HomeMy WebLinkAboutP500 - PLUMBING DETAILS - DWVFOR INSULATED PIPING) TO STRUCTURE 1/2" HANGER ROD WHERE REQUIRED FIBERGLAS ONLY INSULATED PIPE METAL SHIELD FOR 20 GAUGE SHEET BARRIER (TYPICAL CONTINUOUS VAPOR NUT (TYPICAL) HANGER PIPING STRAP THRU BOLT NOTES: REFER TO RELATED SECTIONS OF THE SPECIFICATIONS FOR INFORMATION REGARDING FLASHING MEMBRANE AND FIRESTOP SEALANT FINISH FLOOR LC PROVIDE NEW CONCRETE TO MATCH EXISTING FLOOR FLASHING MEMBRANE REMOVE EXISTING CONCRETE TO RECIEVE FLASHING CLAMP FIRESTOP SEALANT CORE HOLE TO RECIEVE DRAIN BODY FLOOR DRAIN BODY EXISTING SLAB FLOOR DRAIN GRATE TRAP SEAL TO GRADE DETAIL AT END OF LINECLEANOUT OCCURS 1/8 BEND IF WASTE LINE LENGTH TO SUIT WASTE LINE 1/8 BEND FINISHED GRADE HEAD WITH COUNTER SUNK BRASS CLEANOUT PLUGFLOOR LINE SAME AS CLEANOUT BALANCE OF PIPE 1/8 BEND AREASFOR CARPETEDCARPET MARKER OF FLOORTO BE FLUSH WITH TOP COVER. TOP OF COVERCLEANOUT AND ACCESS CLEANOUT TO GRADEFLOOR CLEANOUT NOTE: LOCATE PIPING 1 1 /2" MIN. CLEARANCE OF GYPSUM BOARD CAULK AIRTIGHT WITH ACOUSTICAL OR FIRE-RATED SEALANT FLOOR CONSTRUCTION SAFING BATT INSULATION BACKER ROD PIPE RISER CLAMP STEEL SHIM (OPTIONAL) 3/4" NEOPRENE PAD 0.2500 NOTE: FIRE SEALANTS AND PIPE PENETRATION SHALL HAVE AN F-RATING AND NO LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE WALL PENETRATED. SANITARY, DRAINAGE OR WATER PIPE NON-SECURE SPACESECURE SPACE PVC PIPE SLEEVE RATED CAULK. 1/4" BEAD OF FIRE DISHWASHER LOOPED HIGH AND SECURELY FASTENED TO COUNTER OR WALL 2" FOOD-WASTE GRINDER 1/2" TO FOOD WASTE GRINDER INLET SUMP RECEIVER COLUMN CLAMP TO WALL OR COLUMN OFFSET (IF REQUIRED BY JOB CONDITION) ROOF DRAIN INSULATION UNDERDECK CLAMP PLUGGED SLEEVE NOTE: 1 . PROVIDE RISER CLAMP AT ALL OTHER FLOOR PENETRATIONS. 2. HOLD HORIZONTAL PIPING AT DESIGN SLOPE (1 /4" PER FOOT FOR 2" AND 3" PIPE, 1 /8" PER FOOT FOR LARGER PIPE) TO ALLOW MAXIMUM UTILIZATION OF AVAILABLE PIPE SPACE IN BUILDING. TRAPEZE HANGER (3/4" PIPE FOR PIPING UP TO 5", 1 " PIPE FOR LARGER PIPING.) ALL THREAD ROD (3/8" FOR PIPING UP TO 6", 1 /2" FOR LARGER PIPING) CONCRETE INSERT HOLD BELL OF HUB TIGHT TO BOTTOM OF FLOOR CONSTRUCTION EXTEND SLEEVE 2" ABOVE FINISHED SLAB EXTEND SLEEVE 2" ABOVE LOCATIONS WHERE TOPPING SLAB EXISTS PIPE SLEEVE FLOOR SLAB TOPPING SLAB (REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS) FOR PENETRATIONS IN FIRE RATED FLOORS, FILL VOID OR CAVITY WITH MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES INC. FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM OR U.L. CLASSIFIED THROUGH-PENETRATION FIRESTOP DEVICE NO SCALE A A REFER TO SPECIFICATIONS FOR ADDITIONAL SLEEVE REQUIREMENTS 1 8 GAUGE CONTINUOUS SHEET METAL ENCLOSURE FOR PENETRATIONS WITH FIRE-STOP MATERIAL. ENCLOSURE SHALL NOT BE ATTACHED TO PIPE OR INSULATION. SECTION A-A NO SCALE TOPPING SLAB (REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS) FOR PENETRATIONS IN FIRE-RATED FLOORS, FILL VOID, OR CAVITY WITH MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES INC. FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM OR U.L. CLASSIFIED THROUGH-PENETRATION FIRESTOP DEVICE 1 /4" TO 3/8" GAP BETWEEN PIPE AND CORE PIPE AND/OR CONDUIT 1" TYP OUTSIDE SURFACE OF PIPE (OR INSULATION) 1 /4" TO 3/8" GAP BETWEEN EDGE OF ENCLOSURE AND PIPE SLEEVE UNDERSIDE PLAN VIEW OR 3 FT. ABOVE STRUCTURE. 1 0 FT. (MIN.) FROM ANY WALL VENT STACK OUTLET TO BE NOTE: ROOFING CONSTRUCTIONROOF FLASHING SLEEVE VENT STACK VENT STACK EXTENSIONHOLE IN WALL FINISH BY OTHERS WOOD OR STEEL FRAMING STUD SCREW MOUNTING BRACKET TO STUD WASH MACHINE SERVICE CONNECTION BOX OVERFLOW TRAY 2" WASTE OUTLET 1/2" CW SUPPLY TOP OF BOX TOP OF MACHINE 3-1/2" XX" TO FL. SHOCK ABSORBER TYPICAL SERVICE STOP RI G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.RMOO RET R NNDIA A STATE OF DEMOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729 ARCHITECTCLIENT PROJECT DRAWING TITLE SHEET PROJECT INFO REVISIONS20022 # DESCRIPTION DATEMAGNOLIACONDOMINIUMS126TH & RANGELINERD CARMEL, IN100% Contract Set GC/CM SEAL 10/07/2020 P500 PLUMBING DETAILS -DWV09/22/21