Loading...
HomeMy WebLinkAboutFull CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/3 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:August 9, 2021 Project number Release date 422815 08/09/21 Construction type Occupancy classification Scope of release V-A, SPK R-2, S-2, U Type of release Project name Street address City County ARCH ELEC MECH PLUM STR Standard Magnolia Condos TBD CARMEL HAMILTON To: Owner / Architect / Engineer Studio M Architecture & Planning Nicholas S Alexander AR11500031 2 West Main Street Carmel IN 46032 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 14B 4G0603AE1 14B1100HC 14B07037 14B07061A 14B0406341B 14B09072112 14B1008198 This project has been reviewed under the 2014 Indiana Building Code. Detailed plans and specifications of the fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and 675 IAC 13-1-25. (N.F.P.A. 13R) The current code for handicapped accessibility in use in the State of Indiana is Chapter 11 of the Indiana Building Code (675 IAC 13-2.6) and ICC standard A117.1, 2009 edition (675 IAC 13-2.6). Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording, "FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with Section 703.7, IBC (675 IAC 13-2.6). Each portion of a building separated by one or more complying fire walls shall be considered a separate building in accordance with Section 706.1, IBC (675 IAC 13-2.6). Door openings between a private garage and the dwelling unit shall be in accordance with Section 406.3.4.1, IBC (675 IAC 13-2.6). Smoke alarms shall be installed in Groups R-2, R-3, R-4, and I-1 occupancies in accordance with Section 907.2.11.2, IBC (675 IAC 13-2.6). Entrance doors in a means of egress in buildings with an occupancy in Groups A, B, E, I-2, M, R-1 or R-2, and entrance doors to tenant spaces in occupancies in Groups A, B, E, I-2, M, R-1 or R-2, are permitted to be equipped with an approved entrance and egress access control system, listed in accordance with UL 294, which shall be installed and operate in accordance with items 1 through 6, in accordance with Section 1008.1.9.8, IBC (675 IAC 13-2.6). Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3178101502, nalexander@studiomarchitecture.net ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/3 14B11076212A 14B4205 14B0708A 14B07113A 14B11076212 14B07165A 14B07165B A2 14B1009 14B10136 14B10291A 14M0920 14M0306 14B10142 4G0618AK AREL Type B units shall be provided in R-2 occupancies in accordance with Section 1003, ICC A117.1, 2009 edition and Section 1107.6.2.1.2, Chapter 11, IBC (675 IAC 13-2.6). Group I-1, R-1 and R-2 occupancies shall be provided with fire alarm systems and smoke alarms in accordance with Section 420.5, IBC (675 IAC 13-2.6). Walls separating dwelling units in the same building, walls separating sleeping units in the same building and walls separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as fire partitions in accordance with Section 708 and Section 420.2, IBC (675 IAC 13-2.6). Floor assemblies separating dwelling units in the same buildings, floor assemblies separating sleeping units in the same building and floor assemblies separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as horizontal assemblies in accordance with Section 711 and Section 420.2, horizontal separation, IBC (675 IAC 13-2.6). All ground floor dwelling units shall be in accordance with Section 1004, ICC A117.1, 2009 edition and Section 1107.6.2.1.2, Chapter 11, IBC (675 IAC 13-2.6). Openings in fire walls shall be protected assemblies in accordance with Section 716.5 and Table 716.5, IBC (675 IAC 13-2.6). Openings in fire barriers shall be protected assemblies in accordance with Section 716.5 and Table 716.5, IBC (675 IAC 13-2.6). An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm Every stairway serving occupied portion of a building shall comform to the requirements of Section 1009, IBC (675 IAC 13-2.6). Guards shall be provided where appliances, equipment, fans, roof hatch openings or other components that require service are located within 10 feet of a roof edge in accordance with Section 1013.6, IBC (675 IAC 13-2.6). Basements and sleeping rooms below the fourth story above grade plane shall have at least one exterior emergency escape and rescue opening in accordance with Section 1029.1, IBC (675 IAC 13-2.6). Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC (675 IAC 18-1.6). Access and service space for equipment and appliances shall be in accordance with Section 306, IMC (675 IAC 18-1.6). Egress through intervening spaces shall comply with provisions of Section 1014.2, IBC (675 IAC 13- 2.6). "Alternates" to plans are not part of this release and will only be considered as part of this project if submitted as addenda in accordance with 675 IAC 12-6-l8. Such design changes shall not include increases in project height and / or area. Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission). Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222. If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7 and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods: U.S. MAIL OR PERSONAL SERVICE ONLINE ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 3/3 Fire Prevention and Building Safety Commission By completing the form at c/o Legal Counsel https://www.in.gov/dhs/4148.htm 302 W. Washington Street, Rm. E208 Indianapolis, IN 46204 For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link https://www.in.gov/dhs/appeals.htm. Code review official Address (name,title of local official,street,city,state and ZIP code LARRY DAVIS JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissioner ldavis2@dhs.in.gov