HomeMy WebLinkAboutA400 - TYPICAL UNIT DETAILSEXTERIOR SIDE EXTERIOR WALL FINISH JOINT (TAPE AND COMPOUND) THE EXTERIOR WALL FINISH AND THE SHEATHING ARE THE ONLY SOLID WALL OR FLOOR ELEMENTS THAT BRIDGE THE SEPARATION BETWEEN DWELLING UNITS CONTINUOUS SEALANTCONTINUOUS SEALANT JOINT (TAPE AND COMPOUND) 24" MIN. SEAL DRYWALL TIGHT TO BASE AND FILL GAPS WITH TAPE AND MUD OR NON-HARDENING SEALANT NOTES: 1. LIGHT SWITCHES AND OUTLETS SHOULD BE OFFSET AT LEAST 24" AND BE LOCATED IN SEPARATE STUD CAVITIES. 2. SOUND ATTENUATION INSULATION SHOULD EXTEND BEHIND ELECTRICAL OUTLETS SEAL DRYWALL TIGHT TO BOX PENETRATION AND FILL GAPS WITH JOINT COMPOUND/MUD. USE JOINT REINFORCING TAPE AS NEEDED WATER CLOSET FILL THE GAP BETWEEN THE EDGES OF THE FLOOR PENETRATION AND THE WATER CLOSET FLANGE WITH AN APPROVED MEMBRANE PENETRATION FIRESTOP SYSTEM WATER CLOSETS TO BE RESILIENTLY MOUNTED WHEN SERVED BY DRAINS OR VENTS WHICH ARE INSTALLED WITHIN DEMISING ASSEMBLIES SECTION VIEW JOINT (TAPE AND COMPOUND) AT BOTH SIDES OF WALL SET RESILIENT CHANNELS ON EA. SIDE OF THE WALL WITH STUD LEG AS SHOWN AND MAX. 1.75 INCHES AWAY FROM WALL STUD, THEN CONTINUE INSTALLING THEM PER UL ASSEMBLY REQUIREMENTS UNIT SIDEUNIT SIDE NON- HARDENING SEALANT CONTINUOUS SEALANT CONTINUOUS SEALANT PROVIDE FIRE BLOCKING AT ALL CEILING LINES SEE 2/A311 FOR ADDITIONAL INFORMATION PROVIDE PERIMETER ISOLATION FOAM STRIP @ ALL UNIT WALL TO FLOOR INTERSECTIONS. CONTINUE TO FACE OF SILL PLATESECTION VIEW SHEATHING PER STRUCTURAL DWGS SOUND ISOLATION MAT CEMETITIOUS UNDERLAYMENT SCHEDULED FLOORING GAP UNDER BASE BOARD SCHEDULED BASE BOARD SHALL NOT CONTACT FLOORING. DO NOT APPLY SEALANT BETWEEN BASE AND FLOORING SCHEDULED WALL, REF. ENLARGED UNIT PLANS CONTINUOUS SEALANT TOP OF COUNTER 3'-0" A.F.F. REF. FLOOR PLANS FOR WALL TYPES WRAP BOX (5 SIDES) WITH 58" TYPE 'X' GWB, TAPE ALL JOINTS SEMI-RECESSED FIRE EXTINGUISHER CABINET 2 x WIDTH OF WALL FIRE BLOCKING, TYP. FLEXIBLE FLASHING (ON EXTERIOR SHEATHING) TOP STRAIGHT FLASHING OVER VERTICAL STRAIGHT FLASHING WALL PENETRATION. SEAL CONTINUOUS AROUND IT AND FINAL EXT. WALL FINISH VERT. STRAIGHT FLASHING OVER HRZ. BOTTOM STRAIGHT FLASHING REFER TO LIGHTING SCHEDULE FOR ACTUAL DESIGN CAULK ELECTRICAL BOXES TO DRYWALL NOTE: 1. LIMIT INSTALLATION OF RECESSED CANS TO FURRED DOWN LOCATIONS AT UNIT SEPARATIONS TO AVOID COMPROMISING FIRE AND SOUND RATINGS. SEAL BATHROOM DRAIN PENETRATION FIRE-RETARDENT SEALANT, ENTIRE PERIMETER OF COLLAR NON-COMBUSTABLE FLUE COLLAR (SHEET METAL) HVAC UNIT PROVIDE SEALANT (FIRE-RETARDANT AT RATED CONSTRUCTION) AT PERIMETER OF COLLAR BEHIND ALL REGISTER/RETURN AIR BOOTS, TYPICAL. HVAC DUCT GRILL COVER - SEE MECH DRAWINGS UNIT TYPICALDETAILSA400 SCALE: 01 AT INTERIOR WALLS TUB/SHOWER 1 1/2" = 1'-0" 58" TYPE 'X' GYPSUM WALL BOARD SHALL EXTEND TO FLOOR LEVEL. SCALE: 07 AT DEMISING ASSEMBLY ELECTRICAL PENETRATION 1 1/2" = 1'-0" SCALE: 08 AT DEMISING ASSEMBLY PLUMBING PENETRATION 1 1/2" = 1'-0" SCALE: 03 AT DEMISING FLOOR ASSEMBLY PLUMBING PENETRATION 1 1/2" = 1'-0" SCALE: 09 AND EXTERIOR WALL INTERSECTION UNIT DEMISING WALL 1 1/2" = 1'-0" SCALE: 10 ATTACHMENT TO CEILING AND FLOOR DEMISING WALL 1 1/2" = 1'-0" SCALE: 04 FLOOR TO WALL CONNECTION TYPICAL VINYL PLANK 3" = 1'-0" BATHTUB / SHOWER SURROUND SCALE: 02 SECTION DETAIL KITCHEN ISLAND 1 1/2" = 1'-0" SCHEDULED UNIT KITCHEN COUNTERTOP PAINT GRADE WOOD TRIM SCHEDULED UNIT BASE BOARD UNIT CASEWORK PER UNIT INTERIOR ELEVATIONS AND UNIT ENLARGED FLOOR PLANS SCALE: 05 DETAIL FIRE EXTINGUISHER 1 1/2" = 1'-0" WG1b 12"ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20022 NOVEMBER 11, 2020 # DESCRIPTION DATEMAGNOLIACONDOMINIUMSCARMEL, IN100% CONTRACT SET GC/CM 58" GYPSUM GREEN BOARD TO STOP AT TOP OF TUB OR SHOWER PAN. USE 12" CEMENT BACKERBOARD IN LIEU OF GYPSUM GREEN BOARD AT TILED SHOWERS. 1 100% CONTRACT SET 11-11-2020 SCALE: 06 PENETRATION DETAIL TYPICAL SEALANT @ 1 1/2" = 1'-0" SCALE: 11 BOX SEALING DETAIL LIGHT FIXTURE ELECTRICAL 1 1/2" = 1'-0" SCALE: 12 PENETRATION (TUB) BATHROOM DRAIN 1 1/2" = 1'-0" SCALE: 13 PENETRATION SEALING DETAIL HVAC RATED 1 1/2" = 1'-0" SCALE: 14 PENETRATION SEALING DETAIL HVAC RATED 1 1/2" = 1'-0" WG5a WG5a 2 2 2 2 WG5aWG5a 2 2 REVISION 01 01-15-2021 09/22/21