Loading...
HomeMy WebLinkAboutEL101 - 1ST FLOOR LIGHTING PLAN1 2 3 4 5 6 7 5.1 A.1 B C D E E.9 1.9 F A 6.1 E.2 4.5 41 'K2' 41 'K2' 41 'K2-E' 41 'K2' 41 'K2' 41 'K5' 41 'K5' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 41 'K6' 40 'K7' 40 'K7-E' 40 'K7' 40 'K7' 40 'K7' 40 'K7-E' 40 'K7' 40 'K7' 40 'K7' 40 'K7' 40 'K7' 40 'K7' 40 'K7-E' 40 'K7' 40 'K7' 40 'K7-E' 40 'K7' 40 'K7' 40 'K7-E' 41 'X2' 41 'X2' 41 'X' 41 'X2' 41 'X' 41 'X2' 41 'X2' 41 'X2' 40 'K7' 40 'K7-E' 40 'K7' N/L 40 'K7' 40 'K7' 40 'K7-E' 40 'K7' 40 'K7-E' 40 'K7' 41 'K6' 41 'K6' 'EM' 'EM' 'EM' 'EM' 'EM' 'EM' ? 'EM' 40 'K7' 40 'K7' 40 'K7' 28 'K4' 28 'K4' 42 'K4' GENERAL SHEET NOTES A. SEE SHEET E-000 FOR SYMBOLS AND ABBREVIATIONS. B. REFER TO SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE. C. SEE SHEETS E-502 THROUGH E-503 FOR PANEL SCHEDULES. D. SEE SHEETS E-601THROUGH E-603 FOR ELECTRICAL DETAILS. E. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS. F. ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE FIXTURES UNLESS NOTED OTHERWISE. G. LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE AREA COVERAGE OF THE SPACE THEY ARE INSTALLED IN. SELECT PROPER SENSOR COVERAGE PATTERN FROM MANUFACTURER'S PRODUCT DATA TO DETERMINE COVERAGE. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY FOR PROPER OPERATION. H. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. I. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. J. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICES SERVES, THE BRANCH CIRCUIT IT CONTROLS AND THE DEVICE ADDRESS (IF APPLICABLE). K. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE REQUIRED EMERGENCY LIGHTING FED FROM THE 'EMERGENCY BRANCH' OF THE ESSENTIAL ELECTRICAL SYSTEM. L. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET AND CASEWORK AND BUILT-IN DETAILS. M. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. N. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. O. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. P. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. Q. SEE SHEET E-501 FOR LIGHTING SEQUENCE OF OPERATIONS SCHEDULE. R. PG1 & PG1E PARKING GARAGE FIXTURES TO BE SURFACE MOUNTED. S. MOUNT TYPE X1 AND X2 +6" ABOVE FINISHED DOOR FRAME. 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.EL101 1ST FLOOR LIGHTING PLAN 08/31/202108/31/2021 KRIS EHLERS BARRY SIMPSON 1/8" = 1'-0" 1ST FLOOR LIGHTING PLAN1 N 0 16'8'4' SHEET PLAN NOTES 1 MOUNT FIXTURE +8'-0" A.F.F. TO BOTTOM OF FIXTURE. 2 MOUNT FIXTURE TO 6'-0" ABOVE FINISHED GRADE. COORDINATE FINAL LOCATION WITH ARCHITECT. 3 LIGHTING FIXTURES IN THIS SPACE TO HAVE ON-BOARD OCCUPANCY SENSOR SET TO PROVIDE 100 PERCENT LIGHT OUTPUT IN OCCUPIED MODE AND 50 PERCENT LIGHT OUTPUT IN UNOCCUPIED MODE. 2 1 3 1 3 2 2 2 222 2 2 2 2 2 2 2