HomeMy WebLinkAboutE-601 - ELECTRICAL DETAILSH S B B B SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: SCALE: ELECTRICAL ROUGH-IN AT DOOR FRAME FOR CARD ACCESS AND SECURITY SYSTEM NONE11 CEILING T-BAR CEILING STRUCTURE LAY-IN FIXTURE SUPPORT DETAIL NONE2 TYPICAL APARTMENT UNIT SWITCH LIGHT AND FUTURE CEILING FAN DETAIL NONE3 GROUNDING TRIANGLE DETAIL NONE4 OCCUPANCY SENSOR MOUNTING DETAIL NONE5 TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM NONE6 ELECTRICAL SERVICE GROUNDING BUSBAR DETAIL NONE7 EXIT LIGHT ON LAY-IN CEILING MOUNTING DETAIL NONE8 TYPICAL OCCUPANCY SENSOR POWER/ SWITCHING AND RELAY PACK MOUNTNG DETAIL NONE9 TELECOMMUNICATIONS SERVICE ENTRANCE POINT MAIN GROUNDING BUSBAR (TMGB) DETAIL NONE10 TELECOMMUNICATIONS DISTRIBUTION FRAME GROUNDING BUSBAR (TGB) DETAIL NONE12 ELECTRICAL ELEVATIONS NONE1 EXIT 23 3/4"1"5 3/8"1/2"1/2"FLOOR LINE CEILING FLOOR LINE CEILING IC VC 11. 10. 9. 7. 6. 5. 4. 3. 2. 1.VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS. DIMENSIONS SHOWN ON OUTLET BOXES SHALL BE FROM THE FINISHED FLOOR TO THE TOP OF THE BOX - SEE ELEVATION DETAIL THIS SHEET. CONDUIT TO LIGHTS IS SHOWN TO INDICATE SWITCHING AND DOES NOT INDICATE QUANTITY OR EXACT LOCATION. OTHER CONDUIT SHOWN INDICATES CONNECTION, BUT DOES NOT INDICATE QUANTITY OR LOCATION. SUPPORT FLUORESCENT FIXTURES FROM STRUCTURE ABOVE. SEE DETAIL ON E-500 SERIES SHEETS. VERIFY LOCATION OF LIGHTS IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES AND RELOCATE, IF NECESSARY, AS REQUESTED BY THE ARCHITECT. VERIFY LOCATION OF MOTOR STARTERS, DISCONNECTS, PANELBOARDS, ETC., IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY OTHER TRADES AND RELOCATE TO AN ADJACENT, UNOBSTRUCTED AREA AS REQUESTED BY ARCHITECT. VERIFY HEIGHT AND LOCATION OF OUTLETS BEHIND WATER COOLERS WITH OTHER TRADES SO THAT OUTLETS ARE CONCEALED. SEE MECHANICAL PLANS FOR MECHANICAL EQUIPMENT LOCATIONS. VERIFY EXACT LOCATION OF ALL OUTLETS IN BUILT-INS AND CASEWORK FURNITURE WITH EQUIPMENT SUPPLIERS ROUGH-IN DRAWINGS BEFORE ROUGHING IN. MULTI-SWITCHED LIGHT FIXTURES SHALL HAVE THE OUTSIDE LAMPS CONTROLLED BY THE SWITCH(ES) CLOSEST TO THE DOOR OPENING AND THE MIDDLE LAMP(S) CONTROLLED BY THE OTHER SWITCH(ES). TERMINATE ALL COMMUNICATIONS/TECHNOLOGY SYSTEM CONDUIT STUBS WITH A BUSHING.11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. 12" X 2" X 1/4" COPPER GROUND BUS BAR BUS BAR STAND-OFF (TYPICAL) 12" X 4" X 1/4" COPPER GROUND BUS BAR BUS BAR STAND-OFF (TYPICAL) 12" X 4" X 1/4" COPPER GROUND BUS BAR BUS BAR STAND-OFF (TYPICAL) EXIT PR R WC SYMBOLS: FLOOR CEILING EQUIPMENT MOUNTING HEIGHTS SHALL BE INDICATED UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. CONCEAL RECEPTACLE BEHIND WATER COOLER. VERIFY EXACT MOUNTING HEIGHTS. WHERE DEVICES ARE LOCATED IN MASONRY WALLS LOCATE DEVICE WITHIN COARSING SO THAT MOUNTING INDICATED HERE IN IS NOT EXCEEDED. ALL RECEPTACLES ABOVE KITCHEN COUNTER AND NEAR BATH VANITIES SHALL BE INSTALLED HORIZONTALLY AT +44" AFF TO TOP OF THE BOX. NOTES: 1. 2. 3. 4. M W S JUNCTION BOXES HIGH VOLTAGE WIRING LOW VOLTAGE WIRING POWER PACK NOTES: DO NOT INSTALL POWER PACKS CLOSER THAN 6-12 INCHES FROM SENSOR. DO NOT INSTALL POWER PACKS WITHOUT JUNCTION BOXES. RJ-45 KEYNOTES: LOCK/STRIKE POWER SUPPLY IN 6"X6"X4" JUNCTION BOX. MOUNT ABOVE ACCESSIBLE CEILING ON SECURE SIDE OF DOOR. 8"X8"X4" JUNCTION BOX. MOUNT ABOVE ACCESSIBLE CEILING ON SECURE SIDE OF DOOR. PROXIMITY READER BACKBOX. 4" SQUARE BOX WITH SINGLE GANG ADAPTER RING. FLUSH MOUNT IN WALL. COORDINATE POSITION OF ROUGH-IN WITH CONSTRUCTION MANAGER BEFORE ROUGH-IN. 1" CONDUIT. 3/4" CONDUIT. ALL CONDUITS SHALL INCLUDE A NYLON PULL STRING. PULL STRING SHALL BE TIED OFF AT EACH END. FOR CONDUITS ENTERING DOOR FRAME, PULL STRING SHALL CONTINUE THE LENGTH OF THE FRAME BOTH ACROSS AND DOWN (2 STRINGS) AND SHALL NOT BE TIED OFF. USED FOR DOORS OVER 250' FROM TELECOM ROOM. USED FOR DOORS WITHIN 250' FROM TELECOM ROOM.96"96"48"48"72"48"36"20"20"20"NOTE220"20"96"96"72"96"48"20"48"48"84"F S F S FN D TOP VIEW SUPPORT BRACKET END VIEW GENERAL NOTES - APPLY TO ALL ELECTRICAL SHEETS 10'-0"10'-0"10'-0" SINGLE POLE LIGHT SWITCH TWO-GANG BOX WITH NYLON COVER PLATE SPACE FOR FUTURE CEILING FAN SWITCH REAR HOUSING FRONT COVER CEILING MANUFACTURER PRE-TERMINATED CABLES OR CAT 5e SPRING CLIPS (2) CEILING HOLE LOCAL THREE-WAY SWITCHES HOT BLK LOAD WHT CONTROL COMMON +24VDC OCCUPANCY SENSOR 24VDC LOAD LOCAL SWITCH PROVIDE ADDITIONAL SENSOR POWER/SWITCHING PACKS AS REQUIRED FOR ADDITIONAL ROOM LIGHT SWITCHING. PROVIDE OTHER RELAY PACKS AS INDICATED. NEUTRAL (UNSWITCHED) FLEXIBLE CONDUITCUSTOM SHEET METAL SUPPORT BRACKET. SEE DETAILS LAY-IN CEILING CEILING GRID 4"x1-1/2" BOX CEILING SUPPORT WIRE ADDITIONAL ROD OR WIRE SUPPORT STEEL JOIST OR BEAMS 18 GAUGE GALVANIZED JUNCTION BOX SHEET METAL LC LC 7/8"∅ OCCUPANCY SENSOR POWER AND SWITCHING PACK CEILING SUPPORT WIRE 1. LIGHTING FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM. UPON WRITTEN REQUEST TO THE ENGINEER, OTHER MEANS OF SUPPORT WILL BE CONSIDERED FOR APPROVAL. NOTE: FLEXIBLE CONDUIT DOUBLE LOOP SAFETY CHAIN MIN. 2 PER FIXTURE ANGLE IRON OR SLOTTED CHANNEL AS REQUIRED SECURELY SUPPORTED FROM STRUCTURE ABOVE CADDY CLAMPS OR EQUAL OUTLET BOX & SUPPORT ROD LAY-IN TYPE FIXTURE 3/0 COPPER CABLE EXOTHERMICALLY WELD CABLE TO GROUND RODS 3/4" DIA. X 10' LONG COPPER CLAD STEEL GROUND ROD 3/0 COPPER CABLE 120V POWER CIRCUIT 1" CONDUIT TO TELECOMMUNICATIONS ROOM 1" CONDUIT TO TELECOMMUNICATIONS ROOM 1 2 3 4 5 6 42 4 442 4 4 4 1 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.E-601 ELECTRICAL DETAILS 08/31/202108/31/2021 KREG SMEAD BARRY SIMPSON