HomeMy WebLinkAbout08 SectionsDate: 08-16-2021 Plan number #201104 Designed For:Martin and Leslie Wessler NEW GENERATIONS HOMES, LLC.17406 Tiller Court Suite 800, Westfield, IN 46074 office@nghomesllc.com nghomesllc.com 317.896.5501
12" INSUL.
BATTS R-38
10" CONC. WALL w/ VERT.
#5 REBARS 14" o.c. &
#5 HORZ. REBARS 12"o.c.
FLUSH 2-PLYx91
4 LVL HDR. w/
METAL JST. HANGERS
16" I JST @ 16" O.C.
MASTER BEDROOM MASTER WALK-IN CLOSET
1 FRAMING SECTION2x8 RAFTE
RS 16" O.C.
2x6 STUDS
16" O.C. w/
12" DRYWALL
FULL THICK
CELLULOSE R-19
BLOWN IN INSUL.9'-912" 1'-434" 10'-118" 2x8 JOIST 16" O.C.
12
PITCH12
4 MIL POLYETHYLENE
VAPOR BARRIER
4 MIL POLYETHYLENE
VAPOR BARRIER
4" CONC. SLAB
W/ 6x6 #10 WWF
4" (MIN.)
GRAVEL FILL 4" DIA. PERF
PIPE w/SOCK
WATERPROOFING AS
SPECIFIED BY GENERAL
CONTRACTOR
GRAVEL FILL
WRAP WASH GRAVEL BACKFILL
w/ LANDSCAPE FELT MAT'L.
20"x10" THK. CONC. FTG
W/(2)#4 BARS CONT.
3
4" PLYWOOD
SUB FLOOR
AIR SPACE
BRICK VENEER
30# ASPHALT SAT. FELT
OR EQUAL
1/2" O.S.B. SHEATHING
INSUL.
BATTS 1'-91316" 9'-178"13'-1038"1'-71316" 9'-378"1'-71316" 14'-038"2
x
8
R
A
F
T
E
R
S
1
6
"
O
.
C
.
1'-6"3 12" 8'-612" 8'-4"5 12"13'-1" 13'-3" 312" 1'-6"
SEAT
CUT
SEAT
CUT
SEAT
CUT
ASPHALT SHINGLES
5/8" DECKING
13 4" X 117 8"
RIDGE BEAM
TOP OF
RIDGE BEAM
TOP OF
RIDGE BEAM 12
PITCH12 10'-0"POURED CONCRETE WALL HEIGHT10'-3"BOT. OF
LOOKOUT
INSUL.
BATTS
FITNESS ROOM GUEST BEDROOMCLOSET
30# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK
AREAS USE ICE & WATER SHIELD MEMBRANE
* Seal all joints between dissimilar materials.
* Metal flashing installed to all applicable areas
* All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall
flashing, etc.) shall be lapped to shed water to the outside of the building envelope
* Ridge vents as per contractor/manufacturer specifications
* 30# Asphalt sat. felt
* 5 8" Decking
* All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per
manufacturer specifications.
* Gutter and downspout locations and install specifications.
* Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to
resist wind and seismic forces.
* Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications.
* Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications.
* Flashing installed to wall/roof connections.
* Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above).
* Door flashing below the threshold.
* Flashing and water proofing top of chimney structure before installing chimney cap.
* Chimney exterior and interior metal flashing
* Baffle stop insulation installed properly, with correct R-factor.
* Low slope roofing material installed as per manufacturer specifications.
* Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications.
* Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor.
* Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials.
GENERAL NOTES, AS PER CONTRACTOR
10" CONC. WALL w/ VERT.
#5 REBARS 14" o.c. &
#5 HORZ. REBARS 12"o.c.
16" I JST @ 16" O.C.
16" I JST @ 16" O.C.9'-912" 1'-434" 10'-118" 1'-434" 9'-118"STUDYLIVING ROOM
GRILL/BAR
2 FRAMING SECTION
2x8 RAFTERS 16"
O
.
C
.
12
PITCH21
2
2x8 JOIST 16" O.C.
1'-6"61516" 13'-10916"
6" 9'-1158"112" 6'-31116"1'-6"312"
SEAT
CUT
SEAT
CUT
12
PITCH12
15'-3"
GALLERY
MEDIA/GAME ROOMBEDROOM #2 LANDINGWALK-IN CLOSET
3
4" PLYWOOD
SUB FLOOR
3
4" PLYWOOD
SUB FLOOR
2x10'S
2x10'S
W24x55#
STL. BEAM
W16x50# STL. BEAM
12
PITCH 12
OVERHANG
4 MIL POLYETHYLENE
VAPOR BARRIER
4" CONC. SLAB
W/ 6x6 #10 WWF
4" (MIN.)
GRAVEL FILL 10'-0"POURED CONCRETE WALL HEIGHT4" DIA. PERF
PIPE w/SOCK
WATERPROOFING AS
SPECIFIED BY GENERAL
CONTRACTOR
GRAVEL FILL
WRAP WASH GRAVEL BACKFILL
w/ LANDSCAPE FELT MAT'L.
3-PLYx24" FLUSH
LVL HDR. W/ JST.
HANGERS
FLUSH 2-PLYx16 LVL HDR. w/
METAL JST. HANGERS
FLUSH 2-PLYx16 LVL HDR. w/
METAL JST. HANGERS
4'-414"3 4"3'-4"
4'-414"34"3'-4"
PLYWD.
HANGER
= 4 TREADS
@ 10" EACH
PLYWD.
HANGER
= 4 TREADS
@ 10" EACH
2'-11916"2'-101516"= 5 RISERS@ 7116 "= 5 RISERS@ 714"9'-71116"BOT. OF
LOOKOUT 16'-358"BOT. OF
LOOKOUT
5'-113 4"
INSUL.
BATTS
7'-0" 5'-0" 9'-578"NOTE: EXTERIOR WALL,
FOUNDATION FLASHING &
WATERPROOFING AS
PER CONTR.
24"x12" THK. CONC. FTG
W/(3)#4 BARS CONT.
ENTERTAINING
AREA
STORAGE ROOM
2
x
8
RA
F
T
E
R
S
1
6"
O.
C.
31
2" NAILER
7'-534"R1'-958"5'-5516" 3'-1116"34"3'-4" 4'-212"
PLYWD.
HANGER
= 4 TREADS
@ 10" EACH
= 5 RISERS@ 714"5'-31316"2'-11716"= 5 RISERS@ 7116 "5'-012"
GRAVEL FILL
= 9 RISERS @ 7116 "4'-114"
6"X3"X 14" STL.
CARRIAGE TUBE
(4 ) 2 x 1 2 CARRI
A G E S
(4 ) 2 x1 2 CARRI
A G E S1'-11916"EXTERIOR WALL, ROOF
WATERPROOFING &
FLASHING AS PER CONTR.
DIM. TOP
OF SUB. FL.
DIM. TOP
OF FOUNDATION
5/8" DECKING
ICE & WATER SHIELD MEMBRANE
METAL ROOF VERIFY w/ CONTR.5'-2116"TOP OF
RIDGE BEAM
10" CONC. WALL w/ VERT.
#5 REBARS 14" o.c. &
#5 HORZ. REBARS 12"o.c.
MEDIA/GAME ROOM BEDROOM #2 LANDING
W24x55#
STL. BEAM
w/JST.
HANGERS
2x8 RAFTERS 16" O.C
.9'-912" 1'-434" 10'-118" 1'-434" 9'-118" 3 FRAMING SECTION
16" I JST @ 16" O.C.
16" I JST @ 16" O.C.
3
4" PLYWOOD
SUB FLOOR
3
4" PLYWOOD
SUB FLOOR
12
PITCH 4 1
4
6'-51316"3'-318" 4'-91516"12
PITCH23
16
ENTRY FOYERLIVING ROOMOUTDOOR LIVING
2-PLYx16" FLUSH
LVL HDR. W/ JST.
HANGERS
3-PLYx24" FLUSH
LVL HDR. W/ JST.
HANGERS
1'-0" 4" 22'-5" 312" 4'-0716" 24'-2916" 312" 7'-4" 1'-0"
2-PLY 2x8" FLUSH
HDR. W/ JST.
HANGERS
2x8 JOIST 16" O.C.
SEAT
CUT
SEAT
CUT
SEAT
CUT
12" INSUL.
BATTS R-38
4 MIL POLYETHYLENE
VAPOR BARRIER
4" CONC. SLAB
W/ 6x6 #10 WWF
4" (MIN.)
GRAVEL FILL
TOP OF
RIDGE BEAM
2x6 STUDS
16" O.C. w/
1
2" DRYWALL
FULL THICK
CELLULOSE R-19
BLOWN IN INSUL.
134" X 24"
RIDGE BEAM
20"x10" THK. CONC. FTG
W/(2)#4 BARS CONT.
2x4 BRACING
32" O.C.9'-138"2-PLYx117
8LVL HDR.112" 3" SLOPESTEP4" CONC. SLAB
W/ 6x6 #10 WWF
STAMPED CONC.112" 112"STEPSLOPE2-PLYx91
4
LVL HDR.
W16x50# STL. BEAM
2x8 RAFT
E
R
S
1
6
"
O.C.
51
2" NAILER
INSUL.
BAFFLE
STOP
12
PITCH12
8'-0" 2'-0" NOTE: EXTERIOR WALL,
FOUNDATION FLASHING &
WATERPROOFING AS
PER CONTR.GRAVEL FILL
3'-0" 7'-0"GRAVEL FILL
4" CONC. SLAB
W/ 6x6 #10 WWF
STAMPED CONC.
2x6 JOIST 16" O.C.
6"
1'-4"
RAKE
1'-0"8'-1112"DIM. TOP
OF SUB. FL.9'-71116"BOT. OF
LOOKOUT
2'-0"
5/8" DECKING
ICE & WATER SHIELD MEMBRANE
METAL ROOF VERIFY w/ CONTR.
2" RIGID
INSULATION
4 CAR GARAGE10'-118" 1'-434" 9'-118"2x8
R
A
F
T
E
R
S
1
6
"
O
.
C
.
2x6 JOIST 16" O.C.
2x6 JOIST 16" O.C.(4) 2x12
CARRI
A
G
E
S
6 FRAMING SECTION
AIR SPACE
BRICK VENEER
30# ASPHALT SAT. FELT
OR EQUAL
1/2" O.S.B. SHEATHING
1'-6"4316" 12'-2516" 24'-012" 6'-7716"4 916"1'-6"
2-PLYx16" FLUSH
LVL HDR. W/ JST.
HANGERS
SEAT
CUT
SEAT
CUT
16" I JST @ 16" O.C.
16" I JST @ 16" O.C.
34" PLYWOOD
SUB FLOOR
1'-812" 12'-111316"TOP OF
RIDGE BEAM
12
PITCH12
12
PITCH 5 3
16
10" 13'-10516"4 CAR GARAGE
9'-0"11'-0"1'-0"ASPHALT SHINGLES
5/8" DECKING
6'-7" 12'-6"714" 3 4"
2x10 HDR.9'-734"PLYWD.
HANGER
= 15 TREADS
@ 10" EACH = 17 RISERS@ 61316" 11'-738" TOP OF GARAGE
FOUNDATION
CLOSET/
FUTURE
ELEVATOR
11'-81516"BOT. OF
LOOKOUT
ASPHALT SHINGLES
5/8" DECKING
30# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK
AREAS USE ICE & WATER SHIELD MEMBRANE30# ASPHALT SAT. FELT, EXCEPT IN HIGH RISK
AREAS USE ICE & WATER SHIELD MEMBRANE
8SCALE: 1/4"=1'-0"FRAMING SECTIONS SHEET NUMBERH.G. McCULLOUGH DESIGNERS, Inc. 2146 GLENVIEW DR. EVANSVILLE, IN 47720 Telephone 812-428-0174Email designers@hgmccullough.com www.hgmccullough.com
"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction
of this work, its technical aspects or creative content without the express written consent
of H. G. McCullough Designers, Inc. This work is fully protected by copyright under
U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." DESIGNED BY:Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction details09/17/21