Loading...
HomeMy WebLinkAboutE-402 - TELECOMMUNICATIONS RISER DIAGRAMSCALE: FS SCALE:12 SS SS TS PIV SHEET KEYNOTES FIRE ALARM CONTROL PANEL MONITOR MODULE BUILDING SPRINKLER FLOW SWITCH (TYPICAL) TO ADDITIONAL SYSTEM SIGNAL NOTIFICATION APPLIANCES IN COMMON AREAS TO ADDITIONAL SYSTEM INITIATING DEVICES IN COMMON AREAS MONITOR MODULE BUILDING SPRINKLER VALVE TAMPER SWITCH (TYPICAL) RELAY MODULE TO ELEVATOR EQUIPMENT FOR ELEVATOR RECALL SPRINKLER BELL NOTE:THIS DIAGRAM IS TYPICAL FOR THE SYSTEM. SEE THE FLOOR PLANS FOR SYSTEM EQUIPMENT LOCATIONS AND QUANTITIES. MONITOR MODULE BUILDING SPRINKLER VALVE TAMPER SWITCH (TYPICAL) TO SIGNAL NOTIFICATION SPEAKERS IN EACH APPARTMENT PROVISIONS FOR FUTURE VISUAL NOTIFICATION DEVICES IN EACH APARTMENT FIRST FLOOR TELEPHONE/CABLE TELEVISION OUTLET (TYPICAL FOR ALL APARTMENTS - SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG-6 COAX CABLE (TYPICAL) TELEPHONE/CABLE TELEVISION OUTLET (TYPICAL FOR ALL APARTMENTS - SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG6 COAX CABLE FOR CABLE TELEVISION SERVICE AND TELEPHONE SERVICE TO EACH APARTMENT UNIT. SEE POWER PLANS FOR QUANTITY AND LOCATIONS OF APARTMENT UNITS. PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG-6 COAX CABLE (TYPICAL) PROVIDE ONE 1 1/4" CONDUITS STUBBED UP THROUGH ROOF FOR FUTURE CCTV/SERCURITY SYSTEM CABLING. PROVIDE WEATHERHEAD ON CONDUIT. ROOF PROVIDE 3/4" X 8'W X 8'H PLYWOOD BACKBOARD IN I.T. ROOM 101 FOR INCOMING TELEPHONE AND CABLE TELEVISION SYSTEM EQUIPMENT. TELEPHONE AND CABLE TELEVISION SYSTEM EQUIPMENT BY OWNER'S VENDORS. HOME NETWORKING ENCLOSURE (TYPICAL FOR ALL APARTMENTS. SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) HOME NETWORKING ENCLOSURE (TYPICAL FOR ALL APARTMENTS. SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG6 COAX CABLE FOR CABLE TELEVISION SERVICE AND TELEPHONE SERVICE TO EACH APARTMENT UNIT. SEE POWER PLANS FOR QUANTITY AND LOCATIONS OF APARTMENT UNITS. PROVIDE TWO (2) 4" CONDUITS BETWEEN COMMUNICATIONS PLYWOOD BACKBOARDS. PROVIDE BUSHINGS AT EACH END. 101 TELEPHONE/CABLE TELEVISION OUTLET (TYPICAL FOR ALL APARTMENTS - SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG6 COAX CABLE FOR CABLE TELEVISION SERVICE AND TELEPHONE SERVICE TO EACH APARTMENT UNIT. SEE POWER PLANS FOR QUANTITY AND LOCATIONS OF APARTMENT UNITS. PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG-6 COAX CABLE (TYPICAL) HOME NETWORKING ENCLOSURE (TYPICAL FOR ALL APARTMENTS. SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) TELEPHONE OUTLETS FOR ELEVATORS AND FIRE ALARM CONTROL PANEL PROVIDE ONE (1) CAT 5E VOICE CABLE (TYPICAL) WINDSOR BUILDING SECOND FLOOR THIRD FLOOR FOURTH FLOOR GARAGE LEVEL TELEPHONE/CABLE TELEVISION OUTLET (TYPICAL FOR ALL APARTMENTS - SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG-6 COAX CABLE (TYPICAL) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG6 COAX CABLE FOR CABLE TELEVISION SERVICE AND TELEPHONE SERVICE TO EACH APARTMENT UNIT. SEE POWER PLANS FOR QUANTITY AND LOCATIONS OF APARTMENT UNITS. HOME NETWORKING ENCLOSURE (TYPICAL FOR ALL APARTMENTS. SEE ENLARGED FLOOR PLANS FOR QUANTITIES AND LOCATIONS) PROVIDE ONE (1) CAT 5E DATA CABLE AND ONE (1) RG6 COAX CABLE FOR CABLE TELEVISION SERVICE AND TELEPHONE SERVICE TO EACH APARTMENT UNIT. SEE POWER PLANS FOR QUANTITY AND LOCATIONS OF APARTMENT UNITS. (2) 4" UNDERGROUND CONDUITS TO PROPERTY LINE. SEE ELECTRICAL SITE PLAN. TELEPHONE AND CABLE TELEVISION SYSTEM DISTRIBUTION DIAGRAMSTYPICAL FIRE ALARM SYSTEM DISTRIBUTION DIAGRAM NONE 1 PROVIDE INSULATED BUSHINGS ON CONDUIT ENDS. 2 PROVIDE TWO (2) 4" CONDUIT SLEEVES FOR TELEPHONE AND CATV TELEVISION SYSTEM CABLES. PROVIDE INSULATED BUSHINGS ON CONDUIT ENDS. CABLING PROVIDED BY BRIGHT HOUSE NETWORKS. 3 ROUTE TELEPHONE AND CATV CABLING FROM APARTMENTS TO PLYWOOD BACKBOARD IN THE JANITOR/MECHANICAL CLOSET. CABLING FURNISHED AND INSTALLED UNDER THIS CONTRACT. 4 PROVIDE CONDUIT SLEEVE UP THROUGH ROOF FROM THIRD FLOOR TELECOMMUNICATIONS PLYWOOD BACKBOARD FOR FUTURE CCTV/SECURITY SYSTEM CABLING. PROVIDE INSULATED BUSHINGS ON CONDUIT END AT BACKBOARD. NONE 3 4 3 2 1 1 3 L S L S SSS L L 3 3 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.E-402 TELECOMMUNICATIONS RISER DIAGRAM 08/31/202108/31/2021 KREG SMEAD BARRY SIMPSON