HomeMy WebLinkAboutE-302 - ELECTRICAL ENLARGED UNIT PLANSS
S
S
S SSSSMS
S
S
S
STVTVTV
TVTVJ
TV
S
S
S
S
S
S
S
H
S
S
SSSSS
TVTV TVTVJ
TVM 1
'L1'
1
'L1'
27
'L2'1
'L2'
1
'L2'
1
'L1'
25
'L2'
1
'L6'
1
'L6'
1
'L2'
1
'L2'
1
'L2'
1
'L2'
1
'L2'
1
'L2'
23
'L2'
1
'L2'1
'L2'1
'L7'
23
'L3'
25
'L3'
1
'L3'
27
'L3'
EF-1
EF-1
EF-1
C1
FCU-4
1
234
5
67
8
10
11
14
9
14
12
12
11
12
11
14
12
11
15
15
14
30
18
18 30
25
27 27
23
20
20
28
28
28
28
26
26
2626
26
19
21
21 21 20
21
24
24
2424
24
22 3,5
2,4
10
11
19
7,9
6,8
16
25
27
23
1513
28
19
1
'L8'
1
'L5'
12
12
14
12
28
1
'L2'
17
18
19
20
14
21
19
2,4
19
19
18
18
19
21
19
26
7' - 2"
8' - 6"7' - 0"EQ.3' - 0"EQ.
4' - 6"10' - 0"USB
20
17
22
23
24
29
USB
USB
USB
28
USB
1
'L9'
15
1
'L9'
1
'L9'
11
+44"
a
a
3b
bbb
3b
c
c
d
dd
d d
e
f
e,f
g
f f
f
g g
h
h
a
b
c
a,b
c
a
b
c
c
a,b
d c b a
a
a
b
c
d
b ca
c
b
a
ab
c
a
b
c a b c
a,b
c
3j
j
j
3j
25
25 25
25
USB
C2
1
'L7'
1
'L6'
1
'L6'
1
'L2'1
'L5'
1
2
3
5
6
7
10
11
12
9
19
10
19
19
19
19
22
21
22
22
22
22
22
14
19
14
'L2'
25
'L2'
1
'L2'
1
'L2'
1
'L2'
1
'L2'
25
'L4'
25
'L4'
1
'L1'
1
'L1'
28
28
28 28
28
1
'L1'
1
'L1'
23 23
23
23
23
11
23
11
1111
20
14
'L4'14
'L4'
14 8
30
30
29
25
11
FCU-3 15,17
6,8
1
'L8'
15
15
15
14
EF-1
1
'L2'
1
'L2'
1
'L2'
1
'L2'
1
'L2'
27
25
EF-1
12
12
12
14
14
14
14
12
12
12
16,18
1
'L2'6' - 0"6' - 0"3' - 0"6' - 0"
14
21
2,4
20
20
24
20 24
19
19
19
18
14
3,5
17
18
4
28 28
19
19
223' - 6"6' - 6"6' - 6"6' - 6"7' - 6"6' - 0"EQ.4' - 0"EQ.1
'L7'
USB
22
3b
1
'L2'1
'L2'
30 30
30
9
24
USB
26
30
22
23
11
USB
USB
1
'L9'
1
'L9'1
'L9'
11
USB
+44"6' - 0"a
a a
3b
b
b
3c
ccc
3c
d
d
d
f
f
f
f
f f
f
e
e
e
j
j
a b c c
a,b
c b ac
a,b
k
k
a
b
c
a,b
c
a
b
c c
a a
b
b
a
c
b a a
c
2525
18166
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS800 West Monon Green Blvd.E-302
ELECTRICAL
ENLARGED UNIT
PLANS
08/31/202108/31/2021
KREG SMEAD BARRY SIMPSON
0 8'4'2'
0 8'4'2'
SHEET PLAN NOTES
1 RANGE. INSTALL NEMA 14-50R FLUSH MOUNTED RECEPTACLE AT +24” AFF.
BRANCH WIRING TO BE 3-#6 AND 1-#10 GRD COPPER CONDUCTORS.
2 DRYER. INSTALL NEMA 14-30R FLUSH RECEPTACLE AT +36” AFF. BRANCH
WIRING TO BE 3-#10 AND 1-#10 GRD COPPER CONDUCTORS.
3 WATER HEATER. BRANCH WIRING TO BE 2-#10 AND 1-#10 GRD COPPER
CONDUCTORS. CONNECT CIRCUIT TO WATER HEATER THROUGH
DISCONNECT SWITCH INSTALLED ADJACENT TO WATER HEATER. INSTALL
DISCONNECT SWITCH TO ALLOW FOR MINIMUM CODE REQUIRED WORKING
CLEARANCE.
4 FAN COIL UNIT (FCU). REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR
CIRCUIT CONDUCTOR SIZE BASED ON FCU SIZE. CONNECT CIRCUIT TO FCU
THROUGH DISCONNECT SWITCH INSTALLED ADJACENT TO THE FCU. INSTALL
DISCONNECT SWITCH TO ALLOW FOR MINIMUM CODE REQUIRED WORKING
CLEARANCE.
5 ROUGH-IN FOR WALL MOUNTED MICROWAVE/HOOD UNIT. INSTALL ROUGH-IN
AT +64” AFF UNLESS OTHERWISE NOTED. INSTALL ELECTRICAL ROUGH-IN
AND WIRING PER THE REQUIREMENTS PROVIDED WITH THE
MANUFACTURERS INSTALLATION MANUAL.
6 SPLIT WIRED DUPLEX RECEPTACLE INSIDE LOWER SINK CABINET. TOP HALF
OF DUPLEX FOR DISPOSAL CONTROLLED BY DISPOSAL SWITCH LOCATED
ABOVE COUNTER OR BELOW SINK.
7 CONNECT DISHWASHER WITH CORD AND PLUG TO THE UNSWITCHED LOWER
HALF OF SPLIT DUPLEX RECEPTACLE.
8 TELECOMMUNICATIONS HOME NETWORKING FLUSH MOUNTED CABINET.
PROVIDE RECEPTACLE INSIDE THE CABINET ENCLOSURE. VERIFY EXACT
LOCATION WITH THE OWNER AND THE OWNER’S TELECOM SYSTEMS
PROVIDER PRIOR TO INSTALLING ROUGH-IN.
9 CONNECT RECEPTACLE WITH (2) USB CHARGING PORTS TO GFI
FEED-THROUGH TERMINALS OF ADJACENT GFI TYPE RECEPTACLE OUTLET.
MOUNT BOTH RECEPTACLES IN SAME BOX WITH 2-GANG COVERPLATE.
10 EXTEND CIRCUIT FROM LOADCENTER TO THE HVAC CONDENSING UNIT (CU)
ASSOCIATED WITH THIS APARTMENT AND LOCATED ON THE ROOF. REFER TO
MECHANICAL EQUIPMENT SCHEDULE FOR CIRCUIT CONDUCTOR SIZE BASED
ON CU SIZE.
11 PROVIDE ONE DUPLEX RECEPTACLE AND ONE WIRED “F” TYPE TV JACK WITH
ONE RG-6 COAX CABLE FROM THIS OUTLET TO THE HOME NETWORKING
ENCLOSURE CABINET.
12 PROVIDE FIRE ALARM SYSTEM STROBE ROUGH-IN WITH BLANK COVERPLATE
AND PROVIDE WIRING IN THESE BOXES FOR INSTALLATION OF FUTURE
SYSTEM STROBE.
14 PROVIDE SYSTEM DETECTOR WITH AUDIBLE SOUNDER BASE MEETING NFPA
72 CODE REQUIREMENT FOR LOW-FREQUENCY, 520 HZ TONE.
15 CEILING FAN. INSTALL BOX RATED FOR CEILING FAN INSTALLATION. FAN
MOUNTED LIGHTING FIXTURE AND FAN EACH TO BE CONTROLLED BY
INDIVIDUAL WALL SWITCHES AS INDICATED.
17 DEDICATED RECEPTACLE FOR WASHER.
18 CONNECT EXHAUST FAN TO SWITCH ON WALL.
19 USB DUPLEX RECEPTACLE.
20 GFCI RECEPTACLE BELOW COUNTER TOP.
21 GARBAGE DISPOSAL SWITCH BELOW SINK IN PENINSULAS OR ISLANDS.
22 WINE COOLER. INSTALL RECEPTACLE BELOW COUNTER.
23 DUPLEX RECEPTACLE WITH USB FOR KEY DROP. MOUNT TOP OF DEVICE +44"
A.F.F.
24 J-BOX IN CEILING FOR FUTURE FAN. PROVIDE WIRING FOR FUTURE FAN AND
TWO SWITCHES, ONE FOR FAN AND ONE FOR FAN LIGHT. INSTALL BLANK
COVER PLATE WHERE NO LIGHT FIXTURE IS INITIALLY INSTALLED.
25 CENTER VANITY LIGHT FIXTURE ABOVE MIRROR.
1/4" = 1'-0"
UNIT 'C1' ELECTRICAL ENLARGED PLAN1
1/4" = 1'-0"
UNIT 'C2' ELECTRICAL ENLARGED PLAN2