HomeMy WebLinkAboutA004 ADA STANDARDS3' - 0" 6"2' - 10"REAR GRAB BAR 3' - 6" 1' - 0"2' - 10"SIDE GRAB BAR1 2A VERTICAL GRAB BAR 2B GRAB BAR 2B GRAB BAR 2A3' - 4" 1' - 6"3' - 3" TYP. & HC ROLL TOILET PAPER HOLDER (RTPH) 3 RTPH 7"1' - 7"2' - 6"TYP. & HC SANITARY NAPKIN DISPOSAL (SND) 4 2' - 6"SND HC TOILET SEAT COVER DISPENSER (TSCD) 5 4' - 0"TSCD MAX. PROTRUSION 4" TYP. & HC SOAP DISPENSER (SD) 6 3' - 6"SD PAPER TOWEL DISPENSER (PTD) 7 4' - 0"PTD DRINKING FOUNTAIN (DF) 8 3' - 0"CLEAR 1' - 3"HC SPOUT HEIGHT NOTE: • ALL TOILET PAPER DISPENSERS INSTALLED @ 7" MIN. TO 9" MAX. IN FRONT OF WATER CLOSET. • BOTTOM OF REFLECTIVE SURFACE INSTALLED @ 40" MAX. • SEAL AROUND ALL RECESSED RESTROOM EQUIPMENT. • PROVIDE 16 GA. BACKING @ ALL ACCESSORIES & LAV. TOPS @ GRAB BARS PROVIDE 16 GA. BACKING SECURED TO @ LEAST 3 STUDS. • CAULK AROUND JOINT @ BOTTOM OF WATER CLOSET & FLOOR. HC TOILET 9 1' - 6"1' - 5"2' - 4"TYP. URINAL 10A 2' - 1"HC URINAL 10B 1' - 5"TYP. & HC PRIVACY SCREEN 10C 1' - 2" 3' - 6"1' - 6" PLAN TYP. STALL PARTITION 11 2' - 0"5' - 0" CLEARINT. ELEV. A INT. ELEV. B EQ EQ VARIES B A 6' - 10"5' - 0" 1' - 2" 4' - 7"4 3 3' - 0"5' - 0"PLAN HC STALL PARTITION 1' - 6" B A 5' - 0" CLEAR5' - 0" CLEAR 4" 2' - 8" 12 3' - 6" MIN.4 3 2 5' - 0" CLEAR 6' - 10"1' - 2" 4' - 7"INT. ELEV. A INT. ELEV. B 4' - 0" COAT HOOK PLAN AMBULATORY STALL PARTITION 13 EQ. 2' - 8" EQ. 5' - 0" CLEARB A 3' - 6" MIN. 3' - 0" CLEAR INT. ELEV. A INT. ELEV. B 1' - 2" 4' - 7"6' - 10"5' - 0" COAT HOOK 4' - 0" 3' - 0" COAT HOOK TYP. & HC LAVATORY13 2' - 2"2' - 10"3' - 4"BOTTOM OF REFLECTIVE SURFACE OF MIRROR2' - 0"3 1/2" 4"PLAN BATHTUBS W/ PERMANENT SEATS 14 INT. ELEV. PLAN BATHTUBS WITHOUT PERMANENT SEATS 15 INT. ELEV. A INT. ELEV. B LOCATION OF BATHTUB CONTROLS PLAN TRANSFER-TYPE SHOWER 16 INT. ELEV. MAX. 1' - 0" MAX. 1' - 3"2' - 0" MIN.4" MAX.8"-10"33" - 36" 3" - 6"18" MIN.2' - 0" MIN.4" MAX.MAX. 1' - 0" MIN. 2' - 0" MAX. 2' - 0"MIN.1' - 0"8"-10"33" - 36" 3" - 6"18" MIN.SEAT WALL CONTROL WALL 1' - 6"4" MAX.15" MAX.38" MIN.48" MAX.FLUSH CONTROL MAX. PROTRUSION 4" T.O. DISPENSER CONTROL 4 3 2 WALL MOUNTED FIXTURES FLOOR MOUNTED FIXTURES TRANSFER SIDE FLUSH VALVE ON OPEN SIDE 33" - 36"17" - 19"24" MIN. 12" MIN. 36" MIN. 16"-18"33" - 36"MAX. 12" MIN. 42" 54" MIN. 18" MIN.39" - 41" 39"-41"17"-19" NOTE: CONTROLS & OPERATING MECHANISMS SHALL BE OPERABLE W/ ONE HAND & SHALL NOT REQ. TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF (22.2 N) FAUCETS LEVER-OPERATED, PUSH-TYPE & ELECTRONICALLY SHALL COMPLY WITH 4.27.4 CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF-CLOSING VALVES ARE USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. TRANSFER SIDE 33" - 36"17"-19"24" MIN. 12" MIN. 36" MIN. 16"-18"33" - 36"MAX. 12" MIN. 42" 54" MIN.18" MIN.39" - 41" 39"-41" 17"-19"AREA OF REFUGE 5' - 0" TO CENTER OF SIGNNOTE: ALL SIGNAGE SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR EXCEPT SIGNS W/ TACTILE CHARACTERS ON PUSH SIDE OF DOORS WITH CLOSERS. PICTOGRAM SIGNS SHALL BE A MIN. OF 6" HEIGHT. SEE SECTION 703 OF THE ADA. 1 1/2"1 1/2" 2X6 ANCHORING BACK PLATE SECURE 2X6 TO 3-5/8" MTL. STUDS OR 2X WD. FRAMED STUDS SCREW 1-1/2" O.D. S.S. GRAB BAR - SEE RESTROOM FIXTURE ACCESSORIES SPECIFICATION FOR MFG. & MODEL NUMBER METAL WALL FLANGE NOTE: INSTALLATION MUST WITHSTAND 300 LBS. DOWNWARD PULL.VERTICAL SECTION PLAN VIEW 1-1/2" O.D. S.S. GRAB BAR - SEE RESTROOM FIXTURE ACCESSORIES SPECIFICATION FOR MFG. & MODEL NUMBER SCREW METAL WALL FLANGE 2X6 ANCHORING BACK PLATE SECURE 2X6 TO 3-5/8" MTL. STUDS OR 2X WD. FRAMED STUDS 1/2" GRAB BAR ESCUTCHEON STEEL SPACER 3/8" BOLT - WELD TO PLATE 1-1/4" X 1/8" X 3" STL PLATE MTL STUD @ EACH BOLTNOTES: 1. HOT WATER & DRAIN PIPES UNDER THE LAVATORY SHALL BE INSULATED OR CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE LAVATORY. 2. FAUCETS SHALL BE LEVER OPERATED, PUSH TYPE, OR ELECTRONICALLY CONTROLLED MECHANISMS. SELF-CLOSING VALVES SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. 3. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40" A.F.F. CLEAR FLOOR SPACE17" MIN.48" MIN.30" MIN.34" MAX.PROTECTED PIPING W/ CASWORK OF INSULATED PIPE COVER19" MAX.8" MIN.TO REFLECTIVE SURFACE40" MAX.11" MIN. 6"29" MAX.MIN.9"MIRROR 17" MIN. 19" MAX. 60" MIN.56" MIN.OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA T4 T3 T2 T7 T10 T9 T5T5T5 T6 T1 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21046 08-19-21 ADA STANDARDS DETAILS A004Carmel OverlookSTEMTREE LEARNING CENTER5790 E. Main StreetCarmel, IN 46033NOT TO SCALEA004 ADA WASHROOM ACCESSORIES2E NOT TO SCALEA004 ADA TOILET FIXTURES2C NOT TO SCALEA004 ADA SIGNAGE4C NOT TO SCALEA004 ADA GRAB BAR - PLAN/SECTION6C NOT TO SCALEA004 ADA GRAB BAR @ TOILET PARTITION6B NOT TO SCALEA004 ADA LAVATORY4B NOT TO SCALEA004 ADA TOILET CLEARANCE1C 1/2" = 1'-0"A004 TOILET ROOM ELEVATION 3A TOILET ROOM KEYNOTES T1 SURFACE MOUNTED TOILET PAPER DISPENSER T2 PAPER TOWEL DISPENSER T3 LIQUID SOAP DISPENSER T4 24" X 36" MIRROR T5 STAINLESS STEEL GRAB BARS, 36" L @ BACK WALL, 42" L @ SIDE WALL. IN ADDITION, A VERTICAL GRAB BAR 18" MIN. IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39" AND 41" ABOVE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39" AND 41" FROM THE REAR WALL. SEE DETAIL 7A/A605 FOR ADDITIONAL DIMENSIONS. T6 PROVIDE FLOOR MOUNTED TOILET AT ADA MOUNTING HEIGHT, SEE MEP DRAWINGS. T7 WALL HUNG PORCELAIN SINK, SEE MEP DRAWINGS. T9 STORAGE CABINET T10 MINIMUM 60" TURNING RADIUS CLEARANCE. GENERAL TOILET ROOM NOTES 1 SEE SHEET A004 FOR TYPICAL ADA MOUNTING HEIGHTS FOR ACCESSORIES. 2 CONTRACTOR TO PROCIDE BLOCKING IN WALLS FOR ALL TOILET ROOMS ACCESSORIES FOR OWNER AND CONTRACTOR SUPPLIED ITEMS. 3 COORDINATE FLOOR DRAIN (IF REQUIRED) LOCATIONS WITH MEP DRAWINGS. 4 CENTER ALL TILE PATTERNS, LEAVING EQUAL SIZE TILES ON EACH END. 5 DIMENSIONS ARE FINISHED FACE TO FINISHED FACE. # Revision Description Date Issued 09/22/21