HomeMy WebLinkAboutE-000 - ELECTRICAL SYMBOLS AND ABBREVIATIONSELECTRICAL SYMBOL SCHEDULE CEIL WALL FL. MOUNTING DESCRIPTION UPPERCASE LETTER IN QUOTES -TYPELOWER CASE LETTER -SWITCHLEGRECESSED DOWNLIGHT H.I.D. FIXTURE RECESSED FIXTURE -DIRECTIONAL LIGHT FIXTURE ON EMERGENCY CIRCUIT SURFACE OR PENDANT MOUNTED FIXTURE EXIT LIGHT, LINE INDICATES FACE ARROW INDICATES FACE WITH ARROW BATTERY PACK LIGHTS TRACK LIGHT SINGLE RECEPTACLE SINGLE RECEPTACLE (+44" AFF) DUPLEX OUTLET DUPLEX OUTLET -GFI PROTECTED DUPLEX OUTLET (TOP HALF SWITCHED) RECEPTACLE (+44" AFF) QUADRUPLEX OUTLET QUADRUPLEX OUTLET (+44" AFF) SAFETY TYPE OUTLET DUPLEX OUTLET (EMERGENCY) WEATHERPROOF OUTLET (GFI) WEATHERPROOF OUTLET (GFI) (+44" AFF) EXPLOSION PROOF OUTLET SPECIAL OUTLET (AS NOTED) ABOVE COUNTER VOICE/DATA OUTLET (+44" AFF) VOICE/DATA OUTLET PUBLIC TELEPHONE OUTLET (VOICE ONLY) +48" DATA OUTLET (DATA ONLY) CLOCK OUTLET SOUND SYSTEM AMPLIFIER CAMERA VOLUME CONTROL SPEAKER SPEAKER (HORN TYPE) T.V. CABLE ANTENNA INTERCOM STATION INTERCOM MASTER STATION MICROPHONE OUTLET EMERGENCY PANIC BUTTON FIRE ALARM CONTROL CABINET FIRE ALARM ANNUNCIATOR (REMOTE) FIRE ALARM ANNUNCIATOR (REMOTE AND GRAPHIC) FIRE ALARM PULL STATION FIRE ALARM HEAT DETECTOR (RATE OF RISE) FIRE ALARM SMOKE DETECTOR (PHOTO-ELECTRIC) FIRE ALARM SMOKE DETECTOR (PHOTO- ELECTRIC WITH DUCT-PROBE) 208/240V OUTLET (SIZE AS NOTED) 208/240V OUTLET (SIZE AS NOTED) FLAME DETECTOR FIRE ALARM TAMPER SWITCH FIRE ALARM FLOW SWITCH FIRE FIGHTERS TELEPHONE JACK FIRE ALARM MAGNETIC DOOR HOLDER FIRE ALARM BELL/STROBE COMBINATION FIRE ALARM STROBE FIRE ALARM SPEAKER FIRE ALARM CHIME FIRE ALARM INDICATING LAMP (REMOTE) FIRE ALARM EMERGENCY TELEPHONE FIRE ALARM SPEAKER/STROBE COMBINATION FIRE ALARM HORN/STROBE COMBINATION FIRE ALARM HORN S EE WP WP C P CC AMP C C SS SS T T E FACP RA RAG F S T F P DH F SS C RR P H CONTACTOR CEIL WALL FL. MOUNTING DESCRIPTION TRANSFER SWITCH MANUAL STARTER (P -PILOT LIGHT) MAGNETIC MOTOR STARTER COMBO MAGNETIC MOTOR STARTER & DISCONNECT PUSHBUTTON STATION AS NOTED CIRCUIT BREAKER IN ENCLOSURE DISCONNECT SWITCH (NON-FUSED) DISCONNECT SWITCH (FUSED) SWITCH -SINGLE POLE SWITCH -2 POLE SWITCH -3 WAY SWITCH -4 WAY SWITCH WITH PILOT LIGHT (ANY TYPE SW.) SWITCH -WEATHERPROOF MOMENTARY CONTACT SWITCH MECHANICAL TIMER SWITCH KEYED SWITCH HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH W/ THERMAL OVERLOAD PROTECTIONDIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE INDICATED. "LV" = LOW VOLTAGE "FL" = FLUORESCENT DOOR BUZZER DOOR BELL OCCUPANCY SENSOR LOW VOLTAGE PUSH BUTTON WALL STATION PHOTOCELL MOTORIZED DOOR PUSH PLATE MAGNETIC LOCK (ROUGH-IN) AUTO-EQUALIZER (ROUGH-IN) POWER HINGE (ROUGH-IN) PNEUMATIC POWER TRANSFER (ROUGH-IN) MAGNETIC DOOR CONTACT ELECTRIC DOOR STRIKE EXIT ALERT, AUDIBLE, WITH LOCAL KEYSWITCH CONTROL BASKET TYPE CABLE TRAY OVERHEAD GROUND WIRE TO GROUND WIRE EXOTHERMIC WELD GROUND BUS BAR GROUND ROD TEST WELL WITH GROUND ROD MOTOR -SINGLE PHASE MOTOR -3 PHASE PLUGMOLD RACEWAY WIREMOLD RACEWAY CONDUIT CONCEALED IN OR ABOVE CEILING CONDUIT EXPOSED CONDUIT CONCEALED IN OR BELOW FLOOR HOMERUN CONDUIT TURNED UP CONDUIT TURNED DOWN DIRECT BURIED CABLE TWISTED PAIR CABLE CONDUIT STUBBED OUT & CAPPED CONDUIT STUBBED OUT WITH BUSHING JUNCTION BOXES GROUND ROD & CONNECTION THERMOSTAT TRANSFORMER TIME CLOCK 48V D.C. EMERGENCY LIGHT CIRCUIT BREAKER COIL (RELAY, CONTACTOR OR CONTROLLER) FUSE NORMALLY OPEN CONTACTS NORMALLY CLOSED CONTACTS NORMALLY OPEN MOMENTARY CONTACT NORMALLY CLOSED MOMENTARY CONTACT PILOT LIGHT SWITCH (MANUAL OR AS NOTED) TRANSFORMER CO N P CB F S 2S 3S 4S PS WPS MCS TS KS HS D B B WS PP H ML AE PH PN ES L WM JJ J T TC C P S S RESCUE ASSISTANCE STATIONRA 1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BIDDING AND BEGINNING WORK. 2. REVIEW THE WORK OF OTHER TRADES. COORDINATE AND PLAN WORK WITH THE OTHER TRADES. ADJUST AS A RESULT OF COORDINATION. REVIEW COORDINATED EFFORTS WITH ENGINEER FOR APPROVAL. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED ITEMS. 4. STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL READY FOR INSTALLATION. PROTECT FROM WEATHER, THEFT, DIRT, FUMES, WATER, CONSTRUCTION DEBRIS, ETC. AT ALL TIMES. ANY DAMAGED EQUIPMENT OR COMPONENT SHALL BE RESTORED AS NEW OR REPLACED. 5. DEMOLITION/REMODEL A. ALL MATERIALS REMOVED, AND NOT RELOCATED, BECOME THE PROPERTY OF THE CONTRACTOR. REMOVE MATERIALS FROM THE PROJECT SITE UNLESS NOTED OTHERWISE. OWNER HAS THE OPTION TO REVIEW ITEMS PRIOR TO REMOVAL AND RETAIN IF DESIRED. B. PATCH WALLS, FLOORS, CEILINGS, COLUMNS, ROOF PENETRATIONS, ETC. WHERE ITEMS ARE REMOVED TO MATCH FINISH OF ADJACENT SURFACES. C. RELOCATE EXISTING ITEMS AS REQUIRED FOR REMOVAL AND INSTALLATION OF WALLS, CEILINGS, DUCTWORK, PIPING AND EQUIPMENT. D. REMOVE ALL CONDUIT, WIRING, BOXES, SWITCHES, SUPPORTS, ETC. MADE UNNECESSARY, OR OBSOLETE AS A RESULT OF THIS PROJECT. E. EQUIP ALL OUTLET BOXES, CONCEALED BY CONSTRUCTION, WITH EXTENSION RINGS, BOXES, OR ACCESS PANEL TO MAINTAIN ACCESS TO BOXES AND WIRING. NOTE: CONTRACTOR HAS OPTION TO PROVIDE NEW HOME RUNS TO DOWNSTREAM OUTLETS IF EXTENSION BOXES OR ACCESS PANELS ARE IMPRACTICAL. F. REARRANGE EXISTING PANEL CIRCUITRY TO ACCOMMODATE REVISIONS. G. MAINTAIN EXISTING LIGHTING CIRCUITS. RELOCATE LIGHTING, AS SHOWN ON THE DRAWINGS, RECONNECTING TO SWITCHED OR UNSWITCHED CIRCUITS AS APPLICABLE. H. ALL ITEMS WITH NOTATION "EX" ARE TO REMAIN. I. ALL ITEMS WITH NOTATION "R" ARE RELOCATED, AS NOTED. 6. ELECTRICAL DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING OF ALL CONDUIT AND DEVICES. THEY SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. 7. PERFORM ALL WORK IN A SKILLED, PROFESSIONAL, MANNER MEETING THE ACCEPTANCE OF THE ENGINEER, ARCHITECT AND OWNER. 8. LABEL ALL RECEPTACLE DEVICES AS TO WHICH PANEL AND OVERCURRENT DEVICE FEEDS THE DEVICE WITH AN INDELIBLE MARKER ON THE BACK SIDE OF THE COVER PLATE. DEVICE WITH PLASTIC ENGRAVED PLATE ON THE FRONT SIDE OF THE COVER PLATE. 9. SMALLEST CONDUIT SIZE ALLOWABLE IS 3/4", AND SMALLEST WIRE SIZE ALLOWABLE IS #12 AWG COPPER UNLESS SPECIFICALLY NOTED OTHERWISE. ADJUST CIRCUIT AND CONDUIT SIZES FOR VOLTAGE DROP. 10. MOUNTING HEIGHTS OF DEVICES SHALL FOLLOW THE LISTING BELOW UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONVENIENCE OUTLET ..........................................................................+18" AFF TO CENTERLINE OF DEVICE TELEPHONE OUTLET ...............................................................................+18" AFF TO CENTERLINE OF DEVICE DATA OUTLET ............................................................................................+18" AFF TO CENTERLINE OF DEVICE LIGHT SWITCH OR DIMMER ...................................................................+48" AFF TO TOP OF DEVICE DEVICES ABOVE COUNTERTOP ...........................................................+44" AFF TO CENTERLINE OF DEVICE EXIT LIGHT .................................................................................................+96" AFF TO CENTERLINE OF DEVICE THERMOSTAT OR TEMPERATURE/HUMIDITY SENSOR ..................+46" AFF TO TOP OF DEVICE FIRE ALARM PULL STATION ...................................................................+48" AFF TO TOP OF DEVICE FIRE ALARM HORN ...................................................................................+80" AFF TO BOTTOM OF DEVICE FIRE ALARM STROBE ..............................................................................+80" AFF TO BOTTOM OF DEVICE FIRE ALARM COMBINATION HORN/STROBE ......................................+80" AFF TO BOTTOM OF DEVICE FIRE ALARM REMOTE ALARM LAMP ....................................................+96" AFF TO CENTERLINE OF DEVICE 11. CLEAN ALL EQUIPMENT TO PRESENT A "LIKE NEW" CONDITION AT PROJECT COMPLETION. VACUUM CLEAN INTERNAL AREAS OF EQUIPMENT AND PANELS. 12. CLEAN ALL MECHANICAL AND ELECTRICAL AREAS AND ROOMS OF DEBRIS AND UNUSED MATERIALS. VACUUM FLOORS. 13. THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, VERTICALLY ORIENTED, NEMA 5, 6, 7, 14 AND 15 RECEPTACLES SHALL BE SUCH THAT THE GROUND PIN IS UP (ABOVE PHASE AND NEUTRAL BLADES). THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, HORIZONTALLY ORIENTED, NEMA 5 AND 7 RECEPTACLES SHALL BE SUCH THAT THE NEUTRAL BLADE IS UP (ABOVE THE PHASE BLADE). 14. ALL ABOVE COUNTER DEVICES, LIGHT SWITCHES, RECEPTACLES AND TELE/DATA ROUGH-INS, TO BE MOUNTED AT THE SAME ELEVATION. COORDINATE WITH ARCHITECTURAL CASEWORK ELEVATIONS, SECTIONS AND WALL TYPES. 15. ELEVATORS -PROVISION FOR EACH ELEVATOR IS TO BE PER N.E.C ARTICLE 620 AND IS TO INCLUDE THE FOLLOWING: A. POWER FOR CONTROLLER AND MACHINE. a. GROUND CONDUCTOR IS TO BE THE SAME SIZE AS PHASE CONDUCTORS. b. CIRCUIT OVERCURRENT DEVICE WITH CHARACTERISTICS OF TYPE RK1 FUSE AND GROUND FAULT PROTECTION. ABLE TO BE LOCKED IN OPEN POSITION. c. DISCONNECT AT CONTROLLER. ABLE TO BE LOCKED IN OPEN POSITION. d. DISCONNECT AT MACHINE. ABLE TO BE LOCKED IN OPEN POSITION. e. CIRCUIT SIZES AND OVER CURRENT/DISCONNECT DEVICES ARE SHOWN AS BASIS OF DESIGN. CONTRACTOR TO COORDINATE AND PROVIDE AS REQUIRED BY SPECIFIC ELEVATOR MANUFACTURER. f. FOR ELEVATORS WITH BATTERY POWERED AUTO RETURN UNIT PROVIDE AUXILIARY CONTACTS AT MAIN LINE OVER CURRENT AND DISCONNECT DEVICES WITH CONTROL WIRING TO ELEVATOR CONTROLLER. B. 120V DEDICATED CIRCUIT FOR ELEVATOR CAR LIGHTS TO CONTROLLER. C. (2) TELEPHONE LINES FOR ELEVATOR CAR TO CONTROLLER. D. 120V POWER FOR GFCI RECEPTACLE AT LOCATION OF CONTROLLER AND LOCATION OF MACHINE. E. 120V POWER FOR GFCI RECEPTACLE IN PIT. F. LIGHTING AT CONTROLLER, MACHINE AND PIT –19 FC ON EMERGENCY POWER OR BATTERY BACKUP. G. FIRE ALARM a. (2) RELAYS FOR ELEVATOR RECALL AT CONTROLLER b. SMOKE DETECTOR AT ELEVATOR LOBBIES c. SMOKE DETECTOR IN CONTROLLER ROOM d. SMOKE DETECTOR AT MACHINE. 16.ALL ELECTRICAL PANELS IN APARTMENT UNITS ARE TO BE INSTALLED WITH TOP OF PANEL A MAXIMUM OF 48" A.F.F. 17.ALL WORK INCLUDING CIRCUITS, CONDUIT AND OVER CURRENT DEVICES REQUIRED FOR COMPLETE INSTALLATION IS NEW UNLESS SPECIFICALLY OTHERWISE NOTED. 18.IF OUTLETS BECOME BACK TO BACK THEY ARE TO BE MOVED OR SEPARATED BY 6" AND USE PUTTY PACKS. IF BOXES CANNOT BE MOVED AND FALL BACK TO BACK SEPARATE THE STUD CAVITY WITH DRYWALL ON THE BACK SIDE AND A HEADER OR BLOCKING ABOVE THE OUTLET TO NAIL OFF THE DRYWALL. ELECTRICAL EQUIPMENT DESIGNATION METHOD A,B,C,D INDEX H (blank) -NORMAL S -STANDBY E -LIFE SAFETY H -480/277V OR 480V L -208/120V (blank) -TRANSFORMER P -BRANCH CIRCUIT PANELBOARD D -DISTRIBUTION BOARD OR PANEL T -TRANSFORMER L -LIGHTING DIMMER PANEL M -MOTOR CONTROL CENTER R -LIGHTING RELAY PANEL EQUIPMENT TYPE POWER VOLTAGE U -UTILITY / LOWER LEVEL 1 -FIRST LEVEL 2 -SECOND LEVEL 3 -THIRD LEVEL R -LOWER / UPPER ROOF LEVEL FLOOR LEVEL DESIGNATION D U A T T CT # M M TS M DK K IAM ZAM CR H S D RTS S A S E S SC B R B S C F H H2 D FS PS PIV TV TV M MM IC MI VC TCC CCTV MTV B DR IC MI MD ML CR SCP DC K M CM D WM J D S S P N L E XX' xxxV WIRE WAY XX' xxxV BUS DUCT G DRAWING BLOCK TITLE SCALE:1/8" = 1'-0"0 16'8'4' N xxAF yyAT xxAF yyAT CT zzA zzA K2 XX-XX-X-X 3 MO ST 1 A1 E-401 A1 E-501 A1 E-301 GENERAL ELECTRICAL NOTES SECTION INDICATOR:REFERENCE SECTION LOCATION THROUGH AN AREA FOR ADDITIONAL INFORMATION. KEYNOTE INDICATOR:REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL INFORMATION. DETAIL INDICATOR:REFERENCE DETAIL LOCATION FOR ADDITIONAL INFORMATION. DRAWING BLOCK TITLE INDICATOR: REFERENCE DRAWING MODULE LOCATION FOR ADDITIONAL INFORMATION. MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL INFORMATION. REVISION INDICATOR:REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. LIGHTING INDICATOR:REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. "A" = FIXTURE TYPE, REFER TO FIXTURE SCHEDULE, "2" = CIRCUIT NUMBER, "a" = SWITCH IDENTIFICATION 2'x4' FIXTURE SUSPENDED FIXTURE WALL MOUNTED FIXTURE LUMINAIRE STRIP TYPE FIXTURE DOUBLE OR SINGLE HEAD SPOT LIGHT IN-GROUND OR FLOOR MOUNTED FIXTURE POLE MOUNTED SITE LIGHTING FIXTURE SINGLE LUMINAIRE SITE LIGHTING FIXTURE TWIN LUMINAIRE SITE LIGHTING FIXTURE BOLLARD TYPE SITE LIGHTING FIXTURE LIGHTING OR POWER PANEL, RECESSED LIGHTING OR POWER PANEL, SURFACE DISTRIBUTION PANEL LIGHTING OR POWER PANEL ON NORMAL/GENERATOR FEEDER DISTRIBUTION PANEL ON NORMAL/GENERATOR FEEDER MOTOR CONTROL CENTER (MCC) TRANSFORMER-PAD MOUNT CURRENT TRANSFORMER CABINET MOTOR METER METER AND SOCKET FIRE ALARM MASTER BOX FIRE FIGHTER'S PHONE DRILL KEY SWITCH KEY REPOSITORY (KNOX BOX) INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES CONTACT CLOSURE) CONTROL RELAY REMOTE STATION FOR DUCT DETECTOR USED AT DUCT WORK OPENING AREA TYPE SMOKE DETECTOR USED AT DUCT WORK OPENING ELEVATOR RECALL WITH AUXILIARY CONTACTS SELF CONTAINED SMOKE DETECTOR-SINGLE STATION TYPE BEAM SMOKE DETECTOR, "R"-INDICATES RECEIVER BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH BATTERY BACKUP HYDROGEN DETECTOR MOTOR OPERATED FIRE/SMOKE DUCT DAMPER LOW PRESSURE SWITCH, BY DIVISION 15 POST INDICATOR VALVE, BY DIVISION 15 MASTER ANTENNA SYSTEM OUTLET (MATV) EQUIPMENT CABINET EQUIPMENT RACK-WALL MOUNTED EQUIPMENT RACK-FREE STANDING TERMINAL CABINET WITH 3/4" PLYWOOD BACKING PLYWOOD BACKBOARD CCTV COAXIAL CABLE OUTLET AND POWER OUTLET CCTV MONITOR OUTLET DOOR CHIME ELECTRIC DOOR OPENER INTERCOM UNIT - FLUSH MOUNT MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR SECURITY DOOR ALARM MAGNETIC LOCK SECURITY CARD READER. "WP" INDICATES WEATHER-PROOF SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD &AND EMT ELECTRICAL METALLIC TUBING OCP OVERCURRENT PROTECTION PHASE ETR EXISTING TO REMAIN OD OUTSIDE DIAMETER, OVERFLOW DRAIN °F DEGREES FAHRENHEIT EWC ELECTRIC WATER COOLER OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED A/C AIR CONDITIONING EX EXISTING OL OVERLOAD A AMPERES FCU FAN COIL UNIT OZ OUNCE ACCU AIR COOLED CONDENSING UNIT FLR FLOOR P POLE, PHASE, PARALLEL AF AMPERE FUSE FP FIRE PUMP PE PNEUMATIC ELECTRIC AFC ABOVE FINISHED COUNTER FPVAV FAN POWERED VAV UNIT PF POWER FACTOR AFF ABOVE FINISHED FLOOR FT FOOT, FEET PH PHASE AFG ABOVE FINISHED GRADE FURN FURNACE PTAC PACKAGED TERMINAL AIR CONDITIONER AHU AIR HANDLING UNIT G GROUND, GALLONS PVC POLYVINYL CHLORIDE CONDUIT/PIPE AIC AMPERES INTERRUPTING CAPACITY GC GENERAL CONTRACTOR RCPT RECEPTACLE AL ALUMINUM GFI GROUND FAULT INTERRUPTING REV REVOLUTIONS ANSI AMERICAN NATIONAL STANDARDS INSTITUTE GFCI GROUND FAULT CIRCUIT RGS RIGID GALVANIZED CONDUIT ARCH ARCHITECT GRD GROUND RM ROOM ATS AUTOMATIC TRANSFER SWITCH GND GROUND RPM REVOLUTIONS PER MINUTE AVG AVERAGE HHWP HEATING HOT WATER PUMP RPS REVOLUTIONS PER SECOND BAS BUILDING AUTOMATION SYSTEM HOA HAND-OFF-AUTOMATIC RTU ROOF TOP UNIT B/I BYPASS ISOLATION HORIZ HORIZONTAL SF SQUARE FOOT BE BOTTOM ELEVATION HP HORSEPOWER SPEC SPECIFICATION BLDG BUILDING HR HOUR(S)SQ SQUARE BMS BUILDING MANAGEMENT SYSTEM HRTU HEATING ONLY ROOFTOP UNIT ST SHUNT TRIP BSMT BASEMENT Hz HERTZ STD STANDARD C CONDUIT IAC INSTRUMENTATIONS AND CONTROLS SW SWITCH CB CIRCUIT BREAKER ID INSIDE DIAMETER TBD TO BE DETERMINED CBA COLOR BY ARCHITECT IN INCH, INCHES TBI TO BE INSTALLED CCW COUNTERCLOCKWISE INT INTERIOR TBR TO BE REMOVED CH CHILLER JP JOCKEY PUMP TC TEMPERATURE CONTROLS CHWP CHILLED WATER PUMP K KELVIN, KEYED TCC TEMPERATURE CONTROLS CONTRACTOR CLG CEILING kW KILOWATT TR TAMPER RESISTANT CMT CONDUIT EMPTY KVA KILOVOLT AMPS TEMP TEMPERATURE COMPR COMPRESSOR LBS POUNDS TF TRANSFER FAN COND CONDENSER LSI, LSIG TRIP TYPE - LONG, SHORT, INSTANTANEOUS, GROUND FAULT TRANS TRANSITION CONV CONVECTOR LTG LIGHTING TYP TYPICAL CT COOLING TOWER MAX MAXIMUM UH UNIT HEATER CU CONDENSING UNIT, COPPER MC MECHANICAL CONTRACTOR UON UNLESS OTHERWISE NOTED CUH CABINET UNIT HEATER MCA MINIMUM CIRCUIT AMPS UV UNIT VENTILATOR CUV CLASSROOM UNIT VENTILATOR MCC MOTOR CONTROL CENTER V VOLTS CW CLOCKWISE MFR MANUFACTURER VAV VARIABLE AIR VOLUME CWP CONDENSER WATER PUMP MIN MINIMUM VB VACUUM BREAKER D DEDICATED CIRCUIT MISC MISCELLANEOUS VERT VERTICAL DC DIRECT CURRENT MOP MAXIMUM OVERCURRENT PROTECTION VF VENTILATION FAN DS DISCONNECT SWITCH MTD MOUNTED VFD VARIABLE FREQUENCY DRIVE DWH DOMESTIC WATER HEATER MV MEDIUM VOLTAGE W WIRE, WATT DWG DRAWING NA NOT APPLICABLE WP WEATHERPROOF EA EACH NEC NATIONAL ELECTRIC CODE W/WITH EC ELECTRICAL CONTRACTOR NIC NOT IN CONTRACT W/O WITHOUT EF EXHAUST FAN NL NIGHT LIGHT WSHP WATER SOURCE HEAT PUMP EFF EFFICIENCY NOM NOMINAL EL ELEVATION NTS NOT TO SCALE CUSTOMER METER DEMAND METER (UTILITY) WATTHOUR METER (UTILITY) DUPLEX RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT QUAD RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT MULTI-OUTLET ASSEMBLY MULTI-OUTLET ASSEMBLY FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH POWER AND VOICE/DATA RECEPTACLES JUNCTION BOX TOGGLE DISCONNECT SWITCH THERMAL MOTOR SWITCH WITH HANDLE GUARD AND PADLOCK CAPABILITY, "P"-INDICATES PILOT LIGHT PHASE, NEUTRAL, GROUND PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, PHASE, NEUTRAL, GROUND PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND PHASE, PHASE, GROUND PHASE, PHASE, PHASE, GROUND HOMERUN PHASE, NEUTRAL, GROUND, HOMERUN CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME SIZE, "yyAT" INDICATES TRIP SIZE CURRENT TRANSFORMER CABINET DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH AIR BREAK WITH FUSE,"zzA" INDICATES FUSED RATING FUSE, "zzA" INDICATES FUSED RATING OVERLOAD RELAY GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT KIRK KEY INTERLOCK SYSTEM LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL PHASES MOTOR AND LABEL, "3" DENOTES HORSEPOWER MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH RESISTOR SHUNT TRIP MAGNETIC STARTER WITH NEMA SIZE INDICATED GENERATOR BUS DUCT OR BUS WAY WIRE WAY TRANSFER SWITCH REFERENCE SYMBOLS ABBREVIATIONS AND TERMS S S F 1SEE E-102 REFER TO ADDITIONAL SHEET FOR CONTINUATION FLOOR PLAN OVERLAP BEYOND AREA EXTENSION PLAN A a 2 DRAWING MODULE LOCATION (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) GRAPHIC SCALENUMERIC SCALE NORTH ARROW SECTION LOCATION IN DRAWING MODULE SECTION LOCATION AT SUBSET SHEET PLAN BEYOND AREA EXTENSION DETAIL LOCATION IN DRAWING MODULE DETAIL LOCATION AT SUBSET SHEET LARGE SCALE VIEW LOCATION IN DRAWING MODULE LARGE SCALE VIEW LOCATION AT SUBSET SHEET REVISION CLOUD REVISION INDICATOR 11 1 KEYNOTE INDICATORS AREA LEADER LINE LEADER POINT LEADER NUMERICAL CHARACTER RELATES TO ITEM A1 M P S F S Ø FIRE ALARM SMOKE DETECTOR (2 AUX. CONTACTS) SYMBOL DESCRIPTION F H CAPACITORC LINETYPE DESIGNATORS THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS. INTERMEDIATE DASHED LINETYPE INDICATE ITEMS TO BE REMOVED ON COMBINATION PLANS. INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE WORK TO BE INCLUDED. THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE. INDICATES POINT OF CONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. INDICATES POINT OF DISCONNECTION TO EXISTING EQUIPMENT, PIPING OR MATERIALS. SHEET TYPE DESIGNATORS 000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) 100 PLANS 200 PLANS (SECONDARY) 300 ENLARGED PLANS & SECTIONS 400 SCHEMATICS & DIAGRAMS 500 SCHEDULES 600 DETAILS 700 CONTROL DIAGRAMS 800 (USER DEFINED) 900 3D REPRESENTATIONS (ISOMETRICS) NOTATION DESIGNATORS GENERAL MECHANICAL NOTES: NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE DISCIPLINE. GENERAL SHEET NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR.SHEET PLAN NOTES:NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A PLAN NOTE INDICATOR TO IDENTIFY ITEMS. DISCIPLINE DESIGNATORS M-000 MECHANICAL FP000 FIRE SUPPRESSION P-000 PLUMBING PD000 PLUMBING DEMOLITION H-000 HVAC HD000 HVAC DEMOLITION HP000 HVAC PIPING SHEET PLAN NOTES 1. C C MC zzA zzA NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTNOTIFICATION APPLIANCE CABINETNAC 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.E-000 ELECTRICAL SYMBOLS AND ABBREVIATIONS 08/31/202108/31/2021 KREG SMEAD BARRY SIMPSON