Loading...
HomeMy WebLinkAboutA308 Wall SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032800 West Monon Green BlvdPEDCOR DESIGN GROUP LLC A308 Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2021 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS #### LGA #### SCALE: NTS PLAN NORTH KEY PLAN Bldg I Revision ID Issue Date Issue Name 01 7/15/21 BP-1 1 1 2 2 3 3 4 4 5 5 A B C D A B C D BIMcloud: pedcordesign - BIMcloud as a Service/Windsor - Building I/Building I WindsorB3 A308 A4 A305 D4 A305 A4 A502 A4 A502 B2 A604 D1 A604 B2 A604 D1 A604 B2 A604 D1 A604 ±0" 1 1st Floor +17'-0" 2 2nd Floor +27'-9 1/2" 3 3rd Floor +38'-5 1/2" 4 4th Floor +49'-0" 5 Roof 27'-9 1/2" 38'-5 1/2" 48'-9 1/2" 17'-1 1/2" 1'-8"17'-0"10'-9 1/2"10'-8"10'-6 1/2"16'-0"1'-0"9'-1 1/4"1'-6"2 1/4"8'-11 3/4"1'-6"2 1/4"1'-8"7'-4 1/4"9'-0 1/4"6'-11 3/4"7'-4 1/8"1'-7 3/4"1 3/8"2'-10 7/8"4'-5 1/4"7'-2 5/8"1'-7 3/4"1 3/8"2'-9 3/8"4'-5 1/4"17'-0"10'-9 1/2"10'-8"7'-2 5/8"1'-7 5/8"1 1/2"1'-6 3/4"2'-9 3/8"4'-5 1/4"SF4 REF. DETAIL A2/A605 BRICK VENEER EIFS CORNICE 5, REF. 1/A504 CAST STONE WINDOW SURROUND BEYOND CAST STONE WATERTABLE, REF. #DrgID(ref)/#LayID(ref), CAST STONE BASE 2B CONC. FOUNDATION, REF. S-SERIES DWGS. REF. STRUCT. DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. R-21 HD BATT INSULATION CAST STONE BAND CAST STONE BAND CAST STONE BAND CAST STONE WATERTABLE BEYOND WINDOW - SINGLE HUNG, TYPICAL WINDOW - SINGLE HUNG, TYPICAL WINDOW - SINGLE HUNG, TYPICAL STOREFRONT, REF. SHT. A605 MTL. AWNING BY OTHERS, REF. SHT. A501 EIFS VENEER EIFS VENEER EIFS VENEER T/ STONE BAND T/ STONE BAND T/ STONE BAND T/ BRICK VENEER T/ STONE WATERTABLE EIFS WINDOW HEAD , REF. 3/A504, EIFS WINDOW HEAD ROUNDED SEE PERSPECTIVE C1/A320 SEE PERSPECTIVE C1/A321 SEE PERSPECTIVE C1/A321 SEE PERSPECTIVE C1/A321 SIM. SIM. EIFS CORNICE 5, REF. 1/A504 THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE 3 5/8" 3/8" 1 1/2"8" 7'-2 1/2" BRICK VENEER & WALL TIES LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER DOOR ASSEMBLY, REF. SHT. A601 FOR SCHEDULE 1 1/2" RIGID INSULATION CAST STONE DOOR SURROUND, REF. C1/A505, CAST STONE DOOR PROFILE SURROUND 4 CONC. SHAFT WALL THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS @ 24" O.C. BTM/ OPNG 48'-10 1/4" 48'-9 1/2" 7 1/2"3 1/8"3 5/8" 3/4" 1 1/2" 7 5/8"3/4"4'-0 3/8"2 3/4"1'-4 1/2" SLOPED PRE-FINISHED MTL. COPING, RETURN UP WALL BEHIND EIFS EIFS CORNICE 6 SIM., REF. 1/A504 LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER BACKER ROD AND SEALANT BRICK VENEER & WALL TIES 8" CMU 3/4" EIFS VENEER T/ BRICK VENEER BTM/ EIFS CORNICE 1 1/2" RIGID INSULATION MTL. FLASHING, RUN UP BEHIND EIFS LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. 63'-0"6 1/2"1 7/8"11 1/2"1'-0 1/2"1 1/2"3/4"1'-0 1/8"11 7/8" EIFS CORNICE 9, REF. 1/A504 LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER 8" CMU 2X6 WD. STUDS BACKER ROD AND SEALANT WD. JOISTS, REF. S- SERIES DWGS. PREFIN. MTL. COPING OVER 3/4" TREATED PLYWOOD T/ WALL MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. OSB SHEATHING SYSTEM (ZIP) POLYVINYL-CHLORIDE (PVC) ROOFING OVER 3/4" EXT. TREATED PLYWOOD DECK BD. POLYVINYL-CHLORIDE (PVC) ROOFING FLASHING OVER 3/4" PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING. RUN PVC ROOFING UP AND OVER PLYWOOD AND UNDER MTL. CORNICE CAP 61'-0" ROOF 3/4"7 5/8"1 3/4" TREATED PLATE & ANCHOR BLTS AT 32"O.C. SET IN GROUT FILLED BLK. CORES. B3 A308 A3 A308 A4 A308 B4 A308 ±0" 1 1st Floor +17'-0" 2 2nd Floor +27'-9 1/2" 3 3rd Floor +38'-5 1/2" 4 4th Floor +49'-0" 5 Roof +61'-0" 6 Roof 38'-5 1/2" 48'-9 1/2" 27'-9 1/2" 17'-1 1/2"7'-2 1/2"17'-0"61' 6'-8 1/2" 7'-4" 7 1/2" 3 1/8" 3 5/8" 3/4" 1 1/2" 7 5/8"3/4"4'-0 3/8"2 13/16"1'-4 1/2"6 9/16"1 7/8"11 1/2"1'-0 1/2"1 7/16"11/16"1'-0 1/8"11 7/8" BRICK VENEER EIFS CORNICE 6 SIM., REF. 1/A504 EIFS CORNICE 9, REF. 1/A504 CAST STONE WATERTABLE BEYOND CONC. FOUNDATION, REF. S-SERIES DWGS. REF. STRUCT. DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. CAST STONE BAND CAST STONE BAND CAST STONE BAND 8" CMU C.I.P. CONCRETE WALL, REF. S-SERIES DWGS. 1 1/2" RIGID INSULATION T/ STONE BAND T/ STONE BAND T/ STONE BAND T/ BRICK VENEER T/ DOOR HEAD T/ C.I.P. OPENING T/ CMU SEE PERSPECTIVE A3/A321 SEE PERSPECTIVE C2/A321 THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS AT 24" O.C. AT FLOOR LINE 3/4" 7 5/8" 1 3/4"1'-1"3/4"3/4"16'-9 1/8" 4 3/8"1 1/2" 5/8" 5 1/2"5/8" 2"3 5/8" 2 1/4" 6 3/4" 2 1/4"5/8"8"5/8"1'-0"2'-10 7/8"CAST STONE SILL, REF. B4/ A505, CAST STONE SILL 1 YORK THRU-WALL COPPER FLASHING W/ WEEPS @ 24" O.C. BRICK VENEER OSB SHEATHING SYSTEM (ZIP) WINDOW - SINGLE HUNG TYP. STEEL RELIEVING ANGLE, REF. S-SERIES DWGS. STEEL PLATE, REF. S- SERIES DWGS. BACKER ROD AND SEALANT 1 1/2" EIFS VENEER BACKER ROD AND SEALANT BACKER ROD AND SEALANT not (AFF) T/ STEEL ANGLE, B/ STONE BAND SLOPED EIFS TOP AT SILL CAST STONE WINDOW SURROUND, REF. #DrgID(ref)/#LayID(ref), CAST STONE WINDOW SURROUND 2 CAST STONE BAND, REF. B4/ A505, CAST STONE BAND 1 THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS @ 24" O.C. AT FLOOR LINE 24'-4" VERIFY 1'-1 3/8"1'-1 3/8" 2'-2 3/4" 3 3/4"5/8"9"9"5/8"3 3/4" 24'-5 3/8" VERIFY 28'-1 1/4" 9"9"1 1/4"±VERIFY1 3/8"1'-7 7/8"26'-1 1/4" 27'-4 1/2" FIBERGLASS REINFORCED PLASTIC COLUMN (FRP) BEYOND. 2x6 WD. STUD FRAMING EIFS CORNICE 3, REF. 1/A504 3 3/4" EIFS VENEER BACKER ROD AND SEALANT POLYVINYL-CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVERY BD., OVER TAPERED INSUL. BTM/ FRAMING BTM/ EIFS CORNICE VERIFY 3/4" EIFS SOFFIT OVER 5/8" EXT. SHEATHING 1/4" BACKER ROD AND SEALANT JOINT SOFFIT - DIRECT APPLIED FINISH SYSTEM OVER 5/8" EXT. SHEATHING. EXT. SHEATHING APPROVED BY EIFS MANUFACTURER PRE-FINISHED MTL. COPING OVER 3/4" TREATED PLYWD. BTM/ BEAM T/ WALL MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. OSB SHEATHING SYSTEM (ZIP) POLYVINYL-CHLORIDE (PVC) ROOFING FLASHING OVER 3/4" PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING. RUN PVC UP AND OVER PLYWOOD AND UNDER MTL. CORNICE CAP SEALANT & BACKER ROD T/DECK 1'-6 3/4"1 1/8"1'-2 1/2"3/4"8 3/4"3 5/8" 3/8" 1 1/2"8" 3 5/8" 3/4"1 1/2"7 5/8" 3/8" 16'-9 1/8" 17'-1 1/2" LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER 8" CMU CAST STONE BAND, REF. B4/A505 PROFILE BAND 1 STEEL RELIEVING ANGLE, REF. S-SERIES DWGS. REF. STRUCT. DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. 8" CONC. WALL, REF. S-SERIES DWGS. BRICK VENEER BACKER ROD AND SEALANT THRU-WALL STAINLESS STL. FLASHING W/ CORRUGATED HEAD WEEPS @ 24" O.C. T/STL. ANGLE T/STONE BAND 7 5/8" 24'-4" VERIFY 1'-10 7/8" 24'-5 3/8"3 3/4"3/4" 28'-1 1/4" 9"5 1/8"1 3/8"1'-7 7/8"1'-2 1/2"3/4"8 3/4"26'-1 1/4" 27'-4 1/2" MEMBRANE FLASHING POLYVINYL-CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVERY BD., OVER TAPERED INSUL. BTM/ FRAMING BTM/ EIFS CORNICE BACKER ROD AND SEALANT ALIGN EIFS EDGE BACKER ROD AND SEALANT T/ EXT. SHEATHING, B/ STRUCT. WD. BEAM PRE-FINISHED MTL. COPING OVER 3/4" TREATED PLYWD. T/ WALL MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. T/DECK EIFS CORNICE 3, REF. 1/A504 3 3/4" EIFS VENEER 3/4" EIFS SOFFIT OVER 5/8" EXT. SHEATHING 1/4" SEALANT JOINT CAST STONE WINDOW SURROUND BEYOND, REF. #DrgID(ref)/ #LayID(ref), CAST STONE WINDOW SURROUND 3 AT SECOND FLOOR 1'-1 3/8"9 1/2" 2x4 WD. STUD FRAMING SOFFIT - DIRECT APPLIED FINISH SYSTEM OVER 5/8" EXT. SHEATHING. EXT. SHEATHING APPROVED BY EIFS MANUFACTURE 1'-2 1/2" B5 A308 EIFS BRACKET, REF. 1/A504 EIFS CORNICE 2, REF. 1/A504 1/4" BACKER ROD AND SEALANT WHERE CORNICE MEETS BRACKETS SLOPED CONC. SLAB W/LIQUID APPLIED W.P. 3/4" EIFS VENEER 5/8" EXT. TREATED PLYWD. OVER 3 5/8" MTL. STUD FRAMING DRAIN PIPE, REF. P SERIES DWGS. BACKER ROD AND SEALANT MTL. CHANNELS FOR PLYWD. ANCHORAGE BY EIFS MANUF. LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER SEAL AROUND PIPE AT 4" CMU PENETRATION B4 A308 EIFS BRACKET, REF. 1/A504 BACKER ROD AND SEALANT SLOPED CONC. SLAB W/LIQUID APPLIED W.P. DRAIN PIPE, REF. P SERIES DWGS. 3/4" EIFS VENEER 5/8" EXT. TREATED PLYWD. OVER 3 5/8" MTL. STUD FRAMING NOTE: REF. 2/A206 FOR EXACT EIFS BRACKET TO BOX OUT WITH TREATED WD. PLYWD. NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS #LayID(ref) AND #LayID(ref). 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD ARE FIRE RETARDANT TREATED FOR PARKING AND FIRST FLOORS, INCLUDING THE WOOD AT ROOF, COPING AND PARAPET DETAILS AT THOSE FLOORS. AREAS ABOVE THE TYPE I CONSTRUCTION AND PART OF THE TYPE V CONSTRUCTION ARE NOT REQUIRED TO BE FIRE RETARDANT. 0 2'4'6'SCALE: 3/8" = 1'-0"A1 Wall Section 0 6''12''18''SCALE: 1 1/2"= 1'-0"B3 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"A3 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"A4 Section Detail 0 2'4'6'SCALE: 3/8" = 1'-0"A2 Wall Section 0 6''12''18''SCALE: 1 1/2"= 1'-0"C3 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"C4 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"B4 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"C4 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"A5 Section Detail 0 6''12''18''SCALE: 1 1/2"= 1'-0"B5 Section Detail SEE PERSPECTIVE A1/A321SEE PERSPECTIVE A2/A321