HomeMy WebLinkAboutA100 NEW FLOOR PLAN & REFLECTED CEILINGF.E.C.S HSS SHS HS C 4 5 6 27' - 6" +/- OPEN AREA 100 LABORATORY 101 OFFICE 103 UTILITY CLOSET 104 TOILET 105 57' - 9 3/4"HALL 102 A130 1B 15' - 6" 4' - 5" 12' - 0"6' - 0" 2' - 6"8' - 8" 7' - 0 1/2" 8 1/2"9' - 10 1/2" 10' - 4 1/2" 7' - 3 1/4" 5' - 0 1/4" 22' - 6" 5' - 0" 8" 8" 5' - 0" 5' - 0" 1' - 0"8' - 9" 5' - 0" 8' - 9" 1 ELECT. PANEL 22 2 2 2' - 4" 13' - 2" 5 3 3 TYP. 3 TYP. 3 TYP. 3 4 2' - 1"D B1 C1 A1 A1 A1 A1 A1 A1 3103A104A 105A6 8 9 ETRETR10 12 1113137' - 9"RECESSED LED LIGHT 2' X 4' RECESSED LED FIXTURE NEW CEILING GRID ARMSTRONG FINE FISSURED 2x4 SQUARE LAY-IN (1729) PRELUDE 15/16" GRID EXISTING CEILING GRID WALL MOUNTED EXIT SIGN CEILING MOUNTED EXIT SIGN HVAC SUPPLY DIFFUSER HVAC RETURN GRILLE RESTROOM EXHAUST FANCEILING TYPE MATERIAL/DETAIL VARIATION CEILING HEIGHT CLG1 1' -0" C 4 5 6 CLG1 10' -0" C1 C1 C2 CLG1 10' -0" CLG1 10' - 0" CLG1 10' - 0" CLG1 10' -0" CLG1 10' - 0" DD RTU ABOVE www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21046 08-19-21 NEW FLOOR PLAN & REFLECTED CEILING PLAN A100Carmel OverlookSTEMTREE LEARNING CENTER5790 E. Main StreetCarmel, IN 46033GENERAL FLOOR PLAN NOTES A. CONTRACTOR TO FOLLOW ALL BUILDING/PROJECT STANDARDS. PROVIDE INTERIM LIFE SAFETY MEASURES AND FOLLOW ALL STATE AND LOCAL BUILDING CODES. IF CONTRARY INSTRUCTIONS ARE CONTAINED HEREIN, REQUEST CLARIFICATION FROM OWNER/ARCHITECT. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. C. SEE FLOOR PLAN FOR ADDITIONAL NOTES. D. ALL DIMENSIONS ARE FROM FACE OF STUD FRAMING TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. E. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONAL INFORMATION. F. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHOULD DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS OTHERWISE NOTED. G. SEE TYPICAL DETAILS FOR LOCATION OF HINGE SIDE OF DOOR JAMBS FROM ADJACENT WALLS IN METAL STUD WALLS UNLESS OTHERWISE NOTED. H. PROVIDE BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALL SUPPORTED ITEMS. SEE PLANS FOR CASEWORK LOCATIONS. I. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND STANDARD SPECIFICATIONS. J. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION. K. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION, ALIGN FACE OF NEW CONSTRUCTION WITH FACE OF EXISTING CONSTRUCTION. SKIM ENTIRE WALL SURFACE AS REQUIRED TO PROVIDE SMOOTH, FLUSH TRANSITIONS. L. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYPSUM BOARD. WALLS OVER 30 FEET IN LENGTH. COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. M. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SAND WALLS SMOOTH PRIOR TO PAINTING. PROVIDE BLANK COVER PLATES WHERE NEEDED. REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TO PAINTING AND REINSTALL WHEN COMPLETE. N. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BE SLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. O. SEE MEP DRAWINGS FOR RELATED LEGENDS AND SCOPE OF WORK. FLOOR PLAN NOTES 1 11" DEEP LAMINATE SHELVES ON KV STANDARDS, (5) ROWS (BY OWNER). SEE DETAIL 1E/A130. 2 BORROWED LITE, 5' HIGH X WIDTH INDICATED ON PLAN. BOTTOM OF WINDOW AT 3'-0" A.F.F. PROVIDE LAMINATED SAFETY GLASS IN TIMELY FRAMES. FRAME COLOR TO BE PREFINISHED WHITE. 3 F.F.E. BY TENANT. 4 NEW MOP SINK. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 5 UNDERCOUNTER REFRIGERATOR BY TENANT. 6 PLASTIC LAMINATE CASEWORK. SEE ELEVATION FOR ADDITIONAL INFORMATION. 7 POWER POLE. COORDINATE EXACT LOCATION WITH OWNER. 8 SEMI-RECESSED FIRE EXTINGUISHER CABINET. SEE DETAIL 4B/A131 FOR ADDITIONAL INFORMATION. 9 ALIGN FACE OF NEW DEMISING WALL WITH FACE OF EXISTING DEMISING WALL. 10 PROVIDE NEW PUSH/PULL HARDWARE ON EXISTING STOREFRONT DOOR. PROVIDE NEW WEATHERSTRIPPING AS REQUIRED. PROVIDE ALTERNATE PRICE TO REPLACE ENTIRE STOREFRONT DOOR AND HARDWARE. 11 NEW ADA RESTROOM. PROVIDE ADA TOILET WITH GRAB BARS, ADA SINK, 24"x36" MIRROR OVER SINK, PAPER TOWEL DISPENSER, SOAP DISPENSER, AND TOILET PAPER DISPENSER. SEE SHEET A004 FOR TOILET ROOM ELEVATION, REQUIRED CLEARANCES, MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. 12 THIS DOOR TO BE LOCKED DOWN. NOT REQUIRED FOR EGRESS. 13 PROVIDE BLOCKING IN WALL FOR UPPER WALL CABINETS. NORTH 1/4" = 1'-0"A100 NEW FLOOR PLAN4E REFLECTED CEILING PLAN NOTES C1 REPLACE EXISTING CAN LIGHTS WITH NEW LED FIXTURES. C2 REPAINT EXISTING BULKHEAD CEILING WHITE. REFLECTED CEILING PLAN LEGEND GENERAL CEILING PLAN NOTES 1. EXISTING TO REMAIN CEILING SYSTEMS SHOWN LIGHTER THAN NEW GRID SYSTEM. 2. NEW CEILING GRID CENTERED IN ROOM EACH WAY, UNLESS NOTED OTHERWISE. 3. UNLESS OTHERWISE NOTED, INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE OF ENDS OF ROOMS. IN GENERAL, PANELS SHOULD NOT BE LESS THAN 1'-0" WIDE. 4. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. 5. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES, MATERIALS, ETC. 6. THE ARCHITECTURAL REFLECTED CEILING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD CONDITIONS THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 7. SIZES AND SHAPES OF MECHANICAL EQUIPMENT, LIGHTING AND OTHER MISC. ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES AND CIRCUITING WITH ELECTRICAL ENGINEERING DOCUMENTS. 8. REFER TO WALL TYPE FOR ADDITIONAL INFORMATION & WALLS THAT BREAK GRID. 9. IF POSSIBLE, ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, SPEAKERS, ETC.) SHOULD BE CENTERED IN CEILING PANELS. 10. ALL NEW CEILING TILE (CLG1) TO BE ARMSTRONG FINE FISSURED 2x4 SQUARE LAY-IN (1729) WITH 15/16" PRELUDE SUSPENSION SYSTEM. NORTH 1/4" = 1'-0"A100 NEW REFLECTED CEILING PLAN1E # Revision Description Date Issued 09/22/21