Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A001 Abbreviations & General Notes
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032800 West Monon Green BlvdPEDCOR DESIGN GROUP LLC A001 Abbreviations & General Notes THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS #### LGA #### SCALE: NTS PLAN NORTH KEY PLAN Bldg I Revision ID Issue Date Issue Name 01 7/15/21 BP-1 Thursday, July 15, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Windsor - Building I/Building I WindsorA: Area, Acre; Alcove; Compressed Air Line AB: Anchor Bolt ABV: Above AC: Air Conditioning, Alternating Current ACC: Access ACF: Architectural Concrete Finish ACR: Acrylic ACST: Acoustic ACT: Actual AD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992 ADD: Addendum; Addition ADDL: Additional ADH: Adhesive ADJ: Adjust, Adjustable, Adjacent AF: Above the Floor AFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; Altitude ALUM: Aluminum AMB: Ambient AMT: Amount ANCH: Anchor, Anchorage ANOD: Anodized AP: Access Panel APPROX: Approximate APRVD: Approved APT: Apartment ARCH: Architect, Architectural AS: Acoustic Sealant ASC: Above Suspended Ceiling ASPH: Asphalt ASSEM: Assemble ASSY: Assembly ASTM: American Society for Testing and Materials ATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; Atmospheric AUTH: Authorized AUTO: Automatic AVG: Average B: Bathroom B TO B: Back to Back B & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, Ballast BC: Broom Closet BDY: Boundary BEL: Below BETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: Building BLK: Block BLKG: Blocking BLT-IN: Built-In BM: Beam, Bench Mark BN: Bullnose BNT: Bent BOT: Bottom BP: Base Plate BPL: Bearing Plate BR: Bedroom BRDG: Bridging BRG: Bearing BRK: Brick BRKT: Bracket BRS: Brass BRZ: Bronze BS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up Roof BW: Both Ways C: Curb, Clock Outlet C/C: Center to Center CAB: Cabinet CAP: Capacity CAR: Carpet CAV: Cavity CCW: Counter Clockwise CCTV: Closed Circuit TV CEM: Cement CER: Ceramic CF: Cubic Feet CFL: Counterflashing CFS: Cold Formed Steel CG: Corner Guard CH: Coat Hook CHR: Chilled Water Return CHAM: Chamfer CHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-Place CIR: Circle, Circular CIRC: Circumference CITG: Clear Insulating Tempered Glass CJ: Control Joint CK: Caulking CL: Centerline, Clearance, Closure, Class CLG: Ceiling CLL: Contract Limit Line CLO: Closet CLR: Clear CLR OPG: Clear Opening CMP: Corrugated Metal Pipe CMU: Concrete Masonry Unit CND: Conduit CNTR: Counter COAX: Coaxial C.O.: Cased Opening CO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: Column COM: Common CON: Construction CONC: Concrete CONN: Connection CONT: Continuous, Continue, Control COP: Copper COR: Corner CORR: Corridor, Corrugate CR: Curtain Rod CRPT: Carpet CRS: Course, Cold Rolled Steel CS: Cast Stone CSG: Casing CSK: Countersink CSMT: Casement CT: Ceramic Tile CTD: Coated CTR: Center CW: Clockwise, Cold Water CWR: Condensate Waste Return CWS: Condensate Waste Supply CY: Cubic Yard CYL: Cylinder CYL L: Cylinder Lock DA: Double Acting DB: Decibel DBL: Double DC: Direct Current DD: Driveway Drain, Deck Drain DEG: Degree DEGF: Degree Farenheit DEMO: Demolition DEPT: Department DF: Drinking Fountain DH: Double Hung DIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: Dimension DISL: Disposal DIV: Division DL: Dead Load DMT: Demountable DN: Down DO: Door Opening DP: Dampproofing DPR: Damper DR: Door, Dining Room DS: Downspout DSP: Dry Standpipe DT: Drain Tile DTL: Detail DVTL: Dovetail DWG: Drawing DWGS: Drawings DWR: Drawer E: East E TO E: End to End EA: Each EB: Expansion Bolt EC: Exposed Construction ECP: Exposed Construction Painted EE: Each End EF: Each Face EG: Edge Grain EIFS: Exterior Insulation and Finish System EJ: Expansion Joint ELEC: Electrical ELEV: Elevator, Elevation EMER: Emergency ENAM: Enamel ENCL: Enclosure ENG: Engineer ENT: Entrance EPDM: Ethylene Propylene Diene Monomer EQ: Equal EQUIP: Equipment ERP: Emergency Receptacle Panel EST: Estimate EW: Each Way EX: Exit EXC: Excavate EXEC: Executive EXH: Exhaust EXH AIR: Exhaust Air EXIST: Existing EXP: Expansion, Exposed EXT: Exterior F: Degrees Fahrenheit F TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: Fabricate FACP: Fire Alarm Control Panel FAG: Fire Alarm Gong FAST: Fastener, Fasten FBD: Fiberboard FBRK: Fire Brick FD: Floor drain FDC: Fire Department Connection FDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher Cabinet FF: Finished Floor, Factory Finish FFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & Equipment FFL: Finished Floor Line FGL: Fiberglass FGR: Fiberglass reinforced FH: Fire Hose FHC: Fire Hose Cabinet FHWS: Flat Head Wood Screw FHY: Fire Hydrant FIN: Finish, finished FIX: Fixture FLG: Flashing FLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin Dispenser FO: Finished Opening FOC: Face of Concrete FOF: Face of Finish FOS: Face of Studs FP: Fireproof FPL: Fireplace FR: Front, Fire Riser FRM: Frame FRT: Fire Retardant FS: Floor Sink FT: Foot, Feet, Fully Tempered FTG: Footing, Fitting FURN: Furnish, Furniture FURR: Furring FUT: Future G: Gas GA: Gauge GAL: Gallon GALV: Galvanized GC: General Contractor GEN: General GFCI: Ground Fault Circuit Interrupted GFI: Ground Fault Interrupted GFRC: Glass Fiber Reinforced Concrete GI: Galvanized Iron GKT: Gasket GL: Glass GLZ: Glaze GMU: Glazed Masonry Unit GND: Ground GOVT: Government GP: Galvanized Pipe GR: Grade GRAN: Granite GRTG: Grating GT: Grout GV: Galvanized GVL: Gravel GYP: Gypsum GYP BD: Gypsum Board HB: Hose Bib HBD: Hardboard HC: Hollow Core HD: Heavy Duty HDR: Header HDPE: High Density Polyethylene HDW: Hardware HDWD: Hardwood HGR: Hanger HGT: Height HK: Hook or Hooks HM: Hollow Metal HMP: Hollow Metal, Painted HOR: Horizontal HR: Hour HRS: Hot Rolled Steel, Hours HT: Height HTR: Heater HV: High Voltage HVAC: Heating, Ventilating & Air Conditioning HW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water Supply HYD: Hydraulic I: Iron ID: Inside Diameter IN: Inch INC: Incandescent INCL: Incline, Include INCR: Increase INFO: Information INSP: Inspect INSTL: Install INSUL: Insulation INT: Interior INV: Invert IP: Iron Pipe J: Joist JB: Junction Box JC: Janitor's Closet JF: Joint Filler K: Kickplate KIT: Kitchen KS: Kitchen Sink KW: Kilowatt L: Left, Length LAD: Ladder LAM: Laminate, Laminated LB: Pound (weight), Lag Bolt LBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen Closet LCM: Lead Coated Metal LD: Leader Drain LH: Left Hand LIB: Library LINO: Linoleum LIQ: Liquid LKR: Locker LL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: Locations LR: Living Room LS: Loud Speaker LT: Light LTG: Lighting LTL: Lintel LV: Low Voltage LVR: Louver LW: Light Weight LWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: Marble MAS: Masonry MATL: Material MAX: Maximum MB: Mail Box MC: Medicine Cabinet MECH: Mechanical MED: Medium MEMB: Membrane MET: Metal MEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, Manufacturing MH: Manhole MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MLDG: Molding MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, Mounted MTL: Material, Metal MTR: Motor MULL: Mullion MWK: Millwork N: North NATL: Natural NEC: National Electrical Code NEUT: Neutral NI: Nickel NIC: Not In Contract NO: Number NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to Out OA: Outside Air, Overall OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office OH: Overhead OHD: Overhead Door OI: Ornamental Iron OPNG: Opening OPP: Opposite OPP H: Opposite Hand ORN: Ornamental OUT: Outlet OVFL: Overflow OZ: Ounce P: Paint P. LAM: Plastic Laminate P SL: Pipe Sleeve PAR: Parallel PARTN: Partition PB: Panic Bar PBD: Particle Board PC: Precast Concrete PCF: Pounds per cubic foot PD: Pump Discharge, Plaza Drain PE: Professional Engineer PED: Pedestal, Pedestrian PERF: Perforate PERIM: Perimeter PERP: Perpendicular PFN: Prefinished PH: Phase, Phone PKG: Parking PKWY: Parkway PL: Property Line PLAS: Plastic PLAS LAM: Plastic Laminate PLF: Pounds Per Lineal Foot PLMBG: Plumbing PLTF: Platform PLWD: Plywood PNL: Panel PNT: Paint POL: Polish, Polished PORC: Porcelain PORT: Portable POT W: Potable Water PP: Precast Panel PR: Pair PRC: Precast PREFAB: Prefabricated PRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: Premolded PROT: Protection, Protective PRSTR: Prestressed PRTN: Partition PS: Plumbing Stack PSC: Prestressed Concrete PSF: Pounds per square foot PSI: Pounds per square inch PT: Point PTC: Post-Tensioned Concrete PTD: Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PV: Paving PVG: Paving PVMT: Pavement PVT: Private PWR: Power QUAL: Quality QT: Quarry Tile, Quart QTR: Quarter QTY: Quantity R: Radius R & S: Rod and Sealant RA: Return Air, Registered Architect RAD: Radiator RB: Rubber RBT: Rabbet RCP: Reflected Ceiling Plan RD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year ABBREVIATIONS A: Area, Acre; Alcove; Compressed Air LineAB: Anchor BoltABV: Above AC: Air Conditioning, Alternating CurrentACC: Access ACF: Architectural Concrete FinishACR: AcrylicACST: AcousticACT: ActualAD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992ADD: Addendum; Addition ADDL: AdditionalADH: AdhesiveADJ: Adjust, Adjustable, Adjacent AF: Above the FloorAFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; AltitudeALUM: AluminumAMB: AmbientAMT: AmountANCH: Anchor, AnchorageANOD: Anodized AP: Access PanelAPPROX: ApproximateAPRVD: Approved APT: ApartmentARCH: Architect, ArchitecturalAS: Acoustic SealantASC: Above Suspended CeilingASPH: AsphaltASSEM: AssembleASSY: Assembly ASTM: American Society for Testing and MaterialsATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; AtmosphericAUTH: Authorized AUTO: Automatic AVG: AverageB: BathroomB TO B: Back to BackB & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, BallastBC: Broom ClosetBDY: BoundaryBEL: BelowBETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: BuildingBLK: Block BLKG: BlockingBLT-IN: Built-In BM: Beam, Bench MarkBN: BullnoseBNT: Bent BOT: BottomBP: Base Plate BPL: Bearing PlateBR: BedroomBRDG: Bridging BRG: BearingBRK: BrickBRKT: Bracket BRS: BrassBRZ: BronzeBS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up RoofBW: Both WaysC: Curb, Clock Outlet C/C: Center to CenterCAB: CabinetCAP: Capacity CAR: CarpetCAV: CavityCCW: Counter Clockwise CCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCFL: CounterflashingCFS: Cold Formed SteelCG: Corner GuardCH: Coat HookCHR: Chilled Water Return CHAM: ChamferCHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-PlaceCIR: Circle, CircularCIRC: CircumferenceCITG: Clear Insulating Tempered GlassCJ: Control JointCK: Caulking CL: Centerline, Clearance, Closure, Class CLG: CeilingCLL: Contract Limit Line CLO: ClosetCLR: ClearCLR OPG: Clear OpeningCMP: Corrugated Metal PipeCMU: Concrete Masonry UnitCND: ConduitCNTR: CounterCOAX: CoaxialC.O.: Cased OpeningCO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: Column COM: Common CON: Construction CONC: Concrete CONN: Connection CONT: Continuous, Continue, Control COP: Copper COR: Corner CORR: Corridor, Corrugate CR: Curtain Rod CRPT: Carpet CRS: Course, Cold Rolled Steel CS: Cast Stone CSG: Casing CSK: Countersink CSMT: Casement CT: Ceramic Tile CTD: Coated CTR: Center CW: Clockwise, Cold Water CWR: Condensate Waste Return CWS: Condensate Waste Supply CY: Cubic Yard CYL: Cylinder CYL L: Cylinder Lock DA: Double Acting DB: Decibel DBL: Double DC: Direct Current DD: Driveway Drain, Deck Drain DEG: Degree DEGF: Degree Farenheit DEMO: Demolition DEPT: Department DF: Drinking Fountain DH: Double Hung DIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: Dimension DISL: Disposal DIV: Division DL: Dead Load DMT: Demountable DN: Down DO: Door Opening DP: Dampproofing DPR: Damper DR: Door, Dining Room DS: Downspout DSP: Dry Standpipe DT: Drain Tile DTL: Detail DVTL: Dovetail DWG: Drawing DWGS: Drawings DWR: Drawer E: East E TO E: End to End EA: Each EB: Expansion Bolt EC: Exposed Construction ECP: Exposed Construction Painted EE: Each End EF: Each Face EG: Edge Grain EIFS: Exterior Insulation and Finish System EJ: Expansion Joint ELEC: Electrical ELEV: Elevator, Elevation EMER: Emergency ENAM: Enamel ENCL: Enclosure ENG: Engineer ENT: Entrance EPDM: Ethylene Propylene Diene Monomer EQ: Equal EQUIP: Equipment ERP: Emergency Receptacle Panel EST: Estimate EW: Each Way EX: Exit EXC: Excavate EXEC: Executive EXH: Exhaust EXH AIR: Exhaust Air EXIST: Existing EXP: Expansion, Exposed EXT: Exterior F: Degrees Fahrenheit F TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: Fabricate FACP: Fire Alarm Control Panel FAG: Fire Alarm Gong FAST: Fastener, Fasten FBD: Fiberboard FBRK: Fire Brick FD: Floor drain FDC: Fire Department Connection FDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher Cabinet FF: Finished Floor, Factory Finish FFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & Equipment FFL: Finished Floor Line FGL: Fiberglass FGR: Fiberglass reinforced FH: Fire Hose FHC: Fire Hose Cabinet FHWS: Flat Head Wood Screw FHY: Fire Hydrant FIN: Finish, finished FIX: Fixture FLG: Flashing FLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin Dispenser FO: Finished Opening FOC: Face of Concrete FOF: Face of Finish FOS: Face of Studs FP: Fireproof FPL: Fireplace FR: Front, Fire Riser FRM: Frame FRT: Fire Retardant FS: Floor Sink FT: Foot, Feet, Fully Tempered FTG: Footing, Fitting FURN: Furnish, Furniture FURR: Furring FUT: Future G: Gas GA: Gauge GAL: Gallon GALV: Galvanized GC: General Contractor GEN: General GFCI: Ground Fault Circuit Interrupted GFI: Ground Fault Interrupted GFRC: Glass Fiber Reinforced Concrete GI: Galvanized Iron GKT: Gasket GL: Glass GLZ: Glaze GMU: Glazed Masonry Unit GND: Ground GOVT: Government GP: Galvanized Pipe GR: Grade GRAN: Granite GRTG: Grating GT: Grout GV: Galvanized GVL: Gravel GYP: Gypsum GYP BD: Gypsum Board HB: Hose Bib HBD: Hardboard HC: Hollow Core HD: Heavy Duty HDR: Header HDPE: High Density Polyethylene HDW: Hardware HDWD: Hardwood HGR: Hanger HGT: Height HK: Hook or Hooks HM: Hollow Metal HMP: Hollow Metal, Painted HOR: Horizontal HR: Hour HRS: Hot Rolled Steel, Hours HT: Height HTR: Heater HV: High Voltage HVAC: Heating, Ventilating & Air Conditioning HW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water Supply HYD: Hydraulic I: Iron ID: Inside Diameter IN: Inch INC: Incandescent INCL: Incline, Include INCR: Increase INFO: Information INSP: Inspect INSTL: Install INSUL: Insulation INT: Interior INV: Invert IP: Iron Pipe J: Joist JB: Junction Box JC: Janitor's Closet JF: Joint Filler K: Kickplate KIT: Kitchen KS: Kitchen Sink KW: Kilowatt L: Left, Length LAD: Ladder LAM: Laminate, Laminated LB: Pound (weight), Lag Bolt LBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen Closet LCM: Lead Coated Metal LD: Leader Drain LH: Left Hand LIB: Library LINO: Linoleum LIQ: Liquid LKR: Locker LL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: Locations LR: Living Room LS: Loud Speaker LT: Light LTG: Lighting LTL: Lintel LV: Low Voltage LVR: Louver LW: Light Weight LWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: Marble MAS: Masonry MATL: Material MAX: Maximum MB: Mail Box MC: Medicine Cabinet MECH: Mechanical MED: Medium MEMB: Membrane MET: Metal MEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, Manufacturing MH: Manhole MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MLDG: Molding MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, Mounted MTL: Material, Metal MTR: Motor MULL: Mullion MWK: Millwork N: North NATL: Natural NEC: National Electrical Code NEUT: Neutral NI: Nickel NIC: Not In Contract NO: Number NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to Out OA: Outside Air, Overall OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office OH: Overhead OHD: Overhead Door OI: Ornamental Iron OPNG: Opening OPP: Opposite OPP H: Opposite Hand ORN: Ornamental OUT: Outlet OVFL: Overflow OZ: Ounce P: Paint P. LAM: Plastic Laminate P SL: Pipe Sleeve PAR: Parallel PARTN: Partition PB: Panic Bar PBD: Particle Board PC: Precast Concrete PCF: Pounds per cubic foot PD: Pump Discharge, Plaza Drain PE: Professional Engineer PED: Pedestal, Pedestrian PERF: Perforate PERIM: Perimeter PERP: Perpendicular PFN: Prefinished PH: Phase, Phone PKG: Parking PKWY: Parkway PL: Property Line PLAS: Plastic PLAS LAM: Plastic Laminate PLF: Pounds Per Lineal Foot PLMBG: Plumbing PLTF: Platform PLWD: Plywood PNL: Panel PNT: Paint POL: Polish, Polished PORC: Porcelain PORT: Portable POT W: Potable Water PP: Precast Panel PR: Pair PRC: Precast PREFAB: Prefabricated PRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: Premolded PROT: Protection, Protective PRSTR: Prestressed PRTN: Partition PS: Plumbing Stack PSC: Prestressed Concrete PSF: Pounds per square foot PSI: Pounds per square inch PT: Point PTC: Post-Tensioned Concrete PTD: Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PV: Paving PVG: Paving PVMT: Pavement PVT: Private PWR: Power QUAL: Quality QT: Quarry Tile, Quart QTR: Quarter QTY: Quantity R: Radius R & S: Rod and Sealant RA: Return Air, Registered Architect RAD: Radiator RB: Rubber RBT: Rabbet RCP: Reflected Ceiling Plan RD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year A: Area, Acre; Alcove; Compressed Air LineAB: Anchor BoltABV: Above AC: Air Conditioning, Alternating CurrentACC: Access ACF: Architectural Concrete FinishACR: AcrylicACST: AcousticACT: ActualAD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992ADD: Addendum; Addition ADDL: AdditionalADH: AdhesiveADJ: Adjust, Adjustable, Adjacent AF: Above the FloorAFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; AltitudeALUM: AluminumAMB: AmbientAMT: AmountANCH: Anchor, AnchorageANOD: Anodized AP: Access PanelAPPROX: ApproximateAPRVD: Approved APT: ApartmentARCH: Architect, ArchitecturalAS: Acoustic SealantASC: Above Suspended CeilingASPH: AsphaltASSEM: AssembleASSY: Assembly ASTM: American Society for Testing and MaterialsATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; AtmosphericAUTH: Authorized AUTO: Automatic AVG: AverageB: BathroomB TO B: Back to BackB & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, BallastBC: Broom ClosetBDY: BoundaryBEL: BelowBETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: BuildingBLK: Block BLKG: BlockingBLT-IN: Built-In BM: Beam, Bench MarkBN: BullnoseBNT: Bent BOT: BottomBP: Base Plate BPL: Bearing PlateBR: BedroomBRDG: Bridging BRG: BearingBRK: BrickBRKT: Bracket BRS: BrassBRZ: BronzeBS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up RoofBW: Both WaysC: Curb, Clock Outlet C/C: Center to CenterCAB: CabinetCAP: Capacity CAR: CarpetCAV: CavityCCW: Counter Clockwise CCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCFL: CounterflashingCFS: Cold Formed SteelCG: Corner GuardCH: Coat HookCHR: Chilled Water Return CHAM: ChamferCHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-PlaceCIR: Circle, CircularCIRC: CircumferenceCITG: Clear Insulating Tempered GlassCJ: Control JointCK: Caulking CL: Centerline, Clearance, Closure, Class CLG: CeilingCLL: Contract Limit Line CLO: ClosetCLR: ClearCLR OPG: Clear OpeningCMP: Corrugated Metal PipeCMU: Concrete Masonry UnitCND: ConduitCNTR: CounterCOAX: CoaxialC.O.: Cased OpeningCO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: ColumnCOM: CommonCON: ConstructionCONC: Concrete CONN: Connection CONT: Continuous, Continue, ControlCOP: CopperCOR: Corner CORR: Corridor, CorrugateCR: Curtain RodCRPT: CarpetCRS: Course, Cold Rolled SteelCS: Cast Stone CSG: Casing CSK: CountersinkCSMT: Casement CT: Ceramic Tile CTD: Coated CTR: CenterCW: Clockwise, Cold WaterCWR: Condensate Waste ReturnCWS: Condensate Waste SupplyCY: Cubic Yard CYL: Cylinder CYL L: Cylinder LockDA: Double ActingDB: Decibel DBL: DoubleDC: Direct CurrentDD: Driveway Drain, Deck DrainDEG: DegreeDEGF: Degree Farenheit DEMO: DemolitionDEPT: DepartmentDF: Drinking FountainDH: Double HungDIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: DimensionDISL: DisposalDIV: DivisionDL: Dead LoadDMT: DemountableDN: Down DO: Door OpeningDP: Dampproofing DPR: Damper DR: Door, Dining Room DS: DownspoutDSP: Dry Standpipe DT: Drain TileDTL: Detail DVTL: DovetailDWG: DrawingDWGS: DrawingsDWR: DrawerE: EastE TO E: End to EndEA: EachEB: Expansion BoltEC: Exposed Construction ECP: Exposed Construction Painted EE: Each EndEF: Each FaceEG: Edge Grain EIFS: Exterior Insulation and Finish SystemEJ: Expansion JointELEC: ElectricalELEV: Elevator, Elevation EMER: EmergencyENAM: Enamel ENCL: EnclosureENG: Engineer ENT: EntranceEPDM: Ethylene Propylene Diene MonomerEQ: Equal EQUIP: EquipmentERP: Emergency Receptacle PanelEST: EstimateEW: Each WayEX: ExitEXC: ExcavateEXEC: ExecutiveEXH: ExhaustEXH AIR: Exhaust AirEXIST: Existing EXP: Expansion, Exposed EXT: ExteriorF: Degrees FahrenheitF TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: FabricateFACP: Fire Alarm Control PanelFAG: Fire Alarm Gong FAST: Fastener, FastenFBD: FiberboardFBRK: Fire Brick FD: Floor drainFDC: Fire Department ConnectionFDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher CabinetFF: Finished Floor, Factory FinishFFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor Line FGL: FiberglassFGR: Fiberglass reinforced FH: Fire HoseFHC: Fire Hose CabinetFHWS: Flat Head Wood ScrewFHY: Fire HydrantFIN: Finish, finished FIX: FixtureFLG: FlashingFLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin DispenserFO: Finished Opening FOC: Face of Concrete FOF: Face of Finish FOS: Face of Studs FP: Fireproof FPL: Fireplace FR: Front, Fire Riser FRM: Frame FRT: Fire Retardant FS: Floor Sink FT: Foot, Feet, Fully Tempered FTG: Footing, Fitting FURN: Furnish, Furniture FURR: Furring FUT: Future G: Gas GA: Gauge GAL: Gallon GALV: Galvanized GC: General Contractor GEN: General GFCI: Ground Fault Circuit Interrupted GFI: Ground Fault Interrupted GFRC: Glass Fiber Reinforced Concrete GI: Galvanized Iron GKT: Gasket GL: Glass GLZ: Glaze GMU: Glazed Masonry Unit GND: Ground GOVT: Government GP: Galvanized Pipe GR: Grade GRAN: Granite GRTG: Grating GT: Grout GV: Galvanized GVL: Gravel GYP: Gypsum GYP BD: Gypsum Board HB: Hose Bib HBD: Hardboard HC: Hollow Core HD: Heavy Duty HDR: Header HDPE: High Density Polyethylene HDW: Hardware HDWD: Hardwood HGR: Hanger HGT: Height HK: Hook or Hooks HM: Hollow Metal HMP: Hollow Metal, Painted HOR: Horizontal HR: Hour HRS: Hot Rolled Steel, Hours HT: Height HTR: Heater HV: High Voltage HVAC: Heating, Ventilating & Air Conditioning HW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water Supply HYD: Hydraulic I: Iron ID: Inside Diameter IN: Inch INC: Incandescent INCL: Incline, Include INCR: Increase INFO: Information INSP: Inspect INSTL: Install INSUL: Insulation INT: Interior INV: Invert IP: Iron Pipe J: Joist JB: Junction Box JC: Janitor's Closet JF: Joint Filler K: Kickplate KIT: Kitchen KS: Kitchen Sink KW: Kilowatt L: Left, Length LAD: Ladder LAM: Laminate, Laminated LB: Pound (weight), Lag Bolt LBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen Closet LCM: Lead Coated Metal LD: Leader Drain LH: Left Hand LIB: Library LINO: Linoleum LIQ: Liquid LKR: Locker LL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: Locations LR: Living Room LS: Loud Speaker LT: Light LTG: Lighting LTL: Lintel LV: Low Voltage LVR: Louver LW: Light Weight LWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: Marble MAS: Masonry MATL: Material MAX: Maximum MB: Mail Box MC: Medicine Cabinet MECH: Mechanical MED: Medium MEMB: Membrane MET: Metal MEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, Manufacturing MH: Manhole MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MLDG: Molding MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, Mounted MTL: Material, Metal MTR: Motor MULL: Mullion MWK: Millwork N: North NATL: Natural NEC: National Electrical Code NEUT: Neutral NI: Nickel NIC: Not In Contract NO: Number NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to Out OA: Outside Air, Overall OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office OH: Overhead OHD: Overhead Door OI: Ornamental Iron OPNG: Opening OPP: Opposite OPP H: Opposite Hand ORN: Ornamental OUT: Outlet OVFL: Overflow OZ: Ounce P: Paint P. LAM: Plastic Laminate P SL: Pipe Sleeve PAR: Parallel PARTN: Partition PB: Panic Bar PBD: Particle Board PC: Precast Concrete PCF: Pounds per cubic foot PD: Pump Discharge, Plaza Drain PE: Professional Engineer PED: Pedestal, Pedestrian PERF: Perforate PERIM: Perimeter PERP: Perpendicular PFN: Prefinished PH: Phase, Phone PKG: Parking PKWY: Parkway PL: Property Line PLAS: Plastic PLAS LAM: Plastic Laminate PLF: Pounds Per Lineal Foot PLMBG: Plumbing PLTF: Platform PLWD: Plywood PNL: Panel PNT: Paint POL: Polish, Polished PORC: Porcelain PORT: Portable POT W: Potable Water PP: Precast Panel PR: Pair PRC: Precast PREFAB: Prefabricated PRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: Premolded PROT: Protection, Protective PRSTR: Prestressed PRTN: Partition PS: Plumbing Stack PSC: Prestressed Concrete PSF: Pounds per square foot PSI: Pounds per square inch PT: Point PTC: Post-Tensioned Concrete PTD: Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PV: Paving PVG: Paving PVMT: Pavement PVT: Private PWR: Power QUAL: Quality QT: Quarry Tile, Quart QTR: Quarter QTY: Quantity R: Radius R & S: Rod and Sealant RA: Return Air, Registered Architect RAD: Radiator RB: Rubber RBT: Rabbet RCP: Reflected Ceiling Plan RD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year A: Area, Acre; Alcove; Compressed Air LineAB: Anchor BoltABV: Above AC: Air Conditioning, Alternating CurrentACC: Access ACF: Architectural Concrete FinishACR: AcrylicACST: AcousticACT: ActualAD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992ADD: Addendum; Addition ADDL: AdditionalADH: AdhesiveADJ: Adjust, Adjustable, Adjacent AF: Above the FloorAFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; AltitudeALUM: AluminumAMB: AmbientAMT: AmountANCH: Anchor, AnchorageANOD: Anodized AP: Access PanelAPPROX: ApproximateAPRVD: Approved APT: ApartmentARCH: Architect, ArchitecturalAS: Acoustic SealantASC: Above Suspended CeilingASPH: AsphaltASSEM: AssembleASSY: Assembly ASTM: American Society for Testing and MaterialsATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; AtmosphericAUTH: Authorized AUTO: Automatic AVG: AverageB: BathroomB TO B: Back to BackB & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, BallastBC: Broom ClosetBDY: BoundaryBEL: BelowBETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: BuildingBLK: Block BLKG: BlockingBLT-IN: Built-In BM: Beam, Bench MarkBN: BullnoseBNT: Bent BOT: BottomBP: Base Plate BPL: Bearing PlateBR: BedroomBRDG: Bridging BRG: BearingBRK: BrickBRKT: Bracket BRS: BrassBRZ: BronzeBS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up RoofBW: Both WaysC: Curb, Clock Outlet C/C: Center to CenterCAB: CabinetCAP: Capacity CAR: CarpetCAV: CavityCCW: Counter Clockwise CCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCFL: CounterflashingCFS: Cold Formed SteelCG: Corner GuardCH: Coat HookCHR: Chilled Water Return CHAM: ChamferCHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-PlaceCIR: Circle, CircularCIRC: CircumferenceCITG: Clear Insulating Tempered GlassCJ: Control JointCK: Caulking CL: Centerline, Clearance, Closure, Class CLG: CeilingCLL: Contract Limit Line CLO: ClosetCLR: ClearCLR OPG: Clear OpeningCMP: Corrugated Metal PipeCMU: Concrete Masonry UnitCND: ConduitCNTR: CounterCOAX: CoaxialC.O.: Cased OpeningCO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: ColumnCOM: CommonCON: ConstructionCONC: Concrete CONN: Connection CONT: Continuous, Continue, ControlCOP: CopperCOR: Corner CORR: Corridor, CorrugateCR: Curtain RodCRPT: CarpetCRS: Course, Cold Rolled SteelCS: Cast Stone CSG: Casing CSK: CountersinkCSMT: Casement CT: Ceramic Tile CTD: Coated CTR: CenterCW: Clockwise, Cold WaterCWR: Condensate Waste ReturnCWS: Condensate Waste SupplyCY: Cubic Yard CYL: Cylinder CYL L: Cylinder LockDA: Double ActingDB: Decibel DBL: DoubleDC: Direct CurrentDD: Driveway Drain, Deck DrainDEG: DegreeDEGF: Degree Farenheit DEMO: DemolitionDEPT: DepartmentDF: Drinking FountainDH: Double HungDIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: DimensionDISL: DisposalDIV: DivisionDL: Dead LoadDMT: DemountableDN: Down DO: Door OpeningDP: Dampproofing DPR: Damper DR: Door, Dining Room DS: DownspoutDSP: Dry Standpipe DT: Drain TileDTL: Detail DVTL: DovetailDWG: DrawingDWGS: DrawingsDWR: DrawerE: EastE TO E: End to EndEA: EachEB: Expansion BoltEC: Exposed Construction ECP: Exposed Construction Painted EE: Each EndEF: Each FaceEG: Edge Grain EIFS: Exterior Insulation and Finish SystemEJ: Expansion JointELEC: ElectricalELEV: Elevator, Elevation EMER: EmergencyENAM: Enamel ENCL: EnclosureENG: Engineer ENT: EntranceEPDM: Ethylene Propylene Diene MonomerEQ: Equal EQUIP: EquipmentERP: Emergency Receptacle PanelEST: EstimateEW: Each WayEX: ExitEXC: ExcavateEXEC: ExecutiveEXH: ExhaustEXH AIR: Exhaust AirEXIST: Existing EXP: Expansion, Exposed EXT: ExteriorF: Degrees FahrenheitF TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: FabricateFACP: Fire Alarm Control PanelFAG: Fire Alarm Gong FAST: Fastener, FastenFBD: FiberboardFBRK: Fire Brick FD: Floor drainFDC: Fire Department ConnectionFDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher CabinetFF: Finished Floor, Factory FinishFFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor Line FGL: FiberglassFGR: Fiberglass reinforced FH: Fire HoseFHC: Fire Hose CabinetFHWS: Flat Head Wood ScrewFHY: Fire HydrantFIN: Finish, finished FIX: FixtureFLG: FlashingFLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin DispenserFO: Finished OpeningFOC: Face of ConcreteFOF: Face of FinishFOS: Face of StudsFP: Fireproof FPL: FireplaceFR: Front, Fire Riser FRM: FrameFRT: Fire RetardantFS: Floor SinkFT: Foot, Feet, Fully TemperedFTG: Footing, FittingFURN: Furnish, Furniture FURR: Furring FUT: FutureG: GasGA: GaugeGAL: Gallon GALV: GalvanizedGC: General Contractor GEN: GeneralGFCI: Ground Fault Circuit InterruptedGFI: Ground Fault InterruptedGFRC: Glass Fiber Reinforced ConcreteGI: Galvanized IronGKT: GasketGL: GlassGLZ: GlazeGMU: Glazed Masonry UnitGND: GroundGOVT: GovernmentGP: Galvanized PipeGR: GradeGRAN: GraniteGRTG: Grating GT: GroutGV: Galvanized GVL: GravelGYP: Gypsum GYP BD: Gypsum BoardHB: Hose Bib HBD: HardboardHC: Hollow CoreHD: Heavy DutyHDR: HeaderHDPE: High Density PolyethyleneHDW: Hardware HDWD: HardwoodHGR: Hanger HGT: HeightHK: Hook or HooksHM: Hollow MetalHMP: Hollow Metal, PaintedHOR: HorizontalHR: HourHRS: Hot Rolled Steel, HoursHT: HeightHTR: HeaterHV: High Voltage HVAC: Heating, Ventilating & Air ConditioningHW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water SupplyHYD: HydraulicI: Iron ID: Inside DiameterIN: Inch INC: Incandescent INCL: Incline, IncludeINCR: IncreaseINFO: Information INSP: Inspect INSTL: Install INSUL: InsulationINT: Interior INV: Invert IP: Iron PipeJ: Joist JB: Junction BoxJC: Janitor's ClosetJF: Joint FillerK: KickplateKIT: KitchenKS: Kitchen SinkKW: KilowattL: Left, LengthLAD: Ladder LAM: Laminate, LaminatedLB: Pound (weight), Lag BoltLBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen ClosetLCM: Lead Coated Metal LD: Leader DrainLH: Left HandLIB: Library LINO: LinoleumLIQ: LiquidLKR: LockerLL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: LocationsLR: Living RoomLS: Loud Speaker LT: LightLTG: LightingLTL: Lintel LV: Low Voltage LVR: Louver LW: Light WeightLWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: MarbleMAS: MasonryMATL: MaterialMAX: Maximum MB: Mail Box MC: Medicine Cabinet MECH: Mechanical MED: Medium MEMB: Membrane MET: Metal MEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, Manufacturing MH: Manhole MIKE: Microphone MIN: Minimum MIR: Mirror MISC: Miscellaneous MLDG: Molding MO: Masonry Opening MOD: Module MONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, Mounted MTL: Material, Metal MTR: Motor MULL: Mullion MWK: Millwork N: North NATL: Natural NEC: National Electrical Code NEUT: Neutral NI: Nickel NIC: Not In Contract NO: Number NOM: Nominal NR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to Out OA: Outside Air, Overall OC: On Center OD: Outside Diameter OF: Outside Face OFF: Office OH: Overhead OHD: Overhead Door OI: Ornamental Iron OPNG: Opening OPP: Opposite OPP H: Opposite Hand ORN: Ornamental OUT: Outlet OVFL: Overflow OZ: Ounce P: Paint P. LAM: Plastic Laminate P SL: Pipe Sleeve PAR: Parallel PARTN: Partition PB: Panic Bar PBD: Particle Board PC: Precast Concrete PCF: Pounds per cubic foot PD: Pump Discharge, Plaza Drain PE: Professional Engineer PED: Pedestal, Pedestrian PERF: Perforate PERIM: Perimeter PERP: Perpendicular PFN: Prefinished PH: Phase, Phone PKG: Parking PKWY: Parkway PL: Property Line PLAS: Plastic PLAS LAM: Plastic Laminate PLF: Pounds Per Lineal Foot PLMBG: Plumbing PLTF: Platform PLWD: Plywood PNL: Panel PNT: Paint POL: Polish, Polished PORC: Porcelain PORT: Portable POT W: Potable Water PP: Precast Panel PR: Pair PRC: Precast PREFAB: Prefabricated PRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: Premolded PROT: Protection, Protective PRSTR: Prestressed PRTN: Partition PS: Plumbing Stack PSC: Prestressed Concrete PSF: Pounds per square foot PSI: Pounds per square inch PT: Point PTC: Post-Tensioned Concrete PTD: Paper Towel Dispenser PTD/R: Combination Paper Towel Dispenser/Receptacle PV: Paving PVG: Paving PVMT: Pavement PVT: Private PWR: Power QUAL: Quality QT: Quarry Tile, Quart QTR: Quarter QTY: Quantity R: Radius R & S: Rod and Sealant RA: Return Air, Registered Architect RAD: Radiator RB: Rubber RBT: Rabbet RCP: Reflected Ceiling Plan RD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year A: Area, Acre; Alcove; Compressed Air LineAB: Anchor BoltABV: Above AC: Air Conditioning, Alternating CurrentACC: Access ACF: Architectural Concrete FinishACR: AcrylicACST: AcousticACT: ActualAD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992ADD: Addendum; Addition ADDL: AdditionalADH: AdhesiveADJ: Adjust, Adjustable, Adjacent AF: Above the FloorAFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; AltitudeALUM: AluminumAMB: AmbientAMT: AmountANCH: Anchor, AnchorageANOD: Anodized AP: Access PanelAPPROX: ApproximateAPRVD: Approved APT: ApartmentARCH: Architect, ArchitecturalAS: Acoustic SealantASC: Above Suspended CeilingASPH: AsphaltASSEM: AssembleASSY: Assembly ASTM: American Society for Testing and MaterialsATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; AtmosphericAUTH: Authorized AUTO: Automatic AVG: AverageB: BathroomB TO B: Back to BackB & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, BallastBC: Broom ClosetBDY: BoundaryBEL: BelowBETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: BuildingBLK: Block BLKG: BlockingBLT-IN: Built-In BM: Beam, Bench MarkBN: BullnoseBNT: Bent BOT: BottomBP: Base Plate BPL: Bearing PlateBR: BedroomBRDG: Bridging BRG: BearingBRK: BrickBRKT: Bracket BRS: BrassBRZ: BronzeBS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up RoofBW: Both WaysC: Curb, Clock Outlet C/C: Center to CenterCAB: CabinetCAP: Capacity CAR: CarpetCAV: CavityCCW: Counter Clockwise CCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCFL: CounterflashingCFS: Cold Formed SteelCG: Corner GuardCH: Coat HookCHR: Chilled Water Return CHAM: ChamferCHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-PlaceCIR: Circle, CircularCIRC: CircumferenceCITG: Clear Insulating Tempered GlassCJ: Control JointCK: Caulking CL: Centerline, Clearance, Closure, Class CLG: CeilingCLL: Contract Limit Line CLO: ClosetCLR: ClearCLR OPG: Clear OpeningCMP: Corrugated Metal PipeCMU: Concrete Masonry UnitCND: ConduitCNTR: CounterCOAX: CoaxialC.O.: Cased OpeningCO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: ColumnCOM: CommonCON: ConstructionCONC: Concrete CONN: Connection CONT: Continuous, Continue, ControlCOP: CopperCOR: Corner CORR: Corridor, CorrugateCR: Curtain RodCRPT: CarpetCRS: Course, Cold Rolled SteelCS: Cast Stone CSG: Casing CSK: CountersinkCSMT: Casement CT: Ceramic Tile CTD: Coated CTR: CenterCW: Clockwise, Cold WaterCWR: Condensate Waste ReturnCWS: Condensate Waste SupplyCY: Cubic Yard CYL: Cylinder CYL L: Cylinder LockDA: Double ActingDB: Decibel DBL: DoubleDC: Direct CurrentDD: Driveway Drain, Deck DrainDEG: DegreeDEGF: Degree Farenheit DEMO: DemolitionDEPT: DepartmentDF: Drinking FountainDH: Double HungDIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: DimensionDISL: DisposalDIV: DivisionDL: Dead LoadDMT: DemountableDN: Down DO: Door OpeningDP: Dampproofing DPR: Damper DR: Door, Dining Room DS: DownspoutDSP: Dry Standpipe DT: Drain TileDTL: Detail DVTL: DovetailDWG: DrawingDWGS: DrawingsDWR: DrawerE: EastE TO E: End to EndEA: EachEB: Expansion BoltEC: Exposed Construction ECP: Exposed Construction Painted EE: Each EndEF: Each FaceEG: Edge Grain EIFS: Exterior Insulation and Finish SystemEJ: Expansion JointELEC: ElectricalELEV: Elevator, Elevation EMER: EmergencyENAM: Enamel ENCL: EnclosureENG: Engineer ENT: EntranceEPDM: Ethylene Propylene Diene MonomerEQ: Equal EQUIP: EquipmentERP: Emergency Receptacle PanelEST: EstimateEW: Each WayEX: ExitEXC: ExcavateEXEC: ExecutiveEXH: ExhaustEXH AIR: Exhaust AirEXIST: Existing EXP: Expansion, Exposed EXT: ExteriorF: Degrees FahrenheitF TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: FabricateFACP: Fire Alarm Control PanelFAG: Fire Alarm Gong FAST: Fastener, FastenFBD: FiberboardFBRK: Fire Brick FD: Floor drainFDC: Fire Department ConnectionFDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher CabinetFF: Finished Floor, Factory FinishFFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor Line FGL: FiberglassFGR: Fiberglass reinforced FH: Fire HoseFHC: Fire Hose CabinetFHWS: Flat Head Wood ScrewFHY: Fire HydrantFIN: Finish, finished FIX: FixtureFLG: FlashingFLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin DispenserFO: Finished OpeningFOC: Face of ConcreteFOF: Face of FinishFOS: Face of StudsFP: Fireproof FPL: FireplaceFR: Front, Fire Riser FRM: FrameFRT: Fire RetardantFS: Floor SinkFT: Foot, Feet, Fully TemperedFTG: Footing, FittingFURN: Furnish, Furniture FURR: Furring FUT: FutureG: GasGA: GaugeGAL: Gallon GALV: GalvanizedGC: General Contractor GEN: GeneralGFCI: Ground Fault Circuit InterruptedGFI: Ground Fault InterruptedGFRC: Glass Fiber Reinforced ConcreteGI: Galvanized IronGKT: GasketGL: GlassGLZ: GlazeGMU: Glazed Masonry UnitGND: GroundGOVT: GovernmentGP: Galvanized PipeGR: GradeGRAN: GraniteGRTG: Grating GT: GroutGV: Galvanized GVL: GravelGYP: Gypsum GYP BD: Gypsum BoardHB: Hose Bib HBD: HardboardHC: Hollow CoreHD: Heavy DutyHDR: HeaderHDPE: High Density PolyethyleneHDW: Hardware HDWD: HardwoodHGR: Hanger HGT: HeightHK: Hook or HooksHM: Hollow MetalHMP: Hollow Metal, PaintedHOR: HorizontalHR: HourHRS: Hot Rolled Steel, HoursHT: HeightHTR: HeaterHV: High Voltage HVAC: Heating, Ventilating & Air ConditioningHW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water SupplyHYD: HydraulicI: Iron ID: Inside DiameterIN: Inch INC: Incandescent INCL: Incline, IncludeINCR: IncreaseINFO: Information INSP: Inspect INSTL: Install INSUL: InsulationINT: Interior INV: Invert IP: Iron PipeJ: Joist JB: Junction BoxJC: Janitor's ClosetJF: Joint FillerK: KickplateKIT: KitchenKS: Kitchen SinkKW: KilowattL: Left, LengthLAD: Ladder LAM: Laminate, LaminatedLB: Pound (weight), Lag BoltLBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen ClosetLCM: Lead Coated Metal LD: Leader DrainLH: Left HandLIB: Library LINO: LinoleumLIQ: LiquidLKR: LockerLL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: LocationsLR: Living RoomLS: Loud Speaker LT: LightLTG: LightingLTL: Lintel LV: Low Voltage LVR: Louver LW: Light WeightLWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: MarbleMAS: MasonryMATL: MaterialMAX: Maximum MB: Mail BoxMC: Medicine Cabinet MECH: MechanicalMED: MediumMEMB: Membrane MET: MetalMEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, ManufacturingMH: ManholeMIKE: MicrophoneMIN: MinimumMIR: Mirror MISC: MiscellaneousMLDG: Molding MO: Masonry Opening MOD: ModuleMONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, MountedMTL: Material, MetalMTR: MotorMULL: MullionMWK: MillworkN: NorthNATL: Natural NEC: National Electrical Code NEUT: NeutralNI: Nickel NIC: Not In ContractNO: Number NOM: NominalNR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to OutOA: Outside Air, OverallOC: On CenterOD: Outside DiameterOF: Outside FaceOFF: OfficeOH: OverheadOHD: Overhead DoorOI: Ornamental IronOPNG: OpeningOPP: OppositeOPP H: Opposite HandORN: OrnamentalOUT: OutletOVFL: OverflowOZ: OunceP: Paint P. LAM: Plastic LaminateP SL: Pipe Sleeve PAR: Parallel PARTN: PartitionPB: Panic BarPBD: Particle Board PC: Precast ConcretePCF: Pounds per cubic footPD: Pump Discharge, Plaza DrainPE: Professional EngineerPED: Pedestal, Pedestrian PERF: PerforatePERIM: Perimeter PERP: PerpendicularPFN: PrefinishedPH: Phase, PhonePKG: ParkingPKWY: ParkwayPL: Property LinePLAS: PlasticPLAS LAM: Plastic Laminate PLF: Pounds Per Lineal FootPLMBG: PlumbingPLTF: PlatformPLWD: Plywood PNL: PanelPNT: Paint POL: Polish, PolishedPORC: PorcelainPORT: Portable POT W: Potable WaterPP: Precast PanelPR: Pair PRC: PrecastPREFAB: PrefabricatedPRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: PremoldedPROT: Protection, ProtectivePRSTR: PrestressedPRTN: PartitionPS: Plumbing StackPSC: Prestressed ConcretePSF: Pounds per square foot PSI: Pounds per square inchPT: PointPTC: Post-Tensioned ConcretePTD: Paper Towel DispenserPTD/R: Combination Paper Towel Dispenser/ReceptaclePV: PavingPVG: PavingPVMT: PavementPVT: PrivatePWR: PowerQUAL: QualityQT: Quarry Tile, QuartQTR: QuarterQTY: QuantityR: RadiusR & S: Rod and SealantRA: Return Air, Registered ArchitectRAD: RadiatorRB: Rubber RBT: RabbetRCP: Reflected Ceiling PlanRD: Roof Drain, Round REBAR: Reinforcing Bar RECP: Receptacle REF: Refer, Reference, Refrigerator REFL: Reflected, Reflector REG: Regular REINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: Resilient RET: Return, Retaining REV: Reverse, Revise, Revision RF: Roof RFG: Roofing RGTR: Register RGH: Rough RH: Right Hand RHR: Right Hand Reverse RM: Room RMV: Remove, Removable RO: Rough Opening ROW: Right of Way RPM: Revolutions Per Minute RT: Rubber Tile, Right RTR/RR Rubber Tread/Rubber Riser RVS: Reverse Side RVT: Rivet RWC: Rain Water Conductor RWL: Rain Water Leader S: South, Sealant, Supply S&S: Stained & Sealed S&V: Stain & Varnish SACT: Suspended Acoustical Tile SALV: Salvage SAN: Sanitary SC: Solid Core SCD: Seat Cover Dispenser SCH: Schedule SCR: Screen SCUP: Scupper SCWD: Solid Core Wood SD: Soap Dispenser SE: Structural Engineer SEC: Second, Secondary, Security System SECT: Section SEL: Select SERV: Service SF: Square Foot SFGL: Safety Glass SGS: Silicone Glazing Sealant SH: Shelf SHT: Sheet SHTHG: Sheathing SHWR: Shower SIG: Signal SIM: Similar SJS: Silicone Joint Sealant SK: Sink SKL: Skylight SLV: Sleeve SND: Sanitary Napkin Dispenser SP: Standpipe, Soundproof SPC: Spacer SPECS: Specifications SPK: Speaker SPL: Special SPLR: Sprinkler SPM: Sprinkler Main SPP: Skim Coat Plaster Painted SQ: Square SS: Stainless Steel, Soil Stack SSGS: Silicone Structural Glazing Sealant SSK: Service Sink ST: Storm Water STA: Station STC: Sound Transmission Class STD: Standard STG: Storage, Seating STK: Stack STL: Steel STOR: Storage STRUC: Structural STWY: Stairway SUPP: Supplementary, Supplement SUPT: Superintendent SUR: Surface SUSP: Suspended, Suspend SV: Safety Relief Valve SW: Switch SWBD: Switchboard SWGR: Switchgear SY: Square Yard SYM: Symmetrical SYN: Synthetic SYS: System T: Tread T/: Top of T&B: Top and Bottom T&G: Tongue & Groove TAN: Tangent TB: Towel Bar TC: Top of Curb, Terracotta TD: Trench Drain TEL: Telephone TEMP: Temporary, Tempered, Temperature TEN: Tenant TERM: Terminal TH: Thermostat THK: Thick, Thickness THR: Threshold THRM: Thermal THRU: Through TLT: Toilet TOL: Tolerance TP: Top of Pavement TPD: Toilet paper Dispenser TPH: Toilet Paper Holder TPTN: Toilet Partition TRANS: Transformer, Translucent TRAV: Travertine TRD: Tread TSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year A: Area, Acre; Alcove; Compressed Air LineAB: Anchor BoltABV: Above AC: Air Conditioning, Alternating CurrentACC: Access ACF: Architectural Concrete FinishACR: AcrylicACST: AcousticACT: ActualAD: Access Door, Area Drain ADA: Americans with Disabilities Act of 1992ADD: Addendum; Addition ADDL: AdditionalADH: AdhesiveADJ: Adjust, Adjustable, Adjacent AF: Above the FloorAFF: Above Finished Floor AIA: American Institute of Architects ALM: Alarm ALT: Alternate, Alteration; AltitudeALUM: AluminumAMB: AmbientAMT: AmountANCH: Anchor, AnchorageANOD: Anodized AP: Access PanelAPPROX: ApproximateAPRVD: Approved APT: ApartmentARCH: Architect, ArchitecturalAS: Acoustic SealantASC: Above Suspended CeilingASPH: AsphaltASSEM: AssembleASSY: Assembly ASTM: American Society for Testing and MaterialsATC: Acoustical Tile Ceiling ATTEN: Attenuation, Attention ATM: Automatic Teller Machine; AtmosphericAUTH: Authorized AUTO: Automatic AVG: AverageB: BathroomB TO B: Back to BackB & B: Balled and Burlapped B/: Bottom (of) BAL: Balance, BallastBC: Broom ClosetBDY: BoundaryBEL: BelowBETW: Between BEV: Bevel BHD: Bulkhead BIT: Bituminous BJF: Bituminous Joint Filler BL: Building Line BLDG: BuildingBLK: Block BLKG: BlockingBLT-IN: Built-In BM: Beam, Bench MarkBN: BullnoseBNT: Bent BOT: BottomBP: Base Plate BPL: Bearing PlateBR: BedroomBRDG: Bridging BRG: BearingBRK: BrickBRKT: Bracket BRS: BrassBRZ: BronzeBS: Both Sides BSMT: Basement BT: Bathtub, Bolt BUR: Built-up RoofBW: Both WaysC: Curb, Clock Outlet C/C: Center to CenterCAB: CabinetCAP: Capacity CAR: CarpetCAV: CavityCCW: Counter Clockwise CCTV: Closed Circuit TVCEM: CementCER: CeramicCF: Cubic FeetCFL: CounterflashingCFS: Cold Formed SteelCG: Corner GuardCH: Coat HookCHR: Chilled Water Return CHAM: ChamferCHAN: Channel CHS: Chilled Water Supply CI: Cast Iron CIP: Cast-in-PlaceCIR: Circle, CircularCIRC: CircumferenceCITG: Clear Insulating Tempered GlassCJ: Control JointCK: Caulking CL: Centerline, Clearance, Closure, Class CLG: CeilingCLL: Contract Limit Line CLO: ClosetCLR: ClearCLR OPG: Clear OpeningCMP: Corrugated Metal PipeCMU: Concrete Masonry UnitCND: ConduitCNTR: CounterCOAX: CoaxialC.O.: Cased OpeningCO: Company, Cleanout, Cased Opening, Cut Out COD: Cleanout Door COL: ColumnCOM: CommonCON: ConstructionCONC: Concrete CONN: Connection CONT: Continuous, Continue, ControlCOP: CopperCOR: Corner CORR: Corridor, CorrugateCR: Curtain RodCRPT: CarpetCRS: Course, Cold Rolled SteelCS: Cast Stone CSG: Casing CSK: CountersinkCSMT: Casement CT: Ceramic Tile CTD: Coated CTR: CenterCW: Clockwise, Cold WaterCWR: Condensate Waste ReturnCWS: Condensate Waste SupplyCY: Cubic Yard CYL: Cylinder CYL L: Cylinder LockDA: Double ActingDB: Decibel DBL: DoubleDC: Direct CurrentDD: Driveway Drain, Deck DrainDEG: DegreeDEGF: Degree Farenheit DEMO: DemolitionDEPT: DepartmentDF: Drinking FountainDH: Double HungDIAG: Diagonal DIA: Diameter DIFF: Diffuser DIM: DimensionDISL: DisposalDIV: DivisionDL: Dead LoadDMT: DemountableDN: Down DO: Door OpeningDP: Dampproofing DPR: Damper DR: Door, Dining Room DS: DownspoutDSP: Dry Standpipe DT: Drain TileDTL: Detail DVTL: DovetailDWG: DrawingDWGS: DrawingsDWR: DrawerE: EastE TO E: End to EndEA: EachEB: Expansion BoltEC: Exposed Construction ECP: Exposed Construction Painted EE: Each EndEF: Each FaceEG: Edge Grain EIFS: Exterior Insulation and Finish SystemEJ: Expansion JointELEC: ElectricalELEV: Elevator, Elevation EMER: EmergencyENAM: Enamel ENCL: EnclosureENG: Engineer ENT: EntranceEPDM: Ethylene Propylene Diene MonomerEQ: Equal EQUIP: EquipmentERP: Emergency Receptacle PanelEST: EstimateEW: Each WayEX: ExitEXC: ExcavateEXEC: ExecutiveEXH: ExhaustEXH AIR: Exhaust AirEXIST: Existing EXP: Expansion, Exposed EXT: ExteriorF: Degrees FahrenheitF TO F: Face to Face FA: Fire Alarm, Fresh Air FAB: FabricateFACP: Fire Alarm Control PanelFAG: Fire Alarm Gong FAST: Fastener, FastenFBD: FiberboardFBRK: Fire Brick FD: Floor drainFDC: Fire Department ConnectionFDN: Foundation FE: Fire Extinguisher FEC: Fire Extinguisher CabinetFF: Finished Floor, Factory FinishFFE: Finished Floor Elevation FF&E: Fixtures, Furnishings & EquipmentFFL: Finished Floor Line FGL: FiberglassFGR: Fiberglass reinforced FH: Fire HoseFHC: Fire Hose CabinetFHWS: Flat Head Wood ScrewFHY: Fire HydrantFIN: Finish, finished FIX: FixtureFLG: FlashingFLR: Floor FLUOR: Fluorescent FLX: Flexible FND: Feminine Napkin DispenserFO: Finished OpeningFOC: Face of ConcreteFOF: Face of FinishFOS: Face of StudsFP: Fireproof FPL: FireplaceFR: Front, Fire Riser FRM: FrameFRT: Fire RetardantFS: Floor SinkFT: Foot, Feet, Fully TemperedFTG: Footing, FittingFURN: Furnish, Furniture FURR: Furring FUT: FutureG: GasGA: GaugeGAL: Gallon GALV: GalvanizedGC: General Contractor GEN: GeneralGFCI: Ground Fault Circuit InterruptedGFI: Ground Fault InterruptedGFRC: Glass Fiber Reinforced ConcreteGI: Galvanized IronGKT: GasketGL: GlassGLZ: GlazeGMU: Glazed Masonry UnitGND: GroundGOVT: GovernmentGP: Galvanized PipeGR: GradeGRAN: GraniteGRTG: Grating GT: GroutGV: Galvanized GVL: GravelGYP: Gypsum GYP BD: Gypsum BoardHB: Hose Bib HBD: HardboardHC: Hollow CoreHD: Heavy DutyHDR: HeaderHDPE: High Density PolyethyleneHDW: Hardware HDWD: HardwoodHGR: Hanger HGT: HeightHK: Hook or HooksHM: Hollow MetalHMP: Hollow Metal, PaintedHOR: HorizontalHR: HourHRS: Hot Rolled Steel, HoursHT: HeightHTR: HeaterHV: High Voltage HVAC: Heating, Ventilating & Air ConditioningHW: Hot Water HWR: Hot Water Recirculating Return HWS: Hot Water SupplyHYD: HydraulicI: Iron ID: Inside DiameterIN: Inch INC: Incandescent INCL: Incline, IncludeINCR: IncreaseINFO: Information INSP: Inspect INSTL: Install INSUL: InsulationINT: Interior INV: Invert IP: Iron PipeJ: Joist JB: Junction BoxJC: Janitor's ClosetJF: Joint FillerK: KickplateKIT: KitchenKS: Kitchen SinkKW: KilowattL: Left, LengthLAD: Ladder LAM: Laminate, LaminatedLB: Pound (weight), Lag BoltLBL: Label LBR: Lumber LCD: Liquid Crystal Diode LCL: Linen ClosetLCM: Lead Coated Metal LD: Leader DrainLH: Left HandLIB: Library LINO: LinoleumLIQ: LiquidLKR: LockerLL: Live Load LMS: Limestone LN: Length LNDG: Landing LOC: Locate LOCS: LocationsLR: Living RoomLS: Loud Speaker LT: LightLTG: LightingLTL: Lintel LV: Low Voltage LVR: Louver LW: Light WeightLWC: Light Weight Concrete MACH: Machine MAINT: Maintenance MARB: MarbleMAS: MasonryMATL: MaterialMAX: Maximum MB: Mail BoxMC: Medicine Cabinet MECH: MechanicalMED: MediumMEMB: Membrane MET: MetalMEZZ: Mezzanine MFD: Manufactured, Metal Floor Deck MFG: Manufacturer, ManufacturingMH: ManholeMIKE: MicrophoneMIN: MinimumMIR: Mirror MISC: MiscellaneousMLDG: Molding MO: Masonry Opening MOD: ModuleMONO: Monolithic MOV: Movable MRD: Metal Roof Deck MT: Mount, MountedMTL: Material, MetalMTR: MotorMULL: MullionMWK: MillworkN: NorthNATL: Natural NEC: National Electrical Code NEUT: NeutralNI: Nickel NIC: Not In ContractNO: Number NOM: NominalNR: Noise Reduction NRC: Noise Reduction Coefficient NS: Near Side NTS: Not To Scale O TO O: Out to OutOA: Outside Air, OverallOC: On CenterOD: Outside DiameterOF: Outside FaceOFF: OfficeOH: OverheadOHD: Overhead DoorOI: Ornamental IronOPNG: OpeningOPP: OppositeOPP H: Opposite HandORN: OrnamentalOUT: OutletOVFL: OverflowOZ: OunceP: Paint P. LAM: Plastic LaminateP SL: Pipe Sleeve PAR: Parallel PARTN: PartitionPB: Panic BarPBD: Particle Board PC: Precast ConcretePCF: Pounds per cubic footPD: Pump Discharge, Plaza DrainPE: Professional EngineerPED: Pedestal, Pedestrian PERF: PerforatePERIM: Perimeter PERP: PerpendicularPFN: PrefinishedPH: Phase, PhonePKG: ParkingPKWY: ParkwayPL: Property LinePLAS: PlasticPLAS LAM: Plastic Laminate PLF: Pounds Per Lineal FootPLMBG: PlumbingPLTF: PlatformPLWD: Plywood PNL: PanelPNT: Paint POL: Polish, PolishedPORC: PorcelainPORT: Portable POT W: Potable WaterPP: Precast PanelPR: Pair PRC: PrecastPREFAB: PrefabricatedPRES: Pressure PRFMD: Preformed PRI: Primary PRMLD: PremoldedPROT: Protection, ProtectivePRSTR: PrestressedPRTN: PartitionPS: Plumbing StackPSC: Prestressed ConcretePSF: Pounds per square foot PSI: Pounds per square inchPT: PointPTC: Post-Tensioned ConcretePTD: Paper Towel DispenserPTD/R: Combination Paper Towel Dispenser/ReceptaclePV: PavingPVG: PavingPVMT: PavementPVT: PrivatePWR: PowerQUAL: QualityQT: Quarry Tile, QuartQTR: QuarterQTY: QuantityR: RadiusR & S: Rod and SealantRA: Return Air, Registered ArchitectRAD: RadiatorRB: Rubber RBT: RabbetRCP: Reflected Ceiling PlanRD: Roof Drain, Round REBAR: Reinforcing BarRECP: Receptacle REF: Refer, Reference, RefrigeratorREFL: Reflected, ReflectorREG: RegularREINF: Reinforcement, or Reinforce REQ: Require, Required RESIL: ResilientRET: Return, RetainingREV: Reverse, Revise, RevisionRF: RoofRFG: RoofingRGTR: RegisterRGH: RoughRH: Right Hand RHR: Right Hand ReverseRM: RoomRMV: Remove, RemovableRO: Rough Opening ROW: Right of WayRPM: Revolutions Per MinuteRT: Rubber Tile, RightRTR/RR Rubber Tread/Rubber RiserRVS: Reverse SideRVT: RivetRWC: Rain Water ConductorRWL: Rain Water LeaderS: South, Sealant, Supply S&S: Stained & SealedS&V: Stain & VarnishSACT: Suspended Acoustical TileSALV: SalvageSAN: SanitarySC: Solid Core SCD: Seat Cover Dispenser SCH: ScheduleSCR: ScreenSCUP: ScupperSCWD: Solid Core WoodSD: Soap DispenserSE: Structural EngineerSEC: Second, Secondary, Security SystemSECT: SectionSEL: SelectSERV: ServiceSF: Square FootSFGL: Safety Glass SGS: Silicone Glazing SealantSH: ShelfSHT: SheetSHTHG: SheathingSHWR: ShowerSIG: SignalSIM: SimilarSJS: Silicone Joint SealantSK: SinkSKL: SkylightSLV: SleeveSND: Sanitary Napkin DispenserSP: Standpipe, SoundproofSPC: SpacerSPECS: SpecificationsSPK: SpeakerSPL: SpecialSPLR: SprinklerSPM: Sprinkler MainSPP: Skim Coat Plaster PaintedSQ: SquareSS: Stainless Steel, Soil StackSSGS: Silicone Structural Glazing SealantSSK: Service SinkST: Storm WaterSTA: StationSTC: Sound Transmission ClassSTD: StandardSTG: Storage, SeatingSTK: StackSTL: SteelSTOR: StorageSTRUC: StructuralSTWY: StairwaySUPP: Supplementary, SupplementSUPT: SuperintendentSUR: SurfaceSUSP: Suspended, SuspendSV: Safety Relief ValveSW: SwitchSWBD: SwitchboardSWGR: SwitchgearSY: Square YardSYM: SymmetricalSYN: SyntheticSYS: SystemT: TreadT/: Top ofT&B: Top and BottomT&G: Tongue & GrooveTAN: TangentTB: Towel Bar TC: Top of Curb, TerracottaTD: Trench DrainTEL: TelephoneTEMP: Temporary, Tempered, Temperature TEN: TenantTERM: Terminal TH: ThermostatTHK: Thick, ThicknessTHR: ThresholdTHRM: ThermalTHRU: ThroughTLT: ToiletTOL: ToleranceTP: Top of Pavement TPD: Toilet paper DispenserTPH: Toilet Paper HolderTPTN: Toilet PartitionTRANS: Transformer, Translucent TRAV: Travertine TRD: TreadTSL: Top of Slab TST: Top of Steel TT: Traffic Topping TTC: Telephone Terminal Closet TW: Top of Wall TYP: Typical TZ: Terrazzo UH: Unit Heater UL: Underwriters' Laboratories UNEXC: Unexcavated UNFIN: Unfinished UNO: Unless Noted Otherwise UR: Urinal USG: United States Gypsum Company UT: Utility V: Volt VAR: Varies VB: Vapor Barrier VCT: Vinyl Composition Tile VENT: Ventilate, Ventilator VERT: Vertical VEST: Vestibule VF: Vinyl Fabric VIF: Verify In the Field VIN: Vinyl VNR: Veneer VOL: Volume VP: Vapor Proof, Vent Pipe VR: Vapor Retarder VS: Vent Stack VT: Vinyl Tile VTR: Vent Through Roof VWC: Vinyl Wall Covering W: West, Width, Wide, Watt, Waste, Water, Water W/: With W/O: Without WAINS: Wainscot WB: Wood Base WC: Watercloset WD: Wood WDP: Wood, Painted WDSS: Wood, Stained & Sealed WF: Wide Flange (structural steel) WGL: Wire-Glass WH: Water Heater, Wall Hung, Wall Hydrant WI: Wrought Iron WIN: Window WM: Wire Mesh, Water Meter WP: Waterproof, Weatherproof WPR: Waterproofing WPT: Working Point WR: Water Resistant, Water Repellant WS: Weatherstripping, Water Stop WT: Weight, Water Table, Watertight WVNR: Wood Veneer WWF: Welded Wire Fabric X HVY: Extra Heavy X STR: Extra Strong YD: Yard YR: Year GENERAL NOTES: 1. Nothing set forth in these drawings shall release any contractor from his responsibility to provide appropriate quantities, field measurements, dimensional stability, installation, anchorage, and coordination with other trades; or release him from his responsibility t o identify and resolve deviations from the requirements of the contract documents, or free him of his responsibility to alert designer to errors or omission. 2. Contractor shall utilize these drawings in conjunction with the specifications to determine the full scope, intent and requirements of the project. Specifications and drawings are intended to be complementary, not mutually exclusive. Work shown on the drawings but not listed in the specifications, and work described in the specifications but not shown on the drawings shall be interpreted as though work were fully described in both places. The higher quantity, higher quality, more labor intensive and overall more stringent and more costly requirement shall apply unless otherwise clarified in writing prior to bid. 3. Each contractor shall verify in the field all existing applicable conditions and dimensions shown on the drawings and as pertinent to the intent of these drawings. Any discrepancy discovered shall be brought to the attention of the designer prior to the commencement of any work affected by, or related to, such discrepancy. Each contractor shall be responsible for all costs associated with, or caused by his failure to comply with this requirement. 4. Each contractor shall review all portions of his work, before starting the work, to verify that the work will not prohibit completion of the project as intended in these construction documents. All questions shall be referred to the designer for resolution. 5. Each contractor shall field verify all existing applicable conditions and dimensions shown on the drawings. As pertains to the intent of these drawings, contractor shall bring to the attention of the architect and designer any discrepancies discovered prior to the commencement of any work affected by or related to such discrepancy. Each contractor shall be responsible for all costs associated with or caused by that contractor’s failure to comply with this requirement. 6. All dims. To ext. Walls are to outside face of sheathing. Structural drawings are to outside face of stud. 7. All dims. To Interior Partition walls are to face of framing. 8. Top of first floor = 0'-0" = 834.50' (not including, floor finish thickness) 9. All work shown in these drawings and in the specifications shall be base bid unless noted to be by alternate bid. 10. Refer to sheet a002 for wall types. 11. Refer to sheet a601 for door types. All new doors to be installed with hinge 4" from wall (minimum). 12. Paint all hollow metal doors and frames exposed steel handrails and guardrails. 13. Caulk interior and exterior perimeters of all hollow metal and aluminum door and window frames. 14. Verify undercut requirements of doors where carpet or other flooring is to be installed. 15. Maximum spacing between gypsum board control joints (CJ) shall be 30'-0". The maximum distance from a corner to a joint shall be 24'-0". Provide control joints between all interior load bearing walls and non-load bearing walls, at all abrupt changes in wall height, at all changes of wall thickness, at pilasters and columns. Verify final joint locations with a/ebefore construction. 16. A minimum clear area of 18" is required to the side of each door strike jamb on the pull side for doors on an accessible route. 17. All framed walls shall extend to deck above and be provided with fire stop sealant unless noted otherwise. 18. Do not scale drawings, contact architect if specific dimension is needed. 19. Provide concealed fire rated wood blocking or metal framing supports as required for all surface mounted items. 20. All new fire extinguisher cabinets to be finished to match adjacent wall finish and installed according to code. Life Safety Contractor to verify placement and quantity of fire extinguishers throughout the space. If additional fire extinguisher locations are needed, a plan must be submitted to the designer for review of aesthetic purposes only. 21. Apply sealant at all plumbing fixtures, at juncture with wall, and at all countertops and backsplash junctures. 22. Top layer of sound isolation system and new floor finishes as scheduled. See details. 23. Coordinate clearance and access for mechanical units with mechanical plans. Contact architect to coordinate issues. 24. Cement board to be used in all sections and portions of wall and ceilings w/ tile finish. See finish plans and reference ceiling plans to coordinate finish location. 25. Ant and all penetrations shall receive caulking to seal any type of energy loss. 26. The Contractor to verify and coordinate all applicable dimensions of fixtures and equipment supplied and /or installed by others. 27. The use of the words “Provide” or “Provided” in connection with any item specified is intended to mean, unless otherwise noted, that such shall be furnished, installes and connected where so required. 28. Upon completion of project, obtain all final inspections as required by local jurisdictions and furnish owner with evidence of all such Inspections and Certificates Of Occupancy. 29. These Construction Notes and/ or Drawings are supplied to illustrate the design and general type of construction desired and are intended to imply the finest quality of construction material and workmanship throughout. 30. All means of Egress and Fire Protection shall be maintained at all times. Any shut down of Life Safety or Building Systems shall be approved and coordinated in advance with the Owner and Local Building Department. 31. The General Contractor is responsible for providing temporary bracing and/ or shoring intil the permanent bracing is in place. 32. All Contractors are required to coordinate their work with all disciplines to avoid conflicts. See Mechanical, Electrical and Plumbing drawings for additional information regarding size and quantity of openings, slab requirements and lintels. 33. These drawings are not to be separated. 34. Contractor shall provide wood blocking in walls for mounting cabinets. 35. Provide one 2A:10B:C Fire Extinguisher mounted in the kitchen sink base cabinet of each Dwelling unit. 36. All new doors to be installed with hinges side 4” minimum from wall, in framed wall condition. See plan for C.I.P. and C.M.U. walls. 37. Provide window blinds. Reference A/522 for specification. 38. Provide blocking in all bathrooms as required for future grab bars. See details om A/521 for locations.