HomeMy WebLinkAboutP-601 - PLUMBING DETAILS40" MIN.36" MIN. DOOR MIN. 30" WATER HEATER PAN WATER HEATER FAN COIL UNIT PLENUM CLEARANCE RACK REFRIGERANT LINE SETS ON SIDE WALL OF MECH ROOM RETURN GRILLE, SEE PLANS CONDENSATE DRAIN; ROUTE TO HUB DRAIN MAIN SHUT-OFF WATER HEATER PAN SLEEVE FLEX CONN. DUCTFIRE DAMPER W/ACCESS PANEL FAN COIL UNIT WATER HEATER HW CW VALVE (TYP.) SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN, REFER TO HVAC AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER PLENUM BOX OR ELBOW, R/D=1.5 MIN. 20"9'-0" REFER TO PLANSSEE HVACPLANSSEE HVAC PLANS12"MIN.NOM.36"FIRE PARTITION BY CONTRACTOR; WITH FOAM SEAL.4"NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON HVAC DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUCTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOINTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING, FLOOR AND THROUGH FCU SUPPORT. NOM. 30" T&P VALVE, ROUTE DRAIN LINE TO HUB DRAIN 4" HUB DRAIN 2" WASTE TRAP SHALL NOT BE INSTALLED BELOW FLOOR BUT SHALL BE ROUGHED IN NOT LESS THAN 6" AND NOT MORE THAN 18" ABOVE FLOOR NO STANDPIPE RECEPTOR SHALL EXTEND MORE THAN 30" NOR LESS THEN 18" ABOVE ITS TRAP 1 1/2" VENT 1/2"CW 1/2"HW SHUTOFF VALVE WITH THREADED HOSE CONNECTION 2" WASTE P-TRAP WITH UNION CONNECTIONS FLOOR LINE CLOTHES WASHER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO GUY GRAY SERIES RECESSED WALL BOXES SINK SHUT-OFF VALVE REDUCER GARBAGE DISPOSAL 5/8" DRAIN HOSE 1 1/2" VENT 2" SAN DISHWASHER 1/2" HW CW SUPPLY HW SUPPLY CODE APPROVED AIR ADMITTANCE VALVE (AAV) COUNTERTOP INSTALL AS HIGH AS POSSIBLE UNDER THE COUNTERTOP 4" MIN. SLOPE RISER PIPE SAME AS SEWER 18"x18"x8" THICK CONCRETE PAD ROUND FLANGED HOUSING W/ HEAVY DUTY CAST IRON COVER LIKE J.R. SMITH 4251 CLEANOUT PLUGFINISH GRADE 2-WAY FITTING SYSTEM RISER CAST IRON FLANGE AND SPIGOT PIECE CAST IRON BELL AND SPIGOT PIPE THRUST BLOCKING RODS FIRE SERVICE MAIN RESTRAINT BUILDING SLAB AT REFRIGERATORS = 12" AFF. AT ICE MACHINES = 12" AFF. AT COUNTERS = 1" ABOVE COUNTER BACK SPLASH, FOR COFFEE MAKER SUPPLY VARIESREFRIGERATOR ICE MAKER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO OATEY SERIES RECESSED WALL BOXES ANGLE STOP VALVE WITH THREADED CONNECTION FOR ICE MAKER TUBING 1/2"CW FLOOR LINE SLOPE RISER PIPE SAME AS SEWER FINISH FLOOR CLEANOUT BOX WITH RECESSED SOLID COVER BRONZE PLUG MAXIMUM MOUNTINGHEIGHT OF 5'-0"ABOVE FLOORWALL SLEEVE (TYPICAL) 4"CW INCOMING SERVICE WITH JOINT HARNESS REACTION ANCHORS PROVIDE REMOTE WATER METER READ OUTS, SEE FLOOR PLANS FOR LOCATION REDUCED PRESSURE BACKFLOW PREVENTER 4"CW TO BUILDING SERVICE 1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'S REQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED. NOTE: NEEDLE VALVE PRESSURE GAUGE COUPLING ADAPTOR (TYP) METER METER GATE VALVE (TYP) SEE SPECIFICATIONS FOR PIPE SUPPORT REQUIREMENTS TYPICAL DRAIN FUNNEL WITH AIR GAP, TERMINATE DRAIN LINE OVER NEAREST FLOOR DRAIN BFP-1 BFP-2 4"CW 4"CW STRAINER (TYP) THREADED CLEANOUT PLUG TEST TEE ACCESS COVER AND FRAME FINISHED WALL SURFACE PIPE DOUBLE SUPPORT NUT LOCKING NUT HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUTCLEVIS HANGER 14 GAUGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG PIPE INSULATION INSULATION PREFORMED PIPE SUPPORT INSERT, SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS PURPOSE ROOF DECK STEEL ANGLE FRAME SUPPORT 24"x24" SUMP RECEIVER INSULATION 1 1/2"x1 1/2" UNI-STRUT FRAME UNDER DECK CLAMP CAST IRON DOME WITH TWIST LOCK RIGID INSULATION MEMBRANE ROOFING ADJUSTABLE EXTENSION ROOF DECK STEEL ANGLE FRAME SUPPORT 24"x24" SUMP RECEIVER INSULATION 1 1/2"x1 1/2" UNI-STRUT FRAME UNDER DECK CLAMP CAST IRON DOME WITH TWIST LOCK RIGID INSULATION MEMBRANE ROOFINGADJUSTABLE EXTENSION 2" HIGH WATER DAM INSULATION BLOCKING UNI-STRUT TRAPEZE SUPPORT STRUT PIPE CLAMP PIPE INSULATION MATERIAL (REFER TO SPECIFICATIONS) SYSTEM PIPE (REFER TO DRAWINGS FOR TYPE OF SYSTEM AND PIPE SIZE) OR CUSHION STRIP NEOPRENE ISOLATOR THREADED STEEL HANGER ROD STEEL ROD COUPLING 48" A.F.F. IN MECH CLOSETSRECESSED WALL VALVE BOX WITH FACE PLATE; EQUAL TO ACUDOR ARVB RECESSED WALL VALVE BOXES BALL VALVE FLOOR LINE 3/4"CW, SEE ENLARGED FLOOR PLANS 3/4"CW, SEE ENLARGED FLOOR PLANS12"PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR BASED ON CARLISLE U-8-A. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOF DECK - SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION OPENING IN DECK BY PLUMBING CONTRACTOR SEE DRAWINGS FOR SIZE INCREASER AS REQUIRED PIPE SIZE PER DRAWINGS CARRIER PIPE WATER STOP AND ANCHOR COLLAR WALL WALL SLEEVE MECHANICAL INTERLOCKING RUBBER LINKS TYPE WALL PENETRATION SEAL CONTROL PANEL AND VFD'S HYDROPNEUMATIC TANK TYPICAL PUMP TYPICAL FLEXIBLE CONNECTOR FLOOR CONCRETE HOUSEKEEPING PAD NORMALLY CLOSED FULL LINE SIZE BY-PASS PRESSURE REGULATING VALVE AND CHECK VALVE TYPICAL SHUT OFF VALVE TYPICAL CHECK VALVE CW TO BUILDING SERVICE CW FROM BFP'S, AND WATER METERS NOTE: REFER TO SCHEDULE AND SPECIFICATIONS FOR ACTUAL QUANTITY OF PUMPS. 3/4"HW 3/4"CW BALL VALVE CHECK VALVE THERMAL EXPANSION TANK ET-1 SUPPORT FROM STRUCTURE VACUUM RELIEF VALVE ASME APPROVED TEMP. & PRESSURE RELIEF VALVE. TERMINATE RELIEF DRAIN LINE OVER MOP BASIN OR NEAREST FLOOR DRAIN WITH MINIMUM 4" AIR GAP PAN ASSEMBLY DRAIN, TERMINATE OVER MOP BASIN OR NEAREST FLOOR DRAIN WITH MINIMUM 4" AIR GAP ELECTRIC WATER HEATER DWH-3 TANK DRAIN SUPPORT PLATFORM ASSEMBLY WITH DRAIN PAN AND SUPPORT BRACKETS. EQUAL TO HOLDRITE #50-SWHP-M. INSTALL PER MANUFACTURER'S REQUIREMENTS ALL-THREAD SUPPORT RODS UNION (TYPICAL) THERMOMETER CW HW FINISH HEIGHT OF ROOF HYDRANT TO BE MIN OF 3'-0" A.F.R. ROOF MEMBRANE 1/8" N.P.T. DRAIN HOLE CONNECT TO 1/2" DRAIN PIPE AND TERMINATE OVER FLOOR DRAIN 3/4" COLD WATER PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOF DECK -SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION OPENING IN DECK BY PLUMBING CONTRACTOR HEAD CASTING DUAL CHECK VALVE 3/4" HOSE CONNECTION HANDLE WATER TIGHT SEAL UNDER DECK FLANGE MOUNTING BOLTS (4)MIN OF 10"11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFES S IONA L E N G INEERDATE SIGNED 08/31/21 R E G I S T ER E D I ND I A N A 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS GRJK800 West Monon Green Blvd.P-601 PLUMBING DETAILS 08/31/202108/31/2021 NOT TO SCALE APT. WATER HEATER & FAN COIL UNIT DETAILA NOT TO SCALE CLOTHES WASHER BOX PIPING DETAILB NOT TO SCALE DISHWASHER/DISPOSAL DETAILC NOT TO SCALE EXTERIOR CLEANOUT DETAILD NOT TO SCALE FIRE SERVICE CONNECTIONE NOT TO SCALE RECESSED WATER VALVE BOX DETAILF NOT TO SCALE INTERIOR CLEANOUT DETAILG NOT TO SCALE MULTIPLE WATER METER PIPING DETAILH NOT TO SCALE NO HUB CLEANOUT W/ ACCESS DOOR DETAILI NOT TO SCALE PIPE HANGER DETAILJ NOT TO SCALE ROOF DRAIN DETAIL (W/ EXTENSION)K NOT TO SCALE ROOF OVERFLOW DRAIN DETAIL (W/ EXTENSION)L NOT TO SCALE TRAPEZE DETAILM NOT TO SCALE UNIT RECESSED WALL VALVE BOX DETAILN NOT TO SCALE VENT THRU ROOF DETAILO NOT TO SCALE WALL/FLOOR SLEEVE DETAILP NOT TO SCALE WATER BOOSTER PUMP PIPING DETAILQ NOT TO SCALE SUSPENDED WATER HEATER PIPING DETAILR NOT TO SCALE ROOF HYDRANT DETAILS