Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateWINDSOR BUILDINGCarmel, IN 46032CONSTRUCTION
DOCUMENTS800 West Monon Green Blvd.H-302
HVAC ENLARGED UNIT
PLANS
08/31/202108/31/2021
THOMAS KENNEDY JOE BOLYARD
SHEET PLAN NOTES
1 TERMINATE EXHAUST DUCTWORK WITH WALL CAP LIKE GREENHECK MODEL
WC-6.
2 TERMINATE EXHAUST DUCTWORK WITH WALL CAP LIKE GREENHECK MODEL
WC-4.
3 PROVIDE CEILNG RADIATION DAMPER AT ALL LOCATIONS WHERE GRILLES
PENETRATE A FIRE RATED CEILING.
4 PROVIDE DRYER BOX PER MANUFACTURER'S INSTRUCTIONS. MOUNT
BOTTOM OF DRYER BOX AT NOMINAL 6" ABOVE FINISHED FLOOR. SEAL
AROUND BOX PERIMETER. COORDINATE LOCATION WITH ARCHITECTURAL
PLANS. INSTALL LABEL SHOWING EQUIVALENT LENGTH OF INSTALLED DRYER
VENT (INCLUDING NUMBER OF ELBOWS) PER MECHANICAL CODE.
5 PROVIDE BATHROOM EXHAUST FAN EF-1 IN WALL USE ONLY SMOOTH RADIUS
ELBOWS +(R/D = 1.5).
6 PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT WITH TEH TOP OF DEVICE 48"
ABOVE FINISHED FLOOR.
7 FURNISH AND INSTALL TRANSFER GRILLE 6" ABOVE TOP OF DOOR. SHEET
METAL TO BE INSTALLED THROUGH THE WALL. PAINT BLACK ANY STUDS
THAT INTERSECT.
8 PROVIDE FLEXIBLE CONNECTION TO FCU DISCHARGE BEFORE CONNECTION
TO SUPPLY DUCTWORK. FURISH AND INSTALL FIRE DAMPER WHERE DUCT
PENETRATES RATED CEILING PARTITION.
9 PROVIDE TRAPPED 3/4" PLENUM RATED CPVC CONDENSATE DRAIN LINE AND
TERMINATE ABOVE HUB-DRAIN LOCATED IN MECHANICAL CLOSET. DO NOT
BLOCK FILTER ACCESS.
10 ROUTE REFRIGERANT LINES UP TO ABOVE CEILING AND OVER TO EXTERIOR
WALL. ROUTE DOWN IN WALL TO 12" ABOVE GRADE, THEN OVER TO
CONDENSING UNIT SERVING THIS APARTMENT. SEE OVERALL MECHANICAL
PLANS FOR CONDENSING UNIT LOCATIONS. REFRIGERANT LINES SIZED PER
MANUFACTURER'S RECOMMENDATIONS.
11 BALANCE OUTDOOR AIR DUCT TO 60 CFM.
12 PROVIDE RETURN GRILLE AT 54" ABOVE FINISHED FLOOR.
13 ROUTE 6"ø OUTDOOR AIR DUCT TO EXTERIOR WALL. TERMINATE DUCWORK
WITH WALL CAP LIKE GREENHECK WC-6.
14 PROVIDE RETURN GRILLE AND MOUNT HIGH ON WALL, TIGHT TO CEILING.
TRANSITION USING 30° REDUCER BEHIND. DUCTWORK ROUTES BELOW
RATED ASSEMBLY AND ABOVE DROP CEILING IN CLOSET.
1/4" = 1'-0"
UNIT 'C1' HVAC ENLARGED PLAN1
0 8'4'2'
1/4" = 1'-0"
UNIT 'C2' HVAC ENLARGED PLAN208'4'2'
11700201