACES TO RECEIVE AN ARCHITECTURAL FINISH COAT SHALL BE TOUCHED-UP AFTER ERECTION IS COMPLETE. FOR PAINTED STEEL, USE A PRIMER EQUIVALENT TO THE SHOP PAINT. FOR GALVANIZED STEEL, USE A ZINC-RICH COLD-GALVANIZING PAINT. CONCRETE SLABS ON GRADE SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION (ACI 302.1R). PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE. PROVIDE CURING OF CONCRETE SLABS ON GRADE AS REQUIRED TO ACCOMMODATE FLOOR FINISHES AND FINISH MATERIALS PER THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. REVIEW ALL FLOOR FINISH REQUIREMENTS PRIOR TO PLACEMENT OF CONCRETE SLABS AND COORDINATE SLAB MIX, PLACEMENT AND CURING TO COMPLY WITH FINISH FLOORING MATERIAL MANUFACTURER’S REQUIREMENTS. CURING PROCEDURES SHALL COMPLY WITH ACI 302.1R AND USE OF CURING MATERIALS SHALL BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER’S REQUIREMENTS. MOISTURE RETENTION COVERS, IF USED, SHALL BE APPLIED FLAT AND SMOOTH TO RESULT IN A UNIFORM APPEARANCE AND MINIMIZE SURFACE MARKINGS AND BLEMISHES. UNLESS NOTED OTHERWISE, OR UNLESS MORE STRINGENT REQUIREMENTS APPLY, CURE AND FINISH SLABS ON GRADE IN ACCORDANCE WITH THE SLAB FINISH REQUIREMENTS SCHEDULE. PROVIDE SLABS ON GRADE WITH A SMOOTH TROWEL FINISH UNLESS NOTED OTHERWISE. CONTRACTOR SHALL REVIEW ALL REQUIRED FLOOR FINISH MATERIAL REQUIREMENTS PRIOR TO PLACEMENT OF CONCRETE AND SHALL PROVIDE FLOOR SLAB FLATNESS AND LEVELNESS MEETING THE FINISH MATERIAL SUPPLIER’S WRITTEN REQUIREMENTS. FLATNESS AND LEVELNESS SHALL BE THE MORE STRINGENT OF THE FINISH MATERIAL REQUIREMENTS AND THE FOLLOWING: ALL SLABS, UNO: OVERALL VALUES: FF=25 FL=20 LOCAL VALUES: FF=20 FL=15 CONTRACTOR SHALL PROVIDE ALL NECESSARY REPAIR, GRINDING AND/OR LEVELING OF THE CONCRETE SLAB TO ACCOMMODATE ALL FLOOR FINISHES PRIOR TO INSTALLATION OF THE FINISH MATERIALS WITH NO ADDITIONAL COST TO THE PROJECT. THE MINIMUM LOCAL AREA SHALL BE ANY BAY DEFINED BY COLUMN LINES. UNLESS SHOWN OR NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS-ON-GRADE AT A MAXIMUM SPACING OF 36 TIMES THE SLAB THICKNESS. PROVIDE JOINTS AT ALL COLUMN LOCATIONS. LOCATE JOINTS TO ELIMINATE RE-ENTRANT CORNERS AND TO CREATE SQUARE OR RECTANGULAR SECTIONS WITH MAXIMUM LONG SIDE TO SHORT SIDE RATIO OF 1.5 TO 1. CONTROL JOINTS IN SLABS ON GRADE SHALL NOT RECEIVE JOINT FILLER MATERIAL UNLESS NOTED OTHERWISE. CONCRETE SLABS ON METAL DECK UNLESS INDICATED OTHERWISE ON THE DRAWINGS, CONCRETE SLABS ON METAL DECK SHALL BE PLACED AS REQUIRED TO MAINTAIN A CONSTANT SLAB THICKNESS. UNLESS NOTED OTHERWISE, IT IS THE INTENT TO PLACE SLAB ON METAL DECK CONCRETE WITHOUT THE NEED FOR TEMPORARY SHORING OF THE DECK, HOWEVER IT IS THE CONCRETE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DECK SPAN CONDITIONS AND CAPACITIES PRIOR TO CONCRETE PLACEMENT AND ENSURE THE CONTRACTOR'S PLACEMENT MEANS AND METHODS WILL NOT DAMAGE OR LOAD THE DECK BEYOND IT CAPACITY IN ANY INSTANCE. CONTRACTOR SHALL ALLOW FOR THE DEFLECTION OF THE FLOOR ASSEMBLY DUE TO THE WET WEIGHT OF THE CONCRETE WHEN CALCULATING CONCRETE QUANTITIES AND SHALL INCLUDE THE COST OF ALL REQUIRED SLAB-ON-DECK CONCRETE IN THE BID PRICE. PRIOR TO PLACEMENT OF CONCRETE SLABS ON METAL DECK, THE CONTRACTOR SHALL CAREFULLY REVIEW THE ELEVATIONS OF THE STRUCTURAL STEEL FRAMING, INCLUDING CAMBERED MEMBERS, FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES (SUCH AS IMPROPER CAMBER, IMPROPER STEEL ELEVATIONS, ETC.) IMMEDIATELY AND SHALL NOT BEGIN CONCRETE PLACEMENT WITHOUT PRIOR REVIEW BY THE STRUCTURAL ENGINEER. ACTUAL CONCRETE SLAB THICKNESS SHALL NOT BE LESS THAN THE INDICATED NOMINAL THICKNESS AT ANY LOCATION. IF ANY CONDITION IS DISCOVERED THAT WOULD PREVENT PLACEMENT OF CONCRETE TO THE NOMINAL THICKNESS; CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH CONCRETE PLACEMENT WITHOUT PRIOR REVIEW BY THE STRUCTURAL ENGINEER. PROVIDE SLABS ON METAL DECK WITH A SMOOTH TROWEL FINISH UNLESS NOTED OTHERWISE. CONTRACTOR SHALL REVIEW ALL REQUIRED FLOOR FINISH MATERIAL REQUIREMENTS PRIOR TO PLACEMENT OF CONCRETE AND SHALL PROVIDE FLOOR SLAB FLATNESS MEETING THE FINISH MATERIAL SUPPLIER’S WRITTEN REQUIREMENTS. FLATNESS SHALL BE THE MORE STRINGENT OF THE FINISH MATERIAL REQUIREMENTS AND THE FOLLOWING: ALL SLABS, UNO: OVERALL VALUES: FF=25 LOCAL VALUES: FF=20 CONTRACTOR SHALL PROVIDE ALL NECESSARY REPAIR, GRINDING AND/OR LEVELING OF THE CONCRETE SLAB TO ACCOMMODATE ALL FLOOR FINISHES PRIOR TO INSTALLATION OF THE FINISH MATERIALS WITH NO ADDITIONAL COST TO THE PROJECT. PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE. PROVIDE CURING OF CONCRETE SLABS ON METAL DECK AS REQUIRED TO ACCOMMODATE FLOOR FINISHES AND FINISH MATERIALS PER THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. REVIEW ALL FLOOR FINISH REQUIREMENTS PRIOR TO PLACEMENT OF CONCRETE SLABS AND COORDINATE SLAB MIX, PLACEMENT AND CURING TO COMPLY WITH FINISH FLOORING MATERIAL MANUFACTURER’S REQUIREMENTS. CURING PROCEDURES SHALL COMPLY WITH ACI 302.1R AND USE OF CURING MATERIALS SHALL BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER’S REQUIREMENTS. MOISTURE RETENTION COVERS, IF USED, SHALL BE APPLIED FLAT AND SMOOTH TO RESULT IN A UNIFORM APPEARANCE AND MINIMIZE SURFACE MARKINGS AND BLEMISHES. UNLESS NOTED OTHERWISE, OR UNLESS MORE STRINGENT REQUIREMENTS APPLY, CURE AND FINISH SLABS ON METAL DECK IN ACCORDANCE WITH THE SLAB FINISH REQUIREMENTS SCHEDULE. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:57 PMS002 GENERAL NOTES 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 MASTIC COATING MASTIC COATING FOR PROTECTION OF INDICATED ITEMS SHALL BE BITUMASTIC 50 COAL TAR MASTIC BY CARBOLINE OR EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER. INSTALL AT LOCATIONS INDICATED ON DRAWINGS. UNLESS NOTED OTHERWISE, APPLY MASTIC TO A COATING THICKNESS OF 18 MILS. PROVIDE FULL COVERAGE OVER ITEMS INDICATED TO RECEIVE COATING. APPLY MASTIC COATING TO ALL STEEL ITEMS THAT WILL BE IN PERMANENT CONTACT WITH SOIL OR FILL MATERIALS IN THE COMPLETED CONSTRUCTION. WATERSTOPS SELF-EXPANDING STRIP WATER STOPS SHALL BE VOLCLAY WATERSTOP-RX 101 UNLESS NOTED OTHERWISE. INSTALL IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:57 PMS003 GENERAL NOTES 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 DEFORMED BAR ANCHORS AND HEADED ANCHOR STUDS DEFORMED BAR ANCHORS (DBA) AND HEADED ANCHOR STUDS (HAS) USED TO ANCHOR STEEL ELEMENTS TO CONCRETE SHALL BE SUPPLIED AND INSTALLED BY THE STRUCTURAL STEEL CONTRACTOR, UNLESS NOTED OTHERWISE. ANCHORS SHALL BE FULL-BASE WELDED USING AUTOMATICALLY TIMED WELDING EQUIPMENT AND APPROPRIATE FERRULE IN ACCORDANCE WITH APPLICABLE PROVISIONS OF AWS D1.5. DEFORMED BAR ANCHORS SHALL BE TYPE C DEFORMED STEEL BARS MANUFACTURED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM A496, WITH A YIELD STRENGTH OF 70 KSI. HEADED ANCHOR STUDS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM A108, WITH A YIELD STRENGTH OF 50 KSI. WHEN APPROVED IN ADVANCE BY THE STRUCTURAL ENGINEER, INTERNALLY THREADED WELDED COUPLERS WITH FULLY DEVELOPED THREADED-END REBAR OF EQUIVALENT SIZE MAY BE USED IN LIEU OF DIRECT-WELDED DEFORMED BAR ANCHORS AS NEEDED FOR CONSTRUCTION PHASING LOGISTICS AND/OR ADHERENCE TO OSHA REQUIREMENTS. STEEL FLOOR DECK PROVIDE AND ERECT STEEL DECK IN ACCORDANCE WITH THE LATEST EDITION OF THE STEEL DECK INSTITUTE'S SPECIFICATIONS AND CODE OF STANDARD PRACTICE. DECK MANUFACTURER SHALL PROVIDE ALL FLOOR DECK ACCESSORIES, SUCH AS EDGE FORMS, CLOSURES, FILLERS AND POUR STOPS FOR A COMPLETE INSTALLATION, WHETHER OR NOT SUCH ITEMS ARE DETAILED ON THE CONTRACT DOCUMENTS. FASTEN FLOOR DECK TO STEEL SUPPORTS AS INDICATED ON THE DRAWINGS. PERFORM WELDING IN ACCORDANCE WITH ANSI/AWS D1.3. STEEL FLOOR DECK IS INTENDED TO BE INSTALLED IN AN UNSHORED CONDITION UNLESS NOTED OTHERWISE. DECK SUPPLIER SHALL REVIEW ALL SPAN CONDITIONS AND CONFIRM THAT THE SUPPLIED PRODUCT IS SUFFICIENT TO SAFELY SUPPORT THE WET WEIGHT OF CONCRETE AND ASSOCIATED CONSTRUCTION LIVE LOADS WITHOUT THE NEED FOR SHORING. FLOOR DECK UNITS SHALL BE INSTALLED IN A MINIMUM THREE SPAN CONDITION WHEREVER POSSIBLE. WHERE THREE SPAN CONDITION IS NOT POSSIBLE, NOTIFY STRUCTURAL ENGINEER PRIOR TO FABRICATION OF DECK SO THAT EVALUATION OF THE LESSER SPAN CONDITION(S) CAN BE PERFORMED. PROVIDE INTERIOR STEEL FLOOR DECK WITH FINISH AS INDICATED ON THE DRAWINGS. PROVIDE FLOOR DECK SUPPORTING EXTERIOR SLABS WITH A GALVANIZED FINISH IN ACCORDANCE WITH ASTM A924 G90. DESIGN DATA NEW STRUCTURES ON THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE. SEE LOAD MAPS FOR LOADING INFORMATION. UNLESS OTHERWISE NOTED, FLOOR FRAMING HAS BEEN DESIGNED UTILIZING LIVE LOAD REDUCTIONS TO THE EXTENT ALLOWED BY THE BUILDING CODE. VIBRATION CRITERIA UNLESS NOTED OTHERWISE, ELEVATED STRUCTURAL STEEL FLOOR FRAMING HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS OF "VIBRATIONS OF STEEL-FRAMED SYSTEMS DUE TO HUMAN ACTIVITY" (2016) BY MURRAY, ALLEN, UNGAR AND DAVIS, WITH ASSUMED DAMPING AND LIMITING VIBRATION CRITERIA AS FOLLOWS: TYPICAL FLOORS, UNO: DAMPING RATIO, BETA = 0.020 MAXIMUM VIBRATION ACCELERATION = 0.5% OF GRAVITY THE STRUCTURE IS NOT DESIGNED TO MITIGATE VIBRATIONS FROM VIBRATING EQUIPMENT. EQUIPMENT CONTRACTOR SHALL PROVIDE AND INSTALL VIBRATION ISOLATORS AS REQUIRED TO MITIGATE EQUIPMENT VIBRATION. SNOW LOAD DESIGN DATA GROUND SNOW LOAD (PG) = 20 PSF SNOW EXPOSURE FACTOR (CE) = 1.0 THERMAL FACTOR (CT) = 1.0 SNOW LOAD IMPORTANCE FACTOR (IS) = 1.0 MINIMUM LOW-SLOPE ROOF SNOW LOAD (PM) = 20 PSF WIND LOAD DESIGN DATA BASIC WIND SPEED (3-SECOND GUST) = 115 MPH WIND EXPOSURE = C WIND DESIGN PRESSURE (P) = VARIES WITH HEIGHT AND LOCATION EARTHQUAKE DESIGN DATA SHORT PERIOD SPECTRAL RESPONSE (SS) = 0.152 1-SECOND SPECTRAL RESPONSE (S1) = 0.083 SEISMIC IMPORTANCE FACTOR (IE) = 1.0 RISK CATEGORY = II SITE CLASSIFICATION = D SEISMIC DESIGN CATEGORY =C SHORT PERIOD SPECTRAL RESPONSE (SDS) = 0.163 1-SECOND SPECTRAL RESPONSE (SD1) = 0.134 BASIC STRUCTURAL SYSTEM / SEISMIC RESISTING SYSTEM: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE / ORDINARY REINFORCED MASONRY SHEAR WALLS ANALYSIS PROCEDURE UTILIZED = EQUIVALENT LATERAL FORCE PROCEDURE RESPONSE MODIFICATION COEFFICIENT (R) = 3.0 / 2.0 SEISMIC RESPONSE COEFFICIENT (CS) = 0.054 / 0.081 LATERAL LOAD RESISTING SYSTEM LATERAL FORCE RESISTANCE IN THE COMPLETED STRUCTURE IS PROVIDED AS FOLLOWS: ELEVATED FLOOR SLABS AND ROOF SLABS / DECKS SERVE AS HORIZONTAL DIAPHRAGMS TO TRANSFER LATERAL LOADS TO THE VERTICAL LATERAL LOAD RESISTING ELEMENTS WHICH IN TURN TRANSFER THOSE LOADS TO THE FOUNDATION SYSTEM. VERTICAL LATERAL LOAD RESISTING ELEMENTS ARE INDICATED ON THE DRAWINGS AND CONSIST OF THE FOLLOWING, UNLESS NOTED OTHERWISE: PLAN NORTH-SOUTH DIRECTION: REINFORCED MASONRY SHEAR WALLS PLAN EAST-WEST DIRECTION: STEEL BRACED FRAMES SERVICEABILITY LIMITS LIVE LOAD DEFLECTION: SPAN/360 UNO TOTAL LOAD DEFLECTION: SPAN/240 UNO EXTERIOR EDGE BEAMS LIVE LOAD DEFLECTION: SPAN/480 OR 1/2 INCH, UNO EXTERIOR EDGE BEAMS TOTAL LOAD DEFLECTION: SPAN/360 OR 1 INCH, UNOLOADS SUSPENDED FROM STRUCTURE UNLESS SPECIFICALLY NOTED OTHERWISE, THE UNIFORM MEP/CEILING LOADING ALLOWANCE SUSPENDED FROM FLOOR AND ROOF STRUCTURES SHALL BE 10 PSF. CONTRACTOR SHALL COORDINATE AND PROVIDE SUFFICIENT SUPPORT FRAMING FOR ITEMS SUSPENDED FROM THE STRUCTURE (DUCTWORK, PIPING, CONDUIT, LIGHTS, CEILINGS, ETC.) TO DISTRIBUTE LOADING THROUGHOUT THE STRUCTURE SUCH THAT THE DESIGN SUPERIMPOSED LOAD ALLOWANCE IDENTIFIED IS NOT EXCEEDED FOR ANY STRUCTURAL ELEMENT. IF THE CONTRACTOR DETERMINES THAT LOADS SUSPENDED WILL EXCEED THE IDENTIFIED LOADING LIMITS FOR ANY STRUCTURAL ELEMENT, THE CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO INSTALLING THE LOADS. LOADS SUSPENDED FROM HANGER TABS ON COMPOSITE STEEL FLOOR DECK SHALL NOT EXCEED 50 LBS AT ANY SINGLE LOCATION. LOADS SHALL NOT BE SUSPENDED FROM STEEL ROOF DECK. LOADS IMPOSED ON STRUCTURE LOADS IMPOSED ON THE STRUCTURE BY EQUIPMENT AND SYSTEMS (INCLUDING BUT NOT LIMITED TO, ARCHITECTURAL PRECAST CONCRETE, CURTAIN WALL, CLADDING, STAIRS, ELEVATORS, ESCALATORS, MEP EQUIPMENT, DUCTWORK, CONDUIT, LIGHTS, CEILINGS, ETC.) SHALL IMPART ONLY VERTICAL AND HORIZONTAL LOADS ON THE STRUCTURE WITHOUT INDUCING TORSIONAL LOADS ON THE SUPPORTING STRUCTURAL ELEMENTS, UNLESS SPECIFICALLY INDICATED OTHERWISE. THE CONTRACTOR IS RESPONSIBLE FOR DESIGNING (BY THE CONTRACTOR'S PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS CONSTRUCTED), SUPPLYING, AND INSTALLING ALL NECESSARY SUPPLEMENTAL BRACING, KICKERS, RELATED CONNECTIONS, ETC., AS REQUIRED TO PREVENT APPLYING TORSIONAL LOAD TO THE SUPPORTING STRUCTURE. DESIGN CALCULATIONS AND DETAILS, SIGNED AND SEALED BY THE CONTRACTOR'S LICENSED PROFESSIONAL ENGINEER, FOR ALL SUPPLEMENTAL MATERIALS AND CONNECTIONS UTILIZED TO PREVENT APPLYING TORSIONAL LOAD TO THE STRUCTURE, SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION.EXPANSION ANCHORS EXPANSION ANCHORS SHALL BE HILTI “KWIK BOLT TZ” OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. ANCHOR FINISH SHALL BE CARBON STEEL FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER’S REPRESENTATIVE. ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH. ADHESIVE ANCHORS FOR SOLID SUBSTRATES (THREADED ROD AND REBAR) ADHESIVE ANCHORS FOR SOLID SUBSTRATES SHALL BE HILTI "HIT-HY 200" OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. THREADED ANCHORS SHALL BE ASTM A36 RODS FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH. ADDITIONALLY, ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY WITH AN AGE OF LESS THAN 21 DAYS. MINIMUM EMBEDMENT DEPTH SHALL BE 8 DIAMETERS UNLESS NOTED OTHERWISE. ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES SHALL BE HILTI "HIT-HY 270" WITH HILTI “HIT-SC” SCREEN TUBE OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO. ANCHORS SHALL BE ASTM A36 THREADED RODS FOR INTERIOR EXPOSURES AND AISI 316 STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. CONCRETE UNIT MASONRY CONCRETE MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CODE-REFERENCED EDITION OF BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 402/602). CONCRETE MASONRY SHALL CONSIST OF HOLLOW UNITS CONFORMING TO THE REQUIREMENTS OF ASTM C90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 2,800 PSI, UNO. CONCRETE MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'M) OF 2,000 PSI AT 28 DAYS, UNO. ALL MASONRY TO BE LAID IN RUNNING BOND, UNO. ALIGN CELLS TO ALLOW PROPER REINFORCEMENT PLACEMENT AND GROUTING. MORTAR SHALL BE TYPE S PROPORTIONED IN ACCORDANCE WITH ASTM C270. FULLY MORTAR FACE SHELLS ON HEAD AND BED JOINTS. PROVIDE FULL MORTAR COVER ON ALL WEBS AT GROUTED CELLS. GROUT FOR REINFORCED MASONRY SHALL BE PROPORTIONED IN ACCORDANCE WITH ASTM C476 (MINIMUM 28-DAY COMPRESSIVE STRENGTH = 2,000 PSI, UNO). COARSE AND FINE AGGREGATES SHALL CONFORM TO ASTM C404. USE COARSE GROUT FOR ALL GROUTING EXCEPT HIGH-LIFT POURS DEFINED BY ACI 530, WHERE FINE GROUT SHALL BE USED. GROUT SOLID ALL CELLS WITH REINFORCEMENT. GROUT SOLID ALL CELLS AT BELOW-GRADE CMU IN CONTACT WITH SOIL. PROVIDE 9-GAUGE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY CONSTRUCTION. REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED EIGHT INCHES AT SPLICES. CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS. SPACE REINFORCEMENT AT 8" ON CENTER FOR PARAPETS AND BELOW GROUND FLOOR ELEVATION. ELSEWHERE SPACE REINFORCEMENT AT 16 INCHES ON CENTER, UNLESS NOTED OTHERWISE. BEAMS AND LINTELS SHALL BEAR A MINIMUM OF 8 INCHES ONTO SUPPORTING MASONRY, UNLESS NOTED OTHERWISE. BEARING FOR ALL BEAMS, LINTELS, JOISTS, ETC. SHALL BE GROUTED SOLID A MINIMUM OF ONE COURSE (8 INCHES) BELOW BEARING ELEVATION, UNLESS NOTED OTHERWISE. PROVIDE MASONRY CONTROL JOINTS AT 25'-0" OC MAXIMUM, UNO. LOCATE JOINTS IN ACCORDANCE WITH NCMA TEK 10-2C "CONTROL JOINTS FOR CONCRETE MASONRY WALLS - EMPIRICAL METHOD" AT OFFSETS, SETBACKS, WALL INTERSECTIONS, CORNERS, CHANGES IN THICKNESS, CHANGES IN HEIGHT, OR EDGE OF OPENINGS. REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21 A E1 E2 EA EB EC ED EE A.8 B.4 B.9 C.3 C.6 1.1 1.3 A.1 EXISTING MEZZANINE 1.6 1.4 1.2 UNIFORM LOAD SCHEDULE MARK DESCRIPTION DESIGN LOADS (PSF) DEAD LIVE NOTES: 1. DEAD LOAD (WHEN DEFINED) REPRESENTS SELF-WEIGHT ALLOWANCE OF THE PRIMARY STRUCTURAL SYSTEM. WHEN NOT DEFINED, SEE DRAWINGS FOR MEMBER MATERIALS AND SIZES. 2. SUPERIMPOSED DEAD LOAD IS PERMANENT UNIFORM DEAD LOAD ALLOWANCE SUPPORTED BY THE STRUCTURE. 3. FOR SNOW LOADS DESIGN FOR WORST CASE OF UNIFORM SNOW OR SNOW DRIFT CONDITION. 4. "NR" = NON-REDUCIBLE LIVE LOAD. A TYPICAL FLOOR SEE NOTE 1 SNOW NA SUPERIMPOSED DEAD 10 80 E1 E2 EA EB EC ED EE A.8 B.4 B.9 C.3 C.6 1.1 1.3 A.1 EXISTING ROOF 1.6 NEW RTU BY MEP CONTRACTOR 1.4 1.2 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:58 PMS004 LOAD MAPS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S004 1 LOAD MAP -MEZZANINE N.T.S.S004 3 UNIFORM LOAD SCHEDULE N.T.S.S004 2 LOAD MAP -ROOF REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 L1L1 L1L1 L2 L1E1 E2 EA EB EC ED EE 40' - 0" 170' - 0"40' - 0" 40' - 0" 40' - 0" 50' - 0"A A REFERENCE ARCH DWGS FOR CMU DEMOLITION INFORMATION EX FTG TO REMAIN, TYP EX STL COL TO REMAIN, TYP EX PRECAST WALL PANEL, TYP APPROX LOCATION OF EX FIRE RISER APPROX LOCATION OF EX WATER RISER EX FTG BELOW EX FTG EX CMU WALL EX FTG TO REMAIN T/FTG = T/SLAB TYP A TYP TYP B 6 S302 1 1.4 E1 E2 EA EB EC ED EE 40' - 0"170' - 0"40' - 0" 40' - 0" 40' - 0" 50' - 0"A.8 B.4 B.9 C.3 C.6 1.1 1.3 A.1 2' - 4 1/4" FV 1' - 0" 9' - 1 5/8" 12' - 4 3/8" 15' - 1 3/4" FV CMU W1 EX 7'-0"X7'-0"X1'-3" THK FTG (FV) EX STL COL, TYP APPROX LOCATION OF EX FIRE RISER B TYP EX PRECAST WALL PANEL, TYP 1.6 6 S301 1 2 D E C B A A EX 2'-0" W X 2'-6" THK WALL FTG (FV) B B 3' - 4 1/4" FV 35' - 10 3/4" 9" FV13' - 9 1/2" 15' - 7 5/8" 10' - 6 7/8" FV 12' - 6 1/4" FV 14' - 4" 13' - 1 3/4" FVALIGN FACE OF NEW CMU TO EX FACE OF CMU WF303 S301 TYP 9 S301 EX T/FTG 99' -4" (FV) EX 7'-0"X7'-0"X1'-3" THK FTG (FV) EX T/FTG 97' -4" (FV) 4 S302 4 S302 4 S302 SIM 6 S302 4 S302 SIM 4 S302 SIM B TYP POST FOR INTERMEDIATE LANDING, TYP. COORDINATE ALL SUPPORT LOCATIONS WITH STAIR SUPPLIER PRIOR TO DEMOLITION. SELF-SUPPORTING STEEL PAN STAIR BY STAIR CONTRACTOR 1 10 S302 1' - 6"1.4 EX 3'-0"W X 1'-3" THK WALL FOOTING - T/FTG EL 99'-4" (FV) 1.2 EX CMU WALL (FV) UNDERPIN EX FDN AS REQUIRED FOR INSTALLATION OF NEW WORK T/FTG 99'-4" 3' - 0" T/FTG 99'-4" 22' - 6" T/FTG 99'-4" 4" FTG STEP EX 2'-0" W X 2'-6" THK WALL FTG (FV) 3' - 6" F4.0C F5.0C F4.5C 4' - 0" S303 1 S303 2 C D D2' - 0" 3' - 0"4' - 0"Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:06:59 PMS101 DEMOLITION AND FOUNDATION PLANS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N 3/32" = 1'-0"S101 1 FOUNDATION DEMOLITION PLAN 3/32" = 1'-0"S101 2 FOUNDATION PLAN N GENERAL PLAN NOTES: 1. REFERENCE TOP OF SLAB (T/SLAB) = 100'-0" UNO. 2. TOP OF INTERIOR FOOTING COLUMN ELEVATION = 99'-0" UNO. TOP OF INTERIOR WALL FOOTING ELEVATION = 99'-4" UNO. 3. TOP OF EX PERIMETER FOOTING ELEVATION = 99'-0" UNO (FIELD VERIFY). 4. REFER TO STRUCTURAL GENERAL NOTES, LEGEND, SCHEDULES, TYPICAL DETAILS, AND SPECIAL INSPECTION REQUIREMENTS FOR ADDITIONAL INFORMATION. 5. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND DIMENSIONS. 6. PROVIDE ADDITIONAL SLAB ON GRADE REINFORCEMENT AT RE-ENTRANT CORNERS PER THE "TYPICAL ADDITIONAL SLAB ON GRADE REINFORCEMENT AT RE-ENTRANT CORNERS" DETAIL. 7. COORDINATE LOCATIONS OF ALL EMBEDS / OPENINGS / SLEEVES WITH MEP, WALL SYSTEMS, EQUIPMENT SUPPLIERS, AND ALL OTHER AFFECTED TRADES PRIOR TO PLACING CONCRETE. 8. LOCATE ALL EXISTING BELOW GRADE UTILITIES PRIOR TO EXCAVATION AND INSTALLATION OF NEW WORK. NOTIFY ENGINEER OF ANY INTERFERENCES. GENERAL PLAN NOTES: 1. REFER TO STRUCTURAL GENERAL NOTES, LEGEND, SCHEDULES, TYPICAL DETAILS, AND SPECIAL INSPECTION REQUIREMENTS FOR ADDITIONAL INFORMATION. 2. REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION 3. EXCAVATION EXTENTS SHALL BE MINIMIZED AS PRACTICAL TO INSTALL NEW WORK. 4. UNDERPINNING OF EXISTING FOUNDATIONS PER THE CONTRACTOR AS REQUIRED FOR INSTALLATION OF NEW WORK. 5. VERIFY ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH NEW WORK. NOTIFY ENGINEER OF ANY DISCREPANCIES. 6. PROTECT ALL ITEMS TO REMAIN. KEYED PLAN NOTES: SAWCUT AND REMOVE EXISTING SLAB AS REQUIRED TO INSTALL NEW WORK. EXCAVATE EXISTING SUBGRADE AS REQUIRED TO INSTALL NEW WORK. DO NOT UNDERMINE EXISTING FOUNDATIONS. DEMOLISH EXISTING WALL FOOTING AS REQUIRED TO INSTALL NEW WORK. EXCAVATE EXISTING SUBGRADE AS REQUIRED TO INSTALL NEW WORK. DO NOT UNDERMINE EXISTING FOUNDATIONS. A KEYED PLAN NOTES: APPROXIMATE LOCATION OF EXISTING WATER RISER. CONTRACTOR TO LOCATE UNDERGROUND PIPE PRIOR TO NEW WORK. NOTIFY ENGINEER IF PIPE INTERFERES WITH NEW WORK. PROVIDE NEW SLAB ON GRADE TO MATCH EXISTING TO REPLACE DEMOLISHED SLAB, TYPICAL. REFER TO TYPICAL DETAILS FOR ADDITIONAL INFORMATION. PROVIDE TOOLED CONTROL JOINTS IN THE NEW SLAB AT LOCATIONS OF EXISTING SLAB JOINTS AND AT A SPACING SUCH THAT NO PANEL EXCEEDS A 2:1 RATIO. ANCHOR NOTED NEW FTG TO EXISTING WITH (3) #5x3'-0" ADHESIVE DOWELS (8" EMBED) EXTEND NOTED COMBINED COLUMN FOOTING TO EAST EDGE OF INTERSECTING WALL FOOTING. EXTEND WALL FOOTING REINFORCEMENT CONTINUOUS THROUGH THE COLUMN FOOTING. FTG STEP. SEE "TYPICAL STEPPED FOOTING" DETAIL. A B CONTRACTOR NOTES 1. DOCUMENTATION OF HIDDEN AND SUBGRADE EXISTING CONSTRUCTION WAS NOT AVAILABLE DURING THE DESIGN PHASE. EXISTING FOUNDATIONS AND OTHER HIDDEN EXISTING ELEMENTS SHOWN ON THESE DOCUMENTS ARE BASED ON ASSUMED SIZES, CONFIGURATIONS AND ELEVATIONS AND ARE PROVIDED FOR REFERENCE ONLY. 2. CONTRACTOR SHALL FIELD VERIFY AND PRESENT FINDINGS TO THE A/E FOR REVIEW IDENTIFYING THE EXACT CONFIGURATION OF EXISTING CONSTRUCTION PRIOR TO FABRICATION AND INSTALLATION OF NEW STRUCTURAL ELEMENTS. 3. CONTRACTOR SHALL ALERT THE A/E OF ANY REQUIRED REVISIONS TO THE DESIGN NECESSARY TO ACCOMMODATE EXISTING CONDITIONS THAT DIFFER FROM THE ASSUMPTIONS DEPICTED HEREIN. C B D E NOTE: FOUNDATION DEMOLITION PLAN IS REVISED IN ITS ENTIRETY PER ADDENDUM 2 NOTE: FOUNDATION DEMOLITION PLAN IS REVISED IN ITS ENTIRETY PER ADDENDUM 2 2 2 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDENDUM 1 05/20/2021 2 ADDENDUM 2 07/02/2021 09/16/21 L1L1 L1 L1 L2 L1 E1 E2 EA EB EC ED EE 40' - 0" 170' - 0"40' - 0" 40' - 0" 40' - 0" 50' - 0"EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH EX 32LH 1' - 7 3/4" EOS A.8 B.4 B.9 C.3 C.6 1.1 1.3 A.1 3' - 4 1/4" FV 35' - 10 3/4"9" FV13' - 9 1/2" 15' - 7 5/8" 10' - 6 7/8" FV 12' - 6 1/4" FV 14' - 4" 13' - 1 3/4" FVS1 1/S504 2/S504 EX STL COL, TYP 2 S501 EX CMU WALL BELOW EX PRECAST WALL NEW CMU WALL BELOW 2 S501 3 S502 2 S501 1' - 9 1/4" EOS1' - 9 1/4" EOS1' - 9 1/4" EOS 6' - 2 1/4"6' - 2 1/4" 1.6 1' - 4 1/2" EOS 2' - 4 1/4" FV 1' - 0" 9' - 1 5/8" 5' - 4 3/8" 7' - 0" 15' - 1 3/4" FV 9"30' - 2 1/8" 23' - 1 1/8"4 EQ SPA 22' - 6" 3 EQ SPA 15' - 1 3/4"7' - 11 1/4" 6" EOS2' - 7 3/4" EOS6" EOS 6' - 7 5/8" EX CMU WALL BELOW EX PRECAST WALL A A B B 6 S502 1 S502 TYP 5 S502 TYP TYP SELF-SUPPORTING STEEL PAN STAIR BY STAIR CONTRACTOR 1 1.4 1 S502 TYP W24X76 W18X35 W24X76 W18X35 W18X35 W24X76 W21X57 W16X26 W10X12 W18X35 W14X22 W10X12W18X35W10X12W10X12W10X12W10X12W10X12W10X12W14X22W14X22W14X22W14X22W14X22W14X22W14X22W16X26W16X31W16X31W16X31W16X31W16X31W16X31W18X35W18X40W18X40W18X40W18X40W18X40W18X402' - 4 3/4" 1.2 E1 E2 EA EB EC ED EE 40' - 0"170' - 0"40' - 0" 40' - 0" 40' - 0" 50' - 0"EX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 40G EX 28KEX 28KEX 28KEX 28KEX 28KEX 28KEX 28KEX 48G EX 28KEX 28KEX 28KEX 28KEX 28KEX 28KEX 28KEX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 30KEX 40G NEW RTU BY MEP CONTRACTOR (1,500 LBS) EX PRECAST WALL EX PRECAST WALL EX STL COL, TYP EX PRECAST WALL 500 LBS (NOTE 3)300 LBS (NOTE 3) 1 1.4 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:01 PMS102 MEZZANINE AND ROOF FRAMING PLANS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N 3/32" = 1'-0"S102 1 MEZZANINE FRAMING PLAN GENERAL PLAN NOTES: 1. TOP OF SLAB (T/SLAB) ELEVATION = 114' -0" UNO. 2. TOP OF STEEL (T/STL) ELEVATION = 113' -8" UNO. 3. REFER TO STRUCTURAL GENERAL NOTES, LEGEND, SCHEDULES, TYPICAL DETAILS, AND SPECIAL INSPECTION REQUIREMENTS FOR ADDITIONAL INFORMATION. 4. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND DIMENSIONS. 5. MECHANICAL CONTRACTOR SHALL COORDINATE LOCATION OF ALL OPENINGS IN FLOOR WITH STRUCTURAL FRAMING. NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICTS. 3/32" = 1'-0"S102 2 EXISTING ROOF FRAMING PLAN GENERAL PLAN NOTES: 1. REFER TO STRUCTURAL GENERAL NOTES, LEGEND, SCHEDULES, TYPICAL DETAILS, AND SPECIAL INSPECTION REQUIREMENTS FOR ADDITIONAL INFORMATION. 2. PROVIDE L4x4x1/4 RTU SUPPORT FRAMING SIM TO "TYPICAL SLAB ON METAL DECK OPENING (EXISTING FRAMING)" DETAIL AND "TYPICAL RTU SUPPORT" DETAIL. PROVIDE JOIST REINFORCING FOR CONCENTRATED LOADS AT THE NEW RTU PER TYPICAL DETAIL PROVIDED ON S503. COORDINATE LOAD LOCATIONS WITH MECHANICAL UNIT SUPPLIER. N KEYED PLAN NOTES: PROVIDE 1" CLEAR BETWEEN EXISTING PIPE AND BEAM FLANGE. FIELD VERIFY LOCATION OF PIPE PRIOR TO FABRICATION OF NEW MATERIAL. PROVIDE 1/2" EXPANSION JOINT MATERIAL AROUND EXISTING PIPES SLEEVED THROUGH NEW SLAB. PROVIDE 1/2" EXPANSION JOINT MATERIAL AROUND EXISTING COLUMN AND PROVIDE DECK CLOSURE AROUND COLUMN AS REQUIRED. DO NOT SUPPORT SLAB FROM EXISTING COLUMN. A B CONTRACTOR NOTES: 1. FLOOR OPENING, ROOF OPENING, RTU SUPPORT, AND JOIST REINFORCING FOR MECHANICAL SYSTEMS AND EQUIPMENT WILL BE ISSUED AFTER THE MEP SYSTEMS DESIGN IS COMPLETED BY THE DESIGN BUILD CONTRACTOR FOR THOSE ITEMS. 1 NOTE: MEZZANINE FRAMING PLAN IS REVISED IN ITS ENTIRETY PER ADDENDUM 2 2 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDENDUM 1 05/20/2021 2 ADDENDUM 2 07/02/2021 09/16/21 MARK FTG SIZE FTG REINF REMARKS COLUMN FOOTING SCHEDULE F4.0C 4'-0" x PLAN x 2'-6"(6) #6 LONG TOP AND BOT #6 @ 7" SHORT TOP AND BOT F4.5C 4'-6" x PLAN x 2'-0"(6) #6 LONG TOP AND BOT #6 @ 8" SHORT TOP AND BOT F5.0C 5'-0" x PLAN x 2'-0"(11) #6 LONG TOP AND (6) #6 LONG BOT #6 @ 9" SHORT TOP AND BOT 2 MARK SIZE (W x D) FTG REINF REMARKS WALL FOOTING SCHEDULE WF30 2'-6" x 1'-0" (3) #5 CONT BOT CMU WALL & REINF PER PLAN HOOKED DOWEL, SIZE AND SPACING TO MATCH VERTICAL REINFORCING LAP SPLICE PER MASONRY LAP SPLICE CHART, UNO 1/2" EXP JT MATL, TYP EXIST SLAB FTG PER PLAN 3" CLRT/SLAB PER PLAN #4 x 1'-4" @ 24" OC DRILL & GROUT 0'-8" INTO EXISTING SLAB T/FTG PER PLANSAWCUT, REMOVE & REPLACE EXISTING SLAB AS REQUIRED TO CONSTRUCT FOOTING & WALL (SLAB THICKNESS TO MATCH EXISTING) NOTE: REINFORCE NEW SLAB-ON-GRADE CONCRETE WITH WWR PER SLAB ON GRADE SCHEDULE 2 SLAB DEPTH (IN) DOWEL SIZE AND SPACING DOWEL BAR DIAMETER (IN) TOTAL BAR LENGTH (IN) BAR SPACING (CTR - CTR) (IN) 5-6 3/4 16 12 CONSTRUCTION JOINT EXISTING SLAB COAT OR WRAP DOWEL TO PREVENT BOND SMOOTH DOWEL BAR PER TABLE. DRILL AND EPOXY 1/2 x BAR LENGTH INTO EXISTING SLAB. INSTALL AT MID-DEPTH OF SLAB, UNO. NEW SLAB ON GRADE PER PLAN SEE PLANDAPPLY BOND BREAKER TO FACE OF EXISTING SLAB PRIOR TO PLACEMENT OF NEW SLAB 4 3/4 16 24 REINFORCING BAR LAP LENGTHS: Lt, Lc AND DEVELOPMENT LENGTHS: Ld, Ldh, Ldt, Ldc (INCHES) f 'c = 3000 PSI BAR SIZE Ld Ldh Ldt Ldc 17 9 7 #3 22 11 9 #4 28 14 11 #5 33 17 14 #6 48 20 16 #7 55 22 18 #8 62 25 20 #9 70 28 23 #10 78 31 25 #11 NOTES: 1. db = DIAMETER OF BAR BEING DEVELOPED Lt = "CLASS B" TENSION LAP SPLICE LENGTH Lc = COMPRESSION LAP SPLICE LENGTH Ld = TENSION DEVELOPMENT LENGTH OF STRAIGHT BARS Ldh= TENSION DEVELOPMENT LENGTH OF HOOKED BARS Ldt = TENSION DEVELOPMENT LENGTH OF HEADED BARS Ldc = COMPRESSION DEVELOPMENT LENGTH OF STRAIGHT BARS 2. TABULATED VALUES ARE CALCULATED PER THE PROVISIONS OF ACI 318 3. TABULATED VALUES ARE FOR NON-EPOXY-COATED GRADE 60 REINFORCEMENT IN NORMAL WEIGHT CONCRETE. 4. WHERE BARS OF DIFFERENT SIZES ARE LAPPED IN TENSION, THE LAP LENGTH SHALL BE THE LARGER OF Ld OF THE LARGER BAR AND Lt OF THE SMALLER BAR. 5. WHERE BARS OF DIFFERENT SIZES ARE LAPPED IN COMPRESSION, THE LAP LENGTH SHALL BE THE LARGER OF Ldc OF THE LARGER BAR AND Lc OF THE SMALLER BAR. 6. TABULATED VALUES FOR Lt ASSUME THE FOLLOWING: A) MINIMUM CLEAR SPACING BETWEEN REBAR IS THE GREATER OF THE BAR DIAMETER AND 1 INCH. B) MINIMUM CLEAR COVER IS 3/4 INCHES OR GREATER. C) BARS BEING SPLICED ARE NOT REQUIRED TO BE ENCLOSED WITHIN REINFORCEMENT ACTING AS CONFINEMENT TIES. 7. TABULATED VALUES FOR Ld ASSUME ONE OF THE FOLLOWING CONDITIONS IS PROVIDED; WHERE THESE CONDITIONS AREN'T ABLE TO BE MET, CONTACT ENGINEER OF RECORD FOR CONDITION SPECIFIC VALUES: A) BARS BEING DEVELOPED ARE ENCLOSED WITHIN REINFORCEMENT ACTING AS CONFINEMENT TIES, AND CLEAR SPACING OF BARS BEING DEVELOPED IS GREATER THAN OR EQUAL TO db, AND CLEAR COVER TO BAR BEING DEVELOPED IS GREATER THAN OR EQUAL TO db B) CLEAR SPACING OF BARS BEING DEVELOPED IS GREATER THAN OR EQUAL TO 2 TIMES db, AND CLEAR COVER TO BAR BEING DEVELOPED IS GREATER THAN OR EQUAL TO db 8. TABULATED VALUES FOR Ldt ARE ONLY VALID FOR NORMAL WEIGHT CONCRETE WITH CLEAR COVER NOT LESS THAN 2 TIMES db AND CLEAR SPACING NOT LESS THAN 4 TIMES db (CLEAR COVER AND SPACING REQUIREMENTS LISTED IN THE GENERAL NOTES APPLY TO THE HEAD/ANCHOR, CLEAR COVER AND SPACING IN THIS PROVISION ARE WITH RESPECT TO THE REINFORCING ONLY) 9. LENGTHS IN THE SCHEDULE SHALL BE MULTIPLIED BY THE FOLLOWING MODIFICATION FACTORS AS FOLLOWS: A) WHERE GRADE 75 REINFORCING IS USED, MULTIPLY THE TABLE VALUES AS FOLLOWS: i) Lt, Ld, Ldh, Ldc x1.25 ii) Lc x1.45 iii) Ldt NOT PERMITTED B) WHERE MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST BELOW THE BAR, ALSO REFERRED TO AS "TOP BARS" ("OTHER BARS" ARE ALL OTHERREINFORCING WHERE THIS DOES NOT APPLY) i) Lt, Ld x1.30 ii) Lc, Ldh, Ldt, Ldc NO MODIFICATION 10. THIS TABLE IS NOT VALID FOR BUNDLED BARS. f 'c = 4000 PSI Ld Ldh Ldt Ldc 15 8 6 19 10 8 24 12 10 29 15 12 42 17 14 48 19 16 54 22 18 61 25 20 67 27 22 9 11 14 17 20 22 25 28 31 8 10 12 15 17 19 22 25 27 LcLt 18 29 42 55 88 107 109 126 146 16 25 36 48 76 93 95 109 127 12 15 19 23 27 30 34 39 43 LcLt 12 15 19 23 27 30 34 39 43 1. SEE GENERAL NOTES AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. ALL CONCRETE IS NORMAL WEIGHT AND CEMENT IS ASTM C150 TYPE 1, UNO. DO NOT USE LIGHTWEIGHT CONCRETE UNLESS SPECIFICALLY INDICATED. 3. ACCEPTABLE CEMENT REPLACEMENT MATERIAL, WHERE PERMITTED, SHALL BE FLY ASH, ASTM C618 TYPE C OR F, UNO. 4. TARGET SLUMP SHALL BE DETERMINED BY THE CONTRACTOR AS NEEDED FOR PROPER PLACEMENT. 5. WHERE NOTED, BLENDED AGGREGATE WITH ZONE 2 COARSENESS PER ACI 302 IS MANDATORY. 6. COORDINATE LOCATIONS OF ALL POLISHED CONCRETE SLABS (WHEN USED) AND REVIEW THE CONCRETE MIX REQUIREMENTS WITH THE POLISHED CONCRETE CONTRACTOR PRIOR TO SUBMITTAL OF CONCRETE MIXES. IF THE POLISHED CONCRETE CONTRACTOR REQUESTS TO DEVIATE FROM THE REQUIREMENTS OF THIS SCHEDULE, CONTACT THE STRUCTURAL ENGINEER TO REVIEW THE REQUESTS PRIOR TO SUBMISSION OF THE POLISHED CONCRETE MIX(ES). 7. WHEN NOTED IN SCHEDULE, PROVIDE CRYSTALLINE WATERPROOFING ADMIXTURE (XYPEX C-500 OR EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER) AT MANUFACTURER'S RECOMMENDED DOSAGE RATE IN CONCRETE FOR THE FOLLOWING, UNO: WATER/WASTEWATER TANKS, FLUMES, CLARIFIERS, DIGESTERS, RESERVOIRS AND WET WELLS. CONCRETE MIX SCHEDULE CONCRETE USAGE 28-DAY COMPRESSIVE STRENGTH (PSI) FOOTINGS 3,000 SLABS ON GRADE (6 INCHES OR LESS), TIE BEAMS SLABS ON METAL DECK NOTES: MAX CEMENT REPLACEMENT (NOTE 3) 20% MAXIMUM W/CM RATIO 0.55 AIR CONTENT (PERCENT) 0-3 MAXIMUM AGGREGATE SIZE (INCHES) 1.5 NOTES 4,000 4,000 20% 0.48 0-3 1 20% 0.48 0-3 1 4.0 LBS/CYD MACRO-FIBER NOTE: EXISTING STEEL COLUMN AND SLAB ON GRADE NOT SHOWN FOR CLARITY3" CLR, TYPNEW FOOTING PER PLAN (3) #5 x 3'-0" ADHESIVE ANCHOR (8" EMBED) EXISTING SPREAD FOOTING T/FTG PER PLAN T/EX FTG PER PLAN DOWEL CMU REINF INTO EX FTG (EMBED 6")6"2 SLAB ON GRADE SCHEDULE MARK SIZE REINFORCEMENT REMARKS SOG4 4" 6x6-W1.4xW1.4 WWR VAPOR PROTECTION 10 MIL VAPOR RETARDER VAPOR PROTECTION AND SUB-BASE DETAIL VAPOR PROTECTION PER SCHEDULE PLACE WWR REINFORCEMENT 2" CLEAR FROM TOP OF SLAB, UNO SUB-BASE 6x6-W2.9xW2.9 WWRSOG6 6" 10 MIL VAPOR RETARDER NOTES: 1. PROVIDE 6" COMPACTED DRAINAGE FILL SUB-BASE, UNO. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:02 PMS301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S301 1 COLUMN FOOTING SCHEDULE N.T.S.S301 2 WALL FOOTING SCHEDULE N.T.S.S301 6 TYPICAL INTERIOR CMU WALL FOOTING IN EXISTING BUILDING N.T.S.S301 3 TYPICAL NEW-TO-EXISTING SLAB ON GRADE JOINT N.T.S.S301 5 CONCRETE REINFORCEMENT DEVELOPMENT LENGTH AND LAP SPLICE TABLE N.T.S.S301 7 CONCRETE MIX SCHEDULE N.T.S.S301 9 INTERIOR CMU WALL FOOTING IN EXISTING BUILDING N.T.S.S301 8 SLAB-ON-GRADE SCHEDULE NOT USED 2 REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21 1 2 COLUMN & FOOTING FOOTING PER PLAN ANCHOR RODS PER COLUMN SCHED AND COLUMN BASE DETAIL FILL W/ CONCRETE ISOLATION JOINT AT BRACE CONTROL JOINT, TYP COLUMN PER PLAN 1/2" EXP JT MATERIAL T/SLAB PER PLAN T/FTG PER PLAN 3" CLR4" MINBRACE PER PLAN EXTEND ISOLATION JOINT TO ENCOMPASS ENTIRE PORTION OF BRACE AT/BELOW CONCRETE SURFACE ISOLATION JOINT BRACE PER PLAN CONCRETE INFILL CONCRETE INFILL CONCRETE INFILL CONCRETE INFILL 1/2" EXP JT MATERIAL CONTROL JOINT, TYP COLUMN PER PLAN EDGE OF SLAB 1/2" EXP JT MATERIAL EDGE OF SLAB EDGE OF SLAB COLUMN PER PLAN NOTES: COLUMN & FOOTING FOOTING PER PLAN ANCHOR RODS PER COLUMN SCHEDULE AND COLUMN BASE DETAIL FILL W/ CONCRETE ISOLATION JOINT T/SLAB PER PLAN T/FTG PER PLAN 3" CLRCONCRETE INFILL EDGE OF SLAB 1/2" EXP JT MATERIAL CONTROL JOINT, TYP NOTE 4 NOTE 4 NOTE 4 EDGE OF SLAB 1. FOR COLUMNS PLACED AFTER SLAB-ON-GRADE, SIZE ISOLATION JOINT AS REQUIRED TO ALLOW FOR BASE PLATE INSTALLATION AND TIGHTENING OF ANCHOR RODS AND MAINTAIN NOT LESS THAN 4" MINIMUM CLEAR BETWEEN COLUMN AND ISOLATION JOINT. 2. FOR COLUMNS PLACED BEFORE SLAB-ON-GRADE, SIZE ISOLATION JOINT AS REQUIRED TO KEEP ALL ANCHOR RODS WITHIN THE ISOLATION JOINT AND MAINTAIN NOT LESS THAN 4" MINIMUM CLEAR BETWEEN COLUMN AND ISOLATION JOINT. 3. FOR CIRCULAR ISOLATION JOINTS AT PERIMETER AND CORNERS, ANGLE OF INTERSECTION BETWEEN JOINT AND WALL TO BE A MINIMUM OF 90 DEGREES TO PREVENT RETURN OF SLAB BEHIND CIRCULAR ISOLATION JOINT. 4. WHERE EXPANSION JOINT MATERIAL IS REQUIRED BETWEEN THE TYPICAL EDGE OF SLAB-ON-GRADE AND WALL, CONTINUE THE EXPANSION JOINT MATERIAL CONTINUOUS BETWEEN THE INFILL CONCRETE AND WALL ALSO, TYPICAL. OPENING PER PLAN WALL PER PLAN #4 BAR x (OPENING + 3'-0") AT SLAB MID-DEPTH UNO (1) #4 BAR x 2'-6" AT SLAB MID-DEPTH UNO (1) #4 BAR x 2'-6" AT SLAB MID-DEPTH UNO ADDITIONAL REINFORCEMENT NOT REQUIRED AT CJ CJ WALL OPENINGS RE-ENTRANT CORNERS ADDITIONAL REINFORCING NOT REQUIRED AT CJUNOEQUNOEQ2" CLR2" CLREQ EQ SLAB EDGE OR CJ PER PLAN 2" CL R 1 1 1 1 NOTES: 1. WHERE THERE IS INSUFFICIENT ROOM TO INSTALL A STRAIGHT BAR AS SHOWN CENTERED WITH EQUAL LENGTH EACH SIDE OF THE RE-ENTRANT CORNER, PROVIDE BAR WITH A 90- OR 180- DEGREE HOOK INSTALLED ON THE SIDE WITH SHORTER EMBEDMENT. 2. FOR SLABS WITH 2 LAYERS OF REINFORCEMENT, INSTALL ADDITIONAL REINFORCEMENT AT ELEVATION OF TOP LAYER ONLY.2" CLRNOTE 1 NOTE 1 EX PRECAST WALL EX FTG FVNEW COL PER PLAN (2) #5 x 2'-0" ADHESIVE DOWELS (6" EMBED) T/FTG PER PLAN T/SLAB PER PLAN COLUMN FTG PER PLAN6"2 CLEAN SURFACE OF EXISTING FOOTING PRIOR TO PLACEMENT OF NEW FOOTING THICKEN NEW FTG TO MATCH BOT OF EX FTG (3) #5 ADHESIVE ANCHOR (8" EMBED) EXISTING SPREAD FOOTING T/EX FTG PER PLAN EQEQ 1 2 CONT WF REINF PER PLAN NOTE: EXISTING STEEL COLUMN AND SLAB ON GRADE NOT SHOWN FOR CLARITY Ld T/FTG PER PLAN UNIFORMLY SLOPED BASE NOTES: 1. SEE PLAN FOR STEP LOCATIONS AND ELEVATIONS. 2. MAXIMUM SINGLE STEP HEIGHT = 4'-0". FOOTING PER PLAN CONT BARS CONT BARS BARS CONT SPLICE LAP 2H2 (MAX) 2H 1'-0" MIN T/FTG PER PLAN T/FTG PER PLANH2 H1HSPLICE LAP NOTE 4 SLAB DEPTH (IN) DOWEL SIZE AND SPACING 4 DOWEL BAR DIAMETER (IN) TOTAL BAR LENGTH (IN) BAR SPACING (CTR -CTR) (IN) 3/4 16 24 5-6 3/4 16 12 CONTROL JOINT CONSTRUCTION JOINT SLAB ON GRADE PER PLAN 1/4" (+/-) TOOLED JOINT SLAB ON GRADE PER PLAN COAT OR WRAP DOWEL TO PREVENT BOND SMOOTH DOWEL BAR PER TABLE. INSTALL AT MID-DEPTH OF SLAB, UNO.SEE PLANDSEE PLANDD/4APPLY CURING COMPOUND TO FACE OF SLAB AFTER REMOVAL OF EDGE FORM CMU WALL & REINF PER PLAN HOOKED DOWEL, SIZE AND SPACING TO MATCH VERTICAL REINFORCING LAP SPLICE PER MASONRY LAP SPLICE CHART, UNO 1/2" EXP JT MATL, TYP EXIST SLAB FTG PER PLAN 3" CLRT/SLAB PER PLAN #4 x 1'-4" @ 24" OC DRILL & GROUT 0'-8" INTO EXISTING SLAB SAWCUT, REMOVE & REPLACE EXISTING SLAB AS REQUIRED TO CONSTRUCT FOOTING & WALL (SLAB THICKNESS TO MATCH EXISTING) NOTE: REINFORCE NEW SLAB-ON-GRADE CONCRETE WITH WWR PER SLAB ON GRADE SCHEDULE STAIRS BY STAIR MANUFACTURER. COORDINATE LOCATION OF THICKENED SLAB PLACEMENT WITH STAIR MANUFACTURER SUPPORT LAYOUT PRIOR TO PLACEMENT.8"1 2 #5 @ 12" OC EW BOTTOM3" CLRT/FTG PER PLAN MINIMUM 2'-0" WIDE THICKENED SLAB CENTERED ON SUPPORTED ELEMENT, UNO. PROVIDE THICKENED SLAB MINIMUM 1'-0" PAST STAIR SUPPORT EACH SIDE, UNO 2 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:03 PMS302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S. S302 1 COLUMN ISOLATION JOINT AT BRACED FRAME N.T.S.S302 3 TYPICAL STEEL COLUMN ISOLATION JOINT DETAILS N.T.S.S302 2 TYPICAL ADDITIONAL SLAB ON GRADE REINFORCEMENT AT RE-ENTRANT CORNERS N.T.S.S302 4 SECTION N.T.S.S302 6 SECTION N.T.S. S302 8 TYPICAL STEPPED FOOTING N.T.S.S302 9 TYPICAL SLAB ON GRADE JOINTS 1 N.T.S.S302 10 THICKENED SLAB AT STAIRS NOT USED NOT USED 2 2 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDENDUM 1 05/20/2021 2 ADDENDUM 2 07/02/2021 09/16/21 SEE PLAN SEE PLAN #6 BARS @ 8" TRANSVERSE TOP #6 BARS @ 12" TRANSVERSE BOTSEE PLANSEE PLAN (6) #6 BARS LONGITUDINAL TOP (3) #6 BARS LONGITUDINAL BOT (8) #6 BARS LONGITUDINAL TOP (4) #6 BARS LONGITUDINAL BOT SEE PLAN SEE PLAN(6) #6 BARS LONGITUDINAL TOP (3) #6 BARS LONGITUDINAL BOT #6 BARS @ 8" TRANSVERSE TOP #6 BARS @ 12" TRANSVERSE BOT (8) #6 BARS LONGITUDINAL TOP (4) #6 BARS LONGITUDINAL BOT SEE PLAN SEE PLAN Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:03 PMS303 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S303 2 COMBINED FOOTING 2 N.T.S.S303 1 COMBINED FOOTING 1 2 REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21 OPNG OPNG OPNG OPNG CMU WALL REINFORCEMENT SCHEDULE CMUW1 MARK SIZE VERTICAL REINFORCEMENT REMARKS 8" #5 @ 48" OC NOTES: 1. SEE THE STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR REQUIRED HORIZONTAL (BOND BEAM AND JOINT) REINFORCEMENT AND REQUIRED ADDITIONAL VERTICAL REINFORCEMENT. 2. PROVIDE MATCHING HOOKED DOWELS INTO THE FOUNDATION FOR ALL VERTICAL REINFORCEMENT. GROUT SOLID ALL CELLS CONTAINING VERTICAL REINFORCEMENT. 3. WHERE INDICATED, POSITION DBL BAR REINFORCEMENT IN 12" CMU AS SHOWN. USE BAR POSITIONERS AS REQUIRED TO MAINTAIN PROPER ALIGNMENT. TYP BAR PLACEMENT EQEQ8"8" DBL BAR PLACEMENT REBAR POSITIONER CENTERING CLIP CMU CMU VERT REINF VERT REINF REBAR POSITIONER CENTERING CLIP MASONRY REINFORCING STEEL LAP SPLICE CHART BAR SPLICE LENGTHS BAR TYPE 1.0LD #3 20" #4 26" #5 32" #6 39" #7 45" #8 52" #9 58" NOTES: 1. ALL SPLICES ARE TYPE 1.0LD, UNO. 2. BARS LARGER THAN #9 ARE REQUIRED TO BE SPLICED BY MECHANICAL CONNECTORS, UNO. 3. SPLICES BASED ON Fs = 32,000 PSI AND f'm >= 1500 PSI. 4. ALL BARS ARE UNCOATED, UNO. 5. USE EPOXY-COATED BARS ONLY IN PARKING STRUCTURE MASONRY WHERE SPECIFICALLY INDICATED, UNO. TYPE 1.5LD 36" 48" 60" 72" 84" 96" 109" TYPE 1.0LD 29" 39" 48" 58" 68" 77" 87" TYPE 1.5LD 54" 72" 90" 108" 126" 144" 164" UNCOATED BARS EPOXY-COATED BARS NOTES: 1. PROVIDE MINIMUM OF 8" BEARING AT BOND BEAM LINTELS, UNO. 2. PROVIDE FULL HEIGHT VERTICAL JAMB BAR EACH SIDE OF EVERY OPENING. 3. HORIZONTAL REINFORCING TO CONSIST OF 9 GAUGE LADDER TYPE WIRE REINFORCING SPACED AT 16" OC VERTICALLY, UNO. 4. PROVIDE CONTINUOUS BOND BEAM LINTELS OVER ADJACENT SAME-HEIGHT OPENINGS WITH LESS THAN 2'-8" OF MASONRY BETWEEN OPENINGS. 5. FOR OPENINGS THAT INTERRUPT 2 OR MORE REGULARLY SPACED VERTICAL BARS, PROVIDE ONE ADDITIONAL BAR AT 8" OC ADJACENT TO EACH JAMB FOR EVERY 2 BARS INTERRUPTED BY THE OPENING. 6. CONDITION SHOWN ON THIS DETAIL IS FOR BOND BEAM LINTELS. SEE LINTEL BEARING DETAILS FOR BAR PLACEMENT INFORMATION AT STEEL AND PRECAST LINTELS (WHEN PERMITTED). 7. PROVIDE ADDITIONAL CONTINUOUS BOND BEAMS WHERE INDICATED ON THE DRAWINGS. OF END OF WALL OR MOVEMENT JOINT VERTICAL REINFORCING PER CMU WALL REINF SCHEDULE HORIZONTAL REINFORCING SEE NOTE 3 CONTINUOUS BOND BEAM AT TOP OF WALL WITH MINIMUM (1) #5 CONT, UNO (SEE NOTE 7) SEE NOTE 4 NOTE 1, TYP OPENING BAR SEE NOTE 2 PROVIDE DOWELS TO MATCH WALL REINFORCEMENT (LAP SPLICE, TYP) T/FTG T/WALL PLACE BAR WITHIN 8" SEE SEE NOTE 5 SEE NOTE 5 CONTROL JOINT PER TYPICAL CMU WALL JOINT DETAILS AND AS FOLLOWS: PERIMETER AND LOAD BEARING WALLS: EXTEND CJ FROM BOTTOM OF CMU WALL TO BOTTOM OF CONT BOND BEAM AT TOP OF WALL, UNO. INTERIOR NON LOAD BEARING PARTITION WALLS: EXTEND CJ FULL HEIGHT OF WALL, UNO. CORNER INTERSECTION CONTROL JOINT END CMU BOND BEAM UNIT W/ OPEN BOTTOM BOND BEAM REINF CORNER BARS MATCH BOND BEAM REINF (LAP SPLICE) CMU BOND BEAM UNIT W/ OPEN BOTTOM BOND BEAM REINF INTERSECTION BARS MATCH BOND BEAM REINF (LAP SPLICE) VERTICAL REBAR SIZE TO MATCH WALL REINF, TYP VERTICAL REBAR SIZE TO MATCH WALL REINF BOND BEAM REINF TERMINATE 2" BACK FROM CONTROL JOINT EACH SIDE. (EXCEPTION: AT BOND BEAM AT TOP OF PERIMETER AND LOAD-BEARING WALLS STOP CJ AT BOTTOM OF BOND BEAM AND MAINTAIN TOP BOND BEAM AND REINF CONTINUOUS, UNO) PRE-FORMED CONTROL JOINT GASKET IN SASH BLOCK CMU BACKER ROD AND SEALANT EACH SIDE BOND BEAM REINF. TERMINATE 2" BACK FROM END OF WALL VERTICAL REBAR SIZE TO MATCH WALL REINF, TYP BOND BEAM DETAILS CORNER INTERSECTION CONTROL JOINT END JOINT REINFORCEMENT DETAILS PREFABRICATED L-SHAPE JOINT REINF AT WALL CORNER. MATCH CONTINUOUS JOINT REINF AND LAP SPLICE 6" MIN. PREFABRICATED T-SHAPE JOINT REINF AT WALL INTERSECTION. MATCH CONTINUOUS JOINT REINF AND LAP SPLICE 6" MIN. PRE-FORMED CONTROL JOINT GASKET IN SASH BLOCK CMU JOINT REINF. TERMINATE 2" BACK FROM CONTROL JOINT EACH SIDE JOINT REINF. TERMINATE 2" BACK FROM END OF WALL BACKER ROD AND SEALANT EACH SIDE VERTICAL REBAR SIZE TO MATCH WALL REINF, TYP VERTICAL REBAR SIZE TO MATCH WALL REINF VERTICAL REBAR SIZE TO MATCH WALL REINF, TYP CUT CMU WEBS AND FACE SO GROUT AND REINF ARE UNINTERRUPTED, TYP NOTES: 1. VERTICAL REINFORCEMENT INDICATED ON THIS DETAIL IS REQUIRED IN ADDITION TO SCHEDULED VERTICAL REINFORCEMENT, UNLESS SCHEDULED REINFORCEMENT ALREADY OCCURS AT THE INDICATED LOCATIONS. 2. PROVIDE LAPPED DOWELS INTO FOUNDATION AT ALL VERTICAL REINFORCEMENT. 3. PROVIDE HORIZONTAL JOINT REINFORCEMENT AND BOND BEAM REINFORCEMENT IN CMU WALLS IN ACCORDANCE WITH THE PROJECT DRAWINGS AND SPECIFICATIONS. REINFORCED CMU LINTEL MIN, UNO 8" BEARINGREINFORCED CMU LINTEL PER PLAN PROVIDE (1) FULL-HEIGHT VERT BAR EACH SIDE OF OPENING IN SOLID- GROUTED CORES. RUN REINFORCING STEEL CONT. THROUGH LINTEL, FULL HEIGHT OF WALL. CMU WALL PER PLAN NOTE 3 NOTES: 1. INSTALL LINTELS TO PROVIDE EQUAL BEARING LENGTH EACH SIDE OF OPENING, UNO. 2. VERTICAL BARS SHALL BE THE SAME SIZE AS TYPICAL VERTICAL WALL REINFORCEMENT, UNO. 3. FOR OPENINGS THAT INTERRUPT 2 OR MORE REGULARLY SPACED VERTICAL BARS, PROVIDE ONE ADDITIONAL FULL-HEIGHT BAR @ 8" OC ADJACENT TO EACH JAMB FOR EVERY 2 BARS INTERRUPTED BY THE OPENING. 4. AT CMU LINTEL BEARING, CUT OPENING THROUGH BOTTOM OF U-SHAPE LINTEL BLOCK AS REQUIRED TO ALLOW REINFORCEMENT AND GROUT PLACEMENT AT LINTEL BEARING. NOTE 4 LINTEL SCHEDULE MARK SECTION CLEAR OPENING TYPE NOTES L1 L2 LINTEL SCHEDULE NOTES: 1. ALL LINTELS BEAR 0'-8" ONTO SUPPORTING WALLS, UNO. 2. ALL STEEL LINTELS AND SHELF ANGLES IN EXTERIOR WALLS SHALL BE GALVANIZED. 3. BOTTOM PLATES SHALL EXTEND THE FULL LENGTH OF THE LINTEL, INCLUDING BEARING LENGTH, UNO. 4. AT CMU INFILL (SOAPS) AT STEEL LINTELS, PROVIDE METAL ANCHORAGE AT EVERY COURSE @ 16" OC TO TIE CMU TO STEEL. TYPES: A U-SHAPE LINTEL BLOCK W/ (2) #5 CONT BARS SOLID GROUTED COURSES OF BLOCK. POUR GROUT AT SAME TIME AS LINTEL BLOCK 8" W X 8" H (NOMINAL) PER ARCH, 5'-0" MAX A 8" W X 24" H (NOMINAL) PER ARCH A H3"W Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:04 PMS401 CMU SCHEDULES, SECTIONS AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S401 1 CMU WALL REINFORCEMENT SCHEDULE N.T.S.S401 5 TYPICAL REBAR POSITIONERS N.T.S.S401 2 MASONRY LAP SPLICE TABLE N.T.S.S401 3 TYPICAL REINFORCING AT CMU WALLS N.T.S.S401 4 TYPICAL CMU WALL JOINT DETAILS N.T.S.S401 7 TYPICAL LINTEL BEARING DETAILS N.T.S.S401 6 LINTEL SCHEDULE REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 BENT PL1/4 x T x (EOS DIM -1") CONT WITH 1/2" DIA X 6" HEADED STUDS @ 1'-6" OC #4 @ 1'-6" OC HOOKED BARS EOS <= 1'-3" PER PLAN EOS BENT PL1/4 x T x (EOS DIM -1") CONT WITH 1/2" DIA HEADED STUDS @ 1'-6" OC L3x3x1/4 BRACE @ 4'-0" OC MAX L3x3x1/4 KICKER @ 4'-0" OC MAX 6" PER PLAN EOS EOS > 1'-3" UP TO 2'-6" (DECK SPAN PERPENDICULAR) 6" CLR WHERE WALL SYSTEM TERMINATES AT UNDERSIDE OF SLAB 1" CLR WHERE WALL SYSTEM BYPASSES SLAB EDGE L3x3x1/4 BRACE @ 4'-0" OC MAX L3x3x1/4 KICKER @ 4'-0" OC MAX 6" PER PLAN EOS EOS > 1'-3" UP TO 2'-6" (DECK SPAN PARALLEL) 6" CLR WHERE WALL SYSTEM TERMINATES AT UNDERSIDE OF SLAB 1" CLR WHERE WALL SYSTEM BYPASSES SLAB EDGE 1 2 MIN 3/16 3 MIN TYPTT BENT PL1/4 x T x (EOS DIM -1") CONT WITH 1/2" DIA X 6" HEADED STUDS @ 1'-6" OC L4x4x1/4 x 1'-3" AT KICKER LOCATIONS. ANCHOR TO SLAB WITH (2) 1/2" DIA EXPANSION ANCHORS CENTERED ON DECK FLUTE, 3" EMBEDMENT, TYP. INCREASE ANGLE LENGTH AS NECESSARY FOR SKEWED CONDITIONS.T#4 @ 1'-6" OC HOOKED BARS NOTES: 1. FOR EDGE OF SLAB DISTANCES EXCEEDING LIMITS SHOWN, CONTACT STRUCTURAL ENGINEER FOR REVIEW AND DO NOT FABRICATE WITHOUT PRIOR REVIEW AND APPROVAL. 3/16 2-12 TYP 3/16 2-12 TYP 1" CLR#4 CONT 2'-0"1" CLR2'-0"1" CLR2'-0" #4 @ 1'-6" OC HOOKED BARS #4 CONT #4 CONT 1 1/2"1 1/2" 1 1/2"1" FACE OF EX CONSTRUCTION 1" FACE OF EX CONSTRUCTION 1" FACE OF EX CONSTRUCTION SLAB ON METAL DECK SCHEDULE S1 MARK SLAB REINFORCING NOTES 6x6-W1.4xW1.4 WWR NOTES: 1. CONCRETE TO BE NORMAL WEIGHT, UNO. 2. FASTEN THROUGH MULTIPLE SHEETS AT ALL END AND SIDE LAPS. 3. END LAPS SHALL OCCUR ONLY AT SUPPORT POINTS. 4. DECK SHALL BE INSTALLED IN A MINIMUM THREE SPAN CONDITION WHEREVER POSSIBLE. WHERE THREE SPAN CONDITION IS NOT POSSIBLE, NOTIFY STRUCTURAL ENGINEER PRIOR TO FABRICATION OF DECK SO THAT EVALUATION OF THE LESSER SPAN CONDITION(S) CAN BE PERFORMED. 5. FOR DECK SPANS 5'-0" OR LESS, PROVIDE ONE SIDELAP FASTENER AT MID-SPAN OF EACH JOIST OR BEAM SPACE. FOR DECK SPANS EXCEEDING 5'-0", PROVIDE SIDELAP FASTENERS AT 3'-0" OC, MAX. USE DECK MANUFACTURER'S RECOMMENDED PUNCHED SIDELAPS FOR COMPOSITE DECK AND NON-NESTING FORM DECK,UNO. USE #10 TEK SCREWS AT DECK WITH NESTED SIDELAPS, UNO. 6. PROVIDE DECK WITH ALL PROPERTIES MEETING OR EXCEEDING THE INDICATED BASIS OF DESIGN DECK. 1 1/2" DECK HEIGHT 20 GA GAUGE COMPOSITE TYPE GALV FINISH SUPPORT FASTENER TYPE 5/8" DIA PUDDLE WELDS SUPPORT FASTENER PATTERN 36-4 SIDELAP FASTENER TYPE SEE NOTE 5 SUPPORT FASTENER TYPE PER SCHEDULE SIDELAP FASTENER TYPE AND PATTERN PER SCHEDULE BEAM OR JOIST PROVIDE SUPPORT FASTENERS AT PARALLEL PERIMETER FRAMING AT SAME SPACING AS ADJACENT SIDELAP FASTENERS SHEE T WI D T H SUPP O RT FAST EN E R PAT T ERN PE R SC HEDU L E SE E P L A N SEE PL AN SE E PL A N 36" COVERAGE 36/4 PATTERN FASTENER PATTERN DIAGRAM SIDELAP FASTENER PATTERN SEE NOTE 5 SLAB THICKNESS DEFINITION AND REINF PLACEMENT SUPPORT FASTENER PATTERN DEFINITION COMPOSITE DECK: PLACE REINF 3/4" CLEAR FROM TOP OF SLAB FLOOR DECK 4" SLAB T TSUPPORT FASTENERS @ 12" OC MAX PERIMETER EDGE FASTENING NON-COMPOSITE FORM DECK: PLACE REINF AT MID-DEPTH OF CONCRETE ABOVE DECK FLUTES NOTE: SUPPORT ALL REINF ON CHAIRS TO MAINTAIN PROPER POSITION THROUGHOUT CONCRETE PLACEMENT. 30" COVERAGE 30/4 PATTERN BASIS OF DESIGN DECK (NOTE 6) VULCRAFT 1.5VL2050 KSI YIELD STRENGTH Fy OPNG/ DEPRESSION 2'-0" TYP2" CLR, TYP (1) #3, TYP PROVIDE STANDARD HOOK IF OPENING IS LESS THAN 2'-0" FROM EDGE OF SLAB, TYP OPNG/ DEPRESSION 2" CLR, TYP (1) BENT #4 MIN, TYP SMALL OPENING LARGE OPENING NOTES: 1. VERIFY ALL OPENINGS (INCLUDING PIPING/ CONDUIT PENETRATIONS) NOT SHOWN ON STRUCTURAL DRAWINGS WITH THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. 2. REINFORCEMENT SHOWN ON THIS DETAIL IS IN ADDITION TO ALL OTHER INDICATED REINFORCEMENT, UNO. 3. CONCRETE CONTRACTOR SHALL SECURELY CHAIR ALL REINFORCEMENT PRIOR TO CONCRETE PLACEMENT AND MAINTAIN PROPER REINFORCEMENT POSITIONING THROUGHOUT THE CONCRETE PLACEMENT. (2'-0" x 2'-0" MAX) (LARGER THAN 2'-0" x 2'-0", UNO)OPENING WIDTHOR DIAMETER + 4"2'-0"2'-0"135.00°135.00°BENT BAR DIMENSIONS ADDITIONAL REINFORCEMENT PLACEMENT AT SLABS ON METAL DECK WITH WWR TIE ADDITIONAL REINFORCEMENT TO BOTTOM OF WWR #4 x 4'-0", TYP 1 1 EQ EQ BARS ON BOTTOM LAYER ARE SHOWN DASHED FOR CLARITY ADDITIONAL REINFORCEMENT PLACEMENT AT SLABS ON METAL DECK WITHOUT WWR ADDITIONAL REINFORCEMENT 1" CLRREINFORCEMENT AT OPENING/DEPRESSION 3"OPENING PER PLAN WALL PER PLAN (2) #4 BAR x 2'-6" TYP (2) #4 BAR x 2'-6" TYP WALL OPENINGSRE-ENTRANT CORNERS EQ EQ2" CLR3" 2 " CLR SLAB EDGE OR CONSTRUCTION JOINT, TYP 2" C LR 3"1 1 1 1 NOTES: 1. WHERE ANY CONDITION DOES NOT CONFORM TO THE LIMITS SHOWN, USE A PERMISSIBLE REINFORCED OR FRAMED OPENING. 2. ROUND OPENINGS MAY BE BLOCKED OUT PRIOR TO CONCRETE PLACEMENT OR CORED AFTER PLACEMENT. 3. SQUARE OR RECTANGULAR OPENINGS MUST BE BLOCKED OUT PRIOR TO CONCRETE PLACEMENT. POST-INSTALLATION CUTTING OF SLAB CONCRETE FOR SQUARE OR RECTANGULAR OPENINGS IS NOT PERMITTED. 4. DO NOT CUT DECK OR OPENING UNTIL CONCRETE SLAB HAS REACHED A MINIMUM OF 75% OF ITS 28-DAY COMPRESSIVE STRENGTH. 5. NOT MORE THAN ONE SET OF GROUPED PENETRATIONS ALIGNED PARALLEL TO DECK SPAN IN ANY SINGLE FRAMING SPACEFRAMING PER PLAN8" DIA OR 8"x8" MAX OPENING BTWN OPNGSNOT LESS THAN4'-0" CLEAR MINISOLATED PENETRATIONS BTWN OPNGSNOT LESS THAN4'-0" CLEAR MINGROUPED PENETRATIONS ALIGNED PARALLEL TO DECK SPAN SEE NOTE 5 1'-6" MAX 2" MIN 8" MAXBTWN GROUPSNOT LESS THAN4'-0" CLEAR MIN8" MAXGROUPED PENETRATIONS NOT ALIGNED PARALLEL TO DECK SPAN UNREINFORCED OPENINGS NOTES: 1. WHERE ANY CONDITION DOES NOT CONFORM TO THE LIMITS SHOWN USE A PERMISSIBLE ANGLE- FRAMED OR BEAM-FRAMED OPENING. 2. FORM/BLOCK OUT OPENING BUT DO NOT CUT DECK UNTIL CONCRETE HAS REACHED ITS 28-DAY STRENGTH. 3. NOT MORE THAN ONE SUCH OPENING PARALLEL TO DECK SPAN IN ANY SINGLE FRAMING SPACE. REINFORCED OPENINGS (2) #4 @ 3" OC CHAIRED 3/4" ABOVE SURFACE OF DECK (2) #4 PLACED IN FIRST FULL DECK FLUTE EACH SIDE OF OPNG CHAIRED 3/4" ABOVE SURFACE OF DECK FLUTE FRAMING PER PLANFRAMING PER PLANFRAMING PER PLANFRAMING PER PLANFRAMING PER PLANDECK SPAN 8" MAX 2" MIN8" DIA OR 8"x8" MAX OPENING TYP 3'-0" MIN 3'-0" MAX FRAMING PER PLANTYP3'-0" MIN1'-6" MAX ADJACENT OPENINGNOT LESS THAN4'-0" TO ANYSEE NOTE 3 2" TYP CENTERLINE OF SUPPORT 2"2" COPE ANGLE TO BEAR ON TOP OF SUPPORT FORM EDGE OF OPENING AS REQ'D3'-0" MAXANGLE-FRAME OPENINGS PER PLAN OPENING DECK SPAN WELDED ANGLE FRAME FOR DECK SPAN UP TO 6'-0", USE L4X4X1/4 FOR DECK SPAN >6'-0" UP TO 10'-0", USE L6X4X5/16 (LLV) NOTES: 1. WHERE ANY CONDITION DOES NOT CONFORM TO THE LIMITS SHOWN USE A PERMISSIBLE BEAM-FRAMED OPENING. 2. FORM/BLOCK OUT OPENING BUT DO NOT CUT DECK UNTIL CONCRETE HAS REACHED A MINIMUM O F75% OF ITS 28-DAY STRENGTH -OR -DECK SUPPLIER PROVIDE GAUGE METAL POUR STOP AROUND ENTIRE PERIMETER OF OPENING. 8" DIA OR 8"x8" MAX OPENING 8" DIA OR 8"x8" MAX OPENING DECK SPAN DECK SPAN FRAMING PER PLANDECK SPAN FRAMING PER PLANFRAMING PER PLANDECK SPAN NOT LESS THAN 2'-0" CLEAR TO SLAB EDGE, TYP NOT LESS THAN 2'-0" CLEAR TO SLAB EDGE, TYP NOT LESS THAN 2'-0" CLEAR TO SLAB EDGE, TYP CONTRACTOR NOTE: IF ANY CONDITIONS ARE ENCOUNTERED THAT PREVENT INSTALLATION OF OPENINGS PER THE DETAILS ABOVE, CONTACT THE STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF SLAB CONCRETE FOR FURTHER INSTRUCTION. INSTALLATION OF OPENINGS OTHER THAN AS DIRECTED BY THE STRUCTURAL ENGINEER WILL BE AT THE CONTRACTOR'S RISK. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:05 PMS501 STEEL SCHEDULES, SECTIONS, AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S501 2 PERIMETER EDGE OF SLAB SUPPORT N.T.S.S501 1 SLAB ON METAL DECK SCHEDULE N.T.S. S501 3 TYPICAL ADDITIONAL SLAB ON METAL DECK REINFORCEMENT AT RE-ENTRANT CORNERS N.T.S.S501 4 TYPICAL SLAB ON METAL DECK OPENING DETAILS REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 OPNG OPNG #4 x 5'-0" @ 2'-0" OC CENTER OVER GIRDER DECK GIRDER FILLER AS REQUIRED, TYP FLOOR SLAB PER PLAN FLOOR GIRDER PER PLANTO REBAR1" CLRT/BEAM PER PLAN HEADED STUDS WHERE INDICATED TO REBAR1" CLR#4 X 5'-0" @ 2'-0" OC, CENTER OVER BEAM HEADED STUDS WHERE INDICATED COLUMN BEYOND FLOOR BEAM PER PLAN T/BEAM PER PLAN BEAMS AT INTERIOR COLUMN LINES GIRDERS WITH FRAMING ON BOTH SIDES NOTES: 1. REINFORCEMENT SHOWN ON THIS DETAIL IS IN ADDITION TO ALL OTHER INDICATED REINFORCEMENT, UNO. 2. CONCRETE CONTRACTOR SHALL SECURELY CHAIR ALL REINFORCEMENT PRIOR TO CONCRETE PLACEMENT AND MAINTAIN PROPER REINFORCEMENT POSITIONING THROUGHOUT THE CONCRETE PLACEMENT.1/2"COPE VERT LEG AT CORNER L2-1/2x2-1/2x3/16 3/163/16 3/16 1/2"PLAN AT INSIDE CORNER WITH JOIST SUPPORTED EDGE MEMBER PLAN AT CORNER WITH BEAM SUPPORTED EDGE MEMBER L2 1/2 x 2 1/2 x 3/16 3/16 3/163/16 L2-1/2x2-1/2x3/16 x 0'-4" FIELD WELD TO COLUMN END PLATE 1/2"COPE HORIZONTAL LEG AT COLUMN HORIZ AND VERT LEG L2-1/2x2-1/2x3/16 x 0'-4" FIELD WELD TO COLUMN END PLATE COPE HORIZONTAL LEG AT COLUMN HORIZ AND VERT LEG PLAN AT CORNER WITH JOIST SUPPORTED EDGE MEMBER HORIZ AND VERT LEG COPE HORIZONTAL LEG AT COLUMN 3/16 L2-1/2x2-1/2x3/16 3/16 PLAN AT BEAM SUPPORTED EDGE MEMBER PLAN AT JOIST SUPPORTED EDGE MEMBER 3/16 TYP 3/16 3/16 TYP HORIZ AND VERT LEG COPE HORIZONTAL LEG AT COLUMN L2-1/2x2-1/2x3/16 1/2" 1/2" PLAN PER PLANPERPLAN PER PLANPERPLANPERPLAN PER PLAN PER PLAN PER HORIZ AND VERT LEG SLAB ON METAL DECK PER PLAN 3/16 2-12 BENT PL TO CONT PL CONT BENT PL 1/4 x 4 x T T/SLAB PER PLAN CMU WALL PER PLAN CONT PL1/4 x 6 W/ 1/2" DIA x 4" STUDS @ 16" OC. EMBED IN SOLID- GROUTED CMU. PERIMETER FASTENERS PER STEEL DECK SCHEDULE CONT BOND BEAM W/ (1) #5 BAR TNOTES: 1. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. THIS DETAIL APPLIES FOR DECK PERPENDICULAR, PARALLEL AND SKEWED TO PERIMETER WALL, UNO. SEE PLANS FOR DECK SPAN DIRECTION. CAP PL1/8, MIN RECTANGULAR HSS PIPE OR HSS RECTANGULAR HSS CAP PL1/8, MIN BEAM COLUMN / BRACE INTERSECTION 1/8 1/8 1/8 CAP PL1/8, MIN NOTES: 1. PROVIDE CAP PLATES AT ALL EXPOSED ENDS OF ALL HSS AND PIPE MEMBERS. 2. PROVIDE CAP PLATES FOR ALL COLUMNS WHETHER EXPOSED TO VIEW OR NOT. PIPE / ROUND HSS 1/8 CAP PL1/8, MIN PIPE / ROUND HSS CAP PL1/8, MIN 1/8 CMU WALL PER PLAN BEAM PER PLAN GROUT SOLID AFTER SETTING BEAM PL3/4x6x1'-0" AT 8" CMU W/ (2) 1/2" DIA X 6" HEADED STUDS POSITION EDGE OF PLATE FLUSH WITH CMU WALL FACE AT BEAM SIDE AS SHOWN GROUT SOLID BELOW BEAM BEARING 24" (MIN) WIDE X FULL HEIGHT OF WALL, CENTERED UNDER BEAM 2 1/2" 3/16 2 3/16 2 STIFFENER PL 3/8 EACH SIDE BEAM PER PLAN CAP PL 3/4 (4) 3/4" DIA A325 BOLTS COLUMN PER PLAN SEE PLAN NOTE 2 JOIST OR BEAM SPACING PER PLAN NOTE 3, TYP MECHANICAL RTU ON PREFABRICATED CURB (BY MECH CONTRACTOR) L4x4x1/4 FRAME UNDER FULL PERIMETER OF MECH UNIT CURB AND AS REQUIRED FOR DECK SUPPORT AT OPENINGS (SEE NOTE 2) JOIST OR BEAM SPACING PER PLAN 3/16 2 MIN TYP 3/16 TYP FRAME MEMBERS WELD DETAIL 1/2" MAX COPE DETAIL RTU WITH LONG DIRECTION PERPENDICULAR TO FRAMING 6'-0" OC MAXNOTE 4NOTES: 1. COORDINATE UNIT SIZE, LOCATION AND REQUIRED OPENINGS WITH MECHANICAL CONTRACTOR PRIOR TO FABRICATION. FASTEN DECK TO OPENING FRAME @ 6" OC MAX AROUND UNIT PERIMETER AND AROUND PERIMETER OF ALL OPENINGS. 2. PROVIDE SUPPLEMENTAL DECK SUPPORT ANGLE AT OPENINGS IF DECK CANTILEVER SPAN EXCEEDS 1'-0". 3. FOR FRAME ANGLE BEARING LOCATIONS ON STEEL JOISTS THAT DO NOT OCCUR AT PANEL POINTS, SEE "TYPICAL JOIST REINFORCING DETAIL" FOR REINFORCING REQUIREMENTS. 4. PROVIDE INDICATED RTU SUPPORT FRAMING NOT TO EXCEED SPACING INDICATED SPANNING BETWEEN ADJACENT ROOF FRAMING MEMBERS. COPE AND WELD DETAIL AT INTERIOR FRAMING 1/2" MAX INTERIOR FRAMING MEMBER 3/163/16 RTU CURB RTU CURB SUPPORTING FRAMING, TYP CONNECTION OF RTU CURB TO SUPPORTING FRAMING PER MECHANICAL CONTRACTOR. PROVIDE NON-COMBUSTIBLE SHIMS/BLOCKING AS REQUIRED TO MAINTAIN UNIFORM BEARING ON SUPPORTING FRAMING, TYP. BLOCKING/SHIMMING UNDER RTU CURB STEEL JOIST OR BEAM PER PLAN, TYP EXISTING STEEL FRAMING PER PLAN (FIELD VERIFY) SPACING PER PLAN FRAMING FRAMING PER PLAN OPENING FRAMING WELD DETAILS 1/4 L6X4X3/8 (LLV) FRAME, UNO INSTALL TIGHT TO EXISTING SLAB ON METAL DECK 1/2" MAX1" MAX 1" MIN1/2" MAX1/4 RADIUS COPE -NO SHARP CORNERS OPENING FRAMING TIGHT TO SLAB ON METAL DECK 3/8" GUSSET PLATE SLAB ON METAL DECK PER PLAN FRAMING PER PLAN 3/8" GUSSET PLATE 1/4 OPENING FRAME MEMBERS (FIELD VERIFY) CONTRACTOR NOTE: VERIFY SIZE AND LOCATION OF OPENINGS WITH TRADE(S) REQUIRING OPENINGS PRIOR TO INSTALLATION OF OPENING FRAMING. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:07 PMS502 STEEL SCHEDULES, SECTIONS, AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S502 1 TYPICAL SLAB ON METAL DECK REINFORCING OVER INTERIOR GIRDERS AND BEAMS AT INTERIOR COLUMN LINES N.T.S.S502 2 TYPICAL EDGE ANGLE / BENT PLATE SUPPORT AT COLUMNS N.T.S.S502 5 TYPICAL SLAB SUPPORT ON PERIMETER CMU WALL N.T.S.S502 4 TYPICAL HSS / PIPE CLOSURE PLATE DETAIL N.T.S.S502 3 TYPICAL BEAM BEARING ON (PERPENDICULAR TO) CMU WALL N.T.S.S502 6 TYPICAL CANTILEVER BEAM BEARING N.T.S.S502 7 TYPICAL RTU SUPPORT N.T.S.S502 8 TYPICAL SLAB ON METAL DECK OPENING (EXISTING FRAMING) REVISION SCHEDULE NO. DESCRIPTION DATE 09/16/21 T/SLAB T/SLAB 100' - 0" 100' - 0" T/STL MEZZ T/STL MEZZ 113' - 8" 113' - 8" Column Locations A.1-1.1 A.1-1.6 A.8-1.1 A.8-1.6 B.9-1.1 B.9-1.4 C.3-1.2 C.3-1.6 C.6-1.3 C.6-1.6 A.1-E2 C.6-E2HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16HSS6X6X5/16BP1 BP1 BP1 BP1 BP1 BP1BP1BP1BP1 BP1HSS6X6X5/16HSS6X6X5/16BP1 BP1 BASE PLATE PER COLUMN SCHEDULE COLUMN PER PLAN 5/16 TOP NUTS / WASHERS NON-SHRINK GROUTANCHOR RODS PER COLUMN SCHEDULE PLAN SECTION HEX NUT (NO WASHER) TACK WELD NUT TO ANCHOR ROD, TYPPROJECTION PERNOTES: 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE SUFFICIENT TEMPORARY SUPPORT OF COLUMN BASE PLATES USING LEVELING PLATES, LEVELING NUTS / WASHERS OR STEEL SHIMS (OR COMBINATION THEREOF) PRIOR TO PLACEMENT AND CURING OF NON-SHRINK GROUT. SHIMS AND LEVELING NUTS / WASHERS E EQ EQ E B E EQ EQ ENSCHEDULEPER SCHEDULELENGTHEMBEDTHREADEDANCHOR ROD PER SCHEDULE PLATE WASHER W/ STANDARD HOLES UNO AT TOP SIDE OF BASE PLATE (USE LARGER PLATE WHERE INDICATED ON COLUMN SCHEDULE OR ANCHOR ROD TABLE) BASE PLATE PER SCHEDULE NOTES: 1. THIS DETAIL APPLIES AT ALL COLUMN ANCHOR RODS AT BRACED FRAMES AND MOMENT FRAMES UNO. PLATE WASHER DIMENSIONS ANCHOR ROD DIA <= 3/4" 1" REQD PLATE WASHER 1/4x2-1/2x2-1/2 3/8x3-1/2x3-1/2 WELD SIZE 1/4" 1/4" SEE TABLE FOR FILLET WELD SIZE THREADED PROJECTION PER COLUMN / ANCHOR ROD SCHEDULE HEX NUT & WASHER HEX NUT TACK WELD SEE COLUMN / BASE PLATE SCHEDULE FOR REQUIRED DIAMETER, QUANTITY, AND LAYOUT TOP OF CONCRETE FOR COLUMNS TO HAVE NON-SHRINK GROUT BASE, PROVIDE LEVELING NUTS, WASHERS AND SHIMS AS REQUIRED TO SAFELY PLUMB AND SUPPORT THE COLUMN UNTIL GROUT HAS ATTAINED ITS 28-DAY COMPRESSIVE STRENGTH PER COLUMN / ANCHOREMBEDMENT LENGTHROD SCHEDULENOTE: USE WELDED PLATE WASHERS AT COLUMNS WHERE SPECIFICALLY INDICATED.1/2" COLUMN BASE PLATE SCHEDULE MARK PLATE SIZE BP1 B" X N" X T" ANCHOR RODS QTY DIA REMARKS 12" X 12" X 3/4" 4 3/4" EMBED LENGTH 12" SEE DETAIL ANCHOR ROD TABLE ANCHOR ROD DIA BASEPLATE HOLE DIA 3/4" MINIMUM WASHER SIZE MINIMUM WASHER THICKNESS MINIMUM PROJ ABOVE T/CONC NON-SHRINK GROUT BED THK 1 5/16" 2" 1/4" 7" 2" MIN EDGE DISTANCE, E 1 1/2" NOTES: 1. ANCHOR RODS ARE ASTM F1554 GR. 36 UNO. 2. PROVIDE WELDED PLATE WASHERS IN ACCORDANCE WITH TYPICAL DETAIL AT ALL STEEL BRACED FRAMES AND MOMENT FRAMES, UNO. /3 S503 OF PANEL POINT STEEL JOIST PER PLAN ROOF TOPLOADIF THIS DIMENSION IS MORE THAN 3" ADD REINFORCING AS SHOWN. WELD TO TOP AND BOTTOM CHORDS (2) L2x2x3/16 3/16 3 SIDES, TYP (2) L2x2x3/16 DECK PER PLAN STEEL JOIST PER PLAN HANGINGLOAD3/16 3 SIDES, TYP OF PANEL POINT NOTE 1 DECK PER PLAN NOTES 1, 2 NOTES: 1. PROVIDE REINFORCING AS SHOWN FOR ALL CONCENTRATED LOADS GREATER THAN 100 LBS APPLIED TO UNTOPPED DECK OR DIRECTLY TO STEEL JOIST. IF THE TOTAL WEIGHT OF MULTIPLE CONCENTRATED LOADS APPLIED IN A SINGLE PANEL BETWEEN PANEL POINTS EXCEEDS 100 LBS, PROVIDE REINFORCING AS SHOWN. 2. REINFORCING AS SHOWN IS NOT REQUIRED FOR LOADS APPLIED TO TOP SURFACE OF SLABS ON METAL DECK, UNO. 3. FOR EXISTING JOISTS, FIELD VERIFY INSTALLATION CAN BE PERFORMED AS INDICATED. NOTIFY STRUCTURAL ENGINEER TO COORDINATE ALTERNATE REINFORCEMENT DETAIL(S) IF EXISTING JOIST MEMBER LAYOUT WILL NOT PERMIT INSTALLATION AS SHOWN. IF THIS DIMENSION IS MORE THAN 3" ADD REINFORCING AS SHOWN. WELD TO TOP AND BOTTOM CHORDS Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:08 PMS503 STEEL COLUMN SCHEDULE AND BASE PLATE DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 COLUMN SCHEDULE N.T.S.S503 3 TYPICAL HSS COLUMN BASE DETAIL N.T.S.S503 2 TYPICAL WELDED PLATE WASHER DETAIL N.T.S.S503 4 TYPICAL COLUMN ANCHOR ROD DETAIL N.T.S.S503 1 COLUMN BASE PLATE SCHEDULE AND ANCHOR ROD TABLE T/SLAB T/SLAB N.T.S.S503 5 TYPICAL JOIST REINFORCING DETAIL (CONCENTRATED LOAD NOT AT PANEL POINT) 2 2 REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21 T/SLAB 100' -0" T/STL MEZZ 113' -8" E2 HSS6X6X5/16HSS6X6X5/16H S S 4 X 4 X 5/1 6 15' - 1 3/4" NEW SOMD PER PLAN EX SOG S504 3 S504 4 WP WP FTG PER PLAN, TYP 1.6 2 NEW CMU WALL PER PLAN BEAM PER PLAN 2 T/SLAB 100' -0" T/STL MEZZ 113' -8" E2 H S S 4 X 4 X 5 /1 6HSS6X6X5/16HSS6X6X5/16SOMD PER PLAN EX SOG S504 4 S504 3 WP WP FTG PER PLAN, TYP 15' - 1 3/4" 1.6 NEW CMU WALL PER PLAN BEAM PER PLAN 2 COLUMN PER PLAN ERECTION BOLT OR PIN ADDL PLATE AS REQD TO PROVIDE ADEQUATE GUSSET PLATE WELD PL1/2" (MIN) S L BOTH SIDES OF GUSSET REQUIRED WELD SIZE AND LENGTH (S & L) PER FABRICATOR TUBE BRACE MEMBER (SLOT TUBE AT GUSSET) WP TYP1" MIN,SETBACK,TYP1" WE LD 1" CLR, MIN WP COLUMN PER PLAN SHEAR PLATE CONN. SEE BRACING ELEVATIONS FOR DESIGN FORCES, TYP ERECTION BOLT OR PIN TUBE BRACE MEMBER (SLOT TUBE AT GUSSET) PL1/2" (MIN) BEAM PER PLAN BOTH SIDES OF GUSSET REQUIRED WELD SIZE AND LENGTH (S & L) PER FABRICATOR S L1"WELDSETBACK,TYPMIN 1" CLR TYP1" MI N, Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 05/20/2021 7/2/2021 5:07:08 PMS504 BRACED FRAME ELEVATIONS AND DETAILS 2021.00173 07/02/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 N.T.S.S504 1 BRACED FRAME -LINE C.9 N.T.S.S504 2 BRACED FRAME -LINE A.1 N.T.S.S504 3 BRACE DETAIL N.T.S.S504 4 BRACE DETAIL REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 09/16/21