HomeMy WebLinkAboutA111 1st Floor RCPProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032800 West Monon Green BlvdPEDCOR DESIGN GROUP LLC A111 1st Floor RCP THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS #### LGA #### SCALE: NTS PLAN NORTH KEY PLAN Bldg I Revision ID Issue Date Issue Name 01 7/15/21 BP-1 Thursday, July 15, 2021, BIMcloud: pedcordesign - BIMcloud as a Service/Windsor - Building I/Building I Windsor5.1 5.1 1 1 D D E.9 E.9 3 3 7 7 C C E E F F 2 2 4 41.9 1.9 E.2 E.2 4.5 4.5 2 A1114"SIM. SIM. Elevator 1 Lobby 122 Commercial Tenant 120 P: 9,799 sq ft G: 9,799 sq ft Commercial Tenant 121 P: 3,279 sq ft G: 3,279 sq ft B B A A 5 5 6.1 6.1 A.1 A.1 6 6 8 1/4"5 3/4" 1'-2" 8 1/4"5 3/4" A1 A311 C1 A302 C1 A302 A1 A302 A1 A302 C3 A312 A1 A312 C2 A312 A1 A305 A2 A305 A1 A306 A1 A307 A2 A307 A1 A308 C3 A309 C2 A309 A2 A308 A1 A301 A1 A301 A2 A305 A1 A311 A1 A312 A1 A305 A2 A305 C2 A312 A2 A305 A1 A305 A1 A311 A1 A311 A2 A305 A1 A305 A1 A308 C2 A312 C2 A312 C3 A312 C2 A312 C3 A312 C2 A312 C2 A312 A2 A305 A1 A305 A1 A305 A1 A305 A2 A305 A1 A311 A1 A312 C2 A312 C4 A312 A1 A314 A4 A313 B4 A313 C2 A314 A4 A314 B4 A314 C1 A303 C1 A303 C1 A301 C1 A301 A1 A303 A1 A303 A3 A313 B3 A314 A1 A311 C2 A312 Stair 1 S1 Stair 2 S2 Commercial Tenant 121a P: 1,172 sq ft G: 1,189 sq ft A2 A305 A2 A305 2'EQ.3'3'EQ.B2 A401 4 2 REFERENCE E SERIES SHEETS FOR LIGHTING GENERAL CEILING NOTES: 1. Ceiling height desinated by benchmarck above finished floor (AFF). 2. Each room to have individual switch located on wall at doorway to room. Typical unless noted otherwise in locations of 2 or more switches in close proximity. Switches are to be consolidated to a gang plate condition. 3. Provide fire rated dampers required at fire rated walls. 4. Trades to coordinate the height of fire suppression lines , roof drain leaders, roof stack vents and condensate lines to allow for ceiling heights as indicated on the reflected ceiling plan. 5. See RCP plas and schedule for ceiling heights. 6. See E-Series sheet for electrical and data locations. 7. Gypsum Board Finishing: A. Comply with ASTM C 840 standard specification and finishing of gypsum board: GA 214 recommended levels of gypsum board finish and GA 216-2000 application and finishing of gypsum board. B. Provide gypsum board minimum finish levels meeting the criteria established in GA 214 as follows: 1. Level 1 - Gypsum wall board permanently concealed from veiw. 2. Level 2 - Gypsum board behind and applied wall covering and walls and ceiling in mechanical and equipment rooms. 3. Level 4 - Gypsum wall board on interior walls for all tenant areas. 4. Level 5 - Gypsum wall board on finished ceilings and all common area walls. CEILING NOTES: 1 Provide 1/4" control joint to be: Fry Reglet DRM-50-25-2-PC or equal. Ref. detail 14/A510. 2 Lobby Acoustical ceiling tile to be Armstrong, Dune Tegular 24"x24" w/ Prelunde XL 15/16" grid. 3 Align finished faces. 4 Provide drywall bulkhead, Ref. sht. A401 for section view. 5 Provide 12"x12" access panel for water shut valve at second floor location only. Access panel to be 1 hour rated assembly with security latch. Frame and panel are to be concealed flange type requiring drywall finishing and ceiling finish. 6 EIFS soffit / cornice at third floor. 0 4'8'16'SCALE: 1/8" = 1'-0"1 1st Floor Reflected Ceiling Plan 0 2'4'8'SCALE: 1/4" = 1'-0"2 ENLARGED ELEV. LOBBY CEILING PLAN