HomeMy WebLinkAboutH-302 - HVAC ENLARGED UNIT PLANSTT F 6/6 50 F 6/6 50 F 6/6 50 F 8/6 100 F 8/6 175 F 8/6 175 F 8/6 175 F 6/4 200 F 6/4 200 12/10 ø8 ø8 4ø ø8 18/12 G1175 FCU-4 12/10 EF-1 EF-1 EF-1 1 1 2 3 3 3 3 3 3 3 3 3 4 5 5 5 6 J- 36/6 8 9 10 11 6ø 6ø 6ø ø6ø8ø8 4ø 6ø ø6 ø6 4ø 7 12 13 FCU-3 G - 30/10 14/1214/12 EF-1 EF-1 F 12/6 150 F 6/6 50 12/6 F150 12/6 F150 12/6 F100 12/6 F100 12/6 F100 6/6 F50 F 6/6 50 J- 36/8 J- 36/8 3 3 3 3333 3 3 1 2 4 5 5 6 7 8 9 10 14 18166 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION DOCUMENTS800 West Monon Green Blvd.H-302 HVAC ENLARGED UNIT PLANS 08/31/202108/31/2021 THOMAS KENNEDY JOE BOLYARD SHEET PLAN NOTES 1 TERMINATE EXHAUST DUCTWORK WITH WALL CAP LIKE GREENHECK MODEL WC-6. 2 TERMINATE EXHAUST DUCTWORK WITH WALL CAP LIKE GREENHECK MODEL WC-4. 3 PROVIDE CEILNG RADIATION DAMPER AT ALL LOCATIONS WHERE GRILLES PENETRATE A FIRE RATED CEILING. 4 PROVIDE DRYER BOX PER MANUFACTURER'S INSTRUCTIONS. MOUNT BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR. SEAL AROUND BOX PERIMETER. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. INSTALL LABEL SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER VENT (INCLUDING NUMBER OF ELBOWS) PER MECHANICAL CODE. 5 PROVIDE BATHROOM EXHAUST FAN EF-1 IN WALL USE ONLY SMOOTH RADIUS ELBOWS +(R/D = 1.5). 6 PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT WITH TEH TOP OF DEVICE 48" ABOVE FINISHED FLOOR. 7 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR. SHEET METAL TO BE INSTALLED THROUGH THE WALL. PAINT BLACK ANY STUDS THAT INTERSECT. 8 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION TO SUPPLY DUCTWORK. FURISH AND INSTALL FIRE DAMPER WHERE DUCT PENETRATES RATED CEILING PARTITION. 9 PROVIDE TRAPPED 3/4" PLENUM RATED CPVC CONDENSATE DRAIN LINE AND TERMINATE ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT BLOCK FILTER ACCESS. 10 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO EXTERIOR WALL. ROUTE DOWN IN WALL TO 12" ABOVE GRADE, THEN OVER TO CONDENSING UNIT SERVING THIS APARTMENT. SEE OVERALL MECHANICAL PLANS FOR CONDENSING UNIT LOCATIONS. REFRIGERANT LINES SIZED PER MANUFACTURER'S RECOMMENDATIONS. 11 BALANCE OUTDOOR AIR DUCT TO 60 CFM. 12 PROVIDE RETURN GRILLE AT 54" ABOVE FINISHED FLOOR. 13 ROUTE 6"ø OUTDOOR AIR DUCT TO EXTERIOR WALL. TERMINATE DUCWORK WITH WALL CAP LIKE GREENHECK WC-6. 14 PROVIDE RETURN GRILLE AND MOUNT HIGH ON WALL, TIGHT TO CEILING. TRANSITION USING 30° REDUCER BEHIND. DUCTWORK ROUTES BELOW RATED ASSEMBLY AND ABOVE DROP CEILING IN CLOSET. 1/4" = 1'-0" UNIT 'C1' HVAC ENLARGED PLAN1 0 8'4'2' 1/4" = 1'-0" UNIT 'C2' HVAC ENLARGED PLAN208'4'2' 11700201 No. STATE OFJOSEPHR.BO L Y ARDPROFE S S IONA L E N G INEERDATE SIGNED 08/31/21REGISTER E D I ND I A N A