HomeMy WebLinkAboutA311 - INTERIOR WALL SECTIONSSECOND FLOOR
EL: +12'-0"
THIRD FLOOR
EL. 24'-0"
PLATE BEARING
EL. 46'-0"
FIRST FLOOR
EL. 0'-0"
FOURTH FLOOR
EL. 36'-0"INTERIOR WALLSECTIONSARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20022
NOVEMBER 11, 2020
# DESCRIPTION DATEMAGNOLIACONDOMINIUMSCARMEL, IN100% CONTRACT SET GC/CM
A311SCALE:
01 WALL SECTION
1 HOUR DEMISING
1/4" = 1'-0"F1 F1 WG5a F2 F2 WG5a F2 F2 WG5a F2 F2 WG5a R1 R12
A311
2
A311
2
A311
3
A311
WG5a F2PROVIDE FIRE BLOCKING
AT ALL FLOOR LINES
PROVIDE FIRE BLOCKING
AT ALL CEILING LINES
FLOOR SHEATHING TO BE
CONTINUOUS ACROSS
AIRSPACE AT DEMISING
WALLS AND ACT AS
DRAFSTOPPING
CONTINUE WOOD
SHEATHING INTO FLOOR
SPACE AND UP TO FLOOR
SHEATHING ABOVE TO
ACT AS DRAFTSTOPPINGF2 SCALE:
02 SECTION DETAIL
1 1/2" = 1'-0"
PROVIDE FIRE BLOCKING
AT ALL CEILING LINES
WOOD SHEATHING
UP TO ROOF SHEATHING
ABOVE TO ACT AS
DRAFTSTOPPINGR1R1
SCALE:
03 SECTION DETAIL
1 1/2" = 1'-0"
WG5a
WG5a
4"
4"
1 100% CONTRACT SET 11-11-2020
SET RESILIENT CHANNELS ON EA. SIDE OF
THE WALL WITH STUD LEG AS SHOWN AND
MAX. 1.75 INCHES AWAY FROM WALL STUD,
THEN CONTINUES INSTALLING THEM PER UL
ASSEMBLY REQUIREMENTS
2
2
REVISION 01 01-15-2021
09/22/21