HomeMy WebLinkAboutSTEMTREE_A001_Revision1_09-20-2021F.E.C.GFI
GFI> >> > >> >> > > > > > > > > >> >> >> >> > > > > >> >>
BUILDING / EXTERIOR ELEVATION
REFERENCE
ELEVATION REF.
SHEET REF.
WINDOW REFERENCE
A
ELEVATION OR WORK POINT
?NORTH
ORIENTATION REFERENCE
DOOR SYMBOL
?
?ROOM IDENTIFICATION
WALL TYPE
1 PLAN KEY NOTE
DEMOLITION PLAN KEY NOTE
NEW DOOR / RELOCATED DOOR
EXISTING DOOR
DEMO DOOR / WALL DEMO
EXISTING WALL
NEW WALL
EXISTING WALL TO BE REMOVED
PARTIAL HEIGHT WALL
5C
A600
DETAIL REFERENCE
1
A
1E
A200
3E
A600
INTERIOR ELEVATION REFERENCE
ELEVATION REF.
SHEET REF.
NEW WALL CONSTRUCTION
SECTION REFERENCE
ELEVATION REF.
SHEET REF.
1E
A200
73 '-0" TRAVEL DISTANCEFEC
EXT
1 OCCUP.
OPEN AREA 100
CLASSROOM FUNCTION = 20 OCCUP./SF
718 SF / 20 = 36 OCCUP.
LABORATORY 101
SHOP/VOCATIONAL FUNCTION = 50 OCCUP./SF
336 SF / 50 = 7 OCCUP.
FIRE EXTINGUISHER LOCATIONS
EXTE BUILDING EXIT
FEC
PATH OF EGRESS
APPLICABLE CODES:
2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE)
2010 INDIANA ENERGY CONSERVATION CODE (675-ISE 19-4)
2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE)
2012 INDIANA PLUMBING CODE (2006 INDIANA PLUMBING CODE WITH 2012 AMENDMENTS)
2009 INDIANA ELECTRICAL CODE (2008 NFPA 70)
2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE)
2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE)
2000 LIFE SAFETY CODE (NFPA 101)
PROJECT LOCATION:
5790 E. MAIN STREET
CARMEL, IN 46033
OCCUPANCY:
E OCCUPANCY (SEC. 309.1)
SQUARE FOOTAGE:
12,677 SF EXISTING BUILDING
1,645 SF REMODELED
HEIGHT:
BUILDING IS 1 STORIES
WIDTH OF EXITS:
EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15 INCHES
PER OCCUPANT. (SEC. 1005.2.3)
CONSTRUCTION TYPE:
TYPE II-B
FIRE SUPPRESSION SYSTEM:
PROJECT AREA: FULL SPRINKLER SUPPRESSION SYSTEM
FIRE RESISTIVE CORRIDORS:
NOT REQUIRED
SMOKE RESISTIVE CORRIDOR DOORS:
NOT REQUIRED
HAZARDOUS ROOMS:
NONE IN PROJECT
EXIT ACCESS TRAVEL DISTANCE:
EXIT ACCESS TRAVEL DISTANCE: NOT TO EXCEED 300 FEET.
DEAD END EXIT ACCESS: NOT TO EXCEED 50 FEET.
OCCUPANT LOAD:
OPEN AREA 100 = 36 OCCUPANTS
LABORATORY 101 = 7 OCCUPANTS
OFFICE 103 = 1 OCCUPANTS
TOTAL = 44 OCCUPANTS
(10 EMPLOYEES + 34 PUBLIC)
PLUMBING COUNT:
RESTROOMS - 1 UNISEX TOILET PROVIDED
ALARMS / FIRE DETECTION:
AUTOMATIC FIRE DETECTION REQUIRED
ACCESSIBILITY:
PER BUILDING OCCUPANCY / ANSI REQUIREMENTS
1
60" MIN.18"
FRONT APPROACH, PULL SIDE 48" MIN.12"
MIN.*
NOTE:
*IF BOTH A LATCH & CLOSER
ARE PROVIDED YX
NOTE:
X = 36" MIN. IF Y = 60";
X = 42" MIN. IF Y = 54"48" MIN.24"
NOTE:
Y = 54" MIN. IF DOOR HAS CLOSERY
42" MIN.**12"
MIN.*
NOTE:
*IF BOTH CLOSER AND LATCH
ARE PROVIDED.
**48" MIN. IF BOTH CLOSER
AND LATCH PROVIDED.
. 42" MIN.*24"
MIN.
HINGE APPROACH, PULL SIDE LATCH APPROACH, PULL SIDE
FRONT APPROACH, PUSH SIDE HINGE APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE
22"
MIN.*
NOTE:
*48" MIN. IF CLOSER IS
PROVIDED. 40" MAX.NOTE: SEE SPECIFICATIONS FOR
ADDITIONAL MOUNTING HEIGHTS.
TELEPHONE
MIRROR
TO BOTTOM OFREFLECTINGSURFACEDIAPER DISPENSER OR
SANITARY NAPKIN
DISPENSER
SOAP
DISPENSER
FIRE
EXTINGUISHER
CABINET (MAX.
4" PROJECTION)48" MAX.27" MIN.*SEE GUIDELINES FOR MOUNTING
HEIGHTS AT GRAB BARS.
NOTE: MOUNT ALL NON-HANDICAP ACCESSORIES
ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.WHEELCHAIRACCESSIBLEELECTRIC
WATER COOLER
34" MAX.SURFACE33" TO CHANGINGSTANDING HGT.38" - 43"GRAB BAR 33" - 36"ELECTRIC HAND
DRYER
SANITARY
NAPKIN
DISPOSAL*
WASTE RECEPTACLE /
PAPER TOWEL DISPENSER
S T
E
15" MIN.TO OPERABLE PARTS44" - 48"TO OPERABLE PARTS48".E 46" MAX.THERMOSTAT
SWITCH
ELEC. OUTLET
ABOVE 25"
DEEP
COUNTER
BABY CHANGING
STATION
www.studio3design.net
Phone: (317) 595.1000
8604 Allisonville Road, Suite 330
Indianapolis, IN 46250
A
B
C
D
E
1 2 3 4 5 6 7
A
B
C
D
E
THESE DRAWINGS ARE THE PROPERTY
OF STUDIO 3 DESIGN, INC. ALL RIGHTS
RESERVED
PROJECT NUMBER:
DATE:
CERTIFICATION:
SHEET DESCRIPTION:
SHEET NUMBER:
REVISION SCHEDULE:
1 2 3 4 5 6 7
21046
08-19-21
INFORMATION
SHEET & LIFE
SAFETY PLAN
A001Carmel OverlookSTEMTREE LEARNING CENTER5790 E. Main StreetCarmel, IN 46033GENERAL PROJECT NOTES
CONTRACTOR'S RESPONSIBILITIES:
1. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO BID SUBMITTAL PRIOR TO PROCEEDING WITH ANY WORK, OR RELATED WORK IN QUESTION.
2. THESE CONTRACT DOCUMENTS ARE INTENDED TO DESCRIBE ONLY THE SCOPE AND APPEARANCE OF THE REAL PROPERTY IMPROVEMENTS, INCLUDING THE PERFORMANCE AND
LEVEL OF QUALITY EXPECTED OF ITS COMPONENTS. IT IS INCUMBENT UPON THE CONTRACTOR TO INSURE THAT ALL WORK COMPLETED AND MATERIALS INSTALLED BE IN FULL
COMPLIANCE, AS A MINIMUM STANDARDS, WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES HAVING JURISDICTION.
3. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE DETAILS OF HIS TRADE. THEY ARE PERFORMANCE SPECIFICATIONS IN THAT THEY DO
REQUIRE THAT ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS,
EXCEPT IN THE CASE WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR
PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR(S) RESPONSIBLE FOR THE AFFECTED PORTION OF WORK.
4. ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM PERIOD OF ONE (1) YEAR, OR FOR THE PERIOD OF WARRANTY CUSTOMARY,
OR STIPULATED FOR, THE TRADE, CRAFT, OR PRODUCT, WHICHEVER IS LONGER. THEREFORE, ONLY COMPETENT MECHANICS CAPABLE OF PRODUCING GOOD WORKMANSHIP
CUSTOMARY TO THE TRADE SHALL BE USED.
5. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, OR THE AUTHORIZED, AGENT, TO DETERMINE ALL EXISTING MATERIALS TO BE SALVAGED AND RETAINED BY THE OWNER.
THE CONTRACTOR SHALL REMOVE SALVAGEABLE MATERIALS FROM THE SPACE AND STORE IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIALS, RUBBISH, AND
DEBRIS, SHALL BE REMOVED AND PROMPTLY DISPOSED OF BY THE CONTRACTOR AT AN OFFSITE LOCATION. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO
ASSURE THAT ALL PROPERTY IMPROVEMENTS (I.E. PARTITIONS, DOORS, FRAMES, CABINETS, CEILING GRID, CEILING TILE, AND THE ELECTRICAL AND MECHANICAL DEVICES, ETC.)
WHICH ARE TO REMAIN, ARE PROTECTED FROM DAMAGE OF ANY KIND.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER OR NOT IT CAN BE REPAIRED AND/OR
RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. THEY SHALL OBTAIN THE OWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR
TO STARTING CONSTRUCTION AND RECOMMEND AN ALLOWANCE IF NECESSARY. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM
TO THE STANDARDS ESTABLISHED AT THE TIME OF BID ACCEPTANCE.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS, SCHEDULE AND DEADLINES. THE
CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMS AFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST
FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SUCH LONG LEAD TIME ITEMS TO THE OWNER.
8. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS
CONSTRUCTION ACTIVITIES OCCURRING WITHIN OR ADJACENT TO OCCUPIED SPACE SHALL BE COORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE
DISTURBANCE TO BUILDING OCCUPANTS.
9. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND SHALL ARRANGE FOR USAGE OF THE FREIGHT
ELEVATOR (OR SUCH ELEVATOR DESIGNATED IF APPLICABLE). IF DELIVERY OF BUILDING MATERIALS INVOLVES THE USE OF OTHER FACILITIES, THE CONTRACTOR SHALL
COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE.
10. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING ACCOMPANIED BY THE ALTERNATIVE PRODUCT
INFORMATION TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10) WORKING DAYS PRIOR TO BID OPENING DATE.
SUBSTITUTIONS SHALL ONLY BE CONSIDERED IF THEY DO NOT SACRIFICE QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO
PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT EQUAL QUALITY TO THE PRODUCT SPECIFIED.
11. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FOR DIMENSION LOCATIONS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALL RESPECTS PRIOR TO THE FINAL
ACCEPTANCE, UNLESS OTHERWISE NOTED.
13. THE CONTRACTOR SHALL BE PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALS USED, AND DELIVER SAID IN
PRINTED MANNER TO THE OWNER AT THE TIME(S) DESIGNATED FOR O & M MANUAL DISBURSEMENTS. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR OWNERS
REPRESENTATIVE IN THE PROPER USE OF THE EQUIPMENT FURNISHED BY THEIR TRADE.
14. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP AT CLOSE-OUT, INCLUDING VACUUMING AND CLEANING ALL CARPETING.
15. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLES OF ALL FINISH MATERIALS
SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. SEE SPECIFICATIONS.
16. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS, AS THE ARCHITECT ASSUMES NO
RESPONSIBILITY FOR DRAWINGS, SCHEDULES, AND/OR SPECIFICATIONS FOR WORK ON THE PROJECT PREPARED OR ACCOMPLISHED BY OTHERS.
17. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES SUBMITTED BY THE CONTRACTOR (FOLLOWING A REVIEW BY THE GENERAL CONTRACTOR) FOR CONFORMITY WITH
THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS.
18. CONTRACTOR TO FOLLOW ALL BUILDING STANDARDS, INTERIM LIFE SAFETY MEASURES AND COORDINATE SCHEDULING OF WORK WITH AFFECTED OCCUPANTS (IF APPLICABLE)
PRIOR TO STARTING.
19. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING, OF ALL DISCREPANCIES. CONTRACTOR TO REVIEW AND RECORD
EXISTING CEILING FIELD CONDITIONS, LIGHT FIXTURE AND MEP SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL OTHER CEILING ITEMS LOCATIONS PRIOR TO
CONSTRUCTION. DISCREPANCIES IN THIS INFORMATION SHALL BE RECORDED IN THE CONSTRUCTION FIELD SET.
20. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER
TRADES.
21. ALL CONSTRUCTION TO MEET CURRENT NATIONAL, STATE AND LOCAL CODES, ORDINANCES AND ADA REGULATIONS.
22. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SAND ALL NEW TO EXISTING
TRANSITIONS SMOOTH PRIOR TO PAINTING. PATCH ALL AREAS WHERE RECEPTACLE OR FIXTURES ARE REMOVED. REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE
STROBES, ETC. PRIOR TO PAINTING AND REINSTALL WHEN COMPLETE.
23. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWING MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND
SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
24. GENERAL CONTRACTOR SHALL ACCOMMODATE TENANTS VENDORS DURING CONSTRUCTION AND WORK WITH THE OWNER TO SCHEDULE INSTALLATION OF OWNER SUPPLIED AND
INSTALLED ITEMS.
25. WHERE RATED WALLS ARE INDICATED, ENTIRE WALL ASSEMBLY SHALL BE CONTINUOUS AS SHOWN OR IMPLIED ON THE CONTRACT DOCUMENTS.
26. WHERE GAUGE OF METAL STUDS ARE NOT SPECIFICALLY SHOWN OR NOTED, PROVIDE GAUGE AS INDICATED IN THE GENERAL WALL TYPE NOTES.
27. CONTRACTOR TO REVISE, ADD OR RELOCATE FIRE STROBES, SPRINKLERS, AND OTHER LIFE SAFETY DEVICES AS NECESSARY TO MEET ALL APPLICABLE CODES, MAINTAIN LIFE
SAFETY AND/OR AS STIPULATED BY THE CONTRACT DOCUMENTS.
28. COMMENCEMENT OF WORK BY A CONTRACTOR OR SUBCONTRACTOR, CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACES IN QUESTION. IF ANY SUCH
CONDITIONS/SURFACES ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHOULD BE NOTIFIED AT ONCE BY THE SUBCONTRACTOR AND NO WORK DONE UNTIL CONDITIONS ARE
ACCEPTABLE.
29. CONTRACTORS ARE TO FOLLOW ALL MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION OF EQUIPMENT, MATERIALS, AND FINISHES.
31. CONTRACTOR TO PROVIDE DUST WALLS AT NECESSARY LOCATIONS.
32. TRANSPORT OF MATERIALS AND DEBRIS SHALL BE COORDINATED WITH THE FACILITY'S REPRESENTATIVES PRIOR TO THE START OF CONSTRUCTION.
GENERAL NOTES
1. CONTRACTOR TO VISIT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO START OF WORK. CONTRACTOR TO FIELD
VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING, OF ALL DISCREPANCIES. CONTRACTOR TO
DOCUMENT EXISTING FIELD CONDITIONS, LIGHT FIXTURE AND MEP SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL OTHER
CEILING ITEM LOCATIONS PRIOR TO CONSTRUCTION. THIS INFORMATION SHALL BE PROVIDED TO ARCHITECT FOR INCORPORATION INTO
A CONSTRUCTION SET.
2. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTING
CONDITIONS AND WITH ALL OTHER TRADES.
3. CONTRACTOR IS RESPONSIBLE TO PATCH/REPAIR/SEAL ALL NEW & EXISTING PENETRATIONS INTO RATED WALLS TO MAINTAIN RATED
ASSEMBLY.
4. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BE SLEEVED AND FIRE STOPPED AS NECESSARY TO
MAINTAIN RATINGS.
5. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWING MANUFACTURER'S
INSTRUCTIONS AND RECOMMENDATIONS AND SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND ACCESSORIES AS REQUIRED FOR
COMPLETE INSTALLATION.
6. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND TIMING OF CONSTRUCTION WITH ARCHITECT, TENANT, AND BUILDING
OWNER.
7. ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, AND STRUCTURES WITHIN THE WORK ZONE AND OR
WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TO EXECUTE THE WORK SHALL BE INCORPORATED IN THE CONTRACTOR'S BASE
BID.
FIELD VERIFICATION PRIOR TO BID
THE CONTRACTOR AND HIS SUBCONTRACTORS ARE REQUIRED TO VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO
THE ISSUANCE OF A BID. ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, AND STRUCTURES (BOTH ABOVE
AND BELOW GRADE AND AREA OF WORK) WITHIN THE WORK ZONE AND OR WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TO EXECUTE
THE WORK SHALL BE INCORPORATED IN THE CONTRACTORS BASE BID.
THE CONTRACTOR SHALL NOTIFY OWNER/DESIGN PROFESSIONAL (PRIOR TO BID) OF ANY ITEMS DISCOVERED DURING FIELD VERIFICATION
THAT THE CONTRACTOR FEELS REQUIRE ADDITIONAL CLARIFICATION FROM THE OWNER/DESIGN PROFESSIONAL IN ORDER TO APPROPRIATELY
BID THE PROJECT.
DRAFTING SYMBOLS
NORTH
3/16" = 1'-0"A001
LIFE SAFETY PLAN1C
CODE SUMMARY NOTES
12" = 1'-0"A001
ADA APPROACH LEGEND1E
12" = 1'-0"A001
ADA MOUNTING HEIGHTS4E
# Revision Description
Date
Issued
1 REVISED OCCUPANCY 09-20-21
1
1
1
09/22/21