Loading...
HomeMy WebLinkAboutA000 - Wall TypesB2 B3 B6 B1 B1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED B METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL TRACK SEALANT AND BACKER ROD; BOTH SIDES, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL DEFLECTION TRACK LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND B2S B3S B6S B8 9 -1/4"8" B8S SEALANT AND BACKER ROD; BOTH SIDES, CONT. NON- RATED NA NON- RATED NA NON- RATED NA NON- RATED NA WALL TYPE SYMBOL STRUCTURAL CORE SIZE Y6S WALL TYPE DESIGNATION ACOUSTICAL ATTENUATION REQ'D REFERENCE A001 FOR WALL TYPE DESCRIPTIONS A. ALL WALLS ARE TO BE TYPE 'B3S' U.N.O. B. PARTITION SYMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN PROVIDED FOR AREA. C. REFER TO FINISH PLANS FOR WALL FINISH, BASE, AND CEILING INFORMATION. D. REFER TO WALL SECTIONS FOR EXTERIOR WALL CONSTRUCTION. E. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH PLUMBING FIXTURES AND WITHIN 4'-0 OF DRINKING FOUNTAINS / WATER COOLERS, U.N.O. F. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND ABOVE CEILINGS. G. PROVIDE FIRE RESISTIVE RATED GYPSUM WALL BOARD AT ALL RATED ASSEMBLIES TO MEET ASSEMBLY REQUIREMENTS. H. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL RATING AT ALL PENETRATIONS AND AT HEAD/FLOOR INTERSECTIONS WITH RATED ASSEMBLIES. I. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD, PENETRATIONS, AND ADDITIONAL SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED WALLS. J. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS SCHEDULED TO HAVE CERAMIC TILE. K. FRAME DOOR OPENINGS 4" FROM FACE OF PERPENDICULAR WALL ON HINGE SIDE AND 1'-6" MIN. FROM FACE OF PERP. WALL ON LATCH SIDE, UNLESS NOTED OTHERWISE. L. PROVIDE GYPSUM BOARD CONTROL JOINTS AND MASONRY CONTROL JOINTS AT WALLS OVER 30'-0 IN LENGTH. LOCATE ABOVE EDGE OF OPENING WHEN POSSIBLE. M. AT FIRE RATED WALLS WHERE OPENINGS ARE GREATER THAN 16 SQUARE INCHES OR WHERE TOTAL AREA OF OPENINGS EXCEEDS 100 SQUARE INCHES IN 100 SQUARE FEET, WRAP 5/8 TYPE 'X' GYPSUM BOARD BEHIND OPENINGS PER U.L. DESIGN #U510. N. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT TRANSFER OF VERTICAL LOADS INTO PARTITION WHILE PROVIDING LATERAL SUPPORT REQUIRED VIA USE OF DOUBLE TRACK TYPE (SECONDARY TRACK SET INSIDE DEEP-LEG TRACK) OR SLOTTED TRACK TYPE, EACH ALLOWING VERTICAL MOVEMENT OF THE STRUCTURE, PREVENTING ROTATION OF STUDS BUT MAINTAINING STRUCTURAL PERFORMANCE OF PARTITION. O. LINE OF STRUCTURE INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY. P. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE RESISTANT FILL MATERIAL IN CONJUNCTION WITH AN APPROPRIATE RATED FIRESTOPPING SYTEM. Q. NON-RATED PARTITIONS SHALL USE ACOUSTICAL SEALANT. R. PROVIDE SHEET METAL OR FIRE RETARDANT WOOD BLOCKING IN WALL CAVITIES FOR ITEMS THAT ARE REQUIRED TO BE SECURED TO THE WALLS. REFERENCE MECHANICAL, PLUMBING, ELECTRICAL AND TECHNOLOGY DRAWINGS. COORDINATE WITH FURNITURE SUPPLIER WHERE APPROPRIATE. S. TAPE AND SPACKLE ALL PENETRATIONS IN GYPSUM BOARD PARTITIONS, INCLUDING, BUT NOT LIMITED TO WATER LINES, DRAINS, CONDUIT, THERMOSTATS, ETC. INSTALL FIRE RETARDANT SEALANT AT PENETRATIONS IN RATED PARTITIONS AS REQUIRED. T. ALL CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT UNITS LAID IN RUNNING BOND UNLESS NOTED OTHERWISE. U. ALL CMU WALLS SHALL EXTEND TO 4" MINIMUM ABOVE HIGHEST ADJACENT CEILING U.N.O. V. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION (S), EXTEND ATTENUATION TO FULL HEIGHT OF PARTITION U.N.O. FLOOR TRACK TO BE SET IN A CONTINUOUS BED OF SEALANT. W. IN AREAS DESIGNATED TO HAVE A RATED CEILING, BUILD WALLS THAT ARE NOT INDICATED TO GO TO DECK TO UNDERSIDE OF RATED CEILING. X. ALTHOUGH WALL STUD SIZE / SPACING ARE LISTED, CONTRACTOR WILL VERIFY AND PROVIDE APPROPRIATE SIZE / GAGE / SPACING OF STUDS REQUIRED FOR CONDITIONS INDICATED AND NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO FABRICATION / INSTALLATION. RATING PRIORITY 3 HOUR ASSEMBLY 1 2 HOUR ASSEMBLY 2 1 HOUR ASSEMBLY 3 SMOKE RATED ASSEMBLY 4 NON RATED ASSEMBLY 5 (LOWER NUMBER, HIGHER PRIORITY) HIGHER PRIORITY PARTITION GYPSUM BOARD CONTINUES THROUGH STUD CAVITY OF LOWER WALL LOWER PRIORITY PARTITION HIGHER PRIORITY CEILING/ROOF ASSEMBLY LOWER PRIORITY PARTITIONGYPSUM BOARD CONTINUES PAST TOP OF LOWER WALL G2 G3 G6 G1 G1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED G METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL TRACK SEALANT AND BACKER ROD; ONE SIDE, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL TRACK LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND G2S G3S G6S G8 NON- RATED NA 8 -5/8"8" G8S SEALANT AND BACKER ROD; ONE SIDE, CONT. M4 M6 M8 WALL PARTITION TYPE PLAN VIEW SECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH M PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW CMU SEALANT AND BACKER ROD; BOTH SIDES, CONT. LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING CMU WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA 5 -5/8" 3 -5/8" STC: NO SOUND WITH SOUND M4S M6S M8S M12 NON- RATED NA M12S SECTION VIEW7 -5/8" 11 -5/8" 5 -5/8" 3 -5/8" 7 -5/8" 11 -5/8" ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/2/2021 1:55:37 PMA000 WALL TYPES 2021.00173 05/20/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 INTERIOR PARTITION LEGEND GENERAL PARTITION NOTES RATED WALL PRIORITY REVISION SCHEDULE NO. DESCRIPTION DATE 2 ADDENDUM 2 07/02/2021 2 09/16/21