HomeMy WebLinkAbout10 SectionsDate: 08-16-2021 Plan number #201104 Designed For:Martin and Leslie Wessler NEW GENERATIONS HOMES, LLC.17406 Tiller Court Suite 800, Westfield, IN 46074 office@nghomesllc.com nghomesllc.com 317.896.5501 * Seal all joints between dissimilar materials. * Metal flashing installed to all applicable areas * All building materials (including but not limited to metal flashing, vapor barriers, air/water resistant barriers, thru-wall flashing, etc.) shall be lapped to shed water to the outside of the building envelope * Ridge vents as per contractor/manufacturer specifications * 30# Asphalt sat. felt * 5 8" Decking * All edge of roofs at eaves, rakes, valleys, hips and breaks, covered in ice and water shield material or equal. As per manufacturer specifications. * Gutter and downspout locations and install specifications. * Simpson seismic ties or equal to provide a positive connection between truss/rafters and the wall of the structure to resist wind and seismic forces. * Exterior metal drip cap, wall waterproofing and flashing install in all applicable areas with manufacturer specifications. * Window/door waterproofing and flashing install in all applicable areas with manufacturer specifications. * Flashing installed to wall/roof connections. * Flashing installed at connections to two different masonry types. (ie. stone water-table with stone sill and brick above). * Door flashing below the threshold. * Flashing and water proofing top of chimney structure before installing chimney cap. * Chimney exterior and interior metal flashing * Baffle stop insulation installed properly, with correct R-factor. * Low slope roofing material installed as per manufacturer specifications. * Metal roofs to have ice and water shield material or equal, installed as per manufacturer specifications. * Steel angle above windows, doors, and overhead doors to carry masonry as sized and installed as per contractor. * Contractor shall determine appropriate ventilation of exterior eave and rake requirements as per roof assembly and finish materials. GENERAL NOTES, AS PER CONTRACTOR9'-912" 1'-434" 10'-118" 1'-434" 9'-118"16" I JST @ 16" O.C. 16" I JST @ 16" O.C. 8 FRAMING SECTION DINING ROOM DINING AREA PANTRY/BUTLER'S PANTRY KITCHEN6'-412"12 PITCH 2 12 PITCH12 2x8 RAFTE R S 16" O .C. 2x6 RAFTERS 16" O.C. 2x6 JOIST 16" O.C. SAFE ROOM MECHANICAL STORAGE ROOM MARTIN'S ROOMHALLWAY BEDROOM #4 BEDROOM #3 WALK-IN CLOSET LAUNDRY ROOM WALK-IN CLOSET 2-PLYx16" FLUSH LVL HDR. W/ JST. HANGERS 12" INSUL. BATTS R-38 34" PLYWOOD SUB FLOOR 3 4" PLYWOOD SUB FLOOR 4 MIL POLYETHYLENE VAPOR BARRIER 4" CONC. SLAB W/ 6x6 #10 WWF 4" (MIN.) GRAVEL FILL 10" CONC. WALL w/ VERT. #5 REBARS 14" o.c. & #5 HORZ. REBARS 12"o.c. 12 PITCH12 2x6 STUDS 16" O.C. w/ 12" DRYWALL FULL THICK CELLULOSE R-19 BLOWN IN INSUL. 6" 31 2" NAILER 4" DIA. PERF PIPE w/SOCK WATERPROOFING AS SPECIFIED BY GENERAL CONTRACTOR GRAVEL FILL WRAP WASH GRAVEL BACKFILL w/LANDSCAPE FELT MAT'L.412"1'-6"678" 13'-458" SEAT CUT 1'-6"4516" SEAT CUT W16x57# STL. BEAM INSUL. BATTS 2x8 JOIST 16" O.C.10'-21116"BOT. OF LOOKOUT 10'-0"POURED CONCRETE WALL HEIGHTNOTE: EXTERIOR WALL, FOUNDATION FLASHING & WATERPROOFING AS PER CONTR.1'-958"EXTERIOR WALL, ROOF WATERPROOFING & FLASHING AS PER CONTR. 5/8" DECKING ICE & WATER SHIELD MEMBRANE METAL ROOF VERIFY w/ CONTR. 9 FRAMING SECTION6'-31116" 9'-118"BEDROOM #3 12 PITCH 12 6'-31116" 12" INSUL. BATTS R-38 TRUSSES 24" o.c. T.C. L.L. 30 PSF T.C. D.L. 10 PSF B.C. D.L. 10 PSF B.C. L.L. 0 PSF TOTAL 50 PSF NOTE: TRUSS DESIGN BY MFG. 1'-012" 312" 8'-91516" 1'-012"312" 1'-412" 1'-412" 312" 312"9'-138" 1'-278" 11'-0"9 PITCH 127'-3116"9'-7716"2x8 RA FTER S 16" O.C. BEDROOM #2 7'-10916" 312" SEAT CUT SEAT CUT SEAT CUT TOP OF MAIN LEVEL SUB FL. 2-PLYx117 8 LVL HDR. 3-PLYx117 8LVL HDR.1'-258"1'-0" 412"1'-258"HEELHGT.11'-0"11'-0" 512"5'-3316"2X6'S NAILED ALONG 2X8 RAFTERS HEELHGT.34" PLYWOOD SUB FLOOR 3 4" PLYWOOD SUB FLOOR 11'-1012" 1'-358"9'-71116"BOT. OF RAFTER CUT BOT. OF LOOKOUT512"7'-6716"6'-81516" 5'-3316"BOT. OF RAFTER CUT 2X8 CEILING JST. 16" o.c. 2X4'S NAILER 2X6'S NAILED ALONG 2X8 RAFTERS 2X4'S NAILER7'-6"TOP OF SECOND LEVEL SUB FL.R6'-6"2'-0"8"9'-312"512"2'-1"4'-0" 15'-6" 1'-914"312"5'-9" SEAT CUT 13'-6516"6"1'-6"STONE CORBEL6'-4"12 PITCH 12 TOP OF RIDGE BEAM 8'-6"1'-2516"1'-614" 7'-0" TOP OF FOUNDATION 3'-0" 34"2'-4"STONE CHAMFER EDGE 11 FRAMING SECTION 2 X 6 R A F T E R S 1 6" o . c . 2X6 CL'G JST. 16" o.c. 10SCALE: 1/4"=1'-0"FRAMING SECTIONS SHEET NUMBERH.G. McCULLOUGH DESIGNERS, Inc. 2146 GLENVIEW DR. EVANSVILLE, IN 47720 Telephone 812-428-0174Email designers@hgmccullough.com www.hgmccullough.com "C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." DESIGNED BY:Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction details09/17/21