Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A002 Master Wall Legend
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032800 West Monon Green BlvdPEDCOR DESIGN GROUP LLC A002 Master Wall Legend THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS #### LGA #### SCALE: NTS PLAN NORTH KEY PLAN Bldg I Revision ID Issue Date Issue Name A B C D 1 1 2 2 3 3 4 4 A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Windsor - Building I/Building I WindsorWALL TYPE LEGEND Wall Composite Wall C8 -8" CONC;NO SKIN Wall GB8 -8" GLASS BLOCK, NO SKIN Wall M6 -6" CMU, NO SKIN Wall M8 -8" CMU, NO SKIN Wall S5Hi 2HR-3 CH STD;GYP,1 SIDE, LINER 1 SIDE 6+INSULATION Wall S6A-6 MTL STD;GYP,1 SIDE Wall S6Bi-6 MTL STD;GYP,2 SIDES+INSULATION Wall S6E-6 MTL STD; PLY 1 SIDE, EXT. SHT OPP Wall S8D-8 MTL STD; 5/8", 5/8" EXT. SHEATHING 2 SIDES Wall S8Di-8 MTL STD; 5/8", 5/8" EXT. SHEATHING 2 SIDES+INSULATION Wall W4A-2x4 + 5/8" G.B. ONE SIDE Wall W4Ai-2x4 + 5/8" G.B. ONE SIDE+INSULATION Wall W4B-2x4 + 5/8" G.B. BOTH SIDES Wall W4Bi-2x4 + 5/8" G.B. BOTH SIDES+INSULATION Type C8 GB8 M6 M8 S5Hi S6A S6Bi S6E S8D S8Di W4A W4Ai W4B W4Bi Plan View 8"7 5/8"5 5/8"7 5/8"5 1/4"6"5/8"6 5/8"5/8"6"5/8"7 1/4"5/8"6"5/8"7 1/4"5 5/8"3"5/8"9 1/4"5/8"8"5/8"9 1/4"3 1/2"5/8"4 1/8"3 1/2"5/8"4 1/8"5/8"3 1/2"5/8"4 3/4"4 3/4"Section View 8" 7 5/8" 5 5/8" 7 5/8" 5 1/4" 6 5/8" 7 1/4" 7 1/4" 9 1/4" 9 1/4" 4 1/8" 4 1/8" 4 3/4" 4 3/4" Wall Type Description 8" CAST IN PLACE CONCRETE WALL. 8" x 8" x 7 5/8" GLASS BLOCK 6" CONCRETE MASONRY WALL; NO SKIN. 8" CONCRETE MASONRY WALL; NO SKIN. SHAFT LINER WALL SYSTEM, ONE LAYER 1" LINER BOARD, 4" C-H STUDS 20 GA, 24" OC, TWO LAYERS 5/8", INSULATED. ROCKWOOL INSULATION AND GLASS MATT REQUIRED IF WALL IS ASSEMBLED PRIOR TO ROOFING. 6" METAL STUD, 16"O.C. MAX., 5/8" GYP. ON ONE SIDE. 6" METAL STUD, 16"O.C. MAX., 5/8" GYP. ON BOTH SIDES, 1HR EFFECTIVELY INSULATED. 6" METAL STUD, 16"O.C. MAX., 5/8" PLYWOOD ON ONE SIDE, EXTERIOR SHEATHING OTHER SIDE, VAPOR BARRIER. 8" METAL STUD, 16" O.C. MAX.,5/8" EXTERIOR SHEATHING BOTH SIDES,VAPOR BARRIER. ADDITIONAL VENEER CLADDING NOT SHOWN. 8" METAL STUD, 16" O.C. MAX.,5/8" EXTERIOR SHEATHING BOTH SIDES, INSULATED,VAPOR BARRIER. ADDITIONAL VENEER CLADDING NOT SHOWN. 2X4 WOOD STUD WALL; 16" O.C.,5/8" GYP. BD. ONE SIDE; NO SKIN OPPOSITE 2X4 WOOD STUD WALL; 16" O.C.,5/8" GYP. BD. ONE SIDE; NO SKIN OPPOSITE, INSULATED 2x4 WOOD STUD, 16" O.C. MAX., 5/8" GYP. ON BOTH SIDES, EFFECTIVELY FIRE BLOCKED 2x4 WOOD STUD, 16" O.C. MAX., 5/8" GYP. ON BOTH SIDES, EFFECTIVELY FIRE BLOCKED, INSULATED Fire Rating 2 HR - 4 HR 0 HR 2 HR - 4 HR 2 HR - 4 HR 2 HR 0 HR 1 HR 0 HR 1 HR 1 HR 0 HR 0 HR 1 HR 1 HR UL Listing IBC 722.3.2.4 --- IBC 722.3.2.4 IBC 722.3.2.4 U417 --- U425 --- U425 U425 --- --- U305 U305 STC Rating --- --- --- --- --- --- --- --- --- --- ±25 --- --- 30 TO 34 Thickness 8" 7 5/8" 5 5/8" 7 5/8" 5 1/4" 6 5/8" 7 1/4" 7 1/4" 9 1/4" 9 1/4" 4 1/8" 4 1/8" 4 3/4" 4 3/4" Wall W4F-2x4 WD STD;GRN; GYP Wall W4Hi-2x4 + 5/8" G.B. BOTH SIDES + 7/16" SHEATHING BOTH SIDES- 2 WYTHE - WP 3370 Wall W4Ni-2x4 + 5/8" G.B. INT. SIDE + 7/16" SHEATHING OPP SIDE Wall W6A-2x6 + 5/8" G.B. ONE SIDE Wall W6Ai-2x6 + 5/8" G.B. ONE SIDE+INSULATION Wall W6D-2x6 + 5/8" G.B. ONE SIDE, 5/8" EXT. SHEATHING Wall W6Di-2x6 + 5/8" G.B. ONE SIDE, 5/8" EXT. SHEATHING+INSULATION Wall W6Hi-2x6 + 5/8" G.B. BOTH SIDES+SHEAR SHTG+INSULATION Wall W6Ji-2x6 + 5/8" G.B. BOTH SIDES+RC+INSULATION Wall W6K-6" WD STD;5/8" PLY 1 SIDE W4F W4Hi W4Ni W6A W6Ai W6D W6Di W6Hi W6Ji W6K 5/8"3 1/2"5/8"4 3/4"5/8"3 1/2"7/16"1"3 1/2"5/8"9 11/16"4 9/16"5 1/2"5/8"6 1/8"5 1/2"5/8"6 1/8"5/8"5 1/2"5/8"6 3/4"5/8"5 1/2"5/8"6 3/4"5/8"1/2"5 1/2"5/8"7 1/4"5/8"1/2"5 1/2"5/8"7 1/4"5 1/2"5/8"6 1/8"4 3/4" 9 11/16" 4 9/16" 6 1/8" 6 1/8" 6 3/4" 6 3/4" 7 1/4" 7 1/4" 6 1/8" 2X4 WOOD STUD WALL; 16" O.C., 5/8" GYP. BD. ONE SIDE; GREEN BD. OPPOSITE. ONE LAYER 5/8” TYPE X GYPSUM WALL BOARD APPLIED TO EACH SIDE OF DOUBLE ROW OF 2X4 WOOD STUDS 16” O.C. ON SEPARATE PLATES 1 7/8” APART. SHEATHING REFERENCE SHEAR WALL SCHEDULE S-SERIES DRWGS. DRAFTSTOPPING REQUIRED IN AIR CAVITY. ROCKWOOL INSULATION REQUIRED IF WALL IS ASSEMBLED PRIOR TO ROOFING. 2X4 WOOD STUD WALL; 16" O.C., 5/8" GYP. BD. ONE SIDE; 7/16" PLYWOOD OPPOSITE. SHEATHING REFERENCE SHEAR WALL SCHEDULE S-SERIES DRWGS. 2X6 WOOD STUD WALL; 16" O.C.,5/8" GYP. BD. ONE SIDE; NO SKIN OPPOSITE 2X6 WOOD STUD WALL; 16" O.C.,5/8" GYP. BD. ONE SIDE; NO SKIN OPPOSITE, INSULATED 2x6 WOOD STUD, 16" O.C., 5/8" GYP. ONE 1HR SIDE,5/8" EXTERIOR SHEATHING OTHER SIDE, VAPOR BARRIER. 1HR EFFECTIVELY FIREBLOCKED. REFERENCE S- SERIES SHEETS, TIGHTER STUD SPACING MAY BE REQUIRED. ADDITIONAL VENEER CLADDING NOT SHOWN. 2x6 WOOD STUD, 16" O.C., 5/8" GYP. ONE 1HR SIDE, 5/8" EXTERIOR SHEATHING OTHER SIDE, VAPOR BARRIER. INSULATED, 1HR EFFECTIVELY FIREBLOCKED. ADDITIONAL VENEER CLADDING NOT SHOWN. 2x6 WOOD STUD, 16" O.C., 5/8" GYP. ONE 1HR SIDE, 5/8" SHEATHING + 5/8" GYP. OTHER SIDE, INSULATED, VAPOR BARRIER. 1HR EFFECTIVELY FIREBLOCKED. REFERENCE S- SEREIS SHEETS, TIGHTER STUD SPACING MAY BE REQUIRED. 2x6 WOOD STUD, 16" O.C., 5/8" GYP. ONE 1HR SIDE, 1/2" RC CHANNEL ON SIDE, INSULATED, 1HR EFFECTIVELY FIREBLOCKED. REFERENCE S- SEREIS SHEETS, TIGHTER STUD SPACING MAY BE REQUIRED. 2x6 WOOD STUD, 16" O.C., 5/8" GYP. ONE 1HR SIDE, 1/2" RC CHANNEL ON SIDE, INSULATED, 1HR EFFECTIVELY FIREBLOCKED. REFERENCE S- SEREIS SHEETS, TIGHTER STUD SPACING MAY BE REQUIRED. 1 HR 1 HR 0 HR 0 HR 0 HR 1 HR 1 HR 1 HR 1 HR 0 HR U305 WP3370 --- --- --- U356 U356 U356 U305 --- --- 45 TO 49 30 TO 34 --- --- --- 30 TO 34 30 TO 34 30 TO 34 --- 4 3/4" 9 11/16" 4 9/16" 6 1/8" 6 1/8" 6 3/4" 6 3/4" 7 1/4" 7 1/4" 6 1/8" WALL TYPE LEGEND Wall Composite Type Plan View Section View Wall Type Description Fire Rating UL Listing STC Rating Thickness